Provided by: mandoc_1.14.6-1_amd64 bug

NAME

       mandocd - server process to format manual pages in batch mode

SYNOPSIS

       mandocd [-I os=name] [-T output] socket_fd

DESCRIPTION

       The mandocd utility formats many manual pages without requiring fork(2) and exec(3) overhead in between.
       It does not require listing all the manuals to be formatted on the command line, and it supports writing
       each formatted manual to its own file descriptor.

       This server requires that a connected UNIX domain socket(2) is already present at exec(3) time.
       Consequently, it cannot be started from the sh(1) command line because the shell cannot supply such a
       socket.  Typically, the socket is created by the parent process using socketpair(2) before calling
       fork(2) and exec(3) on mandocd.  The parent process will pass the file descriptor number as an argument
       to exec(3), formatted as a decimal ASCII-encoded integer.  See catman(8) for a typical implementation of
       a parent process.

       mandocd loops reading one-byte messages with recvmsg(2) from the file descriptor number socket_fd.  It
       ignores the byte read and only uses the out-of-band auxiliary struct cmsghdr control data, typically
       supplied by the calling process using CMSG_FIRSTHDR(3).  The parent process is expected to pass three
       file descriptors with each dummy byte.  The first one is used for mdoc(7) or man(7) input, the second one
       for formatted output, and the third one for error output.

       The options are as follows:

       -I os=name
               Override the default operating system name for the mdoc(7) Os and for the man(7) TH macro.

       -T output
               Output format.  The output argument can be ascii, utf8, or html; see mandoc(1).  In html output
               mode, the fragment output option is implied.  Other output options are not supported.

       After exhausting one input file descriptor, all three file descriptors are closed before reading the next
       dummy byte and control message.

       When a zero-byte message is read, when the socket_fd is closed by the parent process, or when an error
       occurs, mandocd exits.

EXIT STATUS

       The mandocd utility exits 0 on success, and >0 if an error occurs.

       A zero-byte message or a closed socket_fd is considered success.  Possible errors include:

          missing, invalid, or excessive exec(3) arguments

          recvmsg(2) failure, for example due to EMSGSIZE

          missing or unexpected control data, in particular a cmsg_level in the struct cmsghdr that differs
           from SOL_SOCKET, a cmsg_type that differs from SCM_RIGHTS, or a cmsg_len that is not three times the
           size of an int

          invalid file descriptors passed in the CMSG_DATA(3)

          resource exhaustion, in particular dup(2) or malloc(3) failure

       Except for memory exhaustion and similar system-level failures, parsing and formatting errors do not
       cause mandocd to return an error exit status.  Even after severe parsing errors, mandocd will simply
       accept and process the next input file descriptor.

SEE ALSO

       mandoc(1), mandoc(3), catman(8)

HISTORY

       The mandocd utility appeared in version 1.14.1 or the mandoc toolkit.

AUTHORS

       The concept was designed and implemented by Michael Stapelberg <stapelberg@debian.org>.  The mandoc(3)
       glue needed to make it a stand-alone process was added by Ingo Schwarze <schwarze@openbsd.org>.

CAVEATS

       If the parsed manual pages contain roff(7) .so requests, mandocd needs to be started with the current
       working directory set to the root of the manual page tree.  Avoid starting it in directories that contain
       secret files in any subdirectories, in particular in the user starting it has read access to these secret
       files.