        aegis new change undo - remove a new change from a project

SYNOPSIS

        aegis -New_Change_Undo [ option...  ]
        aegis -New_Change_Undo -List [ option...  ]
        aegis -New_Change_Undo -Help

DESCRIPTION

        The aegis -New_Change_Undo command is used to remove a new change from a project.

        It  wasn't  called  'aegis -Remove_Change' in order to emphasize that fact the the change must be in the
        awaiting development state.  In practice it is possible, with a combination of commands, to  remove  any
        change which has not reached the completed
                    │
                    │new
                    ┬change
        │ new  ┌────┴────┐
        ┴change│awaiting │
--

OPTIONS

        The following options are understood:

        -Change number
                This  option  may  be  used to specify a particular change within a project.  See aegis(1) for a
                complete description of this option.

        -Help
                This option may be used to obtain more information about how to use the aegis program.

        -List
                This option may be used to obtain a list of suitable subjects for this command.  The list may be
                more general than expected.

        -Project name
                This option may be used to  select  the  project  of  interest.   When  no  -Project  option  is
                specified,  the  AEGIS_PROJECT  environment  variable is consulted.  If that does not exist, the
                user's $HOME/.aegisrc file is examined for a default project  field  (see  aeuconf(5)  for  more
                information).   If that does not exist, when the user is only working on changes within a single
                project, the project name defaults to that project.  Otherwise, it is an error.

        -TERse
                This option may be used to cause listings to produce the bare minimum  of  information.   It  is
                usually useful for shell scripts.

        -Verbose
                This  option  may be used to cause aegis to produce more output.  By default aegis only produces
                output on errors.  When used with the -List option this option  causes  column  headings  to  be
                added.

        -Wait   This  option  may  be used to require Aegis commands to wait for access locks, if they cannot be
                obtained immediately.  Defaults  to  the  user's  lock_wait_preference  if  not  specified,  see
                aeuconf(5) for more information.

        -No_Wait
                This  option  may be used to require Aegis commands to emit a fatal error if access locks cannot
                be obtained immediately.  Defaults to the user's  lock_wait_preference  if  not  specified,  see
                aeuconf(5) for more information.

        See also aegis(1) for options common to all aegis commands.

        All options may be abbreviated; the abbreviation is documented as the upper case letters, all lower case
        letters and underscores (_) are optional.  You must use consecutive sequences of optional letters.

        All  options  are  case  insensitive,  you may type them in upper case or lower case or a combination of
        both, case is not important.

        For example: the arguments "-project, "-PROJ" and "-p" are all interpreted to mean the -Project  option.
        The argument "-prj" will not be understood, because consecutive optional characters were not supplied.

        Options  and  other  command  line  arguments  may  be  mixed arbitrarily on the command line, after the
        function selectors.

        The GNU long option names are understood.  Since all  option  names  for  aegis  are  long,  this  means
        ignoring the extra leading '-'.  The "--option=value" convention is also understood.

RECOMMENDED ALIAS

        The recommended alias for this command is
        csh%    alias aencu 'aegis -ncu \!* -v'
        sh$     aencu(){aegis -ncu "$@" -v}

ERRORS

        It is an error if the change is not in the awaiting development state.
        It  is  an  error if any use other than a project administrator or the creator of the change attempts to
        run this command.

EXIT STATUS

        The aegis command will exit with a status of 1 on any error.  The aegis command will only  exit  with  a
        status of 0 if there are no errors.

ENVIRONMENT VARIABLES

        See  aegis(1) for a list of environment variables which may affect this command.  See aepconf(5) for the
        project configuration file's project_specific field  for  how  to  set  environment  variables  for  all
        commands executed by Aegis.

SEE ALSO

        aenc(1) add a new change to a project

        aeuconf(5)
                user configuration file format

COPYRIGHT

        aegis version 4.24.3.D001
        Copyright  (C) 1991, 1992, 1993, 1994, 1995, 1996, 1997, 1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005,
        2006, 2007, 2008, 2009, 2010 Peter Miller

        The aegis program comes with ABSOLUTELY NO WARRANTY;  for  details  use  the  'aegis  -VERSion  License'
        command.   This  is  free  software and you are welcome to redistribute it under certain conditions; for
        details use the 'aegis -VERSion License' command.

AUTHOR

        Peter Miller   E-Mail:   millerp@canb.auug.org.au
        /\/\*             WWW:   http://www.canb.auug.org.au/~millerp/

Reference Manual                                      Aegis                            aegis -New_Change_Undo(1)