Provided by: nvme-cli_2.11-1_amd64 bug

NAME

       nvme-zns-zone-append - Send an NVMe write command, provide results

SYNOPSIS

       nvme-zns-zone-append <device> [--namespace-id=<NUM> | -n <NUM>]
                                       [--zslba=<IONUM> | -s <IONUM>]
                                       [--data-size=<IONUM> | -z <IONUM>]
                                       [--metadata-size=<IONUM> | -y <IONUM>]
                                       [--data=<FILE> | -d <FILE>]
                                       [--metadata=<FILE> | -M <FILE>]
                                       [--limited-retry | -l]
                                       [--force-unit-access | -f]
                                       [--ref-tag=<NUM> | -r <NUM>]
                                       [--app-tag-mask=<NUM> | -m <NUM>]
                                       [--app-tag=<NUM> | -a <NUM>]
                                       [--prinfo=<NUM> | -p <NUM>]

DESCRIPTION

       The zone append command writes the logical blocks specified by the command to the medium
       from the data data buffer provided. Will use stdin by default if you don’t provide a file.

       On success, the program will report the LBA that was assigned to the data for the append
       operation.

OPTIONS

       -n <NUM>, --namespace-id=<NUM>
           Use the provided namespace id for the command. If not provided, the namespace id of
           the block device will be used. If the command is issued to a non-block device, the
           parameter is required.

       -s <IONUM>, --zslba=<IONUM>, -z <IONUM>, --data-size=<IONUM>
           Size of data, in bytes.

       -y <IONUM>, --metadata-size=<IONUM>
           Size of metadata in bytes.

       -d <FILE>, --data=<FILE>
           Data file providing the data to write. If none provided, contents are sent from STDIN.

       -M <FILE>, --metadata=<FILE>
           Metadata file, if necessary.

       -l, --limited-retry
           Sets the limited retry flag.

       -f, --force-unit-access
           Set the force-unit access flag.

       -r <NUM>, --ref-tag=<NUM>
           Optional reftag when used with protection information.

       -m <NUM>, --app-tag-mask=<NUM>
           Optional application tag mask when used with protection information.

       -a <NUM>, --app-tag=<NUM>
           Optional application tag when used with protection information.

       -p <NUM>, --prinfo=<NUM>
           Protection Information field definition.

EXAMPLES

       •   Append the data "hello world" into 4k worth of blocks into the zone starting at block
           0 for namespace 1:

               # echo "hello world" | nvme zns zone-append /dev/nvme0 -n 1 -s 0 -z 4k

NVME

       Part of the nvme-user suite