Provided by: infiniband-diags_1.6.1-1ubuntu2_amd64 bug

NAME

       IBSYSSTAT -

system status on an InfiniBand address

   SYNOPSIS
       ibsysstat [options] <dest lid | guid> [<op>]

   DESCRIPTION
       ibsysstat  uses  vendor  mads  to  validate connectivity between IB nodes and obtain other
       information about the IB node. ibsysstat is run as client/server. Default  is  to  run  as
       client.

   OPTIONS
       Current supported operations:

       ::     ping  - verify connectivity to server (default) host - obtain host information from
              server cpu  - obtain cpu information from server

       -o, --oui

              use specified OUI number to multiplex vendor mads

       -S, --Server

              start in server mode (do not return)

   Addressing Flags
       -G, --Guid     The address specified is a Port GUID

       -L, --Lid   The address specified is a LID

       -s, --sm_port <smlid>     use 'smlid' as the target lid for SA queries.

   Port Selection flags
       -C, --Ca <ca_name>    use the specified ca_name.

       -P, --Port <ca_port>    use the specified ca_port.

   Local port Selection
       Multiple port/Multiple CA support: when no IB device or port is specified (see the  "local
       umad  parameters"  below),  the libibumad library selects the port to use by the following
       criteria:

          1. the first port that is ACTIVE.

          2. if not found, the first port that is UP (physical link up).

          If a port and/or CA name is specified, the libibumad library attempts  to  fulfill  the
          user request, and will fail if it is not possible.

          For example:

          ibaddr                 # use the first port (criteria #1 above)
          ibaddr -C mthca1       # pick the best port from "mthca1" only.
          ibaddr -P 2            # use the second (active/up) port from the first available IB device.
          ibaddr -C mthca0 -P 2  # use the specified port only.

   Debugging flags
       -d     raise the IB debugging level.  May be used several times (-ddd or -d -d -d).

       -e     show send and receive errors (timeouts and others)

       -h, --help      show the usage message

       -v, --verbose

              increase  the application verbosity level.  May be used several times (-vv or -v -v
              -v)

       -V, --version     show the version info.

   Configuration flags
       -t, --timeout <timeout_ms> override the default timeout for the solicited mads.

       --config, -z  <config_file> Specify alternate config file.

          Default: /etc/infiniband-diags/ibdiag.conf

   FILES
   CONFIG FILE
       /etc/infiniband-diags/ibdiag.conf

       A global config file is provided to set some of the common options  for  all  tools.   See
       supplied config file for details.

   AUTHOR
       Hal Rosenstock
              < halr@voltaire.com >

                                                                                     IBSYSSTAT(8)