Provided by: netperfmeter_1.2.3-1_amd64 bug

NAME

       netperfmeter — Network Performance Meter

SYNOPSIS

       netperfmeter [Port]
       netperfmeter  [Destination:Port]  -local=Address[,Address,...] -runtime=Seconds -config=Name -scalar=Name
                    -vector=Name  -activenodename=Description   -passivenodename=Description   -quiet   -verbose
                    -verbosity=Level -tcp -mptcp -sctp -udp -dccp [FLOWSPEC] [...]

DESCRIPTION

       netperfmeter  is  a network performance meter for the UDP, TCP, MPTCP, SCTP and DCCP transport protocols.
       It simultaneously  transmits  bidirectional  flows  to  an  endpoint  and  measures  the  resulting  flow
       bandwidths. The results are written as vector and scalar files.

ARGUMENTS

       The following arguments have to be provided:

       Port    The port number for the passive side's data socket. The port number of the control socket will be
               port+1.  Specifying  a  port  number  turns  netperfmeter  in passive mode, i.e. it will wait for
               incoming connections.

       Destination:Port
               Specifies the destination endpoint to connect to. This will turn  netperfmeter  in  active  mode,
               i.e. it will connect to the specified remote endpoint.

       local=Address[,Address,...]
               Specifies  address(es)  of  the  local endpoint. For TCP, UDP and DCCP, only the first address is
               used!

       runtime
               Specifies the measurement runtime in seconds. After the given time span, netperfmeter will finish
               the measurement.

       config=Name
               Specifies the name of the configuration file to write. Default is output.config.

       vector=Name
               Specifies the name pattern of the vector files to write. If the suffix of this name is .bz2,  the
               file  will  be BZip2-compressed on the fly. The vector name is automatically extended to name the
               flow vector files by adding -<active|passive>-<flow_id>-<stream_id> before the  suffix.   Default
               is  vector.vec.bz2,  hence  the  name of the vector file for flow 5, stream 2 on the passive node
               will be vector-passive-00000005-0002.vec.bz2.

       scalar=Name
               Specifies the name pattern of the scalar files to write. If the suffix of this name is .bz2,  the
               file  will  be BZip2-compressed on the fly. The scalar name is automatically extended to name the
               flow scalar files by adding -<active|passive>-<flow_id>-<stream_id> before the  suffix.   Default
               is  scalar.vec.bz2,  hence  the  name of the scalar file for flow 5, stream 2 on the passive node
               will be scalar-passive-00000005-0002.vec.bz2.

       activenodename=Description
               Sets a textual description of the active node (e.g. Client).

       passivenodename=Description
               Sets a textual description of the passive node (e.g. Server).

       quiet   Reduces verbosity of log output. May be specified multiple times.

       verbose
               Increases verbosity of log output. May be specified multiple times.

       verbosity=Level
               Sets the verbosity of the log output to a given level, from 0 (lowest) to 6 (highest).

       sctp    Establish a new SCTP association. The streams of this association must be  specified  by  one  or
               more FLOWSPEC specifications as following parameters.

       tcp     Establish  a  new  TCP  or  MPTCP  connection. The flow of this connection must be specified by a
               FLOWSPEC specification as following parameter. MPTCP  support  in  NetPerfMeter  is  realized  as
               additional "MPTCP" socket (i.e. another TCP socket, but bound to another port number and with CMT
               enabled). That is, for MPTCP usage, it must contain the option cmt=mptcp (see below) to usage the
               MPTCP socket instead of the TCP socket.

       udp     Establish  a  new  UDP  connection.  The  flow of this connection must be specified by a FLOWSPEC
               specification as following parameter.

       dccp    Establish a new DCCP connection. The flow of this connection must  be  specified  by  a  FLOWSPEC
               specification  as  following  parameter.  Note,  that DCCP is not available on all platforms yet.
               Currently, only Linux provides DCCP in its official kernel.

       FLOWSPEC
               Specifies           a           new           flow.           The           format            is:
               outgoing_frame_rate:outgoing_frame_size:incoming_frame_size:incoming_frame_rate:option:...    The
               first                                       four                                       parameters
               (outgoing_frame_rate:outgoing_frame_size:incoming_frame_size:incoming_frame_rate:option)  may  be
               substituted by the option "default", creating a flow  with  some  more  or  less  useful  default
               parameters.

               outgoing_frame_rate
                       The  frame  rate  of  the outgoing transfer (i.e. active node to passive node). If set to
                       const0, the sender will be saturarted, i.e. it will try to send as much as possible.

               outgoing_frame_size
                       The frame size of the outgoing transfer (i.e. active node to passive  node).  If  set  to
                       const0, there will be *no* data transmission in this direction.

               incoming_frame_rate
                       The  frame  rate  of  the  incoming  transfer  (i.e.  passive  node  to active node). See
                       outgoing_frame_rate for details.

               incoming_frame_size
                       The frame size of  the  incoming  transfer  (i.e.  active  node  to  passive  node).  See
                       outgoing_frame_size for details.

               Possible options:

                       id=Flow Identifier
                               Sets an ID number for the flow. The IDs within a measurement must be unique!

                       description=Description
                               Sets a textual description of the flow (e.g. HTTP-Flow). Do not use spaces in the
                               description!

                       maxmsgsize=Bytes
                               Splits  frames  into  messages of at most the given number of bytes. Messages may
                               not exceed 65535 bytes.

                       defragtimeout=Milliseconds
                               Messages not received within this timeout after the  last  successfully  received
                               message  are accounted as lost. NOTE: this also happens if the transport protocol
                               is reliable and the message is actually received later!

                       unordered=Fraction
                               Specifies the fraction of the messages that will be sent in unordered mode  (SCTP
                               only).

                       ordered=Fraction
                               Specifies  the  fraction  of the messages that will be sent in ordered mode (SCTP
                               only).

                       reliable=Fraction
                               Specifies the fraction of the messages that will be sent in reliable  mode  (SCTP
                               only).

                       unreliable=Fraction
                               Specifies the fraction of the messages that will be sent in unreliable mode (SCTP
                               only).

                       rtx_timeout=Milliseconds
                               Sets the retransmission timeout for unreliable messages (SCTP only; not available
                               on all platforms!)

                       rtx_trials=Trials
                               Sets  the retransmission trials for unreliable messages (SCTP only; not available
                               on all platforms!)

                       rcvbuf=Bytes
                               Sets the receiver buffer size to the given number of bytes.

                       sndbuf=Bytes
                               Sets the sender buffer size to the given number of bytes.

                       onoff=t1,t2,...
                               A list of time stamps when the flow should be activated or deactivated. If  onoff
                               is given, the flow is off at startup. At t1, it will be turned on; at t2, it will
                               be  turned  off,  etc..  Time  stamps  can  be  given  as  absolute  values (e.g.
                               onoff=0,10,30 - to turn on at t=0, turn off at t=10 and turn  on  again  at  t=30
                               until  end of measurement) or relative values (e.g. on=10,+30,+60 - to turn on at
                               t=10, turn off at t=40 and turn on again at t=100 until end of measurement).

                       error_on_abort=on|off
                               By default, the active side stops with an error when a transmission  tails  (e.g.
                               on connection abort). This parameter turns this behaviour on or off.

                       cmt=off|cmt|cmtrpv1|cmtrpv2|like-mptcp|mptcp-like|mptcp
                               Configures  usage  of  Concurrent  Multipath  Transfer  (CMT):  off  (turned off;
                               default),  cmt  (independent  paths),  cmtrpv1  (CMT/RPv1),  cmtrpv1  (CMT/RPv2),
                               mptcp/like-mptcp/mptcp-like   (MPTCP),  0-255  (custom  value).   Currently  only
                               supported by CMT-SCTP on FreeBSD systems and MPTCP on Linux  systems.  Note:  CMT
                               for MPTCP always uses MPTCP congestion control.

EXAMPLES

       Some netperfmeter usage examples:

       netperfmeter 9000
               Start in passive mode, i.e. accepting connections, on port 9000.

       netperfmeter       172.16.255.254:9000      -vector=output.vec.bz2      -scalar=output.sca.bz2      -sctp
               const5:exp1000:const3:exp500:description="Alpha":onoff=+10
               const5:exp1000:const3:exp500:description="Beta":onoff=+30                                    -tcp
               const5:exp1000:const3:exp500:description="Gamma":onoff=+60 -runtime=300
               Start  in  active  mode,  i.e. establish connection to 172.16.255.254, port 9000.  Frames will be
               segmented into messages of up to 4096 bytes.  Write vectors to output.vec.bz2 (BZip2-compressed).
               Write scalars to output.sca.bz2 (BZip2-compressed).  Establish SCTP association.  At t=10s, start
               flow "Alpha" as first stream of this association, using a frame rate of 5 (constant) and  average
               frame  size  of  1000 bytes (negative exponential distribution) for the outgoing data and a frame
               rate of 3 (constant) and average frame size of 500 bytes (negative exponential distribution)  for
               the  incoming  data.   At t=30s, start flow "Beta" as second stream on the SCTP association (same
               parameters as flow "Alpha").  Start TCP connection.  At t=60s, start flow "Gamma"  over  the  TCP
               connection (same parameters as flow "Alpha").  At t=300s, stop the measurement.

AUTHORS

       Thomas Dreibholz
       http://www.iem.uni-due.de/~dreibh/netperfmeter
       mailto://dreibh@iem.uni-due.de

netperfmeter                                    October 28, 2011                                 netperfmeter(1)