Provided by: ganeti-htools_2.9.3-1_amd64 bug

NAME

       hroller - Cluster rolling maintenance scheduler for Ganeti

SYNOPSIS

       hroller {backend options...} [algorithm options...] [reporting options...]

       hroller --version

       Backend options:

       { -m cluster | -L[ path ] | -t data-file | -I path }

       [ --force ]

       Algorithm options:

       [ -G name ] [ -O name... ] [ --node-tags tag,.. ] [ --skip-non-redundant ]

       [ --offline-maintenance ] [ --ignore-non-redundant ]

       Reporting options:

       [ -v... | -q ] [ -S file ] [ --one-step-only ] [ --print-moves ]

DESCRIPTION

       hroller  is  a cluster maintenance reboot scheduler.  It can calculate which set of nodes can be rebooted
       at the same time while avoiding having both primary and secondary nodes being rebooted at the same time.

       For backends that support identifying the master node (currently RAPI  and  LUXI),  the  master  node  is
       scheduled  as  the last node in the last reboot group.  Apart from this restriction, larger reboot groups
       are put first.

   ALGORITHM FOR CALCULATING OFFLINE REBOOT GROUPS
       hroller will view the nodes as vertices of an undirected graph, with two kind of edges.   Firstly,  there
       are edges from the primary to the secondary node of every instance.  Secondly, two nodes are connected by
       an  edge  if they are the primary nodes of two instances that have the same secondary node.  It will then
       color the graph using a few different heuristics, and return the minimum-size color set found.  Node with
       the same color can then simultaneously migrate all instance off to their respective secondary nodes,  and
       it is safe to reboot them simultaneously.

OPTIONS

       For a description of the standard options check htools(1) and hbal(1).

       --force
              Do not fail, even if the master node cannot be determined.

       --node-tags tag,...
              Restrict to nodes having at least one of the given tags.

       --full-evacuation
              Also  plan  moving  secondaries out of the nodes to be rebooted.  For each instance the move is at
              most a migrate (if it was primary on that node) followed by a replace secondary.

       --skip-non-redundant
              Restrict to nodes not hosting any non-redundant instance.

       --offline-maintenance
              Pretend that all instances are shutdown before the reboots are carried out.  I.e., only edges from
              the primary to the secondary node of an instance are considered.

       --ignore-non-redundnant
              Pretend that the non-redundant instances do not exist, and only take instances  with  primary  and
              secondary node into account.

       --one-step-only
              Restrict to the first reboot group.  Output the group one node per line.

       --print-moves
              After  each  group list for each affected instance a node where it can be evacuated to.  The moves
              are computed under the assumption that after each reboot group, all instances are  moved  back  to
              their initial position.

BUGS

       If  instances  are  online  the  tool should refuse to do offline rolling maintenances, unless explicitly
       requested.

       End-to-end shelltests should be provided.

EXAMPLES

   Online Rolling reboots, using tags
       Selecting by tags and getting output for one step only can be used for planing the next maintenance step.

              $ hroller --node-tags needsreboot --one-step-only -L
              'First Reboot Group'
               node1.example.com
               node3.example.com

       Typically these nodes would be drained and migrated.

              $ GROUP=`hroller --node-tags needsreboot --one-step-only --no-headers -L`
              $ for node in $GROUP; do gnt-node modify -D yes $node; done
              $ for node in $GROUP; do gnt-node migrate -f --submit $node; done

       After maintenance, the tags would be removed and the nodes undrained.

   Offline Rolling node reboot output
       If all instances are shut down, usually larger node groups can be found.

              $ hroller --offline-maintainance -L
              'Node Reboot Groups'
              node1.example.com,node3.example.com,node5.example.com
              node8.example.com,node6.example.com,node2.example.com
              node7.example.com,node4.example.com

   Rolling reboots with non-redundant instances
       By default, hroller plans capacity to move the non-redundant instances out of the nodes to  be  rebooted.
       If  requested, apropriate locations for the non-redundant instances can be shown.  The assumption is that
       instances are moved back to their original node after each reboot; these back moves are not part  of  the
       output.

              $ hroller --print-moves -L
              'Node Reboot Groups'
              node-01-002,node-01-003
                inst-20 node-01-001
                inst-21 node-01-000
                inst-30 node-01-005
                inst-31 node-01-004
              node-01-004,node-01-005
                inst-40 node-01-001
                inst-41 node-01-000
                inst-50 node-01-003
                inst-51 node-01-002
              node-01-001,node-01-000
                inst-00 node-01-002
                inst-01 node-01-003
                inst-10 node-01-005
                inst-11 node-01-004

REPORTING BUGS

       Report  bugs  to  project  website (http://code.google.com/p/ganeti/) or contact the developers using the
       Ganeti mailing list (ganeti@googlegroups.com).

SEE ALSO

       Ganeti overview and  specifications:  ganeti(7)  (general  overview),  ganeti-os-interface(7)  (guest  OS
       definitions), ganeti-extstorage-interface(7) (external storage providers).

       Ganeti  commands:  gnt-cluster(8) (cluster-wide commands), gnt-job(8) (job-related commands), gnt-node(8)
       (node-related commands),  gnt-instance(8)  (instance  commands),  gnt-os(8)  (guest  OS  commands),  gnt-
       storage(8)  (storage commands), gnt-group(8) (node group commands), gnt-backup(8) (instance import/export
       commands), gnt-debug(8) (debug commands).

       Ganeti daemons: ganeti-watcher(8) (automatic instance restarter), ganeti-cleaner(8) (job queue  cleaner),
       ganeti-noded(8) (node daemon), ganeti-masterd(8) (master daemon), ganeti-rapi(8) (remote API daemon).

       Ganeti  htools: htools(1) (generic binary), hbal(1) (cluster balancer), hspace(1) (capacity calculation),
       hail(1) (IAllocator plugin), hscan(1) (data gatherer from remote clusters), hinfo(1) (cluster information
       printer), mon-collector(7) (data collectors interface).

COPYRIGHT

       Copyright (C) 2006, 2007, 2008, 2009, 2010, 2011, 2012  Google  Inc.   Permission  is  granted  to  copy,
       distribute  and/or  modify  under  the  terms  of the GNU General Public License as published by the Free
       Software Foundation; either version 2 of the License, or (at your option) any later version.

       On Debian systems, the complete text of the GNU General Public License can be found in /usr/share/common-
       licenses/GPL.

Ganeti                                                                                                HROLLER(1)