Provided by: nut-server_2.8.1-3.1ubuntu2_amd64 bug

NAME

       powerpanel - Driver for serial PowerPanel Plus compatible UPS equipment

NOTE

       This man page only documents the hardware-specific features of the powerpanel driver. For
       information about the core driver, see nutupsdrv(8).

SUPPORTED HARDWARE

       This driver supports CyberPower BC1200, PR2200 and many other similar devices, both for
       the text and binary protocols. The driver will autodetect which protocol is used.

       If your Cyber Power Systems UPS has a USB port, you may wish to use the usbhid-ups(8)
       driver. The snmp-ups(8) driver supports several network cards via SNMP.

EXTRA ARGUMENTS

       This driver supports the following optional settings in ups.conf(5):

       protocol=[text,binary]
           Override the default autodetection of the protocol.

       manufacturer=value
           If you don’t like the autodetected value, you can override this by setting it here.

       model=value
           Like manufacturer above.

       serial=value
           Like manufacturer above.

       ondelay=value
           Time to wait before switching on the UPS (1 - 9999 minutes, 0=indefinite). Only
           available with the text protocol driver (see Support Status).

       offdelay=value
           Time to wait before shutting down the UPS (6 - 600 seconds). Values below 60 seconds
           will be truncated to 6 seconds intervals, values above 60 seconds to 60 seconds
           intervals. Only available with the text protocol driver (see Support Status).

VARIABLES

       Depending on the type of your UPS unit, some of the following variables may be changed
       with upsrw(8). If the driver can’t read a variable from the UPS, it will not be made
       available.

       input.transfer.high
           writable: high transfer voltage point in V

       input.transfer.low
           writable: low transfer voltage point in V

       battery.charge.low
           writable: remaining battery charge percentage for low battery warning

       output.voltage.nominal
           writable: nominal output voltage in V

       ups.start.battery
           writable: allow cold start from battery

COMMANDS

       Depending on the type of your UPS unit, some of the following commands may be available.

       •   test.battery.start.quick, test.battery.stop

       •   beeper.enable, beeper.disable, beeper.toggle

       •   shutdown.return, shutdown.reboot, shutdown.stayoff

       On many devices, these commands are unreliable, so before using them you must verify that
       these work as expected (see Shutdown Issues).

       •   shutdown.stop

SUPPORT STATUS

       Vendor support is absent for this driver, so if you need some features that are currently
       not available, provide ample documentation on what the driver should sent to the UPS in
       order to make this work. If more information would be available on the binary protocol, it
       would probably be possible to make ondelay and offdelay configurable. So far, nobody has
       taken the time to investigate what we should tell the UPS to make this work, and
       CyberPower isn’t willing to share this with us.

SHUTDOWN ISSUES

       If the shutdown.return command on your UPS doesn’t seem to work, chances are that your UPS
       is an older model. Try a couple of different settings for offdelay. If no value in the
       range 6..600 works, your UPS likely doesn’t support this. In order to get the expected
       behaviour, it requires shutdown.stayoff (when on battery) and shutdown.reboot (when on
       mains). The driver will automatically fallback to these commands if shutdown.return fails,
       and tries to detect which one should be used when called with the -k option (or through
       upsdrvctl shutdown).

       This isn’t bullet-proof, however, and you should be prepared that the power will either
       not be shutdown or that it doesn’t return when the power comes back. All models supported
       by the binary protocol and many supported through the text protocol are affected by this.

KNOWN PROBLEMS

       The CyberPower OP series don’t offer direct voltage, charge, frequency and temperature
       readings. Instead, they will return a binary value that needs conversion to the actual
       value.

       The exact conversion needed is unknown at the time of this writing, hence an estimation
       was made based om readings from actual devices. This may (probably will) be off, possibly
       a lot. Unless you can tell us the exact mapping between values from the UPS and actual
       readings, don’t bother to complain. We’ve done the best we can based on the limited
       information available. Remember, a UPS isn’t a measuring instrument.

AUTHORS

       Arjen de Korte <arjen@de-korte.org>, Doug Reynolds <mav@wastegate.net>

SEE ALSO

   The core driver:
       nutupsdrv(8)

   Other drivers:
       usbhid-ups(8), snmp-ups(8)

   Internet resources:
       The NUT (Network UPS Tools) home page: https://www.networkupstools.org/