Provided by: linuxptp_4.0-1ubuntu1_amd64 bug

NAME

       phc2sys - synchronize two or more clocks

SYNOPSIS

       phc2sys -a [ -r ] [ -r ] [ -f config-file ] [ options ] [ long-options ]
       phc2sys [ -f config-file ] [ -d pps-device ] [ -s device ] [ -c device ] [ -O offset ] [ -w ] [ options ]
       [ long-options ] ...

DESCRIPTION

       phc2sys is a program which synchronizes two or more clocks in  the  system.  Typically,  it  is  used  to
       synchronize  the system clock to a PTP hardware clock (PHC), which itself is synchronized by the ptp4l(8)
       program.

       With the -a option, the clocks to synchronize are fetched from the running ptp4l daemon and the direction
       of synchronization automatically follows changes of the PTP port states.

       Manual  configuration  is  also  possible. When using manual configuration, two synchronization modes are
       supported, one uses a pulse per second (PPS) signal provided by the source clock and the other mode reads
       time  from  the  source  clock  directly.  Some  clocks  can  be  used in both modes, the mode which will
       synchronize the time sink with better accuracy depends on hardware and driver implementation.

OPTIONS

       -a     Read the clocks to synchronize from running ptp4l and follow changes in the port states, adjusting
              the   synchronization   direction   automatically.   The  system  clock  (CLOCK_REALTIME)  is  not
              synchronized, unless the -r option is also specified.

       -r     Only valid together with the -a option. Instructs phc2sys to also  synchronize  the  system  clock
              (CLOCK_REALTIME). By default, the system clock is not considered as a possible time source. If you
              want the system clock to be eligible to become a time source, specify the -r option twice.

       -f config
              Read configuration from the specified file. No configuration file is read by default.

       -d pps-device
              Specify the  PPS  device  of  the  source  clock  (e.g.  /dev/pps0).  With  this  option  the  PPS
              synchronization mode is used instead of the direct mode.  The matching PHC must be specified using
              the -s command line option.  This option can be used only with the system clock as the time  sink.
              Not compatible with the -a option.

       -s device
              Specify  the  source  clock  by  device (e.g. /dev/ptp0) or interface (e.g. eth0) or by name (e.g.
              CLOCK_REALTIME for the system clock). When this option is used together with the  -d  option,  the
              source  clock is used only to correct the offset by whole number of seconds, which cannot be fixed
              with PPS alone. Not compatible with the -a option. This option does not support  bonded  interface
              (e.g. bond0, team0). If ptp4l has a port on an active-backup bond or team interface, the -a option
              can be used to track the active interface.

       -i interface
              Performs the exact same function as -s for compatibility reasons.  Previously  enabled  specifying
              source  clock  by  network interface. However, this can now be done using -s and this option is no
              longer necessary. As such it has been deprecated, and should no longer be used.

       -c device
              Specify the time sink by device (e.g. /dev/ptp1) or interface (e.g. eth1) or by  name. The default
              is  CLOCK_REALTIME (the system clock). Not compatible with the -a option. This option may be given
              up to 128 times.

       -E servo
              Specify which clock servo should be used. Valid values are pi for a PI controller, linreg  for  an
              adaptive  controller  using  linear  regression,  and ntpshm and refclock_sock for the NTP SHM and
              chrony SOCK reference clocks respectively to allow another process to synchronize the local clock.
              The default is pi.

       -P kp  Specify the proportional constant of the PI controller. The default is 0.7.

       -I ki  Specify the integral constant of the PI controller. The default is 0.3.

       -S step
              Specify  the  step  threshold  of  the  servo. It is the maximum offset that the servo corrects by
              changing the clock frequency instead of  stepping  the  clock.  The  clock  is  stepped  on  start
              regardless  of  the  option  if the offset is larger than 20 microseconds (unless the -F option is
              used). It's specified in seconds. The value of 0.0 disables stepping after the start. The  default
              is 0.0.

       -F step
              Specify  the  step  threshold  applied  only on the first update. It is the maximum offset that is
              corrected by changing the clock frequency. It's specified in seconds. The value  of  0.0  disables
              stepping on start. The default is 0.00002 (20 microseconds).

       -R update-rate
              Specify  the time sink update rate when running in the direct synchronization mode. The default is
              1 per second.

       -N phc-num
              Specify the number of source clock readings used for each time  sink  update.   Only  the  fastest
              reading is used to update the clock.  This is useful to minimize the error caused by random delays
              in scheduling and bus utilization.  The default is 5.

       -O offset
              Specify the offset between the sink and source times  in  seconds.  Not  compatible  with  the  -a
              option.  See TIME SCALE USAGE below.

       -L freq-limit
              The  maximum  allowed frequency offset between uncorrected clock and the system monotonic clock in
              parts per billion (ppb). This is used as a sanity check of the synchronized clock. When  a  larger
              offset  is measured, a warning message will be printed and the servo will be reset. When set to 0,
              the sanity check is disabled. The default is 200000000 (20%).

       -M segment
              The number of the SHM segment used by ntpshm servo.  The default is 0.

       -u summary-updates
              Specify the number of clock updates included in summary statistics. The statistics include  offset
              root mean square (RMS), maximum absolute offset, frequency offset mean and standard deviation, and
              mean of the delay in clock readings and standard deviation. The units are  nanoseconds  and  parts
              per  billion  (ppb).  If  zero,  the individual samples are printed instead of the statistics. The
              messages are printed at the LOG_INFO level.  The default is 0 (disabled).

       -w     Wait until ptp4l is in a synchronized state. If the -O option is not used, also  keep  the  offset
              between  the  sink  and source times updated according to the currentUtcOffset value obtained from
              ptp4l and the direction of the clock synchronization. Not compatible with the -a option.

       -n domain-number
              Specify the domain number used by ptp4l. The default is 0.

       -x     When a leap second is announced, don't apply it in the kernel by stepping the clock, but  let  the
              servo  correct  the one-second offset slowly by changing the clock frequency (unless the -S option
              is used).

       -z uds-address
              Specifies the address of the server's UNIX domain socket.  The default is /var/run/ptp4l.

       -l print-level
              Set the maximum syslog level of messages which should be printed or sent to the system logger. The
              default is 6 (LOG_INFO).

       -t message-tag
              Specify  the  tag which is added to all messages printed to the standard output or system log. The
              default is an empty string.

       -m     Print messages to the standard output.

       -q     Don't send messages to the system logger.

       -h     Display a help message.

       -v     Prints the software version and exits.

LONG OPTIONS

       Each and every configuration file option (see below in section FILE OPTIONS) may also appear as a  "long"
       style  command line argument.  For example, the transportSpecific option may be set using either of these
       two forms:

              --transportSpecific 1   --transportSpecific=1

       Option values given on the command line override values in the global section of the  configuration  file
       (which, in turn overrides default values).

CONFIGURATION FILE

       The  configuration  file  is  divided  into sections. Each section starts with a line containing its name
       enclosed in brackets and it follows with settings.  Each  setting  is  placed  on  a  separate  line,  it
       contains  the  name of the option and the value separated by whitespace characters. Empty lines and lines
       starting with # are ignored.

       The global section (indicated as [global]) sets the program options. This is the only used option.

FILE OPTIONS

       clock_servo
              The servo which is used to synchronize the local clock. Valid values are "pi" for a PI controller,
              "linreg"  for  an  adaptive controller using linear regression, "ntpshm" for the NTP SHM reference
              clock to allow another process to synchronize the local clock (the SHM segment number  is  set  to
              the  domain  number),  and "nullf" for a servo that always dials frequency offset zero (for use in
              SyncE nodes). The default is "pi."  Same as option -E (see above).

       domainNumber
              Specify the domain number used by phc2sys. The default is 0. Same as option -n (see above).

       first_step_threshold
              Specify the step threshold applied only on the first update. It is  the  maximum  offset  that  is
              corrected  by  adjusting  clock.  It's specified in seconds. The value of 0.0 disables stepping on
              start. The default is 0.00002 (20 microseconds).  Same as option -F (see above).

       free-running
              Don't adjust the sink clock if enabled. The default is 0 (disabled).

       kernel_leap
              When a leap second is announced, let the  kernel  apply  it  by  stepping  the  clock  instead  of
              correcting  the  one-second offset with servo, which would correct the one-second offset slowly by
              changing the clock frequency (unless the step_threshold option is set to correct  such  offset  by
              stepping).  Relevant  only with software time stamping. The default is 1 (enabled). Same as option
              -x (see above).

       logging_level
              The maximum logging level of messages which should be printed.  The default is 6 (LOG_INFO).  Same
              as option -l (see above).

       message_tag
              The  tag  which is added to all messages printed to the standard output or system log. The default
              is an empty string (which cannot be set in the  configuration  file  as  the  option  requires  an
              argument).  Same as option -t (see above).

       ntpshm_segment
              The  number  of  the  SHM segment used by ntpshm servo.  The default is 0.  Same as option -M (see
              above).

       pi_integral_const
              Specifies the integral constant of the PI controller.  Same as option -I (see above).

       pi_proportional_const
              Specifies the proportional constant of the PI controller.  Same as option -P (see above).

       refclock_sock_address
              The address of the UNIX domain socket to be used by  the  refclock_sock  servo.   The  default  is
              /var/run/refclock.ptp.sock.

       sanity_freq_limit
              The  maximum  allowed frequency offset between uncorrected clock and the system monotonic clock in
              parts per billion (ppb). This is used as a sanity check of the synchronized clock. When  a  larger
              offset  is measured, a warning message will be printed and the servo will be reset. When set to 0,
              the sanity check is disabled. The default is 200000000 (20%).  Same as option -L (see above).

       step_threshold
              Specifies the step threshold of the servo. It is the maximum offset that  the  servo  corrects  by
              changing  the  clock  frequency  (phase when using nullf servo) instead of stepping the clock. The
              clock is stepped on start regardless of the option if the offset is larger  than  20  microseconds
              (unless  the  -F  option  is  used). It's specified in seconds. The value of 0.0 disables stepping
              after the start. The default is 0.0.  Same as option -S (see above).

       transportSpecific
              The transport specific field. Must be in the range 0 to 255.  The default is 0.

       uds_address
              Specifies the address of the server's UNIX domain socket. The default  is  /var/run/ptp4  Same  as
              option -z (see above).

       use_syslog
              Print  messages  to  the system log if enabled.  The default is 1 (enabled).  Related to option -q
              (see above).

       verbose
              Print messages to the standard output if enabled.  The default is 0 (disabled).  Related to option
              -m (see above).

TIME SCALE USAGE

       Ptp4l  uses  either  PTP  time  scale  or UTC (Coordinated Universal Time) time scale.  PTP time scale is
       continuous and shifted against UTC by a few tens of seconds  as  PTP  time  scale  does  not  apply  leap
       seconds.

       In  hardware  time  stamping  mode, ptp4l announces use of PTP time scale and PHC is used for the stamps.
       That means PHC must follow PTP time scale while system clock follows UTC.  Time offset between these  two
       is maintained by phc2sys.

       Phc2sys  acquires  the  offset  value  either by reading it from ptp4l when -a or -w is in effect or from
       command line when -O is supplied.  Failure to maintain the correct offset can result in the local  system
       clock  being  offset  some whole number of seconds from the domain server's clock when in client mode, or
       incorect PTP time announced to the network in case the host is the domain server.

EXAMPLES

       Synchronize time automatically according to the current ptp4l state, synchronizing the  system  clock  to
       the remote server.

              phc2sys -a -r

       Same  as above, but when the host becomes the domain server, synchronize time in the domain to its system
       clock.

              phc2sys -a -rr

       Same as above, in an IEEE 802.1AS domain.

              phc2sys -a -rr --transportSpecific=1

       The host is a domain server, PTP clock is synchronized to system clock and the time  offset  is  obtained
       from  ptp4l.   Phc2sys  waits for ptp4l to get at least one port in server or client mode before starting
       the synchronization.

              phc2sys -c /dev/ptp0 -s CLOCK_REALTIME -w

       Same as above, time offset is provided on command line and phc2sys does not wait for ptp4l.

              phc2sys -c /dev/ptp0 -s CLOCK_REALTIME -O 37

       The host is in client mode, system clock is synchronized from PTP clock, phc2sys waits for ptp4l and  the
       offset is set automatically.

              phc2sys -s /dev/ptp0 -w

       Same  as  above,  PTP clock id is read from the network interface, the offset is provided on command line
       phc2sys does not wait.

              phc2sys -s eth0 -O -37

WARNING

       Be cautious when the same configuration file is used for both ptp4l and  phc2sys.   Keep  in  mind,  that
       values  specified  in  the  configuration  file  take  precedence over their default values. If a certain
       option, which is common to ptp4l and phc2sys, is specified to a non-default value  in  the  configuration
       file  (p.e.,  for ptp4l), then this non-default value applies also for phc2sys. This might be not what is
       expected.

       It is recommended to use seperate configuration files for  ptp4l  and  phc2sys  in  order  to  avoid  any
       unexpected behavior.

SEE ALSO

       ptp4l(8)