NAME

       freeipmi.conf - specify default values to FreeIPMI

DESCRIPTION

       The  FreeIPMI  configuration  file  can  be  used  to set alternate default values to many
       FreeIPMI tools so values don't have to be configured on the  command  line.   This  allows
       users  to  avoid  typing  in  a  long list of command line options every time a command is
       executed. It  can  also  be  used  to  hide  usernames,  passwords,  and  other  sensitive
       information from the ps(1) command.

       Currently,  the  tools  that  can  be  configured  with  the  configuration file are: bmc-
       device(8), bmc-info(8),  bmc-watchdog(8),  ipmi-chassis(8),  ipmi-config(8),  ipmi-fru(8),
       ipmi-oem(8),  ipmi-pet(8),  ipmi-raw(8), ipmi-sel(8), ipmi-sensors(8), ipmiconsole(8), and
       ipmipower(8).

       By default, the configuration file is stored at /etc/freeipmi//freeipmi.conf.   But  users
       may  select  a  different  configuration  file  at the command line with the --config-file
       option.

       Values specified on the command line override the configuration values  specified  in  the
       configuration file.

FORMAT

       The  configuration  options  that  can  be  specified in the configuration file are listed
       below. Each configuration option must be listed on  a  separate  line.  Arguments  for  an
       option are separated by any amount of whitespace. Multiple arguments are also separated by
       whitespace.  Comments can be marked by using the pound sign ("#") character, and lines can
       be continued on the next using backslash ("\").

       Note  that  it  is possible to list the username, password and other potentially sensitive
       information in the configuration file. If this data is stored  in  a  configuration  file,
       system administrators should limit access to this file.

GENERAL OPTIONS

       The  following  options  are  options  generally available to all tools, although specific
       options may be ignored by some. (For  example,  ipmiconsole(8)  and  ipmipower(8)  do  not
       perform  in-band communication, therefore they would ignore in-band communication options.
       Similarly bmc-watchdog(8) does not perform out-of-band communication, therefore  it  would
       ignore all out-of-band options).

       driver-type IPMIDRIVER
              Specify the default driver type to use.

       disable-auto-probe ENABLE|DISABLE
              Specify if IPMI devices should be probed for default settings.

       driver-address DRIVER-ADDRESS
              Specify the default in-band driver address to use.

       driver-device DEVICE
              Specify the default in-band driver device path to use.

       register-spacing REGISTER-SPACING
              Specify the default in-band driver register spacing to use.

       target-channel-number CHANNEL-NUMBER
              Specify the default in-band driver target channel number.

       target-slave-address SLAVE-ADDRESS
              Specify the default in-band driver target slave address.

       username USERNAME
              Specify the default username to use.

       password PASSWORD
              Specify the default password to use.

       k_g str
              Specify the default BMC key (K_g) to use. Prefix with '0x' to enter the key in hex.

       session-timeout MILLISECONDS
              Specify the default session timeout length to use in milliseconds.

       retransmission-timeout MILLISECONDS
              Specify the default retransmission timeout length to use in milliseconds.

       authentication-type AUTHENTICATION-TYPE
              Specify  the default authentication type to use. The following authentication types
              are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.

       cipher-suite-id CIPHER-SUITE-ID
              Specify the default cipher suite id to use. The  following  cipher  suite  ids  are
              supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.

       privilege-level PRIVILEGE-LEVEL
              Specify  the  default  privilege  type  to  use. The following privilege levels are
              supported: USER, OPERATOR, ADMIN.

       workaround-flags WORKAROUNDS
              Specify default workaround flags to use.  Multiple  workarounds  can  be  specified
              separated  by  whitespace.  Please  see  tool  manpages for details about available
              workarounds for each tool.  The  following  workarounds  are  supported:  assumeio,
              spinpoll, idzero, forcepermsg, unexpectedauth, endianseq, noauthcodecheck, authcap,
              nochecksumcheck, intel20, supermicro20, sun20,  opensesspriv,  integritycheckvalue,
              assumemaxsdrrecordcount,  solpayloadsize,  solport,  solstatus,  solchannelsupport,
              serialalertsdeferred, solpacketseq, skipchecks, assumesystemevent, discretereading,
              ignorescanningdisabled, assumebmcowner, ignoreauthcode, slowcommit, veryslowcommit,
              solchannelassumelanchannel, ignorestateflag, malformedack, guidformat, ipmiping.

SDR OPTIONS

       The following options are specific to tools that use the  sensor  data  repository  (SDR).
       They will be ignored by all other tools.

       quiet-cache ENABLE|DISABLE
              Specify if cache creation/deletion information should not be output by default.

       sdr-cache-directory DIRECTORY
              Specify the default sdr cache directory to use.

TIME OPTIONS

       The  following  options  are  specific  to tools that may output time values. They will be
       ignored by all other tools.

       utc-to-localtime ENABLE|DISABLE
              Specify if time should be converted from assumed UTC to localtime by default.

       localtime-to-utc ENABLE|DISABLE
              Specify if time should be converted from localtime to UTC by default.

       utc-offset SECONDS
              Specify a default UTC offset to be added to timestamps.

HOSTRANGED OPTIONS

       The following options are specific to tools that support hostranged output. They  will  be
       ignored by all other tools.

       buffer-output ENABLE|DISABLE
              Specify if hostranged output should be buffered by default.

       consolidate-output ENABLE|DISABLE
              Specify if hostranged output should be consolidated by default.

       fanout COUNT
              Specify the default multiple host fanout to use.

       eliminate ENABLE|DISABLE
              Specify if undetected hosts should be eliminated by default.

       always-prefix ENABLE|DISABLE
              Specify if output should be always prefixed by default.

BMC-DEVICE OPTIONS

       The following options are specific to bmc-device(8).  They will be ignored by other tools.

       bmc-device-username USERNAME
              Specify the default username to use for bmc-device(8).  If specified, will override
              the general option username above.

       bmc-device-password PASSWORD
              Specify the default password to use for bmc-device(8).  If specified, will override
              the general option password above.

       bmc-device-k_g str
              Specify  the  default  BMC  key (K_g) to use for bmc-device(8).  If specified, will
              override the general option k_g above. Prefix with '0x' to enter the key in hex.

       bmc-device-authentication-type AUTHENTICATION-TYPE
              Specify the default authentication type to use for  bmc-device(8).   If  specified,
              will   override   the  general  option  authentication-type  above.  The  following
              authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.

       bmc-device-cipher-suite-id CIPHER-SUITE-ID
              Specify the default cipher suite id to use for bmc-device(8).  If  specified,  will
              override  the  general option cipher-suite-id above. The following cipher suite ids
              are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.

       bmc-device-privilege-level PRIVILEGE-LEVEL
              Specify the default privilege type to use for bmc-device(8).   If  specified,  will
              override  the  general option privilege-level above. The following privilege levels
              are supported: USER, OPERATOR, ADMIN.

       bmc-device-workaround-flags WORKAROUNDS
              Specify default workaround flags to use  for  bmc-device(8).   If  specified,  will
              override  the  general  options workaround-flags above. Multiple workarounds can be
              specified separated by whitespace.  Please see bmc-device(8) manpage for  available
              workarounds.

BMC-INFO OPTIONS

       The following options are specific to bmc-info(8).  They will be ignored by other tools.

       bmc-info-username USERNAME
              Specify  the  default username to use for bmc-info(8).  If specified, will override
              the general option username above.

       bmc-info-password PASSWORD
              Specify the default password to use for bmc-info(8).  If specified,  will  override
              the general option password above.

       bmc-info-k_g str
              Specify  the  default  BMC  key  (K_g)  to use for bmc-info(8).  If specified, will
              override the general option k_g above. Prefix with '0x' to enter the key in hex.

       bmc-info-authentication-type AUTHENTICATION-TYPE
              Specify the default authentication type to use for bmc-info(8).  If specified, will
              override the general option authentication-type above. The following authentication
              types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.

       bmc-info-cipher-suite-id CIPHER-SUITE-ID
              Specify the default cipher suite id to use for  bmc-info(8).   If  specified,  will
              override  the  general option cipher-suite-id above. The following cipher suite ids
              are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.

       bmc-info-privilege-level PRIVILEGE-LEVEL
              Specify the default privilege type to use  for  bmc-info(8).   If  specified,  will
              override  the  general option privilege-level above. The following privilege levels
              are supported: USER, OPERATOR, ADMIN.

       bmc-info-workaround-flags WORKAROUNDS
              Specify default workaround flags  to  use  for  bmc-info(8).   If  specified,  will
              override  the  general  options workaround-flags above. Multiple workarounds can be
              specified separated by whitespace.  Please see bmc-info(8)  manpage  for  available
              workarounds.

       bmc-info-interpret-oem-data ENABLE|DISABLE
              Specify if bmc-info should attempt to interpret OEM data by default or not.

BMC-WATCHDOG OPTIONS

       The  following  options  are  specific  to bmc-watchdog(8).  They will be ignored by other
       tools.

       bmc-watchdog-workaround-flags WORKAROUNDS
              Specify default workaround flags to use for bmc-watchdog(8).   If  specified,  will
              override  the  general  options workaround-flags above. Multiple workarounds can be
              specified  separated  by  whitespace.   Please  see  bmc-watchdog(8)  manpage   for
              available workarounds.

       bmc-watchdog-verbose-logging ENABLE|DISABLE
              Specify if logging will be verbose by default.

       bmc-watchdog-no-logging ENABLE|DISABLE
              Specify if logging will be disabled by default.

IPMI-CHASSIS OPTIONS

       The  following  options  are  specific  to ipmi-chassis(8).  They will be ignored by other
       tools.

       ipmi-chassis-username USERNAME
              Specify the default username  to  use  for  ipmi-chassis(8).   If  specified,  will
              override the general option username above.

       ipmi-chassis-password PASSWORD
              Specify  the  default  password  to  use  for  ipmi-chassis(8).  If specified, will
              override the general option password above.

       ipmi-chassis-k_g str
              Specify the default BMC key (K_g) to use for ipmi-chassis(8).  If  specified,  will
              override the general option k_g above. Prefix with '0x' to enter the key in hex.

       ipmi-chassis-authentication-type AUTHENTICATION-TYPE
              Specify  the default authentication type to use for ipmi-chassis(8).  If specified,
              will  override  the  general  option  authentication-type  above.   The   following
              authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.

       ipmi-chassis-cipher-suite-id CIPHER-SUITE-ID
              Specify the default cipher suite id to use for ipmi-chassis(8).  If specified, will
              override the general option cipher-suite-id above. The following cipher  suite  ids
              are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.

       ipmi-chassis-privilege-level PRIVILEGE-LEVEL
              Specify  the default privilege type to use for ipmi-chassis(8).  If specified, will
              override the general option privilege-level above. The following  privilege  levels
              are supported: USER, OPERATOR, ADMIN.

       ipmi-chassis-workaround-flags WORKAROUNDS
              Specify  default  workaround  flags to use for ipmi-chassis(8).  If specified, will
              override the general options workaround-flags above. Multiple  workarounds  can  be
              specified   separated  by  whitespace.   Please  see  ipmi-chassis(8)  manpage  for
              available workarounds.

IPMI-CONFIG OPTIONS

       The following options are specific to ipmi-config(8).   They  will  be  ignored  by  other
       tools.

       ipmi-config-username USERNAME
              Specify  the  default  username  to  use  for  ipmi-config(8).   If specified, will
              override the general option username above.

       ipmi-config-password PASSWORD
              Specify the default  password  to  use  for  ipmi-config(8).   If  specified,  will
              override the general option password above.

       ipmi-config-k_g str
              Specify  the  default IPMI key (K_g) to use for ipmi-config(8).  If specified, will
              override the general option k_g above. Prefix with '0x' to enter the key in hex.

       ipmi-config-authentication-type AUTHENTICATION-TYPE
              Specify the default authentication type to use for ipmi-config(8).   If  specified,
              will   override   the  general  option  authentication-type  above.  The  following
              authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.

       ipmi-config-cipher-suite-id CIPHER-SUITE-ID
              Specify the default cipher suite id to use for ipmi-config(8).  If specified,  will
              override  the  general option cipher-suite-id above. The following cipher suite ids
              are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.

       ipmi-config-privilege-level PRIVILEGE-LEVEL
              Specify the default privilege type to use for ipmi-config(8).  If  specified,  will
              override  the  general option privilege-level above. The following privilege levels
              are supported: USER, OPERATOR, ADMIN.

       ipmi-config-workaround-flags WORKAROUNDS
              Specify default workaround flags to use for  ipmi-config(8).   If  specified,  will
              override  the  general  options workaround-flags above. Multiple workarounds can be
              specified separated by whitespace.  Please see ipmi-config(8) manpage for available
              workarounds.

       ipmi-config-verbose-count COUNT
              Specify default verbose count to use for ipmi-config(8).

IPMI-DCMI OPTIONS

       The following options are specific to ipmi-dcmi(8).  They will be ignored by other tools.

       ipmi-dcmi-username USERNAME
              Specify  the default username to use for ipmi-dcmi(8).  If specified, will override
              the general option username above.

       ipmi-dcmi-password PASSWORD
              Specify the default password to use for ipmi-dcmi(8).  If specified, will  override
              the general option password above.

       ipmi-dcmi-k_g str
              Specify  the  default  BMC  key  (K_g) to use for ipmi-dcmi(8).  If specified, will
              override the general option k_g above. Prefix with '0x' to enter the key in hex.

       ipmi-dcmi-authentication-type AUTHENTICATION-TYPE
              Specify the default authentication type to use  for  ipmi-dcmi(8).   If  specified,
              will   override   the  general  option  authentication-type  above.  The  following
              authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.

       ipmi-dcmi-cipher-suite-id CIPHER-SUITE-ID
              Specify the default cipher suite id to use for ipmi-dcmi(8).   If  specified,  will
              override  the  general option cipher-suite-id above. The following cipher suite ids
              are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.

       ipmi-dcmi-privilege-level PRIVILEGE-LEVEL
              Specify the default privilege type to use for  ipmi-dcmi(8).   If  specified,  will
              override  the  general option privilege-level above. The following privilege levels
              are supported: USER, OPERATOR, ADMIN.

       ipmi-dcmi-workaround-flags WORKAROUNDS
              Specify default workaround flags to  use  for  ipmi-dcmi(8).   If  specified,  will
              override  the  general  options workaround-flags above. Multiple workarounds can be
              specified separated by whitespace.  Please see ipmi-dcmi(8) manpage  for  available
              workarounds.

       ipmi-dcmi-interpret-oem-data ENABLE|DISABLE
              Specify if ipmi-dcmi should attempt to interpret OEM data by default or not.

IPMI-FRU OPTIONS

       The following options are specific to ipmi-fru(8).  They will be ignored by other tools.

       ipmi-fru-username USERNAME
              Specify  the  default username to use for ipmi-fru(8).  If specified, will override
              the general option username above.

       ipmi-fru-password PASSWORD
              Specify the default password to use for ipmi-fru(8).  If specified,  will  override
              the general option password above.

       ipmi-fru-k_g str
              Specify  the  default  BMC  key  (K_g)  to use for ipmi-fru(8).  If specified, will
              override the general option k_g above. Prefix with '0x' to enter the key in hex.

       ipmi-fru-authentication-type AUTHENTICATION-TYPE
              Specify the default authentication type to use for ipmi-fru(8).  If specified, will
              override the general option authentication-type above. The following authentication
              types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.

       ipmi-fru-cipher-suite-id CIPHER-SUITE-ID
              Specify the default cipher suite id to use for  ipmi-fru(8).   If  specified,  will
              override  the  general option cipher-suite-id above. The following cipher suite ids
              are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.

       ipmi-fru-privilege-level PRIVILEGE-LEVEL
              Specify the default privilege type to use  for  ipmi-fru(8).   If  specified,  will
              override  the  general option privilege-level above. The following privilege levels
              are supported: USER, OPERATOR, ADMIN.

       ipmi-fru-workaround-flags WORKAROUNDS
              Specify default workaround flags  to  use  for  ipmi-fru(8).   If  specified,  will
              override  the  general  options workaround-flags above. Multiple workarounds can be
              specified separated by whitespace.  Please see ipmi-fru(8)  manpage  for  available
              workarounds.

       ipmi-fru-verbose-count COUNT
              Specify default verbose count to use for ipmi-fru(8).

       ipmi-fru-bridge-fru ENABLE|DISABLE
              Specify if FRU entries on other controllers should be read by default or not.

       ipmi-fru-interpret-oem-data ENABLE|DISABLE
              Specify if ipmi-fru should attempt to interpret OEM data by default or not.

IPMI-OEM OPTIONS

       The following options are specific to ipmi-oem(8).  They will be ignored by other tools.

       ipmi-oem-username USERNAME
              Specify  the  default username to use for ipmi-oem(8).  If specified, will override
              the general option username above.

       ipmi-oem-password PASSWORD
              Specify the default password to use for ipmi-oem(8).  If specified,  will  override
              the general option password above.

       ipmi-oem-k_g str
              Specify  the  default  BMC  key  (K_g)  to use for ipmi-oem(8).  If specified, will
              override the general option k_g above. Prefix with '0x' to enter the key in hex.

       ipmi-oem-authentication-type AUTHENTICATION-TYPE
              Specify the default authentication type to use for ipmi-oem(8).  If specified, will
              override the general option authentication-type above. The following authentication
              types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.

       ipmi-oem-cipher-suite-id CIPHER-SUITE-ID
              Specify the default cipher suite id to use for  ipmi-oem(8).   If  specified,  will
              override  the  general option cipher-suite-id above. The following cipher suite ids
              are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.

       ipmi-oem-privilege-level PRIVILEGE-LEVEL
              Specify the default privilege type to use  for  ipmi-oem(8).   If  specified,  will
              override  the  general option privilege-level above. The following privilege levels
              are supported: USER, OPERATOR, ADMIN.

       ipmi-oem-workaround-flags WORKAROUNDS
              Specify default workaround flags  to  use  for  ipmi-oem(8).   If  specified,  will
              override  the  general  options workaround-flags above. Multiple workarounds can be
              specified separated by whitespace.  Please see ipmi-oem(8)  manpage  for  available
              workarounds.

       ipmi-oem-verbose-count COUNT
              Specify default verbose count to use for ipmi-oem(8).

IPMI-PET OPTIONS

       The following options are specific to ipmi-pet(8).  They will be ignored by other tools.

       ipmi-pet-username USERNAME
              Specify  the  default username to use for ipmi-pet(8).  If specified, will override
              the general option username above.

       ipmi-pet-password PASSWORD
              Specify the default password to use for ipmi-pet(8).  If specified,  will  override
              the general option password above.

       ipmi-pet-k_g str
              Specify  the  default  BMC  key  (K_g)  to use for ipmi-pet(8).  If specified, will
              override the general option k_g above. Prefix with '0x' to enter the key in hex.

       ipmi-pet-authentication-type AUTHENTICATION-TYPE
              Specify the default authentication type to use for ipmi-pet(8).  If specified, will
              override the general option authentication-type above. The following authentication
              types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.

       ipmi-pet-cipher-suite-id CIPHER-SUITE-ID
              Specify the default cipher suite id to use for  ipmi-pet(8).   If  specified,  will
              override  the  general option cipher-suite-id above. The following cipher suite ids
              are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.

       ipmi-pet-privilege-level PRIVILEGE-LEVEL
              Specify the default privilege type to use  for  ipmi-pet(8).   If  specified,  will
              override  the  general option privilege-level above. The following privilege levels
              are supported: USER, OPERATOR, ADMIN.

       ipmi-pet-workaround-flags WORKAROUNDS
              Specify default workaround flags  to  use  for  ipmi-pet(8).   If  specified,  will
              override  the  general  options workaround-flags above. Multiple workarounds can be
              specified separated by whitespace.  Please see ipmi-pet(8)  manpage  for  available
              workarounds.

       ipmi-pet-verbose-count COUNT
              Specify default verbose count to use for ipmi-pet(8).

       ipmi-pet-output-event-severity ENABLE|DISABLE
              Specify if ipmi-pet should output the event severity state by default.

       ipmi-pet-output-event-state ENABLE|DISABLE
              Specify if ipmi-pet should output the event state state by default.

       ipmi-pet-event-state-config-file FILE
              Specify the default event state configuration file.

       ipmi-pet-interpret-oem-data ENABLE|DISABLE
              Specify if ipmi-pet should attempt to interpret OEM data by default or not.

       ipmi-pet-entity-sensor-names ENABLE|DISABLE
              Specify  if  output  of  sensor  names  should  include entity ids and instances by
              default or not.

       ipmi-pet-no-sensor-type-output ENABLE|DISABLE
              Specify if output of the sensor type should be output by default or not.

       ipmi-pet-comma-separated-output ENABLE|DISABLE
              Specify if output should be comma separated by default or not.

       ipmi-pet-no-header-output ENABLE|DISABLE
              Specify if column headers should be output by default or not.

       ipmi-pet-non-abbreviated-units ENABLE|DISABLE
              Specify if output should have units abbreviated by default or not.

IPMI-RAW OPTIONS

       The following options are specific to ipmi-raw(8).  They will be ignored by other tools.

       ipmi-raw-username USERNAME
              Specify the default username to use for ipmi-raw(8).  If specified,  will  override
              the general option username above.

       ipmi-raw-password PASSWORD
              Specify  the  default password to use for ipmi-raw(8).  If specified, will override
              the general option password above.

       ipmi-raw-k_g str
              Specify the default BMC key (K_g) to  use  for  ipmi-raw(8).   If  specified,  will
              override the general option k_g above. Prefix with '0x' to enter the key in hex.

       ipmi-raw-authentication-type AUTHENTICATION-TYPE
              Specify the default authentication type to use for ipmi-raw(8).  If specified, will
              override the general option authentication-type above. The following authentication
              types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.

       ipmi-raw-cipher-suite-id CIPHER-SUITE-ID
              Specify  the  default  cipher  suite id to use for ipmi-raw(8).  If specified, will
              override the general option cipher-suite-id above. The following cipher  suite  ids
              are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.

       ipmi-raw-privilege-level PRIVILEGE-LEVEL
              Specify  the  default  privilege  type  to use for ipmi-raw(8).  If specified, will
              override the general option privilege-level above. The following  privilege  levels
              are supported: USER, OPERATOR, ADMIN.

       ipmi-raw-workaround-flags WORKAROUNDS
              Specify  default  workaround  flags  to  use  for  ipmi-raw(8).  If specified, will
              override the general options workaround-flags above. Multiple  workarounds  can  be
              specified  separated  by  whitespace.  Please see ipmi-raw(8) manpage for available
              workarounds.

IPMI-SEL OPTIONS

       The following options are specific to ipmi-sel(8).  They will be ignored by other tools.

       ipmi-sel-username USERNAME
              Specify the default username to use for ipmi-sel(8).  If specified,  will  override
              the general option username above.

       ipmi-sel-password PASSWORD
              Specify  the  default password to use for ipmi-sel(8).  If specified, will override
              the general option password above.

       ipmi-sel-k_g str
              Specify the default BMC key (K_g) to  use  for  ipmi-sel(8).   If  specified,  will
              override the general option k_g above. Prefix with '0x' to enter the key in hex.

       ipmi-sel-authentication-type AUTHENTICATION-TYPE
              Specify the default authentication type to use for ipmi-sel(8).  If specified, will
              override the general option authentication-type above. The following authentication
              types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.

       ipmi-sel-cipher-suite-id CIPHER-SUITE-ID
              Specify  the  default  cipher  suite id to use for ipmi-sel(8).  If specified, will
              override the general option cipher-suite-id above. The following cipher  suite  ids
              are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.

       ipmi-sel-privilege-level PRIVILEGE-LEVEL
              Specify  the  default  privilege  type  to use for ipmi-sel(8).  If specified, will
              override the general option privilege-level above. The following  privilege  levels
              are supported: USER, OPERATOR, ADMIN.

       ipmi-sel-workaround-flags WORKAROUNDS
              Specify  default  workaround  flags  to  use  for  ipmi-sel(8).  If specified, will
              override the general options workaround-flags above. Multiple  workarounds  can  be
              specified  separated  by  whitespace.  Please see ipmi-sel(8) manpage for available
              workarounds.

       ipmi-sel-verbose-count COUNT
              Specify default verbose count to use for ipmi-sel(8).

       ipmi-sel-types TYPE-LIST
              Specify default types to show SEL events  for.  Multiple  types  can  be  specified
              separated  by  whitespace.  Users  may  specify sensor types by string or by number
              (decimal or hex). Please see ipmi-sel(8) --list-types option to see possible string
              input types.

       ipmi-sel-exclude-types ENSOR-TYPES-LIST Specify
              default  sensor  types  to  not  show  SEL events for. Multiple sensor types can be
              specified separated by whitespace. Users may specify sensor types by string  or  by
              number.  Please  see  ipmi-sel(8)  --list-types option to see possible string input
              types.

       ipmi-sel-system-event-only ENABLE|DISABLE
              Specify if output should only include system event records.

       ipmi-sel-oem-event-only ENABLE|DISABLE
              Specify if output should only include OEM event records.

       ipmi-sel-output-manufacturer-id ENABLE|DISABLE
              Specify if output of OEM event records should include manufacturer ID by default or
              not.

       ipmi-sel-output-event-state ENABLE|DISABLE
              Specify if ipmi-sel should output the event state state by default.

       ipmi-sel-event-state-config-file FILE
              Specify the default event state configuration file.

       ipmi-sel-interpret-oem-data ENABLE|DISABLE
              Specify if ipmi-sel should attempt to interpret OEM data by default or not.

       ipmi-sel-output-oem-event-strings ENABLE|DISABLE
              Specify if ipmi-sel should output OEM event strings by default or not.

       ipmi-sel-entity-sensor-names ENABLE|DISABLE
              Specify  if  output  of  sensor  names  should  include entity ids and instances by
              default or not.

       ipmi-sel-no-sensor-type-output ENABLE|DISABLE
              Specify if output of the sensor type should be output by default or not.

       ipmi-sel-comma-separated-output ENABLE|DISABLE
              Specify if output should be comma separated by default or not.

       ipmi-sel-no-header-output ENABLE|DISABLE
              Specify if column headers should be output by default or not.

       ipmi-sel-non-abbreviated-units ENABLE|DISABLE
              Specify if output should have units abbreviated by default or not.

       ipmi-sel-legacy-output ENABLE|DISABLE
              Specify if output should be in legacy format by default or not.

IPMI-SENSORS OPTIONS

       The following options are specific to ipmi-sensors(8).  They  will  be  ignored  by  other
       tools.

       ipmi-sensors-username USERNAME
              Specify  the  default  username  to  use  for  ipmi-sensors(8).  If specified, will
              override the general option username above.

       ipmi-sensors-password PASSWORD
              Specify the default password  to  use  for  ipmi-sensors(8).   If  specified,  will
              override the general option password above.

       ipmi-sensors-k_g str
              Specify  the  default BMC key (K_g) to use for ipmi-sensors(8).  If specified, will
              override the general option k_g above. Prefix with '0x' to enter the key in hex.

       ipmi-sensors-authentication-type AUTHENTICATION-TYPE
              Specify the default authentication type to use for ipmi-sensors(8).  If  specified,
              will   override   the  general  option  authentication-type  above.  The  following
              authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.

       ipmi-sensors-cipher-suite-id CIPHER-SUITE-ID
              Specify the default cipher suite id to use for ipmi-sensors(8).  If specified, will
              override  the  general option cipher-suite-id above. The following cipher suite ids
              are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.

       ipmi-sensors-privilege-level PRIVILEGE-LEVEL
              Specify the default privilege type to use for ipmi-sensors(8).  If specified,  will
              override  the  general option privilege-level above. The following privilege levels
              are supported: USER, OPERATOR, ADMIN.

       ipmi-sensors-workaround-flags WORKAROUNDS
              Specify default workaround flags to use for ipmi-sensors(8).   If  specified,  will
              override  the  general  options workaround-flags above. Multiple workarounds can be
              specified  separated  by  whitespace.   Please  see  ipmi-sensors(8)  manpage   for
              available workarounds.

       ipmi-sensors-verbose-count COUNT
              Specify default verbose count to use for ipmi-sensors(8).

       ipmi-sensors-quiet-readings ENABLE|DISABLE
              Specify if sensor reading values and thresholds should not be output by default.

       ipmi-sensors-record-ids ECORD-IDS-LIST
              Specify  default  record ids to show sensor outputs for. Multiple record ids can be
              specified separated by whitespace.

       ipmi-sensors-exclude-record-ids ECORD-IDS-LIST
              Specify default record ids to not show sensor outputs for. Multiple record ids  can
              be specified separated by whitespace.

       ipmi-sensors-types TYPE-LIST
              Specify  default  types to show sensor outputs for. Multiple types can be specified
              separated by whitespace. Users may specify sensor types  by  string  or  by  number
              (decimal  or  hex).  Please see ipmi-sensors(8) --list-types option to see possible
              string input types.

       ipmi-sensors-exclude-types ENSOR-TYPES-LIST Specify
              default sensor types to not show sensor outputs for. Multiple sensor types  can  be
              specified  separated  by whitespace. Users may specify sensor types by string or by
              number. Please see ipmi-sensors(8) --list-types option to see possible string input
              types.

       ipmi-sensors-bridge-sensors ENABLE|DISABLE
              Specify if non-BMC sensors should be bridged by default or not.

       ipmi-sensors-shared-sensors ENABLE|DISABLE
              Specify if shared sensors should be output by default or not.

       ipmi-sensors-interpret-oem-data ENABLE|DISABLE
              Specify if ipmi-sensors should attempt to interpret OEM data by default or not.

       ipmi-sensors-ignore-not-available-sensors ENABLE|DISABLE
              Specify if ipmi-sensors should ignore not-available (i.e. N/A) sensors by default.

       ipmi-sensors-ignore-unrecognized-events ENABLE|DISABLE
              Specify  if  ipmi-sensors  should  ignore  unrecognized  events (i.e. 'Unrecognized
              Event') in sensors output by default.

       ipmi-sensors-output-event-bitmask ENABLE|DISABLE
              Specify  if  ipmi-sensors  should  output  event   bitmasks   instead   of   string
              representations by default.

       ipmi-sensors-output-sensor-state ENABLE|DISABLE
              Specify if ipmi-sensors should output the sensor state by default.

       ipmi-sensors-sensor-state-config-file FILE
              Specify the default sensor state configuration file.

       ipmi-sensors-entity-sensor-names ENABLE|DISABLE
              Specify  if  output  of  sensor  names  should  include entity ids and instances by
              default or not.

       ipmi-sensors-output-sensor-thresholds ENABLE|DISABLE
              Specify if ipmi-sensors should output sensor thresholds by default.

       ipmi-sensors-no-sensor-type-output ENABLE|DISABLE
              Specify if output of the sensor type should be output by default or not.

       ipmi-sensors-comma-separated-output ENABLE|DISABLE
              Specify if output should be comma separated by default or not.

       ipmi-sensors-no-header-output ENABLE|DISABLE
              Specify if column headers should be output by default or not.

       ipmi-sensors-non-abbreviated-units ENABLE|DISABLE
              Specify if output should have units abbreviated by default or not.

       ipmi-sensors-legacy-output ENABLE|DISABLE
              Specify if output should be in legacy format by default or not.

       ipmi-sensors-ipmimonitoring-legacy-output ENABLE|DISABLE
              Specify if output should be in ipmimonitoring legacy format by default or not.

IPMICONSOLE OPTIONS

       The following options are specific to ipmiconsole(8).   They  will  be  ignored  by  other
       tools.

       ipmiconsole-username USERNAME
              Specify  the  default  username  to  use  for  ipmiconsole(8).   If specified, will
              override the general option username above.

       ipmiconsole-password PASSWORD
              Specify the default  password  to  use  for  ipmiconsole(8).   If  specified,  will
              override the general option password above.

       ipmiconsole-k_g str
              Specify  the  default  BMC key (K_g) to use for ipmiconsole(8).  If specified, will
              override the general option k_g above. Prefix with '0x' to enter the key in hex.

       ipmiconsole-authentication-type AUTHENTICATION-TYPE
              Specify the default authentication type to use for ipmiconsole(8).   If  specified,
              will   override   the  general  option  authentication-type  above.  The  following
              authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.

       ipmiconsole-cipher-suite-id CIPHER-SUITE-ID
              Specify the default cipher suite id to use for ipmiconsole(8).  If specified,  will
              override  the  general option cipher-suite-id above. The following cipher suite ids
              are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.

       ipmiconsole-privilege-level PRIVILEGE-LEVEL
              Specify the default privilege type to use for ipmiconsole(8).  If  specified,  will
              override  the  general option privilege-level above. The following privilege levels
              are supported: USER, OPERATOR, ADMIN.

       ipmiconsole-workaround-flags WORKAROUNDS
              Specify default workaround flags to use for  ipmiconsole(8).   If  specified,  will
              override  the  general  options workaround-flags above. Multiple workarounds can be
              specified separated by whitespace.  Please see ipmiconsole(8) manpage for available
              workarounds.

       ipmiconsole-escape-char CHAR
              Specify the default escape character.

       ipmiconsole-dont-steal ENABLE|DISABLE
              Specify if in use SOL sessions should not be stolen by default.

       ipmiconsole-serial-keepalive ENABLE|DISABLE
              Specify if serial keepalive should be enabled by default.

       ipmiconsole-serial-keepalive-empty ENABLE|DISABLE
              Specify if serial keepalive empty should be enabled by default.

       ipmiconsole-sol-payload-instance NUM
              Specify the default SOL payload instance.

       ipmiconsole-deactivate-all-instances ENABLE|DISABLE
              Specify if SOL deactivate should deactivate all instances by default.

       ipmiconsole-lock-memory ENABLE|DISABLE
              Specify if memory should be locked by default.

IPMIPOWER OPTIONS

       The following options are specific to ipmipower(8).  They will be ignored by other tools.

       ipmipower-username USERNAME
              Specify  the default username to use for ipmipower(8).  If specified, will override
              the general option username above.

       ipmipower-password PASSWORD
              Specify the default password to use for ipmipower(8).  If specified, will  override
              the general option password above.

       ipmipower-k_g str
              Specify  the  default  BMC  key  (K_g) to use for ipmipower(8).  If specified, will
              override the general option k_g above. Prefix with '0x' to enter the key in hex.

       ipmipower-authentication-type AUTHENTICATION-TYPE
              Specify the default authentication type to use  for  ipmipower(8).   If  specified,
              will   override   the  general  option  authentication-type  above.  The  following
              authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.

       ipmipower-cipher-suite-id CIPHER-SUITE-ID
              Specify the default cipher suite id to use for ipmipower(8).   If  specified,  will
              override  the  general option cipher-suite-id above. The following cipher suite ids
              are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.

       ipmipower-privilege-level PRIVILEGE-LEVEL
              Specify the default privilege type to use for  ipmipower(8).   If  specified,  will
              override  the  general option privilege-level above. The following privilege levels
              are supported: USER, OPERATOR, ADMIN.

       ipmipower-workaround-flags WORKAROUNDS
              Specify default workaround flags to  use  for  ipmipower(8).   If  specified,  will
              override  the  general  options workaround-flags above. Multiple workarounds can be
              specified separated by whitespace.  Please see ipmipower(8) manpage  for  available
              workarounds.

       ipmipower-on-if-off ENABLE|DISABLE
              Specify if on-if-off functionality is enabled or disabled by default.

       ipmipower-wait-until-on ENABLE|DISABLE
              Specify if wait-until-on functionality is enabled or disabled by default.

       ipmipower-wait-until-off ENABLE|DISABLE
              Specify if wait-until-off functionality is enabled or disabled by default.

       ipmipower-oem-power-type OEM-POWER-TYPE
              Specify OEM power type to be used.

       ipmipower-retransmission-wait-timeout MILLISECONDS
              Specify the default retransmission wait timeout length to use in milliseconds.

       ipmipower-retransmission-backoff-count COUNT
              Specify the default retransmission backoff count to use for retransmissions.

       ipmipower-ping-interval MILLISECONDS
              Specify the default ping interval length to use in milliseconds.

       ipmipower-ping-timeout MILLISECONDS
              Specify the default ping timeout length to use in milliseconds.

       ipmipower-ping-packet-count COUNT
              Specify the default ping packet count size to use.

       ipmipower-ping-percent PERCENT
              Specify the default ping percent value to use.

       ipmipower-ping-consec-count COUNT
              Specify the default ping consecutive count value to use.

FILES

       /etc/freeipmi//freeipmi.conf

REPORTING BUGS

       Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

COPYRIGHT

       Copyright © 2003-2015 FreeIPMI Core Team.

       FreeIPMI is free software; you can redistribute it and/or modify it under the terms of the
       GNU General Public License as published by the Free Software Foundation; either version  3
       of the License, or (at your option) any later version.