Provided by: pcp_3.10.8build1_amd64 bug

NAME

       pcp-verify - verify aspects of a PCP installation

SYNOPSIS

       pcp verify [-c/--containers] [-s/--secure] [-v/--verbose]

DESCRIPTION

       pcp-verify  inspects  various  aspects  of  a  PCP  collector  installation  and reports on whether it is
       configured correctly for certain modes of operation.

       By default, pcp-verify checks that PMCD is running and no agents are in a failed state.  These checks can
       be extended and refined using the command line.

OPTIONS

       Additional options are available for changing the verification performed by pcp-verify.

       -c/--containers verifies the collector installation for monitoring containers.

       -s/--secure verifies that the required components for encrypted communication are in place.

       -v/--verbose increase the verbosity, and report on each check as it is  made.   In  the  absence  of  any
       issues found, pcp-verify operates silently.

DIAGNOSTICS

       pcp-verify  will exit with a non-zero status if it finds anything worth reporting, otherwise it is silent
       and returns zero.

SEE ALSO

       pcp(1) and PCPIntro(1).

Performance Co-Pilot                                   PCP                                         PCP-VERIFY(1)