Provided by: argyll_1.5.1-5ubuntu1_amd64
NAME
Create - Create ICC profile.
DESCRIPTION
Create ICC profile, Version 1.5.1 Author: Graeme W. Gill, licensed under the AGPL Version 3 Diagnostic: Unknown flag '-' usage: debian/tmp/usr/bin/colprof [-options] inoutfile -v Verbose mode -A manufacturer Manufacturer description string -M model Model description string -D description Profile Description string (Default "inoutfile") -C copyright Copyright string -Z tmnb Attributes: Transparency, Matte, Negative, BlackAndWhite -Z prsa Default intent: Perceptual, Rel. Colorimetric, Saturation, Abs. Colorimetric -q lmhu Quality - Low, Medium (def), High, Ultra -b [lmhun] Low quality B2A table - or specific B2A quality or none for input device -y Verify A2B profile -ni Don't create input (Device) shaper curves -np Don't create input (Device) grid position curves -no Don't create output (PCS) shaper curves -nc Don't put the input .ti3 data in the profile -k zhxr Black value target: z = zero K, h = 0.5 K, x = max K, r = ramp K (def.) -k p stle stpo enpo enle shape stle: K level at White 0.0 - 1.0 stpo: start point of transition Wh 0.0 - Bk 1.0 enpo: End point of transition Wh 0.0 - Bk 1.0 enle: K level at Black 0.0 - 1.0 shape: 1.0 = straight, 0.0-1.0 concave, 1.0-2.0 convex -K parameters Same as -k, but target is K locus rather than K value itself -l tlimit override total ink limit, 0 - 400% (default from .ti3) -L klimit override black ink limit, 0 - 100% (default from .ti3) -a lxXgsmGS Algorithm type override l = Lab cLUT (def.), x = XYZ cLUT, X = display XYZ cLUT + matrix g = gamma+matrix, s = shaper+matrix, m = matrix only, G = single gamma+matrix, S = single shaper+matrix -u If input profile, auto scale WP to allow extrapolation -uc If input profile, clip cLUT values above WP -U scale If input profile, scale media white point by scale -R Restrict white <= 1.0, black and primaries to be +ve -f [illum] Use Fluorescent Whitening Agent compensation [opt. simulated inst. illum.: M0, M1, M2, A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp] -i illum Choose illuminant for computation of CIE XYZ from spectral data & FWA: A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp -o observ Choose CIE Observer for spectral data: 1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2 -r avgdev Average deviation of device+instrument readings as a percentage (default 0.50%) -s src.icc Apply gamut mapping to output profile perceptual B2A table for given source space -S src.icc Apply gamut mapping to output profile perceptual and saturation B2A table -nP Use colormetric source gamut to make output profile perceptual table -nS Use colormetric source gamut to make output profile saturation table -g src.gam Use source image gamut as well for output profile gamut mapping -p absprof,... Incorporate abstract profile(s) into output tables -t intent Override gamut mapping intent for output profile perceptual table: -T intent Override gamut mapping intent for output profile saturation table: a - Absolute Colorimetric (in Jab) [ICC Absolute Colorimetric] aw - Absolute Colorimetric (in Jab) with scaling to fit white point aa - Absolute Appearance r - White Point Matched Appearance [ICC Relative Colorimetric] la - Luminance axis matched Appearance p - Perceptual (Preferred) (Default) [ICC Perceptual] pa - Perceptual Apperance ms - Saturation s - Enhanced Saturation [ICC Saturation] al - Absolute Colorimetric (Lab) rl - White Point Matched Appearance (Lab) -c viewcond set input viewing conditions for output profile CIECAM02 gamut mapping, either an enumerated choice, or a parameter -d viewcond set output viewing conditions for output profile CIECAM02 gamut mapping either an enumerated choice, or a parameter Also sets out of gamut clipping CAM space. either an enumerated choice, or a series of parameters:value changes pp - Practical Reflection Print (ISO-3664 P2) pe - Print evaluation environment (CIE 116-1995) pc - Critical print evaluation environment (ISO-3664 P1) mt - Monitor in typical work environment mb - Bright monitor in bright work environment md - Monitor in darkened work environment jm - Projector in dim environment jd - Projector in dark environment pcd - Photo CD - original scene outdoors ob - Original scene - Bright Outdoors cx - Cut Sheet Transparencies on a viewing box -P Create gamut gammap_p.wrl and gammap_s.wrl diagostics -O outputfile Override the default output filename. inoutfile Base name for input.ti3/output.icc file Author: Graeme W. Gill, licensed under the AGPL Version 3 Diagnostic: Unknown flag '-' usage: debian/tmp/usr/bin/colprof [-options] inoutfile -v Verbose mode -A manufacturer Manufacturer description string -M model Model description string -D description Profile Description string (Default "inoutfile") -C copyright Copyright string -Z tmnb Attributes: Transparency, Matte, Negative, BlackAndWhite -Z prsa Default intent: Perceptual, Rel. Colorimetric, Saturation, Abs. Colorimetric -q lmhu Quality - Low, Medium (def), High, Ultra -b [lmhun] Low quality B2A table - or specific B2A quality or none for input device -y Verify A2B profile -ni Don't create input (Device) shaper curves -np Don't create input (Device) grid position curves -no Don't create output (PCS) shaper curves -nc Don't put the input .ti3 data in the profile -k zhxr Black value target: z = zero K, h = 0.5 K, x = max K, r = ramp K (def.) -k p stle stpo enpo enle shape stle: K level at White 0.0 - 1.0 stpo: start point of transition Wh 0.0 - Bk 1.0 enpo: End point of transition Wh 0.0 - Bk 1.0 enle: K level at Black 0.0 - 1.0 shape: 1.0 = straight, 0.0-1.0 concave, 1.0-2.0 convex -K parameters Same as -k, but target is K locus rather than K value itself -l tlimit override total ink limit, 0 - 400% (default from .ti3) -L klimit override black ink limit, 0 - 100% (default from .ti3) -a lxXgsmGS Algorithm type override l = Lab cLUT (def.), x = XYZ cLUT, X = display XYZ cLUT + matrix g = gamma+matrix, s = shaper+matrix, m = matrix only, G = single gamma+matrix, S = single shaper+matrix -u If input profile, auto scale WP to allow extrapolation -uc If input profile, clip cLUT values above WP -U scale If input profile, scale media white point by scale -R Restrict white <= 1.0, black and primaries to be +ve -f [illum] Use Fluorescent Whitening Agent compensation [opt. simulated inst. illum.: M0, M1, M2, A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp] -i illum Choose illuminant for computation of CIE XYZ from spectral data & FWA: A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp -o observ Choose CIE Observer for spectral data: 1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2 -r avgdev Average deviation of device+instrument readings as a percentage (default 0.50%) -s src.icc Apply gamut mapping to output profile perceptual B2A table for given source space -S src.icc Apply gamut mapping to output profile perceptual and saturation B2A table -nP Use colormetric source gamut to make output profile perceptual table -nS Use colormetric source gamut to make output profile saturation table -g src.gam Use source image gamut as well for output profile gamut mapping -p absprof,... Incorporate abstract profile(s) into output tables -t intent Override gamut mapping intent for output profile perceptual table: -T intent Override gamut mapping intent for output profile saturation table: a - Absolute Colorimetric (in Jab) [ICC Absolute Colorimetric] aw - Absolute Colorimetric (in Jab) with scaling to fit white point aa - Absolute Appearance r - White Point Matched Appearance [ICC Relative Colorimetric] la - Luminance axis matched Appearance p - Perceptual (Preferred) (Default) [ICC Perceptual] pa - Perceptual Apperance ms - Saturation s - Enhanced Saturation [ICC Saturation] al - Absolute Colorimetric (Lab) rl - White Point Matched Appearance (Lab) -c viewcond set input viewing conditions for output profile CIECAM02 gamut mapping, either an enumerated choice, or a parameter -d viewcond set output viewing conditions for output profile CIECAM02 gamut mapping either an enumerated choice, or a parameter Also sets out of gamut clipping CAM space. either an enumerated choice, or a series of parameters:value changes pp - Practical Reflection Print (ISO-3664 P2) pe - Print evaluation environment (CIE 116-1995) pc - Critical print evaluation environment (ISO-3664 P1) mt - Monitor in typical work environment mb - Bright monitor in bright work environment md - Monitor in darkened work environment jm - Projector in dim environment jd - Projector in dark environment pcd - Photo CD - original scene outdoors ob - Original scene - Bright Outdoors cx - Cut Sheet Transparencies on a viewing box -P Create gamut gammap_p.wrl and gammap_s.wrl diagostics -O outputfile Override the default output filename. inoutfile Base name for input.ti3/output.icc file