Provided by: aegis_4.24.3-3_amd64 bug

NAME

        aegis clEan - clean files from development directory

SYNOPSIS

        aegis -CLEan [ option...  ]
        aegis -CLEan -Help
        aegis -VERSion

DESCRIPTION

        The  aegis  -CLEan  command  is  used  to  remove  all  files  which  are not change source files from a
        development directory.  This can be used to obtain a “clean” development directory before a final build,
        to ensure that a change is ready to end development.  A new build will be required.

        This command is only allowed in the “being developed” state, and only the change's developer  may  issue
        it.  It may not be applied to branches.

        All symbolic links will be removed from the development directory, even if remove_symlinks_after_build =
        false  in the project config file.  The symbolic links will be re-installed, if create_symlinks_before_‐
        build = true.  This is to ensure that the symlinks are accurate, and that unnecessary ones are removed.

        All special device files, pipes and sockets will be removed.  These files cannot be source files, and it
        is expected that the following build will restore them.

        All derived files created by previous builds of the change will be removed.  It  is  expected  that  the
        following  build  will  recreate  them.   Any  temporary  files  you may have created in the development
        directory will also be removed.

        The develop_begin_command in the project configuration file (see aepconf(5) for more  information)  will
        be   run,   if   there   is   one.   The  change_file_command  will  be  run,  if  there  is  one.   The
        project_file_command will be run, if there is one.

        You will be warned if any of the files are out-of-date and need to be merged.  You will be warned if any
        files need to be differenced.

SYMBOLIC LINKS

        Many dependency maintenance tools, and indeed some compilers, have little or no support for include file
        search paths, and thus for the concept of the two-level directory  hierarchy  employed  by  Aegis.   (It
        becomes  multi-level  when  Aegis'  branching  functionality is used.)  To allow these tools to be used,
        Aegis provides the ability to maintain a set of symbolic links between the development  directory  of  a
        change  and  the baseline of a project, so it appears to these tools that all of the project's files are
        present in the development directory.

   Project Configuration
        The development_directory_style field of the project configuration file controls the appearance  of  the
        development directory.  See aepconf(5) for more information.

        By using a setting such as
                development_directory_style =
                {
                    source_file_symlink = true;
                    during_build_only = true;
                };
        the  user never sees the symbolic links, because they are added purely for the benefit of the dependency
        maintenance tool during the execution of the aeb(1) command.

        By using a setting such as
                development_directory_style =
                {
                    source_file_symlink = true;
                };
        (the other will default to false) the symbolic links will be created at develop begin time (see  aedb(1)
        for  more  information) and also maintained by each aeb(1) invocation.  Note that the symbolic links are
        only maintained at these times, so project integrations during the course of editing change sourec files
        may leave the symbolic links in an inconsistent state until the next build.

        When files are copied from the baseline into a change, using the  aecp(1)  command,  the  symbolic  link
        pointing into the baseline, if any, will be removed before the file is copied.

        Note:  Using this functionality in either form has implications for how the rules file of the dependency
        maintenance tool is written.  Rules must remove their targets before creating them (usually with  an  rm
        -f  command)  if  you  use  any of the link sub-fields (both hard links and symbolic links).  This is to
        avoid attempting to write the result on the symbolic link, which will point at a read-only file  in  the
        project  baseline.   This  is  similar  to the same requirement for using the link_integration_directory
        field of the project configuration file.

   User Configuration
        There is a symbolic_link_preference field in the  user  configuration  file  (see  aeuconf(5)  for  more
        information).  This controls whether aeb(1) will verify the symbolic links before the build (default) or
        whether  it  will  assume  they are up-to-date.  (This field is only relevant if development_directory_‐
        _style.source_file_symlink is true.)

        For medium-to-large projects, verifying the symbolic links  can  take  as  long  as  the  build  itself.
        Assuming  the  symbolic  links  are up-to-date can be a large time-saving for these projects.  It may be
        advisable to review your choice of DMT in such a situation.

        The aedb(1) command does not consult this preference.  Thus, in most situations, the symbolic links will
        be up-to-date when the build is performed.  The only Aegis function which may  result  in  the  symbolic
        links  becoming  out-of-date  is  the  integration  of another change, as this may alter the presence or
        absence of files in the baseline.  In this situation, the default aeb(1) action is to  ignore  the  user
        preference and the verify symbolic links.

        There  are  two  command  line  options which modify aeb(1) behavior further: the -Verify-Symbolic-Links
        option says to verify the symbolic links; and the  -Assume-Symbolic-Links  option  says  to  assume  the
        symbolic links are up-to-date.  In each case the option over-rides the default and the user preference.

        It is possible to obtain behaviour similar to Tom Lord'a Arch by using a setting such as:
                development_directory_style =
                {
                    source_file_link = true;
                    source_file_symlink = true;
                };

        It is possible to obtain behaviour similar to CVS by using a setting such as:
                development_directory_style =
                {
                    source_file_copy = true;
                };
        There  are  many  more  possible configurations of the development_directory_style, usually with helpful
        build side-effects.  See aepconf(1) and the Depenedency Maintenance Tool chapter of the User  Guide  for
        more information.

        The  symbolic link command line options and preferences apply equally to hard links and file copies (the
        names have historical origins).

   Notification
        The notification commands that would be run by  the  aecp(1),  aedb(1),  aenf(1),  aent(1)  and  aerm(1)
        commands  are  run,  as  appropriate.  The project_file_command is also run, if set.  See aepconf(5) for
        more information.

OPTIONS

        The following options are understood:

        -Change number
                This option may be used to specify a particular change within a project.   See  aegis(1)  for  a
                complete description of this option.

        -Help
                This option may be used to obtain more information about how to use the aegis program.

        -List
                This option may be used to obtain a list of suitable subjects for this command.  The list may be
                more general than expected.

        -Not_Logging
                This  option  may be used to disable the automatic logging of output and errors to a file.  This
                is often useful when several aegis commands are combined in a shell script.

        -TOuch  This option may be used to request that each change source file  have  its  last-modified  time-
                stamp  be updated to the current time.  This is the default.  Derived files and other non-source
                file are left alone.

        -No_TOuch
                This option may be used to request that the last-modified time-stamp of each source file be left
                unmodified.

        -MINIMum
                This  option  may  be  used  to  request  a  minimum   set   of   symbolic   links,   when   the
                create_symlinks_to_baseline  functions  are  being used.  This is useful if you want to simulate
                something like aeib -minimum in the development directory.  This option  is  not  meaningful  if
                symbolic links are not being used.

                This  option also says not to remove normal files which occlude project source files.  This is a
                common technique used to temporarily over-ride project  source  files.   The  “aecp  -read-only”
                command would have been more appropriate.

        -Project name
                This  option  may  be  used  to  select  the  project  of  interest.  When no -Project option is
                specified, the AEGIS_PROJECT environment variable is consulted.  If that  does  not  exist,  the
                user's  $HOME/.aegisrc  file  is  examined  for a default project field (see aeuconf(5) for more
                information).  If that does not exist, when the user is only working on changes within a  single
                project, the project name defaults to that project.  Otherwise, it is an error.

        -Verbose
                This  option  may be used to cause aegis to produce more output.  By default aegis only produces
                output on errors.  When used with the -List option this option  causes  column  headings  to  be
                added.

        -Wait   This  option  may  be used to require Aegis commands to wait for access locks, if they cannot be
                obtained immediately.  Defaults  to  the  user's  lock_wait_preference  if  not  specified,  see
                aeuconf(5) for more information.

        -No_Wait
                This  option  may be used to require Aegis commands to emit a fatal error if access locks cannot
                be obtained immediately.  Defaults to the user's  lock_wait_preference  if  not  specified,  see
                aeuconf(5) for more information.

        See also aegis(1) for options common to all aegis commands.

        All options may be abbreviated; the abbreviation is documented as the upper case letters, all lower case
        letters and underscores (_) are optional.  You must use consecutive sequences of optional letters.

        All  options  are  case  insensitive,  you may type them in upper case or lower case or a combination of
        both, case is not important.

        For example: the arguments "-project, "-PROJ" and "-p" are all interpreted to mean the -Project  option.
        The argument "-prj" will not be understood, because consecutive optional characters were not supplied.

        Options  and  other  command  line  arguments  may  be  mixed arbitrarily on the command line, after the
        function selectors.

        The GNU long option names are understood.  Since all  option  names  for  aegis  are  long,  this  means
        ignoring the extra leading '-'.  The "--option=value" convention is also understood.

EXIT STATUS

        The  aegis  command  will exit with a status of 1 on any error.  The aegis command will only exit with a
        status of 0 if there are no errors.

ENVIRONMENT VARIABLES

        See aegis(1) for a list of environment variables which may affect this command.  See aepconf(5) for  the
        project  configuration  file's  project_specific  field  for  how  to  set environment variables for all
        commands executed by Aegis.

COPYRIGHT

        aegis version 4.24.3.D001
        Copyright (C) 1991, 1992, 1993, 1994, 1995, 1996, 1997, 1998, 1999, 2000, 2001, 2002, 2003, 2004,  2005,
        2006, 2007, 2008, 2009, 2010 Peter Miller

        The  aegis  program  comes  with  ABSOLUTELY  NO  WARRANTY; for details use the 'aegis -VERSion License'
        command.  This is free software and you are welcome to redistribute it  under  certain  conditions;  for
        details use the 'aegis -VERSion License' command.

AUTHOR

        Peter Miller   E-Mail:   millerp@canb.auug.org.au
        /\/\*             WWW:   http://www.canb.auug.org.au/~millerp/

Reference Manual                                      Aegis                                      aegis -CLEan(1)