xenial (1) PCPIntro.1.gz

Provided by: pcp_3.10.8build1_amd64 bug

NAME

       PCPIntro - introduction to the Performance Co-Pilot (PCP)

INTRODUCTION

       The  Performance  Co-Pilot  (PCP)  is  a  toolkit  designed  for  monitoring  and  managing  system-level
       performance.  These services are  distributed  and  scalable  to  accommodate  the  most  complex  system
       configurations and performance problems.

       PCP supports many different platforms, including (but not limited to) Linux, MacOSX, Solaris and Windows.
       From a high-level PCP can be considered to contain two classes of software utility:

       PCP Collectors
               These are the parts of PCP that collect and extract performance data from various  sources,  e.g.
               the operating system kernel.

       PCP Monitors
               These are the parts of PCP that display data collected from hosts (or archives) that have the PCP
               Collector installed.  Many monitor tools are available as part of the  core  PCP  release,  while
               other (typically graphical) monitoring tools are available separately in the PCP GUI package.

       This manual entry describes the high-level features and options common to most PCP utilities available on
       all platforms.

OVERVIEW

       The PCP architecture is distributed in the sense that any PCP tool may be  executing  remotely.   On  the
       host (or hosts) being monitored, each domain of performance metrics, whether the kernel, a service layer,
       a database management system, a web server, an application,  etc.  requires a Performance Metrics  Domain
       Agent  (PMDA)  which  is responsible for collecting performance measurements from that domain.  All PMDAs
       are controlled by the Performance Metrics Collector Daemon (pmcd(1)) on the same host.

       Client applications (the monitoring tools) connect to pmcd(1), which acts as a router  for  requests,  by
       forwarding requests to the appropriate PMDA and returning the responses to the clients.  Clients may also
       access performance data from a PCP archive (created using pmlogger(1)) for retrospective analysis.

   Security philosophy
       PCP redistributes a wealth of performance information  within  a  host  and  across  its  networks.   The
       following security philosophy underlies the setting of several defaults that control how much information
       is sent and received.

       By default, the information exposed by  PMCD  about  a  host  is  approximately  of  the  same  level  of
       confidentiality  as  available to a completely unprivileged user on that host.  So, performance data that
       is available to be read completely freely on a machine may be made available by PMCD to the network.

       However, the host running PMCD and its  network  is  not  assumed  to  run  only  friendly  applications.
       Therefore, write type operations, including from the local host, are not permitted by default.

       These  defaults  may be overridden (expanded or reduced) in several ways, including by specifying network
       ACLs in pmcd.conf, activating non-default PMDAs, or by using PMCD connections that pass user credentials.
       For  example,  some  PMDAs automatically provide greater information for particular credentialed users or
       groups.

   Applications
       The following performance monitoring applications are primarily console  based,  typically  run  directly
       from  the  command  line,  and  are  just  a  small subset of the tools available as part of the base PCP
       package.

       Each tool or command is documented completely in its own reference page.

       pmstat Outputs an ASCII high-level summary of system performance.

       pmie   An inference engine that can evaluate predicate-action rules to perform alarms and automate system
              management tasks.

       pminfo Interrogate specific performance metrics and the metadata that describes them.

       pmlogger
              Generates PCP archives of performance metrics suitable for replay by most PCP tools.

       pmval  Simple  periodic  reporting  for  some or all instances of a performance metric, with optional VCR
              time control.

       If the PCP GUI package is installed then the following additional tools are available.

       pmchart
              Displays trends over time of arbitrarily selected performance metrics from one or more hosts.

       pmtime Time control utility for coordinating the time  between  multiple  tools  (including  pmchart  and
              pmval).

       pmdumptext
              Produce ASCII reports for arbitrary combinations of performance metrics.

COMMON COMMAND LINE ARGUMENTS

       There is a set of common command line arguments that are used consistently by most PCP tools.

       -a archive
              Performance  metric  information  is retrospectively retrieved from the Performance Co-Pilot (PCP)
              archive, previously generated by pmlogger(1).See pcp-archive(5)forformatdocumentation.  The -a and
              -h options are mutually exclusive.

              archive  is  either  the  base  name common to all of the physical files created by an instance of
              pmlogger(1), or any one of the physical files, e.g.  myarchive (base name) or myarchive.meta  (the
              metadata  file)  or  myarchive.index (the temporal index) or myarchive.0 (the first data volume of
              archive) or myarchive.0.bz2 or myarchive.0.bz (the first data volume compressed with bzip2(1))  or
              myarchive.0.gz  or myarchive.0.Z or myarchive.0.z (the first data volume compressed with gzip(1)),
              myarchive.1 or myarchive.3.bz2 or myarchive.42.gz etc.

       -a archive[,archive,...]
              An alternate form of -a for applications that are able to handle multiple archives.

       -h hostname
              Unless directed to another host by the -h option, or to an archive by the -a option, the source of
              performance  metrics  will  be  the Performance Metrics Collector Daemon (PMCD) on the local host.
              Refer to the PMCD HOST SPECIFICATION section  later  for  further  details  on  the  many  options
              available  when  forming  the  hostname  specification,  as  well as a detailed description of the
              default local host connection.  The -a and -h options are mutually exclusive.

       -s samples
              The argument samples defines the number of samples to be retrieved and reported.  If samples is  0
              or -s is not specified, the application will sample and report continuously (in real time mode) or
              until the end of the PCP archive (in archive mode).

       -z     Change the reporting timezone to the local timezone  at  the  host  that  is  the  source  of  the
              performance metrics, as identified via either the -h or -a options.

       -Z timezone
              By  default,  applications  report  the  time of day according to the local timezone on the system
              where the application is executed.  The -Z option changes the timezone to timezone in  the  format
              of the environment variable TZ as described in environ(7).

INTERVAL SPECIFICATION AND ALIGNMENT

       Most  PCP  tools  operate  with  periodic sampling or reporting, and the -t and -A options may be used to
       control the duration of the sample interval and the alignment of the sample times.

       -t interval
              Set the update or reporting interval.

              The interval argument is specified as a sequence of one or more elements of the form
                        number[units]
              where number is an integer or floating point constant (parsed using strtod(3))  and  the  optional
              units  is  one  of:  seconds, second, secs, sec, s, minutes, minute, mins, min, m, hours, hour, h,
              days, day and d.  If the unit is empty, second is assumed.

              In addition, the upper case (or mixed case) version of any of the above is also acceptable.

              Spaces anywhere in the interval are ignored, so 4 days 6 hours 30 minutes, 4day6hour30min, 4d6h30m
              and 4d6.5h are all equivalent.

              Multiple  specifications  are additive, e.g. ``1hour 15mins 30secs'' is interpreted as 3600+900+30
              seconds.

       -A align
              By default samples are not necessarily aligned on any natural unit of time.  The -A option may  be
              used  to  force  the  initial  sample  to  be aligned on the boundary of a natural time unit.  For
              example -A 1sec, -A 30min and -A 1hour specify alignment on whole seconds, half  and  whole  hours
              respectively.

              The align argument follows the syntax for an interval argument described above for the -t option.

              Note  that  alignment  occurs by advancing the time as required, and that -A acts as a modifier to
              advance both the start of the time window (see the next section) and the origin time  (if  the  -O
              option is specified).

TIME WINDOW SPECIFICATION

       Many PCP tools are designed to operate in some time window of interest, e.g. to define a termination time
       for real-time monitoring or to define a start and end time within a PCP archive log.

       In the absence of the -O and -A options to specify an initial sample time origin and time alignment  (see
       above), the PCP application will retrieve the first sample at the start of the time window.

       The following options may be used to specify a time window of interest.

       -S starttime
              By  default the time window commences immediately in real-time mode, or coincides with time at the
              start of the PCP archive log in archive mode.  The -S option may be used to specify a  later  time
              for the start of the time window.

              The  starttime  parameter  may  be given in one of three forms (interval is the same as for the -t
              option as described above, datetime is described below):

              interval
                     To specify an offset from the current time (in real-time mode) or the beginning  of  a  PCP
                     archive (in archive mode) simply specify the interval of time as the argument.  For example
                     -S 30min will set the start of the time window to be exactly 30 minutes from now  in  real-
                     time mode, or exactly 30 minutes from the start of a PCP archive.

              -interval
                     To specify an offset from the end of a PCP archive log, prefix the interval argument with a
                     minus sign.  In this case, the start of the time window precedes the time  at  the  end  of
                     archive by the given interval.  For example -S -1hour will set the start of the time window
                     to be exactly one hour before the time of the last sample in a PCP archive log.

              @datetime
                     To specify the calendar date and time (local time in the reporting timezone) for the  start
                     of  the time window, use the datetime syntax preceded by an at sign.  Refer to the datetime
                     description below for detailed information.

       -T endtime
              By default the end of the time window is unbounded (in real-time mode) or aligned with the time at
              the  end  of a PCP archive log (in archive mode).  The -T option may be used to specify an earlier
              time for the end of the time window.

              The endtime parameter may be given in one of three forms (interval is  the  same  as  for  the  -t
              option as described above, datetime is described below):

              interval
                     To  specify  an offset from the start of the time window simply use the interval of time as
                     the argument.  For example -T 2h30m will set the end of the time window to be 2  hours  and
                     30 minutes after the start of the time window.

              -interval
                     To  specify  an  offset  back  from  the  time  at the end of a PCP archive log, prefix the
                     interval argument with a minus sign.  For example -T -90m will set  the  end  of  the  time
                     window to be 90 minutes before the time of the last sample in a PCP archive log.

              @datetime
                     To specify the calendar date and time (local time in the reporting timezone) for the end of
                     the time window, use the datetime syntax preceded by an at sign.   Refer  to  the  datetime
                     description below for detailed information.

       -O origin
              By default samples are fetched from the start of the time window (see description of -S option) to
              the end of the time window (see description of -T option).  The -O option allows the specification
              of  an  origin  within  the time window to be used as the initial sample time.  This is useful for
              interactive use of a PCP tool with the pmtime(1) VCR replay facility.

              The origin argument accepted by -O conforms to the same syntax  and  semantics  as  the  starttime
              argument for the -T option.

              For  example  -O  -0  specifies that the initial position should be at the end of the time window;
              this is most useful when wishing to replay ``backwards'' within the time window.

       The datetime argument for the -O, -S and -T options consists of:
                 date time zone day relative
       A date can be one of: YY-MM-DD, MM/DD/YY, DD Month YYYY, or Month  DD  YYYY.   A  time  can  be  one  of:
       HH:MM:SS, HH:MM.  HH:MM can use either the 12 hour (via an am or pm suffix) or 24 hour convention.  A day
       of the week can be a spelled out day of the week, optionally preceded by an ordinal number such as second
       tuesday.   A zone is a time zone value as specified by the tzselect(1) command.  A relative time can be a
       time unit that is: preceded by a cardinal number such as 1 year or 2 months, preceded by one of the  time
       words  this  or  last,  or  succeeded  by the time word ago.  A relative time can also be one of the time
       words: yesterday, today, tomorrow, now.  Examples of datetime strings are: 1996-03-04 13:07:47  EST  Mon,
       1996-03-05 14:07:47 EST -1hour, Mon Mar  4 13:07:47 1996, Mar 4 1996, Mar 4, Mar, 13:07:50 or 13:08.

       For any missing low order fields, the default value of 0 is assumed for hours, minutes and seconds, 1 for
       day of the month and Jan for months.  Hence, the following are equivalent: -S '@ Mar 1996' and -S '@  Mar
       1 00:00:00 1996'.

       If  any  high  order fields are missing, they are filled in by starting with the year, month and day from
       the current time (real-time mode) or the time at the beginning of the PCP archive log (archive mode)  and
       advancing  the  time  until it matches the fields that are specified.  So, for example if the time window
       starts by default at ``Mon Mar 4 13:07:47 1996'', then -S @13:10 corresponds to 13:10:00 on  Mon  Mar  4,
       1996, while -S @10:00 corresponds to 10:00:00 on Tue Mar 5, 1996 (note this is the following day).

       For greater precision than afforded by datetime(3), the seconds component may be a floating point number.

PERFORMANCE METRICS - NAMES AND IDENTIFIERS

       The  number  of  performance metric names supported by PCP on most platforms ranges from many hundreds to
       several thousand.  The PCP  libraries  and  applications  use  an  internal  identification  scheme  that
       unambiguously  associates  a single integer with each known performance metric.  This integer is known as
       the Performance Metric Identifier, or PMID.  Although not  a  requirement,  PMIDs  tend  to  have  global
       consistency across all systems, so a particular performance metric usually has the same PMID.

       For  all  users  and  most  applications, direct use of the PMIDs would be inappropriate (e.g. this would
       limit the range of accessible metrics, make the code hard to maintain, force the  user  interface  to  be
       particularly  baroque,  etc.).  Hence a Performance Metrics Name Space (PMNS) is used to provide external
       names and a hierarchic classification for performance metrics.  A PMNS is represented  as  a  tree,  with
       each node having a label, a pointer to either a PMID (for leaf nodes) or a set of descendent nodes in the
       PMNS (for non-leaf nodes).

       A node label must begin with an alphabetic character, followed by zero or more characters drawn from  the
       alphabetics, the digits and character `_´ (underscore).  For alphabetic characters in a node label, upper
       and lower case are distinguished.

       By convention, the name of a performance metric is constructed by concatenation of the node labels  on  a
       path  through  the PMNS from the root node to a leaf node, with a ``.'' as a separator.  The root node in
       the PMNS is unlabeled, so all names begin with the label associated with  one  of  the  descendent  nodes
       below  the  root  node  of  the  PMNS,  e.g.  kernel.percpu.syscall.   Typically  (although this is not a
       requirement) there would be at most one name for each PMID in a PMNS.   For  example  kernel.all.cpu.idle
       and disk.dev.read are the unique names for two distinct performance metrics, each with a unique PMID.

       Groups of related PMIDs may be named by naming a non-leaf node in the PMNS tree, e.g. disk.

       The default local PMNS used by pmcd is located at $PCP_VAR_DIR/pmns/root however the environment variable
       PMNS_DEFAULT may be set to the full pathname of a different PMNS which will then be used as  the  default
       local PMNS.

       Most  applications  do  not  use the local PMNS directly, but rather import parts of the PMNS as required
       from the same place that performance metrics are fetched, i.e. from pmcd(1) for live monitoring or from a
       PCP archive for retrospective monitoring.

       To explore the PMNS use pminfo(1), or if the PCP GUI package is installed the New Chart and Metric Search
       windows within pmchart(1).

PERFORMANCE METRIC SPECIFICATIONS

       In configuration files and (to a lesser extent) command line options, metric specifications adhere to the
       following syntax rules.

       If the source of performance metrics is real-time from pmcd(1) then the accepted syntax is
                 host:metric[instance1,instance2,...]

       If the source of performance metrics is a PCP archive log then the accepted syntax is
                 archive/metric[instance1,instance2,...]

       The host:, archive/ and [instance1,instance2,...]  components are all optional.

       The , delimiter in the list of instance names may be replaced by white space.

       Special characters in instance names may be escaped by surrounding the name in double quotes or preceding
       the character with a backslash.

       White space is ignored everywhere except within a quoted instance name.

       An empty instance is silently ignored, and in particular  ``[]''  is  the  same  as  no  instance,  while
       ``[one,,,two]'' is parsed as specifying just the two instances ``one'' and ``two''.

       As  a  special  case,  if  the  host is the single character ``@'' then this refers to a PM_CONTEXT_LOCAL
       source, see pmNewContext(3).

SECURE PMCD CONNECTIONS

       Since PCP version 3.6.11, a monitor can explicitly request  a  secure  connection  to  a  collector  host
       running  pmcd(1)  or  pmproxy(1)  using  the  PM_CTXFLAG_SECURE  context flag.  If the PCP Collector host
       supports this feature - refer to the pmcd.feature.secure metric for confirmation  of  this  -  a  TLS/SSL
       (Transport  Layer  Security  or Secure Sockets Layer) connection can be established which uses public key
       cryptography and related techniques.  These features aim to prevent eavesdropping and data tampering from
       a  malicious  third party, as well as providing server-side authentication (confident identification of a
       server by a client) which can be used to guard against man-in-the-middle attacks.

       A secure pmcd connection requires use of certificate-based authentication.  The security features offered
       by  pmcd  and  pmproxy are implemented using the Network Security Services (NSS) APIs and utilities.  The
       NSS certutil tool can be used to create certificates suitable for establishing trust between PCP  monitor
       and collector hosts.

       A  complete description is beyond the scope of this document, refer to the PCP ENVIRONMENT, FILES and SEE
       ALSO sections for detailed information.  This includes links  to  tutorials  on  the  steps  involved  in
       setting up the available security features.

PMCD HOST SPECIFICATION

       In  the absence of an explicit host name specification, most tools will default to the local host in live
       update mode.  In PCP releases since 3.8.4 onward, this results  in  an  efficient  local  protocol  being
       selected  -  typically  a  Unix  domain  socket.   If  this  option is used (which can also be explicitly
       requested via the unix: host specification described below), it is important to note that all connections
       will  be  automatically authenticated. In other words, the credentials of the user invoking a client tool
       will automatically be made available to pmcd(1) and all of its PMDAs, on  the  users  behalf,  such  that
       results can be customized to the privilege levels of individual users.

       Names  of remote hosts running the pmcd(1) daemon can of course also be provided to request a remote host
       be used.  The most basic form of pmcd host specification is a simple host name,  possibly  including  the
       domain name if necessary.  However, this can be extended in a number of ways to further refine attributes
       of the connection made to pmcd.

       The pmcd port number and also optional pmproxy(1) hostname and its port number, can be given as  part  of
       the  host  specification, since PCP version 3.0.  These supersede (and override) the old-style PMCD_PORT,
       PMPROXY_HOST and PMPROXY_PORT environment variables.

       The following are valid hostname specifications that specify connections to pmcd on host nas1.servers.com
       with/without  a list of ports, with/without a pmproxy(1) connection through a firewall, and with IPv6 and
       IPv4 addresses as shown.

            $ pcp -h nas1.servers.com:44321,4321@firewall.servers.com:44322
            $ pcp -h nas1.servers.com:44321@firewall.servers.com:44322
            $ pcp -h nas1.servers.com:44321@firewall.servers.com
            $ pcp -h nas1.servers.com@firewall.servers.com
            $ pcp -h nas1.servers.com:44321
            $ pcp -h [fe80::2ad2:44ff:fe88:e4f1%p2p1]
            $ pcp -h 192.168.0.103

       In addition, ``connection attributes'' can also be specified.  These include username, password  (can  be
       given  interactively  and  may  depend  on  the  authentication  mechanism employed), whether to target a
       specific running container, whether to use secure (encrypted) or native (naked) protocol, and so on.  The
       previous  examples all default to native protocol, and use no authentication.  This can be altered, as in
       the following examples.

            $ pcp -h pcps://app2.servers.com?container=cae8e6edc0d5
            $ pcp -h pcps://nas1.servers.com:44321?username=tanya&method=gssapi
            $ pcp -h pcps://nas2.servers.com@firewalls.r.us?method=plain
            $ pcp -h pcp://nas3.servers.com
            $ pcp -h 192.168.0.103?container=cae8e6edc0d5,method=digest-md5
            $ pcp -h unix:
            $ pcp -h local:

       The choice of authentication method, and other resulting parameters like username,  optionally  password,
       etc,  depends  on the SASL2 configuration used by each (remote) pmcd.  Tutorials are available specifying
       various aspects of configuring the authentication module(s) used, these  fine  details  are  outside  the
       scope of this document.

       In  all  situations,  host  names can be used interchangeably with IPv4 or IPv6 addressing (directly), as
       shown above.  In the case of an IPv6 address, the full address must be enclosed by  square  brackets  and
       the scope (interface) must also be specified.

       The  final  local:  example above is now the default for most tools.  This connection is an automatically
       authenticated local host connection on all platforms that support Unix domain sockets.   No  password  is
       required   and  authentication  is  automatic.   This  is  also  the  most  efficient  (lowest  overhead)
       communication channel available.

       The difference between unix: and local: is that the former is a strict Unix domain  socket  specification
       (connection  fails  if  it  cannot connect that way), whereas the latter has a more forgiving fallback to
       using localhost (i.e. a regular Inet socket connection is used when Unix domain  socket  connections  are
       unavailable).

ENVIRONMENT

       In  addition to the PCP run-time environment and configuration variables described in the PCP ENVIRONMENT
       section below, the following environment variables apply to all installations.

       PCP_CONSOLE
              When set, this changes the default console from /dev/tty (on Unix) or CON: (on Windows) to be  the
              specified  console.  The special value of none can be used to indicate no console is available for
              use.  This is used in places where console-based tools need to interact  with  the  user,  and  in
              particular is used when authentication is being performed.

       PCP_DEBUG
              When  set,  this  variable  provides  an  alternate  way  to  initialize the value used to control
              diagnostic and debug output (the default value is 0 to  suppress  this  output).   The  value  for
              $PCP_DEBUG should be a decimal integer, see pmdbg(1) for a description of the supported values.

       PCP_DERIVED_CONFIG
              When  set, this variable defines a colon separated list of files and/or directories (the syntax is
              the same as for the $PATH variable for sh(1)).  The components are expanded into a list  of  files
              as  follows: if a component of $PCP_DERIVED_CONFIG is a file, then that file is added to the list,
              else if a component is a directory then recursive descent is used to  enumerate  all  files  below
              that directory and these are added to the list.

              Each  file  in  the resulting list is assumed to contain definitions of derived metrics as per the
              syntax described in pmLoadDerivedConfig(3), and these are loaded in order.

              Derived metrics may be used to extend the available  metrics  with  new  (derived)  metrics  using
              simple arithmetic expressions.

              If  PCP_DERIVED_CONFIG  is set, the derived metric definitions are processed automatically as each
              new source of performance metrics is established (i.e. each time a pmNewContext(3) is  called)  or
              when requests are made against the PMNS.

              Any component in the $PCP_DERIVED_CONFIG list or the expanded list of files that is not a file, or
              is not a directory or is not accessible (due to permissions  or  a  bad  symbolic  link)  will  be
              silently ignored.

       PCP_SECURE_SOCKETS
              When  set,  this  variable  forces  any  monitor  tool  connections  to  be  established using the
              certificate-based secure sockets feature.  If the connections cannot be established securely, they
              will fail.

       PCP_SECURE_DB_METHOD
              With  secure  socket connections, the certificate and key database is stored using the sql: method
              by default.  Use PCP_SECURE_DB_METHOD to override the default, most usually setting the  value  to
              the empty string (for the older database methods).

       PCP_STDERR
              Many  PCP  tools  support  the environment variable PCP_STDERR, which can be used to control where
              error messages are sent.  When unset, the default behavior is that ``usage'' messages  and  option
              parsing  errors  are  reported on standard error, other messages after initial startup are sent to
              the default destination for the tool, i.e. standard error for ASCII tools, or  a  dialog  for  GUI
              tools.

              If PCP_STDERR is set to the literal value DISPLAY then all messages will be displayed in a dialog.
              This is used for any tools launched from the a Desktop environment.

              If PCP_STDERR is set to any other value, the value is assumed to be a filename, and  all  messages
              will be written there.

       PMCD_CONNECT_TIMEOUT
              When  attempting  to  connect  to  a  remote  pmcd(1) on a machine that is booting, the connection
              attempt  could  potentially  block  for  a  long  time  until  the  remote  machine  finishes  its
              initialization.   Most PCP applications and some of the PCP library routines will abort and return
              an error if the connection has not been established after some  specified  interval  has  elapsed.
              The  default  interval  is 5 seconds.  This may be modified by setting PMCD_CONNECT_TIMEOUT in the
              environment to a real number of seconds for the desired timeout.  This is  most  useful  in  cases
              where the remote host is at the end of a slow network, requiring longer latencies to establish the
              connection correctly.

       PMCD_RECONNECT_TIMEOUT
              When a monitor or client application loses a connection to a pmcd(1), the connection  may  be  re-
              established  by  calling a service routine in the PCP library.  However, attempts to reconnect are
              controlled by a back-off strategy to avoid flooding the network with  reconnection  requests.   By
              default,  the  back-off  delays  are  5,  10,  20,  40 and 80 seconds for consecutive reconnection
              requests from a client (the last delay will be repeated for any further attempts after the fifth).
              Setting  the  environment  variable  PMCD_RECONNECT_TIMEOUT  to a comma separated list of positive
              integers will re-define the back-off delays, e.g. setting PMCD_RECONNECT_TIMEOUT to  ``1,2''  will
              back-off for 1 second, then attempt another connection request every 2 seconds thereafter.

       PMCD_REQUEST_TIMEOUT
              For monitor or client applications connected to pmcd(1), there is a possibility of the application
              "hanging" on a request for performance metrics or metadata or help text.  These delays may  become
              severe  if  the  system  running  pmcd crashes, or the network connection is lost.  By setting the
              environment variable PMCD_REQUEST_TIMEOUT to a number of seconds, requests to  pmcd  will  timeout
              after  this  number  of  seconds.   The default behavior is to be willing to wait 10 seconds for a
              response from every pmcd for all applications.

       PMCD_WAIT_TIMEOUT
              When pmcd(1) is started from $PCP_RC_DIR/pcp then the primary  instance  of  pmlogger(1)  will  be
              started  if  the  configuration  flag  pmlogger  is  chkconfig(8)  enabled and pmcd is running and
              accepting connections.

              The check on pmcd's readiness will wait up to PMCD_WAIT_TIMEOUT  seconds.   If  pmcd  has  a  long
              startup  time  (such  as  on  a very large system), then PMCD_WAIT_TIMEOUT can be set to provide a
              maximum wait longer than the default 60 seconds.

       PMNS_DEFAULT
              If set, then interpreted as  the  full  pathname  to  be  used  as  the  default  local  PMNS  for
              pmLoadNameSpace(3).   Otherwise,  the  default local PMNS is located at $PCP_VAR_DIR/pcp/pmns/root
              for base PCP installations.

       PCP_COUNTER_WRAP
              Many of the performance metrics exported from PCP agents have the  semantics  of  counter  meaning
              they  are  expected  to be monotonically increasing.  Under some circumstances, one value of these
              metrics may smaller than the previously fetched value.  This can happen when a counter  of  finite
              precision  overflows,  or when the PCP agent has been reset or restarted, or when the PCP agent is
              exporting values from some  underlying  instrumentation  that  is  subject  to  some  asynchronous
              discontinuity.

              The  environment  variable  PCP_COUNTER_WRAP  may  be  set  to  indicate  that all such cases of a
              decreasing ``counter'' should be treated as a counter overflow, and hence the values  are  assumed
              to  have wrapped once in the interval between consecutive samples.  This ``wrapping'' behavior was
              the default in earlier PCP versions, but by default has been disabled in PCP release from  version
              1.3 on.

       PMDA_PATH
              The  PMDA_PATH  environment  variable  may  be  used to modify the search path used by pmcd(1) and
              pmNewContext(3) (for PM_CONTEXT_LOCAL contexts) when searching for a  daemon  or  DSO  PMDA.   The
              syntax follows that for PATH in sh(1), i.e. a colon separated list of directories, and the default
              search path is ``/var/pcp/lib:/usr/pcp/lib'', (or ``/var/lib/pcp/lib'' on Linux, depending on  the
              value of the $PCP_VAR_DIR environment variable).

       PMCD_PORT
              The TPC/IP port(s) used by pmcd(1) to create the socket for incoming connections and requests, was
              historically 4321 and more recently the officially registered port 44321; in the current  release,
              both  port  numbers are used by default as a transitional arrangement.  This may be over-ridden by
              setting PMCD_PORT to a different port number, or a comma-separated list of  port  numbers.   If  a
              non-default  port  is  used  when pmcd is started, then every monitoring application connecting to
              that pmcd must also have PMCD_PORT set in their environment before attempting a connection.

       The following environment variables are relevant to installations in which pmlogger(1), the  PCP  archive
       logger, is used.

       PMLOGGER_PORT
              The  environment  variable PMLOGGER_PORT may be used to change the base TCP/IP port number used by
              pmlogger(1) to create the socket to which pmlc(1) instances will try  and  connect.   The  default
              base  port  number  is  4330.   When  used,  PMLOGGER_PORT should be set in the environment before
              pmlogger is executed.

       PMLOGGER_REQUEST_TIMEOUT
              When pmlc(1) connects to pmlogger(1), there is a remote possibility of pmlc "hanging" on a request
              for  information  as  a  consequence  of  a  failure  of  the network or pmlogger.  By setting the
              environment variable PMLOGGER_REQUEST_TIMEOUT to a number of seconds, requests  to  pmlogger  will
              timeout after this number of seconds.  The default behavior is to be willing to wait forever for a
              response from each request to a pmlogger.  When used, PMLOGGER_REQUEST_TIMEOUT should  be  set  in
              the environment before pmlc is executed.

       If  you  have  the  PCP  product  installed, then the following environment variables are relevant to the
       Performance Metrics Domain Agents (PMDAs).

       PMDA_LOCAL_PROC
              Use this variable has been deprecated and it is now ignored.  If the ``proc'' PMDA  is  configured
              as a DSO for use with pmcd(1) on the local host then all of the ``proc'' metrics will be available
              to applications using a PM_CONTEXT_LOCAL context.

              The previous behaviour was that if this variable was set, then a context established with the type
              of  PM_CONTEXT_LOCAL  will  have access to the ``proc'' PMDA to retrieve performance metrics about
              individual processes.

       PMDA_LOCAL_SAMPLE
              Use this variable has been deprecated and it is now ignored.  If the ``sample'' PMDA is configured
              as  a  DSO  for  use  with  pmcd(1)  on  the local host then all of the ``sample'' metrics will be
              available to applications using a PM_CONTEXT_LOCAL context.

              The previous behaviour was that if this variable was set, then a context established with the type
              of  PM_CONTEXT_LOCAL  will  have  access  to  the  ``sample''  PMDA if this optional PMDA has been
              installed locally.

       PMIECONF_PATH
              If set, pmieconf(1) will form its pmieconf(5) specification (set of parameterized  pmie(1)  rules)
              using  all  valid  pmieconf  files  found  below each subdirectory in this colon-separated list of
              subdirectories.  If not set, the default is $PCP_VAR_DIR/config/pmieconf.

FILES

       /etc/pcp.conf
                 Configuration file for the PCP runtime environment, see pcp.conf(5).
       /etc/pki/nssdb
                 Optionally contains a Network Security Services database with  a  "PCP  Collector"  certificate
                 providing trusted identification for the collector host.
       $HOME/.pcp
                 User-specific  directories  containing  configuration  files  for  customisation of the various
                 monitor tools, such as pmchart(1).
       $HOME/.pki/nssdb
                 A shared Network Security Services (NSS) database directory  containing  per-user  certificates
                 identifying  known  valid remote pmcd collector hosts.  The NSS certutil tool is one of several
                 that can be used to maintain this database.
       $PCP_RC_DIR/pcp
                 Script for starting and stopping pmcd(1).
       $PCP_PMCDCONF_PATH
                 Control file for pmcd(1).
       $PCP_PMCDOPTIONS_PATH
                 Command line options passed to pmcd(1) when  it  is  started  from  $PCP_RC_DIR/pcp.   All  the
                 command  line  option  lines  should start with a hyphen as the first character.  This file can
                 also contain environment variable settings of the form "VARIABLE=value".
       $PCP_BINADM_DIR
                 Location of PCP utilities for collecting and maintaining PCP archives,  PMDA  help  text,  PMNS
                 files etc.
       $PCP_PMDAS_DIR
                 Parent directory of the installation directory for Dynamic Shared Object (DSO) PMDAs.
       $PCP_RUN_DIR/pmcd.pid
                 If pmcd is running, this file contains an ascii decimal representation of its process ID.
       $PCP_LOG_DIR/pmcd
                 Default  location  of  log  files  for  pmcd(1), current directory for running PMDAs.  Archives
                 generated by pmlogger(1) are generally below $PCP_LOG_DIR/pmlogger.
       $PCP_LOG_DIR/pmcd/pmcd.log
                 Diagnostic and status log for the current running pmcd(1) process.  The  first  place  to  look
                 when there are problems associated with pmcd.
       $PCP_LOG_DIR/pmcd/pmcd.log.prev
                 Diagnostic and status log for the previous pmcd(1) instance.
       $PCP_LOG_DIR/NOTICES
                 Log of pmcd(1) and PMDA starts, stops, additions and removals.
       $PCP_VAR_DIR/config
                 Contains directories of configuration files for several PCP tools.
       $PCP_SYSCONF_DIR/pmcd/rc.local
                 Local script for controlling PCP boot, shutdown and restart actions.
       $PCP_VAR_DIR/pmns
                 Directory containing the set of PMNS files for all installed PMDAs.
       $PCP_VAR_DIR/pmns/root
                 The  ASCII  pmns(5) exported by pmcd(1) by default.  This PMNS is be the super set of all other
                 PMNS files installed in $PCP_VAR_DIR/pmns.
       In addition, if the PCP product is installed the following files and directories are relevant.
       $PCP_LOG_DIR/NOTICES
              In addition to the pmcd(1) and PMDA activity, may be used to log alarms and notices  from  pmie(1)
              via pmpost(1).
       $PCP_PMLOGGERCONTROL_PATH
              Control   file   for  pmlogger(1)  instances  launched  from  $PCP_RC_DIR/pcp  and/or  managed  by
              pmlogger_check(1) and pmlogger_daily(1) as part of a production PCP archive collection setup.

PCP ENVIRONMENT

       Environment variables with the prefix PCP_ are used to parameterize the file and directory names used  by
       PCP.   On  each  installation, the file /etc/pcp.conf contains the local values for these variables.  The
       $PCP_CONF variable may be used to specify an alternative configuration file, as described in pcp.conf(5).

SEE ALSO

       pmcd(1), pmie(1), pmie_daily(1), pminfo(1), pmlc(1), pmlogger(1), pmlogger_daily(1), pmstat(1), pmval(1),
       pcp(1), pcp.conf(5), pcp.env(5), pmns(5) and chkconfig(8).

       If the PCP GUI package is installed, then the following entries are also relevant:
       pmchart(1), pmtime(1), and pmdumptext(1).

       If the secure sockets extensions have been enabled, then the following references are also relevant:
       http://www.pcp.io/documentation.html
       http://www.mozilla.org/projects/security/pki/nss/#documentation
       http://www.mozilla.org/projects/security/pki/nss/tools/certutil.html

       Also  refer  to  the books Performance Co-Pilot User's and Administrator's Guide and Performance Co-Pilot
       Programmer's Guide which can be found at http://www.pcp.io/