Provided by: opa-fastfabric_10.10.3.0.11-1ubuntu3_amd64
NAME
opapaquery (All) Performs various queries of the performance management (PM)/performance administration (PA) agent and provides details about fabric performance. Refer to the Intel(R) Omni-Path Fabric Suite Fabric Manager User Guide for a description of the operation and client services of the PM/PA. By default, opapaquery queries the most recent data. However, if an image number (imgNum) and/or image offset (imgOff) is provided, the query returns previous sweep data. Queries that access previous sweep data return with the absolute image number representing that data, and therefore have an image offset of zero. opapaquery's operation is dependent on an Intel(R) Omni-Path Fabric Suite Fabric Manager version 6.0 or greater running as master SM/PM in the fabric. By default, opapaquery uses the first active port on the local system. However, if the Fabric Management Node is connected to more than one fabric (for example, a subnet), the HFI and port may be specified to select the fabric whose PA is to be queried.
Syntax
opapaquery [-v] [-h hfi|-b addr] [-p port] [-x gid] [-E] [-T ssl_params] [-o type] [-g groupName] [-l nodeLid] [-P portNumber] [--timeout] [-G nodeGuid] [-D nodeDesc] [-d delta] [-j date_time] [-q date_time] [-U] [-s select] [-f focus] [-S start] [-r range] [-n imgNum] [-O imgOff] [-y imgTime] [-m moveImgNum] [-M moveImgOff] [-V vfName]
Options
-v/--verbose Specifies the verbose output. -h/--hfi hfi Specifies the HFI, numbered 1..n. Using 0 specifies that the -p port port is a system-wide port number. Default is 0. -b/--oob address Specifies Out-of-Band address of node running the FE. Can be either hostname, IPv4, or IPv6 address. Default is "127.0.0.1". -p/--port port Specifies the port. • In-band: Numbered 1...n. Using 0 specifies the first active port. Default is 0. • Out-of-band: Port FE is listening on. Default is 3245. -x/--source-gid src_gid Specifies the source GID of the local GID. (This is required for most Path and Trace Record Queries when Out-of-Band.) -E/--feEsm Specifies the ESM FE. -T/--ssl-params file Specifies the SSL/TLS parameters XML file. Default is /etc/opa/opamgt_tls.xml. -o/--output type Specifies the output type. Default is groupList. See Output Types -g/--groupName groupName Specifies the group name for groupInfo query. -l/--lid lid Specifies the LID of the node. -P/--portNumber portNumber Specifies the port number within the node. --timeout Specifies the timeout (response wait time) in ms. Default is 1000 ms. -G/--nodeGuid Specifies the GUID of the node. -D/--nodeDesc Specifies the description of the node. -d/--delta delta Specifies the delta flag for portCounters query - 0 or 1. -j/--begin date_time Obtains portCounters over an interval beginning at date_time. date_time may be a time entered as HH:MM[:SS] or date as mm/dd/YYYY, dd.mm.YYYY, YYYY-mm-dd or date followed by time; for example, "2016-07-04 14:40". Relative times are taken as "x [second|minute|hour|day](s) ago. -q/--end date_time Obtains portCounters over an interval ending at date_time. date_time may be a time entered as HH:MM[:SS] or date as mm/dd/YYYY, dd.mm.YYYY, YYYY-mm-dd or date followed by time; for example, "2016-07-04 14:40". Relative times are taken as "x [second|minute|hour|day](s) ago. -U/--userCntrs Queries by user-controlled counters flag for portCounters. -s/--select select Specifies the 32-bit select flag for clearing port counters. Select bits for clrPortCounters. 0 is the least significant bit (rightmost). The clrPortCounters bit descriptions are listed in the order "mask - bit - location" below: • 0x80000000 - 31 - Transmit Data (XmitData) • 0x40000000 - 30 - Receive Data (RcvData) • 0x20000000 - 29 - Transmit Packets (XmitPkts) • 0x10000000 - 28 - Receive Packets (RcvPkts) • 0x08000000 - 27 - Multicast Transmit Packets (MulticastXmitPkts) • 0x04000000 - 26 - Multicast Receive Packets (MulticastRcvPkts) • 0x02000000 - 25 - Transmit Wait (XmitWait) • 0x01000000 - 24 - Congestion Discards (CongDiscards) • 0x00800000 - 23 - Receive FECN (RcvFECN) • 0x00400000 - 22 - Receive BECN (RcvBECN) • 0x00200000 - 21 - Transmit Time Congestion (XmitTimeCong) • 0x00100000 - 20 - Transmit Time Wasted BW (XmitWastedBW) • 0x00080000 - 19 - Transmit Time Wait Data (XmitWaitData) • 0x00040000 - 18 - Receive Bubble (RcvBubble) • 0x00020000 - 17 - Mark FECN (MarkFECN) • 0x00010000 - 16 - Receive Constraint Errors (RcvConstraintErrors) • 0x00008000 - 15 - Receive Switch Relay (RcvSwitchRelayErrors) • 0x00004000 - 14 - Transmit Discards (XmitDiscards) • 0x00002000 - 13 - Transmit Constraint Errors (XmitConstraintErrors) • 0x00001000 - 12 - Receive Remote Physical Errors (RcvRemotePhysicalErrors) • 0x00000800 - 11 - Local Link Integrity (LocalLinkIntegrityErrors) • 0x00000400 - 10 - Receive Errors (RcvErrors) • 0x00000200 - 9 - Excessive Buffer Overrun (ExcessiveBufferOverruns) • 0x00000100 - 8 - FM Configuration Errors (FMConfigErrors) • 0x00000080 - 7 - Link Error Recovery (LinkErrorRecovery) • 0x00000040 - 6 - Link Error Downed (LinkDowned) • 0x00000020 - 5 - Uncorrectable Errors (UncorrectableErrors) Select bits for clrVfPortCounters. 0 is the least significant bit (rightmost). The clrVfPortCounters bit descriptions are listed in the order "mask - bit - location" below: • 0x80000000 - 31 - VL Transmit Data (VLXmitData) • 0x40000000 - 30 - VL Receive Data (VLRcvData) • 0x20000000 - 29 - VL Transmit Packets (VLXmitPkts) • 0x10000000 - 28 - VL Receive Packets (VLRcvPkts) • 0x08000000 - 27 - VL Transmit Discards (VLXmitDiscards) • 0x04000000 - 26 - VL Congestion Discards (VLCongDiscards) • 0x02000000 - 25 - VL Transmit Wait (VLXmitWait) • 0x01000000 - 24 - VL Receive FECN (VLRcvFECN) • 0x00800000 - 23 - VL Receive BECN (VLRcvBECN) • 0x00400000 - 22 - VL Transmit Time Congestion (VLXmitTimeCong) • 0x00200000 - 21 - VL Transmit Wasted BW (VLXmitWastedBW) • 0x00100000 - 20 - VL Transmit Wait Data (VLXmitWaitData) • 0x00080000 - 19 - VL Receive Bubble (VLRcvBubble) • 0x00040000 - 18 - VL Mark FECN (VLMarkFECN) • Bits 17-0 reserved -f/--focus focus Specifies the focus select value for getting focus ports. focus select values are: unexpclrport Lists unexpectedly cleared ports - LID ordered. norespport Lists no response ports - LID ordered. skippedport Lists skipped ports - LID ordered. utilhigh Sorted by utilization - highest first. pktrate Sorted by packet rate - highest first. utillow Sorted by utilization - lowest first. integrity Sorted by integrity category - highest first. congestion Sorted by congestion category - highest first. smacongestion Sorted by SMA congestion category - highest first. bubbles Sorted by bubble category - highest first. security Sorted by security category - highest first. routing Sorted by routing category - highest first. vfutilhigh Sorted by utilization - highest first. vfpktrate Sorted by packet rate - highest first. vfutillow Sorted by utilization - lowest first. vfcongestion Sorted by congestion category - highest first. vfbubbles Sorted by bubble category - highest first. -S/--start start Specifies the start of window for focus ports, should always be 0. -r/--range range Specifies the size of window for focus ports list. -Q/--tuple Specifies a tuple that identifies a focus select value, comparator and argument in the form select: comparator:argument. Up to 8 tuples may be specified as: -Q s1:c1:a1 -Q s2:c2:a2 ... -Q s8:c8:a8 Valid focus select values are: utilization, pktrate, integrity, congestion, smacongestion, bubbles, security and routing. Valid comparator values are: GT, GE, LT, LE Valid arguments are: Any 64-bit value in hexadecimal or decimal. When specifying more than one tuple, a logical operator -Z/--operator must also be specified. -Z/--operator Specifies a logical operator used to join the results of the specified tuples. and - Specifies a port is returned if it meets all of the tuple filter criteria. or - Specifies a port is returned if it meets one or more of the tuple filter criteria. -n/--imgNum imgNum Specifies the 64-bit image number. -O/--imgOff imgOff Specifies the image offset. -y/--imgTime Specifies the image time. May be used with imageinfo, groupInfo, groupInfo, groupConfig, freezeImage, focusPorts, vfInfo, vfConfig, and vfFocusPorts. Will return closest image within image interval if possible. See --begin/--end above for format. -m/--moveImgNum moveImgNum Specifies the 64-bit image number. Used with moveFreeze to move a freeze image. -M/--moveImgOff moveImgOff Specifies the image offset. Can be used with moveFreeze to move a freeze image. -V/--vfName vfName Specifies the VF name for vfInfo query.
-h and -p options permit a variety of selections:
-h 0 First active port in system (Default). -h 0 -p 0 First active port in system. -h x First active port on HFI x. -h x -p 0 First active port on HFI x. -h 0 -p y Port y within system (no matter which ports are active). -h x -p y HFI x, port y.
Output Types
classPortInfo Specifies the class port info. groupList Specifies the list of PA groups. groupInfo Specifies the summary statistics of a PA group. Requires -g option for groupName. groupConfig Specifies the configuration of a PA group. Requires -g option for groupName. groupNodeInfo Specifies the node information of a PA group. Requires -g option for groupName. Options -l lid, -G nodeGuid and -D nodeDesc are optional. groupLinkInfo Specifies the link Information of a PA group. Requires -g option for groupName. Options -l lid and -P port are optional. Note that -P 255 specifies all ports. Option -P port without -l lid is ignored. portCounters Specifies the port counters of fabric port. Requires -l lid and -P port options. -d delta is optional. clrPortCounters Clears port counters of fabric port. Requires -l lid and -P port, and -s select options. clrAllPortCounters Clears all port counters in fabric. pmConfig Retrieves PM configuration information. freezeImage Creates freeze frame for image ID. Requires -n imgNum. releaseImage Releases freeze frame for image ID. Requires -n imgNum. renewImage Renews lease for freeze frame for image ID. Requires -n imgNum. moveFreeze Moves freeze frame from image ID to new image ID. Requires -n imgNum and -m moveImgNum. focusPorts Gets sorted list of ports using utilization or error values (from group buckets). Requires -g groupname, -f focus, -S start, -r range. imageInfo Gets configuration of a PA image (timestamps, etc.). Requires -n imgNum. vfList Specifies the list of virtual fabrics. vfInfo Specifies the summary statistics of a virtual fabric. Requires -V option for vfName. vfConfig Specifies the configuration of a virtual fabric. Requires -V option for vfName. vfPortCounters Specifies the port counters of fabric port. Requires -V vfName, -l lid and -P port options, -d delta is optional. vfFocusPorts Gets sorted list of virtual fabric ports using utilization or error values (from VF buckets). Requires -V vfname, -f focus, -S start, -r range. clrVfPortCounters Clears VF port counters of fabric port. Requires -l lid, -P port, -s select, and -V vfname options.
Examples
opapaquery -o classPortInfo opapaquery -o groupList opapaquery -o groupInfo -g All opapaquery -o groupConfig -g All opapaquery -o groupNodeInfo -g All -G <nodeGuid> opapaquery -o groupNodeInfo -g All -D <nodeDesc> opapaquery -o groupNodeInfo -g All -l 1 opapaquery -o groupNodeInfo -g All -l 1 -G <nodeGuid> opapaquery -o groupLinkInfo -g All opapaquery -o groupLinkInfo -g All -l 1 -P 1 opapaquery -o groupLinkInfo -g All -l 1 -P 255 opapaquery -o portCounters -l 1 -P 1 -d 1 opapaquery -o portCounters -l 1 -P 1 -d 1 -n 0x20000000d02 -O 1 opapaquery -o portCounters -l 1 -P 1 -d 1 -j 13:30 -q 14:20 opapaquery -o clrPortCounters -l 1 -P 1 -s 0xC0000000 (clears XmitData & RcvData) opapaquery -o clrAllPortCounters -s 0xC0000000 (clears XmitData & RcvData on all ports) opapaquery -o pmConfig opapaquery -o freezeImage -n 0x20000000d02 opapaquery -o releaseImage -n 0xd01 opapaquery -o renewImage -n 0xd01 opapaquery -o moveFreeze -n 0xd01 -m 0x20000000d02 -M -2 opapaquery -o focusPorts -g All -f integrity -S 0 -r 20 opapaquery -o focusPorts -g All -S 0 -r 20 -Z AND -Q integrity:ge:20 -Q bubbles:lt:10 opapaquery -o focusPorts -g All -f skippedport -S 0 -r 20 opapaquery -o imageInfo -n 0x20000000d02 opapaquery -o imageInfo -y "1 hour ago" opapaquery -o vfList opapaquery -o vfInfo -V Default opapaquery -o vfConfig -V Default opapaquery -o vfPortCounters -l 1 -P 1 -d 1 -V Default opapaquery -o clrVfPortCounters -l 1 -P 1 -s 0xC0000000 -V Default (clears VLXmitData & VLRcvData) opapaquery -o vfFocusPorts -V Default -f integrity -S 0 -r 20