As from siggen version 2.3 onwards a versatile configuration file
scheme has been introduced. It allows parameters for the siggen programs to
be specified either across the board, or specifically for particular
programs.
Three possible configuration files can be used: a LOCAL config
file (usually in current directory), a HOME config file in user's $HOME
directory and a GLOBAL config file.
All the programs are compiled with the names of the config files
built in. The filenames are set in the config.h header file and can be
changed. The LOCAL and GLOBAL config files are specified by the settings
of:
- LOCAL
- #define DEF_CONF_FILENAME ".siggen.conf"
- GLOBAL
- #define DEF_GLOBAL_CONF_FILE "/etc/siggen.conf"
And can be set to any file name or to NULL to disable the file.
The HOME config filename is created using the $HOME environment variable and
the DEF_CONF_FILENAME together, i.e. using the above, the HOME config file
for a user whose home directory is at /home/jj, would be
- HOME
- /home/jj/.siggen.conf
The config files do not have to exist. If they exist and are
readable by the program they are used, otherwise they are simply
ignored.
The config files are always searched for configuration values in
the order LOCAL, HOME, GLOBAL. This allows a scheme where the sysadmin sets
up default config values in the GLOBAL config file, but allows a user to set
some or all different values in their own HOME config file, and to set yet
more specific values when run from a particular directory.
If no configuration files exist, the programs themselves provide
builtin default values (see config.h etc), and most of these values can be
set by appropriate command line switches and flags.
A configuration value has a name and a value, and values for all
programs are set by simply entering a line in the appropriate config file
where the first word is the name, followed by arbitrary spaces/tabs,
followed by the value. The value is all the rest of that line. e.g. to set
the global default samplerate of 44100 samples per sec, the following line
would be entered in the GLOBAL config file:
- SAMPLERATE 44100
Config value names are case insensitive.
A config value can be set for a specific program, by prefixing the
config value name with the program name and a ':'. e.g. to specify a
samplerate of only 8000 samples per sec for the tones program enter
- TONES:SAMPLERATE 8000
-
in the relevant config file. If both lines above were in the
config file, all programs except tones would use a samplerate of 44100, and
tones would use 8000.
You do not have to specify all configuration values in the config
files. If a particular value is missing, the programs will simply use their
builtin defaults (see config.h etc).
Configuration values set by command line switches or flags take
precedence over values in any of the config files.
- Beware
- the programs do not have their 'name' built-in, but use the name they were
invoked by. So if you change the name of a program, remember to change the
config file entries. However this does means that by using links to a
program, it can be made to pick up a different set of configuration
values, depending on the name it is invoked by.
A sample config file is provided in ".siggen.conf" in
the distribution. This may also be at /etc/siggen.conf . Any line whose
first non-whitespace character is a '#', is a comment line and is
ignored.
Not all of the siggen programs use all the values described here.
See the relevant man page for which values are used by which programs.
- CHANNELS
- In all programs except tones and fsynth, channels specifies the number of
output channels to use, i.e. 1 for Mono and 2 for Stereo.
- For tones, channels specifies the number of 'voices' on which tones can
generate different waveforms before mixing them into the one output
channel.
- For fsynth, channels specifies the numbers of separately configurable
oscillators used to mix the single output channel.
- DACFILE
- The Digital to Analogue Converter (or PCM or DSP) device on which to
output the generated samples. This must be a real OSS PCM device,
otherwise the ioctls used will fail.
- FRAGMENTS
- The number of Audio Buffer fragments to configure in the driver. The
interactive programs respond to changes made to parameters from the
keyboard immediately, but data will be buffered in the driver in the
buffer fragments. If the amount of data buffered is too much then there
will very noticeable delays before the output sound is altered. Against
that, insufficient buffering may mean that there is not enough data
buffered for output to cover the time when other processes are being run
by the scheduler. The programs set the buffer size to the nearest power of
2 to give aprox. 100millisecs of sound. Hence if FRAGMENTS is set to 3,
there will be aprox. 0.3 secs worth of sound buffered for output. On a
lightly loaded fast machine this, or 2, should be sufficient. To cover
periods of heavy load or on a less powerful machine use 4 or 5. But
remember the interactive programs will appear sluggish in responding to
the keyboard.
- SAMPLERATE
- The number of samples per second to use. If output is to the DAC then the
DAC device is set to output samples at this rate.
BEWARE: not all cards can support all samplerates. SoundBlasters are
fairly flexible in this respect. Other cheaper cards are not. Indeed some
cards can only handle a very restricted set of related samplerates e.g.
11025, 22050, 44100 & 8000, 16000, 32000, 48000. When writing to
DACFILE all programs will attempt to set the samplerate given, but use the
actual samplerate the device used. Use the verbose command line flag to
check actual samplerates used.
Some common samplerates used are:
- 8000
- is the samplerate used in the phone system with 8 bit samples, and is
adequate for voice range frequencies.
- 44100
- is the samplerate used in audio CDs
- 48000
- is the samplerate used in DAT systems, I think, and for much professional
kit.
- 32000
- is also used, but I forget where, minidisc?.
- In general, the higher the samplerate the larger the memory and processing
requirement, but the higher the frequency range and the more accurate the
signals generated.
- SAMPLESIZE
- Number of bits per sample. Only two values are allowed currently, 8 or
16.
- 8
- bit samples are unsigned, with decimal value 128 being the
´zero´ level.
- 16
- bit samples are signed little endian values, i.e. the least significant
byte comes before the most significant byte either in a file, or in the
byte stream to an output device.
- If samplesize if left completely unspecified, then all programs will
attempt to do 16 bit samples to DACFILE, and if that isn't possible will
do 8 bit samples. Or if writing to a file, 16 bit samples will be written.
- VERBOSE
- sets verbosity level.
- 0
- is quiet
- 1
- is be a bit verbose (equiv. to -v switch)
- 2
- is be very verbose (equiv. to -vv switch)
- VI_KEYS
- if set to a non-zero value, then the VI cursor moving keys
"HJKL" are enabled.
Copyright 1995-2008 Jim Jackson
The software described by this manual is covered by the GNU
General Public License, Version 2, June 1991, issued by :
- Free Software Foundation, Inc.,
675 Mass Ave,
Cambridge, MA 02139, USA
Permission is granted to make and distribute verbatim copies of
this manual provided the copyright notice and this permission notice are
preserved on all copies.
Permission is granted to copy and distribute modified versions of
this manual under the conditions for verbatim copying, provided that the
entire resulting derived work is distributed under the terms of a permission
notice identical to this one.
Permission is granted to copy and distribute translations of this
manual into another language, under the above conditions for modified
versions, except that this permission notice may be included in translation
instead of in the original English.
Jim Jackson
Email: jj@franjam.org.uk