Provided by: wavemon_0.7.6-2_amd64 bug

NAME

       $HOME/.wavemonrc - wavemon configuration file

DESCRIPTION

       wavemonrc  is  the  per-user  configuration  file for wavemon(1).  This page describes its
       individual configuration options.   Each  corresponds  to  a  configuration  item  of  the
       Preferences screen (F7 key), whose on-screen name is shown in parentheses.

       interface = <ifname>
       (Interface)
              Selects the wireless interface to use.

       cisco_mac = (on|off)
       (Cisco-style MAC addresses)
              If  enabled,  display  MAC  addresses using lower-case hex digits separated by dots
              rather than colons.

       sort_order = (channel|essid|signal|open|chan/sig|open/sig)
       (Scan sort type)
              Determines the ordering used in the scan window: channel sorts by  channel  number,
              essid  by  access  point name, signal by signal strength, and open by openness. The
              combined variants chan/sig and open/sig sort first by channel/openness and then  by
              signal  strength.  It also affects the status line at the bottom: normally the most
              crowded channels are listed, sorting by channel in  descending  order  switches  to
              least crowded ones instead.

       sort_ascending = (on|off)
       (Scan sort direction)
              Sets the direction of the sort_order: ascending (on) or descending (off).

       stat_updates = <n>
       (Statistics updates)
              Time   interval  for  polling  new  statistics  (including  scan  refresh).  Range:
              10..4000ms.

       lhist_slot_size = <n>
       (Histogram update cycles)
              Number of samples used per each histogram slot. For example,  if  the  stat_updates
              interval is 500ms and the histogram slot size is 4, the histogram is moved one slot
              further every 2 seconds. Range: 1..64.

       meter_smoothness = <n>
       (Level meter smoothness)
              Determines the responsiveness of level meters, tracking the moving  average  rather
              than  following  each  new  sample. The given value specifies the percentage of the
              history (the 'inertia') of preceding samples. A value of 0  disables  this  option.
              Range: 0..99%.

       info_updates = <n>
       (Dynamic info updates)
              Sets  refresh  rate  for  dynamic  device parameters (e.g. bitrate) and the refresh
              interval for the Scan window (F3). Range: 1..60s.

       override_auto_scale = (on|off)
       (Override scale autodetect)
              Override the auto-scaling of the bar graphs and histogram, allowing you to set your
              own scales.

       min_signal_level, max_signal_level = <n>
       (Minimum signal level, Maximum signal level)
              Set  the left and right boundaries of the signal level scales. Ranges: -128..-60dBm
              (minimum) and -59..120dBm (maximum).

       min_noise_level, max_noise_level = <n>
       (Minimum noise level, Maximum noise level)
              These work similar to the signal boundary settings. Ranges: -128..-60dBm  (minimum)
              and -60..120dBm (maximum).

       random = (on|off)
       (Random signals)
              Switches on a fancy random generator for testing.

       lo_threshold_action = (disabled|beep|flash|beep+flash)
       (Low threshold action)
              Issue  a  warning  at a given threshold at the lower end of the signal scale. It is
              meant for alarming you when a signal appears at the receiver.

       lo_threshold = <n>
       (Low threshold)
              Sets the threshold value for the 'Low threshold action'.  Range: -120..-60dBm.

       hi_threshold_action = (disabled|beep|flash|beep+flash)
       (High threshold action)
              Analogous to lo_threshold_action, only this time the threshold is at the upper  end
              of  the scale and the action is performed when the signal level drops below it. The
              acoustic signal is also different in order to be easily  distinguishable  from  the
              lower  one.  Correctly  adjusted,  this little fellow will tell you when you should
              move closer to the base station.

       hi_threshold = <n>
       (High threshold)
              Sets the threshold for the 'High threshold action'. Range: -59..120dBm.

       startup_screen = (info|histogram|scan window)
       (Startup screen)
              Which of the screens appears at program startup.

AUTHOR

       Written by Jan Morgenstern <jan@jm-music.de>.

REPORTING BUGS

       Send bug reports and/or suggestions to Gerrit Renker <gerrit@erg.abdn.ac.uk>.

COPYRIGHT

       This is free software with ABSOLUTELY NO WARRANTY. See file COPYING for details.