Provided by: freebsd-manpages_12.2-2_all bug

NAME

     ccd — Concatenated Disk driver

SYNOPSIS

     device ccd

DESCRIPTION

     The ccd driver provides the capability of combining one or more disks/partitions into one
     virtual disk.

     This document assumes that you are familiar with how to generate kernels, how to properly
     configure disks and devices in a kernel configuration file, and how to partition disks.

     In order to compile in support for the ccd, you must add a line similar to the following to
     your kernel configuration file:

           device    ccd       # concatenated disk devices

     As of the FreeBSD 3.0 release, you do not need to configure your kernel with ccd but may
     instead use it as a kernel loadable module.  Simply running ccdconfig(8) will load the
     module into the kernel.

     A ccd may be either serially concatenated or interleaved.  To serially concatenate the
     partitions, specify the interleave factor of 0.  Note that mirroring may not be used with an
     interleave factor of 0.

     There is a run-time utility that is used for configuring ccds.  See ccdconfig(8) for more
     information.

   The Interleave Factor
     If a ccd is interleaved correctly, a “striping” effect is achieved, which can increase
     sequential read/write performance.  The interleave factor is expressed in units of DEV_BSIZE
     (usually 512 bytes).  For large writes, the optimum interleave factor is typically the size
     of a track, while for large reads, it is about a quarter of a track.  (Note that this
     changes greatly depending on the number and speed of disks.)  For instance, with eight 7,200
     RPM drives on two Fast-Wide SCSI buses, this translates to about 128 for writes and 32 for
     reads.  A larger interleave tends to work better when the disk is taking a multitasking load
     by localizing the file I/O from any given process onto a single disk.  You lose sequential
     performance when you do this, but sequential performance is not usually an issue with a
     multitasking load.

     An interleave factor must be specified when using a mirroring configuration, even when you
     have only two disks (i.e., the layout winds up being the same no matter what the interleave
     factor).  The interleave factor will determine how I/O is broken up, however, and a value
     128 or greater is recommended.

     ccd has an option for a parity disk, but does not currently implement it.

     The best performance is achieved if all component disks have the same geometry and size.
     Optimum striping cannot occur with different disk types.

     For random-access oriented workloads, such as news servers, a larger interleave factor
     (e.g., 65,536) is more desirable.  Note that there is not much ccd can do to speed up
     applications that are seek-time limited.  Larger interleave factors will at least reduce the
     chance of having to seek two disk-heads to read one directory or a file.

   Disk Mirroring
     You can configure the ccd to “mirror” any even number of disks.  See ccdconfig(8) for how to
     specify the necessary flags.  For example, if you have a ccd configuration specifying four
     disks, the first two disks will be mirrored with the second two disks.  A write will be run
     to both sides of the mirror.  A read will be run to either side of the mirror depending on
     what the driver believes to be most optimal.  If the read fails, the driver will
     automatically attempt to read the same sector from the other side of the mirror.  Currently
     ccd uses a dual seek zone model to optimize reads for a multi-tasking load rather than a
     sequential load.

     In an event of a disk failure, you can use dd(1) to recover the failed disk.

     Note that a one-disk ccd is not the same as the original partition.  In particular, this
     means if you have a file system on a two-disk mirrored ccd and one of the disks fail, you
     cannot mount and use the remaining partition as itself; you have to configure it as a one-
     disk ccd.  You cannot replace a disk in a mirrored ccd partition without first backing up
     the partition, then replacing the disk, then restoring the partition.

   Linux Compatibility
     The Linux compatibility mode does not try to read the label that Linux' md(4) driver leaves
     on the raw devices.  You will have to give the order of devices and the interleave factor on
     your own.  When in Linux compatibility mode, ccd will convert the interleave factor from
     Linux terminology.  That means you give the same interleave factor that you gave as chunk
     size in Linux.

     If you have a Linux md(4) device in “legacy” mode, do not use the CCDF_LINUX flag in
     ccdconfig(8).  Use the CCDF_NO_OFFSET flag instead.  In that case you have to convert the
     interleave factor on your own, usually it is Linux' chunk size multiplied by two.

     Using a Linux RAID this way is potentially dangerous and can destroy the data in there.
     Since FreeBSD does not read the label used by Linux, changes in Linux might invalidate the
     compatibility layer.

     However, using this is reasonably safe if you test the compatibility before mounting a RAID
     read-write for the first time.  Just using ccdconfig(8) without mounting does not write
     anything to the Linux RAID.  Then you do a fsck.ext2fs (ports/sysutils/e2fsprogs) on the ccd
     device using the -n flag.  You can mount the file system read-only to check files in there.
     If all this works, it is unlikely that there is a problem with ccd.  Keep in mind that even
     when the Linux compatibility mode in ccd is working correctly, bugs in FreeBSD's ex2fs
     implementation would still destroy your data.

WARNINGS

     If just one (or more) of the disks in a ccd fails, the entire file system will be lost
     unless you are mirroring the disks.

     If one of the disks in a mirror is lost, you should still be able to back up your data.  If
     a write error occurs, however, data read from that sector may be non-deterministic.  It may
     return the data prior to the write or it may return the data that was written.  When a write
     error occurs, you should recover and regenerate the data as soon as possible.

     Changing the interleave or other parameters for a ccd disk usually destroys whatever data
     previously existed on that disk.

FILES

     /dev/ccd*  ccd device special files

SEE ALSO

     dd(1), ccdconfig(8), config(8), disklabel(8), fsck(8), gvinum(8), mount(8), newfs(8)

HISTORY

     The concatenated disk driver was originally written at the University of Utah.