Provided by: aegis_4.24.3-3_amd64
NAME
aegis new test undo - remove new tests from a change
SYNOPSIS
aegis -New_Test_Undo file-name... [ option... ] aegis -New_Test_Undo -List [ option... ] aegis -New_Test_Undo -Help
DESCRIPTION
The aegis -New_Test_Undo command is used to remove new tests from a change (reverse the actions of the 'aegis -New_Test' command). The file is removed from the development directory. You may specify a directory name to remove all new tests in the named directory tree, other files in the tree will be ignored. It is an error if there are no relevant files. File Name Interpretation The aegis program will attempt to determine the project file names from the file names given on the command line. All file names are stored within aegis projects as relative to the root of the baseline directory tree. The development directory and the integration directory are shadows of this baseline directory, and so these relative names apply here, too. Files named on the command line are first converted to absolute paths if necessary. They are then compared with the baseline path, the development directory path, and the integration directory path, to determine a baseline-relative name. It is an error if the file named is outside one of these directory trees. The -BAse_RElative option may be used to cause relative filenames to be interpreted as relative to the baseline path; absolute filenames will still be compared with the various paths in order to determine a baseline-relative name. The relative_filename_preference in the user configuration file may be used to modify this default behavior. See aeuconf(5) for more information. Notification The new_test_undo_command in the project config file is run, if set. The project_file_‐ command is also run, if set, and if there has been an integration recently. See aepconf(5) for more information. Process Side Effects This command will cancel any build or test registrations, because deleting a file logically invalidates them.
OPTIONS
The following options are understood: -BAse_RElative This option may be used to cause relative filenames to be considered relative to the base of the source tree. See aeuconf(5) for the corresponding user preference. -CUrrent_RElative This option may be used to cause relative filenames to be considered relative to the current directory. This is usually the default. See aeuconf(5) for the corresponding user preference. -Change number This option may be used to specify a particular change within a project. See aegis(1) for a complete description of this option. -Help This option may be used to obtain more information about how to use the aegis program. -Interactive Specify that aegis should ask the user for confirmation before deleting each file. Answer the question yes to delete the file, or no to keep the file. You can also answer all to delete the file and all that follow, or none to keep the file and all that follow. Defaults to the user's delete_file_preference if not specified, see aeuconf(5) for more information. If aegis is running in the background, the question will not be asked, and the files will be deleted. -Keep This option may be used to retain files and/or directories usually deleted or replaced by the command. Defaults to the user's delete_file_preference if not specified, see aeuconf(5) for more information. -No_Keep This option may be used to ensure that the files and/or directories are deleted or replaced by the command. Defaults to the user's delete_file_preference if not specified, see aeuconf(5) for more information. -List This option may be used to obtain a list of suitable subjects for this command. The list may be more general than expected. -Not_Logging This option may be used to disable the automatic logging of output and errors to a file. This is often useful when several aegis commands are combined in a shell script. -Project name This option may be used to select the project of interest. When no -Project option is specified, the AEGIS_PROJECT environment variable is consulted. If that does not exist, the user's $HOME/.aegisrc file is examined for a default project field (see aeuconf(5) for more information). If that does not exist, when the user is only working on changes within a single project, the project name defaults to that project. Otherwise, it is an error. -TERse This option may be used to cause listings to produce the bare minimum of information. It is usually useful for shell scripts. -Verbose This option may be used to cause aegis to produce more output. By default aegis only produces output on errors. When used with the -List option this option causes column headings to be added. -Verify_Symbolic_Links This option may be used to request that the symbolic links, or hard links, or file copies, in the work area be updated to reflect the current state of the baseline. This is controlled by the development_directory_style field of the project configuration file. Only files which are not involved in the change are updated. See also the “symbolic_links_preference” field of aeuconf(5). This option is the default, if meaningful for your configuration. The name is an historical accident, hard links and file copies are included. -Assume_Symbolic_Links This option may be used to request that no update of baseline mirror files take place. This options is useful when you definitely know the files' up-to-date- ness isn't important right now; incorrect use of this option may have unanticipated build side-effects. See also the “symbolic_links_preference” field of aeuconf(5). This option is the default, if not meaningful for your configuration. The name is an historical accident, hard links and file copies are included. -Wait This option may be used to require Aegis commands to wait for access locks, if they cannot be obtained immediately. Defaults to the user's lock_wait_preference if not specified, see aeuconf(5) for more information. -No_Wait This option may be used to require Aegis commands to emit a fatal error if access locks cannot be obtained immediately. Defaults to the user's lock_wait_preference if not specified, see aeuconf(5) for more information. See also aegis(1) for options common to all aegis commands. All options may be abbreviated; the abbreviation is documented as the upper case letters, all lower case letters and underscores (_) are optional. You must use consecutive sequences of optional letters. All options are case insensitive, you may type them in upper case or lower case or a combination of both, case is not important. For example: the arguments "-project, "-PROJ" and "-p" are all interpreted to mean the -Project option. The argument "-prj" will not be understood, because consecutive optional characters were not supplied. Options and other command line arguments may be mixed arbitrarily on the command line, after the function selectors. The GNU long option names are understood. Since all option names for aegis are long, this means ignoring the extra leading '-'. The "--option=value" convention is also understood.
RECOMMENDED ALIAS
The recommended alias for this command is csh% alias aentu 'aegis -ntu \!$ -v' sh$ aentu(){aegis -ntu "$@" -v}
ERRORS
It is an error if the change is not in the being developed state. It is an error if the change is not assigned to the current user. It is an error if the file is not in the change. It is an error if the file was not added to the change with the 'aegis -New_Test' command.
EXIT STATUS
The aegis command will exit with a status of 1 on any error. The aegis command will only exit with a status of 0 if there are no errors.
ENVIRONMENT VARIABLES
See aegis(1) for a list of environment variables which may affect this command. See aepconf(5) for the project configuration file's project_specific field for how to set environment variables for all commands executed by Aegis.
SEE ALSO
aent(5) add a new test to a change aeuconf(5) user configuration file format
COPYRIGHT
aegis version 4.24.3.D001 Copyright (C) 1991, 1992, 1993, 1994, 1995, 1996, 1997, 1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010 Peter Miller The aegis program comes with ABSOLUTELY NO WARRANTY; for details use the 'aegis -VERSion License' command. This is free software and you are welcome to redistribute it under certain conditions; for details use the 'aegis -VERSion License' command.
AUTHOR
Peter Miller E-Mail: millerp@canb.auug.org.au /\/\* WWW: http://www.canb.auug.org.au/~millerp/