Provided by: manpages_4.04-2_all bug

NAME

     mdoc.samples — tutorial sampler for writing BSD manuals with -mdoc

SYNOPSIS

     man mdoc.samples

DESCRIPTION

     A tutorial sampler for writing BSD manual pages with the -mdoc macro package, a content-based and
     domain-based formatting package for troff(1).  Its predecessor, the -man(7) package, addressed page layout
     leaving the manipulation of fonts and other typesetting details to the individual author.  In -mdoc, page
     layout macros make up the page structure domain which consists of macros for titles, section headers,
     displays and lists.  Essentially items which affect the physical position of text on a formatted page.  In
     addition to the page structure domain, there are two more domains, the manual domain and the general text
     domain.  The general text domain is defined as macros which perform tasks such as quoting or emphasizing
     pieces of text.  The manual domain is defined as macros that are a subset of the day to day informal
     language used to describe commands, routines and related BSD files.  Macros in the manual domain handle
     command names, command-line arguments and options, function names, function parameters, pathnames,
     variables, cross references to other manual pages, and so on.  These domain items have value for both the
     author and the future user of the manual page.  It is hoped the consistency gained across the manual set
     will provide easier translation to future documentation tools.

     Throughout the UNIX manual pages, a manual entry is simply referred to as a man page, regardless of actual
     length and without sexist intention.

GETTING STARTED

     Since a tutorial document is normally read when a person desires to use the material immediately, the
     assumption has been made that the user of this document may be impatient.  The material presented in the
     remained of this document is outlined as follows:

           1.   TROFF IDIOSYNCRASIES
                      Macro Usage.
                      Passing Space Characters in an Argument.
                      Trailing Blank Space Characters (a warning).
                      Escaping Special Characters.

           2.   THE ANATOMY OF A MAN PAGE
                      A manual page template.

           3.   TITLE MACROS.

           4.   INTRODUCTION OF MANUAL AND GENERAL TEXT DOMAINS.
                      What's in a name....
                      General Syntax.

           5.   MANUAL DOMAIN
                      Addresses.
                      Author name.
                      Arguments.
                      Configuration Declarations (section four only).
                      Command Modifier.
                      Defined Variables.
                      Errno's (Section two only).
                      Environment Variables.
                      Function Argument.
                      Function Declaration.
                      Flags.
                      Functions (library routines).
                      Function Types.
                      Interactive Commands.
                      Names.
                      Options.
                      Pathnames.
                      Variables.
                      Cross References.

           6.   GENERAL TEXT DOMAIN
                      AT&T Macro.
                      BSD Macro.
                      FreeBSD Macro.
                      UNIX Macro.
                      Enclosure/Quoting Macros
                                  Angle Bracket Quote/Enclosure.
                                  Bracket Quotes/Enclosure.
                                  Double Quote macro/Enclosure.
                                  Parenthesis Quote/Enclosure.
                                  Single Quotes/Enclosure.
                                  Prefix Macro.
                      No-Op or Normal Text Macro.
                      No Space Macro.
                      Section Cross References.
                      References and Citations.
                      Return Values (sections two and three only)
                      Trade Names (Acronyms and Type Names).
                      Extended  Arguments.

           7.   PAGE STRUCTURE DOMAIN
                      Section Headers.
                      Paragraphs and Line Spacing.
                      Keeps.
                      Displays.
                      Font Modes (Emphasis, Literal, and Symbolic).
                      Lists and Columns.

           8.   PREDEFINED STRINGS

           9.   DIAGNOSTICS

           10.  FORMATTING WITH GROFF, TROFF AND NROFF

           11.  BUGS

TROFF IDIOSYNCRASIES

     The -mdoc package attempts to simplify the process of writing a man page.  Theoretically, one should not
     have to learn the dirty details of troff(1) to use -mdoc; however, there are a few limitations which are
     unavoidable and best gotten out of the way.  And, too, be forewarned, this package is not fast.

   Macro Usage
     As in troff(1), a macro is called by placing a ‘.’ (dot character) at the beginning of a line followed by
     the two character name for the macro.  Arguments may follow the macro separated by spaces.  It is the dot
     character at the beginning of the line which causes troff(1) to interpret the next two characters as a
     macro name.  To place a ‘.’ (dot character) at the beginning of a line in some context other than a macro
     invocation, precede the ‘.’ (dot) with the ‘\&’ escape sequence.  The ‘\&’ translates literally to a zero
     width space, and is never displayed in the output.

     In general, troff(1) macros accept up to nine arguments, any extra arguments are ignored.  Most macros in
     -mdoc accept nine arguments and, in limited cases, arguments may be continued or extended on the next line
     (See Extensions).  A few macros handle quoted arguments (see Passing Space Characters in an Argument
     below).

     Most of the -mdoc general text domain and manual domain macros are special in that their argument lists are
     parsed for callable macro names.  This means an argument on the argument list which matches a general text
     or manual domain macro name and is determined to be callable will be executed or called when it is
     processed.  In this case, the argument, although the name of a macro, is not preceded by a ‘.’ (dot).  It
     is in this manner that many macros are nested; for example the option macro, ‘.Op’, may call the flag and
     argument macros, ‘Fl’ and ‘Ar’, to specify an optional flag with an argument:

           [-s bytes]         is produced by .Op Fl s Ar bytes

     To prevent a two character string from being interpreted as a macro name, precede the string with the
     escape sequence ‘\&’:

           [Fl s Ar bytes]    is produced by .Op \&Fl s \&Ar bytes

     Here the strings ‘Fl’ and ‘Ar’ are not interpreted as macros.  Macros whose argument lists are parsed for
     callable arguments are referred to as parsed and macros which may be called from an argument list are
     referred to as callable throughout this document and in the companion quick reference manual mdoc(7).  This
     is a technical faux pas as almost all of the macros in -mdoc are parsed, but as it was cumbersome to
     constantly refer to macros as being callable and being able to call other macros, the term parsed has been
     used.

   Passing Space Characters in an Argument
     Sometimes it is desirable to give as one argument a string containing one or more blank space characters.
     This may be necessary to defeat the nine argument limit or to specify arguments to macros which expect
     particular arrangement of items in the argument list.  For example, the function macro ‘.Fn’ expects the
     first argument to be the name of a function and any remaining arguments to be function parameters.  As ANSI
     C stipulates the declaration of function parameters in the parenthesized parameter list, each parameter is
     guaranteed to be at minimum a two word string.  For example, int foo.

     There are two possible ways to pass an argument which contains an embedded space.  Implementation note:
     Unfortunately, the most convenient way of passing spaces in between quotes by reassigning individual
     arguments before parsing was fairly expensive speed wise and space wise to implement in all the macros for
     AT&T troff.  It is not expensive for groff but for the sake of portability, has been limited to the
     following macros which need it the most:

           Cd    Configuration declaration (section 4 SYNOPSIS)
           Bl    Begin list (for the width specifier).
           Em    Emphasized text.
           Fn    Functions (sections two and four).
           It    List items.
           Li    Literal text.
           Sy    Symbolic text.
           %B    Book titles.
           %J    Journal names.
           %O    Optional notes for a reference.
           %R    Report title (in a reference).
           %T    Title of article in a book or journal.

     One way of passing a string containing blank spaces is to use the hard or unpaddable space character ‘\ ’,
     that is, a blank space preceded by the escape character ‘\’.  This method may be used with any macro but
     has the side effect of interfering with the adjustment of text over the length of a line.  Troff sees the
     hard space as if it were any other printable character and cannot split the string into blank or newline
     separated pieces as one would expect.  The method is useful for strings which are not expected to overlap a
     line boundary.  For example:

           fetch(char *str)  is created by ‘.Fn fetch char\ *str’

           fetch(char *str)  can also be created by ‘.Fn fetch "char *str"’

     If the ‘\’ or quotes were omitted, ‘.Fn’ would see three arguments and the result would be:

           fetch(char, *str)

     For an example of what happens when the parameter list overlaps a newline boundary, see the BUGS section.

   Trailing Blank Space Characters
     Troff can be confused by blank space characters at the end of a line.  It is a wise preventive measure to
     globally remove all blank spaces from <blank-space><end-of-line> character sequences.  Should the need
     arise to force a blank character at the end of a line, it may be forced with an unpaddable space and the
     ‘\&’ escape character.  For example, ‘string\ \&’.

   Escaping Special Characters
     Special characters like the newline character ‘\n’, are handled by replacing the ‘\’ with ‘\e’ (e.g.,
     ‘\en’) to preserve the backslash.

THE ANATOMY OF A MAN PAGE

     The body of a man page is easily constructed from a basic template found in the file
     /usr/share/misc/mdoc.template.  Several example man pages can also be found in /usr/share/examples/mdoc.

   A manual page template
           .\" The following requests are required for all man pages.
           .Dd Month day, year
           .Os OPERATING_SYSTEM [version/release]
           .Dt DOCUMENT_TITLE [section number] [volume]
           .Sh NAME
           .Nm name
           .Nd one line description of name
           .Sh SYNOPSIS
           .Sh DESCRIPTION
           .\" The following requests should be uncommented and
           .\" used where appropriate.  This next request is
           .\" for sections 2 and 3 function return values only.
           .\" .Sh RETURN VALUE
           .\" This next request is for sections 1, 6, 7 & 8 only
           .\" .Sh ENVIRONMENT
           .\" .Sh FILES
           .\" .Sh EXAMPLES
           .\" This next request is for sections 1, 6, 7 & 8 only
           .\"     (command return values (to shell) and
           .\"       fprintf/stderr type diagnostics)
           .\" .Sh DIAGNOSTICS
           .\" The next request is for sections 2 and 3 error
           .\" and signal handling only.
           .\" .Sh ERRORS
           .\" .Sh SEE ALSO
           .\" .Sh CONFORMING TO
           .\" .Sh HISTORY
           .\" .Sh AUTHORS
           .\" .Sh BUGS

     The first items in the template are the macros (.Dd, .Os, .Dt); the document date, the operating system the
     man page or subject source is developed or modified for, and the man page title (in uppercase) along with
     the section of the manual the page belongs in.  These macros identify the page, and are discussed below in
     TITLE MACROS.

     The remaining items in the template are section headers (.Sh); of which NAME, SYNOPSIS and DESCRIPTION are
     mandatory.  The headers are discussed in PAGE STRUCTURE DOMAIN, after presentation of MANUAL DOMAIN.
     Several content macros are used to demonstrate page layout macros; reading about content macros before page
     layout macros is recommended.

TITLE MACROS

     The title macros are the first portion of the page structure domain, but are presented first and separate
     for someone who wishes to start writing a man page yesterday.  Three header macros designate the document
     title or manual page title, the operating system, and the date of authorship.  These macros are one called
     once at the very beginning of the document and are used to construct the headers and footers only.

     .Dt DOCUMENT_TITLE section# [volume]
             The document title is the subject of the man page and must be in CAPITALS due to troff limitations.
             The section number may be 1, ..., 8, and if it is specified, the volume title may be omitted.  A
             volume title may be arbitrary or one of the following:

                   AMD    UNIX Ancestral Manual Documents
                   SMM    UNIX System Manager's Manual
                   URM    UNIX Reference Manual
                   PRM    UNIX Programmer's Manual

             The default volume labeling is URM for sections 1, 6, and 7; SMM for section 8; PRM for sections 2,
             3, 4, and 5.

     .Os operating_system release#
             The name of the operating system should be the common acronym, for example, BSD or FreeBSD or ATT.
             The release should be the standard release nomenclature for the system specified, for example, 4.3,
             4.3+Tahoe, V.3, V.4.  Unrecognized arguments are displayed as given in the page footer.  For
             instance, a typical footer might be:

                   .Os 4.3BSD

             or
                   .Os FreeBSD 2.2

             or for a locally produced set

                   .Os CS Department

             The Berkeley default, ‘.Os’ without an argument, has been defined as BSD in the site-specific file
             /usr/share/tmac/mdoc/doc-common.  It really should default to LOCAL.  Note, if the ‘.Os’ macro is
             not present, the bottom left corner of the page will be ugly.

     .Dd month day, year
             The date should be written formally:

                   January 25, 1989

INTRODUCTION OF MANUAL AND GENERAL TEXT DOMAINS

   What's in a name...
     The manual domain macro names are derived from the day to day informal language used to describe commands,
     subroutines and related files.  Slightly different variations of this language are used to describe the
     three different aspects of writing a man page.  First, there is the description of -mdoc macro request
     usage.  Second is the description of a UNIX command with -mdoc macros and third, the description of a
     command to a user in the verbal sense; that is, discussion of a command in the text of a man page.

     In the first case, troff(1) macros are themselves a type of command; the general syntax for a troff command
     is:

           .Va argument1 argument2 ... argument9

     The ‘.Va’ is a macro command or request, and anything following it is an argument to be processed.  In the
     second case, the description of a UNIX command using the content macros is a bit more involved; a typical
     SYNOPSIS command line might be displayed as:

           filter [-flag] infile outfile

     Here, filter is the command name and the bracketed string -flag is a flag argument designated as optional
     by the option brackets.  In -mdoc terms, infile and outfile are called arguments.  The macros which
     formatted the above example:

           .Nm filter
           .Op Fl flag
           .Ar infile outfile

     In the third case, discussion of commands and command syntax includes both examples above, but may add more
     detail.  The arguments infile and outfile from the example above might be referred to as operands or file
     arguments.  Some command-line argument lists are quite long:

           make  [-eiknqrstv] [-D variable] [-d flags] [-f makefile] [-I directory] [-j max_jobs]
                 [variable=value] [target ...]

     Here one might talk about the command make and qualify the argument makefile, as an argument to the flag,
     -f, or discuss the optional file operand target.  In the verbal context, such detail can prevent confusion,
     however the -mdoc package does not have a macro for an argument to a flag.  Instead the ‘Ar’ argument macro
     is used for an operand or file argument like target as well as an argument to a flag like variable.  The
     make command line was produced from:

           .Nm make
           .Op Fl eiknqrstv
           .Op Fl D Ar variable
           .Op Fl d Ar flags
           .Op Fl f Ar makefile
           .Op Fl I Ar directory
           .Op Fl j Ar max_jobs
           .Op Ar variable=value
           .Bk -words
           .Op Ar target ...
           .Ek

     The ‘.Bk’ and ‘.Ek’ macros are explained in Keeps.

   General Syntax
     The manual domain and general text domain macros share a similar syntax with a few minor deviations: ‘.Ar’,
     ‘.Fl’, ‘.Nm’, and ‘.Pa’ differ only when called without arguments; ‘.Fn’ and ‘.Xr’ impose an order on their
     argument lists and the ‘.Op’ and ‘.Fn’ macros have nesting limitations.  All content macros are capable of
     recognizing and properly handling punctuation, provided each punctuation character is separated by a
     leading space.  If a request is given:

           .Li sptr, ptr),

     The result is:

           sptr, ptr),

     The punctuation is not recognized and all is output in the literal font. If the punctuation is separated by
     a leading white space:

           .Li sptr , ptr ) ,

     The result is:

           sptr, ptr),

     The punctuation is now recognized and is output in the default font distinguishing it from the strings in
     literal font.

     To remove the special meaning from a punctuation character escape it with ‘\&’.  Troff is limited as a
     macro language, and has difficulty when presented with a string containing a member of the mathematical,
     logical or quotation set:

                 {+,-,/,*,%,<,>,<=,>=,=,==,&,`,',"}

     The problem is that troff may assume it is supposed to actually perform the operation or evaluation
     suggested by the characters.  To prevent the accidental evaluation of these characters, escape them with
     ‘\&’.  Typical syntax is shown in the first content macro displayed below, ‘.Ad’.

MANUAL DOMAIN

   Address Macro
     The address macro identifies an address construct of the form addr1[,addr2[,addr3]].

           Usage: .Ad address ... [.,:;()[]?!]
                   .Ad addr1           addr1
                   .Ad addr1 .         addr1.
                   .Ad addr1 , file2   addr1, file2
                   .Ad f1 , f2 , f3 :  f1, f2, f3:
                   .Ad addr ) ) ,      addr)),

     It is an error to call ‘.Ad’ without arguments.  ‘.Ad’ is callable by other macros and is parsed.

   Author Name
     The ‘.An’ macro is used to specify the name of the author of the item being documented, or the name of the
     author of the actual manual page.  Any remaining arguments after the name information are assumed to be
     punctuation.

           Usage: .An author_name [.,:;()[]?!]
                   .An Joe Author        Joe Author
                   .An Joe Author ,      Joe Author,
                   .An Joe Author Aq nobody@FreeBSD.ORG
                                         Joe Author <nobody@FreeBSD.ORG>
                   .An Joe Author ) ) ,  Joe Author)),

     The ‘.An’ macro is parsed and is callable.  It is an error to call ‘.An’ without any arguments.

   Argument Macro
     The ‘.Ar’ argument macro may be used whenever a command-line argument is referenced.

           Usage: .Ar argument ... [.,:;()[]?!]
                    .Ar              file ...
                    .Ar file1        file1
                    .Ar file1 .      file1.
                    .Ar file1 file2  file1 file2
                    .Ar f1 f2 f3 :   f1 f2 f3:
                    .Ar file ) ) ,   file)),

     If ‘.Ar’ is called without arguments, ‘Ar’ is assumed.  The ‘.Ar’ macro is parsed and is callable.

   Configuration Declaration (section four only)
     The ‘.Cd’ macro is used to demonstrate a config(8) declaration for a device interface in a section four
     manual.  This macro accepts quoted arguments (double quotes only).

           device le0 at scode?  produced by: ‘.Cd device le0 at scode?’.

   Command Modifier
     The command modifier is identical to the ‘.Fl’ (flag) command with the exception the ‘.Cm’ macro does not
     assert a dash in front of every argument.  Traditionally flags are marked by the preceding dash, some
     commands or subsets of commands do not use them.  Command modifiers may also be specified in conjunction
     with interactive commands such as editor commands.  See Flags.

   Defined Variables
     A variable which is defined in an include file is specified by the macro ‘.Dv’.

           Usage: .Dv defined_variable ... [.,:;()[]?!]
                   .Dv MAXHOSTNAMELEN  MAXHOSTNAMELEN
                   .Dv TIOCGPGRP )     TIOCGPGRP)

     It is an error to call ‘.Dv’ without arguments.  ‘.Dv’ is parsed and is callable.

   Errno's (Section two only)
     The ‘.Er’ errno macro specifies the error return value for section two library routines.  The second
     example below shows ‘.Er’ used with the ‘.Bq’ general text domain macro, as it would be used in a section
     two manual page.

           Usage: .Er ERRNOTYPE ... [.,:;()[]?!]
                   .Er ENOENT      ENOENT
                   .Er ENOENT ) ;  ENOENT);
                   .Bq Er ENOTDIR  [ENOTDIR]

     It is an error to call ‘.Er’ without arguments.  The ‘.Er’ macro is parsed and is callable.

   Environment Variables
     The ‘.Ev’ macro specifies an environment variable.

           Usage: .Ev argument ... [.,:;()[]?!]
                   .Ev DISPLAY        DISPLAY
                   .Ev PATH .         PATH.
                   .Ev PRINTER ) ) ,  PRINTER)),

     It is an error to call ‘.Ev’ without arguments.  The ‘.Ev’ macro is parsed and is callable.

   Function Argument
     The ‘.Fa’ macro is used to refer to function arguments (parameters) outside of the SYNOPSIS section of the
     manual or inside the SYNOPSIS section should a parameter list be too long for the ‘.Fn’ macro and the
     enclosure macros ‘.Fo’ and ‘.Fc’ must be used.  ‘.Fa’ may also be used to refer to structure members.

           Usage: .Fa function_argument ... [.,:;()[]?!]
                   .Fa d_namlen ) ) ,  d_namlen)),
                   .Fa iov_len         iov_len

     It is an error to call ‘.Fa’ without arguments.  ‘.Fa’ is parsed and is callable.

   Function Declaration
     The ‘.Fd’ macro is used in the SYNOPSIS section with section two or three functions.  The ‘.Fd’ macro does
     not call other macros and is not callable by other macros.

           Usage: .Fd include_file (or defined variable)

     In the SYNOPSIS section a ‘.Fd’ request causes a line break if a function has already been presented and a
     break has not occurred.  This leaves a nice vertical space in between the previous function call and the
     declaration for the next function.

   Flags
     The ‘.Fl’ macro handles command-line flags.  It prepends a dash, ‘-’, to the flag.  For interactive command
     flags, which are not prepended with a dash, the ‘.Cm’ (command modifier) macro is identical, but without
     the dash.

           Usage: .Fl argument ... [.,:;()[]?!]
                   .Fl           -
                   .Fl cfv       -cfv
                   .Fl cfv .     -cfv.
                   .Fl s v t     -s -v -t
                   .Fl - ,       --,
                   .Fl xyz ) ,   -xyz),

     The ‘.Fl’ macro without any arguments results in a dash representing stdin/stdout.  Note that giving ‘.Fl’
     a single dash, will result in two dashes.  The ‘.Fl’ macro is parsed and is callable.

   Functions (library routines)
     The .Fn macro is modeled on ANSI C conventions.

     Usage: .Fn [type] function [[type] parameters ... [ .,:;()[]?! ]]
     .Fn getchar                             getchar()
     .Fn strlen ) ,                          strlen()),
     .Fn "int align" "const * char *sptrs",  int align(const * char *sptrs),

     It is an error to call ‘.Fn’ without any arguments.  The ‘.Fn’ macro is parsed and is callable, note that
     any call to another macro signals the end of the ‘.Fn’ call (it will close-parenthesis at that point).

     For functions that have more than eight parameters (and this is rare), the macros ‘.Fo’ (function open) and
     ‘.Fc’ (function close) may be used with ‘.Fa’ (function argument) to get around the limitation.  For
     example:

           .Fo "int res_mkquery"
           .Fa "int op"
           .Fa "char *dname"
           .Fa "int class"
           .Fa "int type"
           .Fa "char *data"
           .Fa "int datalen"
           .Fa "struct rrec *newrr"
           .Fa "char *buf"
           .Fa "int buflen"
           .Fc

     Produces:

           int    res_mkquery(int op,    char *dname,    int class,    int type,    char *data,     int datalen,
           struct rrec *newrr, char *buf, int buflen)

     The ‘.Fo’ and ‘.Fc’ macros are parsed and are callable.  In the SYNOPSIS section, the function will always
     begin at the beginning of line.  If there is more than one function presented in the SYNOPSIS section and a
     function type has not been given, a line break will occur, leaving a nice vertical space between the
     current function name and the one prior.  At the moment, ‘.Fn’ does not check its word boundaries against
     troff line lengths and may split across a newline ungracefully.  This will be fixed in the near future.

   Function Type
     This macro is intended for the SYNOPSIS section.  It may be used anywhere else in the man page without
     problems, but its main purpose is to present the function type in kernel normal form for the SYNOPSIS of
     sections two and three (it causes a line break allowing the function name to appear on the next line).

           Usage: .Ft type ... [.,:;()[]?!]
                   .Ft struct stat  struct stat

     The ‘.Ft’ request is not callable by other macros.

   Interactive Commands
     The ‘.Ic’ macro designates an interactive or internal command.

           Usage: .Ic argument ... [.,:;()[]?!]
                   .Ic :wq                  :wq
                   .Ic do while {...}       do while {...}
                   .Ic setenv , unsetenv    setenv, unsetenv

     It is an error to call ‘.Ic’ without arguments.  The ‘.Ic’ macro is parsed and is callable.

   Name Macro
     The ‘.Nm’ macro is used for the document title or subject name.  It has the peculiarity of remembering the
     first argument it was called with, which should always be the subject name of the page.  When called
     without arguments, ‘.Nm’ regurgitates this initial name for the sole purpose of making less work for the
     author.  Note: a section two or three document function name is addressed with the ‘.Nm’ in the NAME
     section, and with ‘.Fn’ in the SYNOPSIS and remaining sections.  For interactive commands, such as the
     ‘while’ command keyword in csh(1), the ‘.Ic’ macro should be used.  While the ‘.Ic’ is nearly identical to
     ‘.Nm’, it can not recall the first argument it was invoked with.

           Usage: .Nm argument ... [.,:;()[]?!]
                   .Nm mdoc.sample  mdoc.sample
                   .Nm \-mdoc       -mdoc.
                   .Nm foo ) ) ,    foo)),
                   .Nm              mdoc.samples

     The ‘.Nm’ macro is parsed and is callable.

   Options
     The ‘.Op’ macro places option brackets around the any remaining arguments on the command line, and places
     any trailing punctuation outside the brackets.  The macros ‘.Oc’ and ‘.Oo’ may be used across one or more
     lines.

           Usage: .Op options ... [.,:;()[]?!]
           .Op                                []
           .Op Fl k                           [-k]
           .Op Fl k ) .                       [-k]).
           .Op Fl k Ar kookfile               [-k kookfile]
           .Op Fl k Ar kookfile ,             [-k kookfile],
           .Op Ar objfil Op Ar corfil         [objfil [corfil]]
           .Op Fl c Ar objfil Op Ar corfil ,  [-c objfil [corfil]],
           .Op word1 word2                    [word1 word2]

     The ‘.Oc’ and ‘.Oo’ macros:

           .Oo
           .Op Fl k Ar kilobytes
           .Op Fl i Ar interval
           .Op Fl c Ar count
           .Oc

     Produce: [[-k kilobytes] [-i interval] [-c count]]

     The macros ‘.Op’, ‘.Oc’ and ‘.Oo’ are parsed and are callable.

   Pathnames
     The ‘.Pa’ macro formats pathnames or filenames.

           Usage: .Pa pathname [.,:;()[]?!]
                   .Pa /usr/share         /usr/share
                   .Pa /tmp/fooXXXXX ) .  /tmp/fooXXXXX).

     The ‘.Pa’ macro is parsed and is callable.

   Variables
     Generic variable reference:

           Usage: .Va variable ... [.,:;()[]?!]
                   .Va count           count
                   .Va settimer,       settimer,
                   .Va int *prt ) :    int *prt):
                   .Va char s ] ) ) ,  char s])),

     It is an error to call ‘.Va’ without any arguments.  The ‘.Va’ macro is parsed and is callable.

   Manual Page Cross References
     The ‘.Xr’ macro expects the first argument to be a manual page name, and the second argument, if it exists,
     to be either a section page number or punctuation.  Any remaining arguments are assumed to be punctuation.

           Usage: .Xr man_page [1,...,8] [.,:;()[]?!]
                   .Xr mdoc          mdoc
                   .Xr mdoc ,        mdoc,
                   .Xr mdoc 7        mdoc(7)
                   .Xr mdoc 7 ) ) ,  mdoc(7))),

     The ‘.Xr’ macro is parsed and is callable.  It is an error to call ‘.Xr’ without any arguments.

GENERAL TEXT DOMAIN

   AT&T Macro
           Usage: .At [v6 | v7 | 32v | V.1 | V.4] ... [ .,:;()[]?! ]
                   .At         AT&T UNIX
                   .At v6 .    Version 6 AT&T UNIX.

     The ‘.At’ macro is not parsed and not callable It accepts at most two arguments.

   BSD Macro
           Usage: .Bx [Version/release] ... [.,:;()[]?!]
                   .Bx          BSD
                   .Bx 4.3 .    4.3BSD.

     The ‘.Bx’ macro is parsed and is callable.

   FreeBSD Macro
           Usage: .Fx Version.release ... [ .,:;()[]?! ]
                   .Fx 2.2 .    FreeBSD 2.2.

     The ‘.Fx’ macro is not parsed and not callable It accepts at most two arguments.

   UNIX Macro
           Usage: .Ux ... [.,:;()[]?!]
                   .Ux          UNIX

     The ‘.Ux’ macro is parsed and is callable.

   Enclosure and Quoting Macros
     The concept of enclosure is similar to quoting.  The object being to enclose one or more strings between a
     pair of characters like quotes or parentheses.  The terms quoting and enclosure are used interchangeably
     throughout this document.  Most of the one line enclosure macros end in small letter ‘q’ to give a hint of
     quoting, but there are a few irregularities.  For each enclosure macro there is also a pair of open and
     close macros which end in small letters ‘o’ and ‘c’ respectively.  These can be used across one or more
     lines of text and while they have nesting limitations, the one line quote macros can be used inside of
     them.

            Quote    Close    Open   Function                  Result
           .Aq      .Ac      .Ao     Angle Bracket Enclosure   <string>
           .Bq      .Bc      .Bo     Bracket Enclosure         [string]
           .Dq      .Dc      .Do     Double Quote              ``string''
                    .Ec      .Eo     Enclose String (in XX)    XXstringXX
           .Pq      .Pc      .Po     Parenthesis Enclosure     (string)
           .Ql                       Quoted Literal            `st' or string
           .Qq      .Qc      .Qo     Straight Double Quote     "string"
           .Sq      .Sc      .So     Single Quote              `string'

     Except for the irregular macros noted below, all of the quoting macros are parsed and callable.  All handle
     punctuation properly, as long as it is presented one character at a time and separated by spaces.  The
     quoting macros examine opening and closing punctuation to determine whether it comes before or after the
     enclosing string This makes some nesting possible.

     .Ec, .Eo  These macros expect the first argument to be the opening and closing strings respectively.

     .Ql       The quoted literal macro behaves differently for troff than nroff.  If formatted with nroff, a
               quoted literal is always quoted.  If formatted with troff, an item is quoted only if the width of
               the item is less than three constant width characters.  This is to make short strings more
               visible where the font change to literal (constant width) is less noticeable.

     .Pf       The prefix macro is not callable, but it is parsed:

                     .Pf ( Fa name2
                              becomes (name2.

               The ‘.Ns’ (no space) macro performs the analogous suffix function.

     Examples of quoting:
           .Aq                         ⟨⟩
           .Aq Ar ctype.h ) ,          ⟨ctype.h⟩),
           .Bq                         []
           .Bq Em Greek , French .     [Greek, French].
           .Dq                         “”
           .Dq string abc .            “string abc”.
           .Dq ´^[A-Z]´                “´^[A-Z]´”
           .Ql man mdoc                ‘man mdoc’
           .Qq                         ""
           .Qq string ) ,              "string"),
           .Qq string Ns ),            "string),"
           .Sq                         ‘’
           .Sq string                  ‘string’

     For a good example of nested enclosure macros, see the ‘.Op’ option macro.  It was created from the same
     underlying enclosure macros as those presented in the list above.  The ‘.Xo’ and ‘.Xc’ extended argument
     list macros were also built from the same underlying routines and are a good example of -mdoc macro usage
     at its worst.

   No-Op or Normal Text Macro
     The macro ‘.No’ is a hack for words in a macro command line which should not be formatted and follows the
     conventional syntax for content macros.

   Space Macro
     The ‘.Ns’ macro eliminates unwanted spaces in between macro requests.  It is useful for old style argument
     lists where there is no space between the flag and argument:

           .Op Fl I Ns Ar directory    produces [-Idirectory]

     Note: the ‘.Ns’ macro always invokes the ‘.No’ macro after eliminating the space unless another macro name
     follows it.  The macro ‘.Ns’ is parsed and is callable.

   Section Cross References
     The ‘.Sx’ macro designates a reference to a section header within the same document.  It is parsed and is
     callable.

                   .Sx FILES     FILES

   References and Citations
     The following macros make a modest attempt to handle references.  At best, the macros make it convenient to
     manually drop in a subset of refer style references.

           .Rs     Reference Start.  Causes a line break and begins collection of reference information until
                   the reference end macro is read.
           .Re     Reference End.  The reference is printed.
           .%A     Reference author name, one name per invocation.
           .%B     Book title.
           .%C     City/place.
           .%D     Date.
           .%J     Journal name.
           .%N     Issue number.
           .%O     Optional information.
           .%P     Page number.
           .%R     Report name.
           .%T     Title of article.
           .%V     Volume(s).

     The macros beginning with ‘%’ are not callable, and are parsed only for the trade name macro which returns
     to its caller.  (And not very predictably at the moment either.)  The purpose is to allow trade names to be
     pretty printed in troff/ditroff output.

   Return Values
     The ‘.Rv’ macro generates text for use in the RETURN VALUE section.

           Usage: .Rv [-std function]

     ‘.Rv -std atexit’ will generate the following text:

     The atexit() function returns the value 0 if successful; otherwise the value -1 is returned and the global
     variable errno is set to indicate the error.

     The -std option is valid only for manual page sections 2 and 3.

   Trade Names (or Acronyms and Type Names)
     The trade name macro is generally a small caps macro for all uppercase words longer than two characters.

           Usage: .Tn symbol ... [.,:;()[]?!]
                   .Tn DEC    DEC
                   .Tn ASCII  ASCII

     The ‘.Tn’ macro is parsed and is callable by other macros.

   Extended Arguments
     The ‘.Xo’ and ‘.Xc’ macros allow one to extend an argument list on a macro boundary.  Argument lists cannot
     be extended within a macro which expects all of its arguments on one line such as ‘.Op’.

     Here is an example of ‘.Xo’ using the space mode macro to turn spacing off:

           .Sm off
           .It Xo Sy I Ar operation
           .No \en Ar count No \en
           .Xc
           .Sm on

     Produces

           Ioperation\ncount\n

     Another one:

           .Sm off
           .It Cm S No / Ar old_pattern Xo
           .No / Ar new_pattern
           .No / Op Cm g
           .Xc
           .Sm on

     Produces

           S/old_pattern/new_pattern/[g]

     Another example of ‘.Xo’ and using enclosure macros: Test the value of a variable.

           .It Xo
           .Ic .ifndef
           .Oo \&! Oc Ns Ar variable
           .Op Ar operator variable ...
           .Xc

     Produces

           .ifndef [!]variable [operator variable ...]

     All of the above examples have used the ‘.Xo’ macro on the argument list of the ‘.It’ (list-item) macro.
     The extend macros are not used very often, and when they are it is usually to extend the list-item argument
     list.  Unfortunately, this is also where the extend macros are the most finicky.  In the first two
     examples, spacing was turned off; in the third, spacing was desired in part of the output but not all of
     it.  To make these macros work in this situation make sure the ‘.Xo’ and ‘.Xc’ macros are placed as shown
     in the third example.  If the ‘.Xo’ macro is not alone on the ‘.It’ argument list, spacing will be
     unpredictable.  The ‘.Ns’ (no space macro) must not occur as the first or last macro on a line in this
     situation.  Out of 900 manual pages (about 1500 actual pages) currently released with BSD only fifteen use
     the ‘.Xo’ macro.

PAGE STRUCTURE DOMAIN

   Section Headers
     The first three ‘.Sh’ section header macros list below are required in every man page.  The remaining
     section headers are recommended at the discretion of the author writing the manual page.  The ‘.Sh’ macro
     can take up to nine arguments.  It is parsed and but is not callable.

     .Sh NAME      The ‘.Sh NAME’ macro is mandatory.  If not specified, the headers, footers and page layout
                   defaults will not be set and things will be rather unpleasant.  The NAME section consists of
                   at least three items.  The first is the ‘.Nm’ name macro naming the subject of the man page.
                   The second is the Name Description macro, ‘.Nd’, which separates the subject name from the
                   third item, which is the description.  The description should be the most terse and lucid
                   possible, as the space available is small.

     .Sh SYNOPSIS  The SYNOPSIS section describes the typical usage of the subject of a man page.  The macros
                   required are either ‘.Nm’, ‘.Cd’, ‘.Fn’, (and possibly ‘.Fo’, ‘.Fc’, ‘.Fd’, ‘.Ft’ macros).
                   The function name macro ‘.Fn’ is required for manual page sections 2 and 3, the command and
                   general name macro ‘.Nm’ is required for sections 1, 5, 6, 7, 8.  Section 4 manuals require a
                   ‘.Nm’, ‘.Fd’ or a ‘.Cd’ configuration device usage macro.  Several other macros may be
                   necessary to produce the synopsis line as shown below:

           cat [-benstuv] [-] file ...

     The following macros were used:

           .Nm cat
           .Op Fl benstuv
           .Op Fl
           .Ar

     Note: The macros ‘.Op’, ‘.Fl’, and ‘.Ar’ recognize the pipe bar character ‘|’, so a command line such as:

           .Op Fl a | Fl b

     will not go orbital.  Troff normally interprets a | as a special operator.  See PREDEFINED STRINGS for a
     usable | character in other situations.

     .Sh DESCRIPTION
             In most cases the first text in the DESCRIPTION section is a brief paragraph on the command,
             function or file, followed by a lexical list of options and respective explanations.  To create
             such a list, the ‘.Bl’ begin-list, ‘.It’ list-item and ‘.El’ end-list macros are used (see Lists
             and Columns below).

     The following ‘.Sh’ section headers are part of the preferred manual page layout and must be used
     appropriately to maintain consistency.  They are listed in the order in which they would be used.

     .Sh ENVIRONMENT
               The ENVIRONMENT section should reveal any related environment variables and clues to their
               behavior and/or usage.

     .Sh EXAMPLES
               There are several ways to create examples.  See the EXAMPLES section below for details.

     .Sh FILES
               Files which are used or created by the man page subject should be listed via the ‘.Pa’ macro in
               the FILES section.

     .Sh SEE ALSO
               References to other material on the man page topic and cross references to other relevant man
               pages should be placed in the SEE ALSO section.  Cross references are specified using the ‘.Xr’
               macro.  Cross references in the SEE ALSO section should be sorted by section number, and then
               placed in alphabetical order and comma separated.  For example:

               ls(1), ps(1), group(5), passwd(5).

               At this time refer(1) style references are not accommodated.

     .Sh CONFORMING TO
               If the command, library function or file adheres to a specific implementation such as IEEE Std
               1003.2 (“POSIX.2”) or ANSI X3.159-1989 (“ANSI C89”) this should be noted here.  If the command
               does not adhere to any standard, its history should be noted in the HISTORY section.

     .Sh HISTORY
               Any command which does not adhere to any specific standards should be outlined historically in
               this section.

     .Sh AUTHORS
               Credits, if need be, should be placed here.

     .Sh DIAGNOSTICS
               Diagnostics from a command should be placed in this section.

     .Sh ERRORS
               Specific error handling, especially from library functions (man page sections 2 and 3) should go
               here.  The ‘.Er’ macro is used to specify an errno.

     .Sh BUGS  Blatant problems with the topic go here...

     User specified ‘.Sh’ sections may be added, for example, this section was set with:

                   .Sh PAGE STRUCTURE DOMAIN

   Paragraphs and Line Spacing.
     .Pp     The ‘.Pp’ paragraph command may be used to specify a line space where necessary.  The macro is not
             necessary after a ‘.Sh’ or ‘.Ss’ macro or before a ‘.Bl’ macro.  (The ‘.Bl’ macro asserts a
             vertical distance unless the -compact flag is given).

   Keeps
     The only keep that is implemented at this time is for words.  The macros are ‘.Bk’ (begin-keep) and ‘.Ek’
     (end-keep).  The only option that ‘.Bk’ accepts is -words and is useful for preventing line breaks in the
     middle of options.  In the example for the make command-line arguments (see What's in a name), the keep
     prevented nroff from placing up the flag and the argument on separate lines.  (Actually, the option macro
     used to prevent this from occurring, but was dropped when the decision (religious) was made to force right
     justified margins in troff as options in general look atrocious when spread across a sparse line.  More
     work needs to be done with the keep macros, a -line option needs to be added.)

   Examples and Displays
     There are five types of displays, a quickie one line indented display ‘.D1’, a quickie one line literal
     display ‘.Dl’, and a block literal, block filled and block ragged which use the ‘.Bd’ begin-display and
     ‘.Ed’ end-display macros.

     .D1    (D-one) Display one line of indented text.  This macro is parsed, but it is not callable.

                  -ldghfstru

            The above was produced by: .Dl -ldghfstru.

     .Dl    (D-ell) Display one line of indented literal text.  The ‘.Dl’ example macro has been used throughout
            this file.  It allows the indent (display) of one line of text.  Its default font is set to constant
            width (literal) however it is parsed and will recognized other macros.  It is not callable however.

                  % ls -ldg /usr/local/bin

            The above was produced by .Dl % ls -ldg /usr/local/bin.

     .Bd    Begin-display.  The ‘.Bd’ display must be ended with the ‘.Ed’ macro.  Displays may be nested within
            displays and lists.  ‘.Bd’ has the following syntax:

                  .Bd display-type [-offset offset_value] [-compact]

            The display-type must be one of the following four types and may have an offset specifier for
            indentation: ‘.Bd’.

     -ragged           Display a block of text as typed, right (and left) margin edges are left ragged.
     -filled           Display a filled (formatted) block.  The block of text is formatted (the edges are filled
                       - not left unjustified).
     -literal          Display a literal block, useful for source code or simple tabbed or spaced text.
     -file file_name   The filename following the -file flag is read and displayed.  Literal mode is asserted
                       and tabs are set at 8 constant width character intervals, however any troff/-mdoc
                       commands in file will be processed.
     -offset string    If -offset is specified with one of the following strings, the string is interpreted to
                       indicate the level of indentation for the forthcoming block of text:

                       left        Align block on the current left margin, this is the default mode of ‘.Bd’.
                       center      Supposedly center the block.  At this time unfortunately, the block merely
                                   gets left aligned about an imaginary center margin.
                       indent      Indents by one default indent value or tab.  The default indent value is also
                                   used for the ‘.D1’ display so one is guaranteed the two types of displays
                                   will line up.  This indent is normally set to 6n or about two thirds of an
                                   inch (six constant width characters).
                       indent-two  Indents two times the default indent value.
                       right       This left aligns the block about two inches from the right side of the page.
                                   This macro needs work and perhaps may never do the right thing by troff.
     .Ed               End-display.

   Font Modes
     There are five macros for changing the appearance of the manual page text:

     .Em    Text may be stressed or emphasized with the ‘.Em’ macro.  The usual font for emphasis is italic.

                  Usage: .Em argument ... [.,:;()[]?!]
                          .Em does not          does not
                          .Em exceed 1024 .     exceed 1024.
                          .Em vide infra ) ) ,  vide infra)),

            The ‘.Em’ macro is parsed and is callable.  It is an error to call ‘.Em’ without arguments.

     .Li    The ‘.Li’ literal macro may be used for special characters, variable constants, anything which
            should be displayed as it would be typed.

                  Usage: .Li argument ... [.,:;()[]?!]
                          .Li \en          \n
                          .Li M1 M2 M3 ;   M1 M2 M3;
                          .Li cntrl-D ) ,  cntrl-D),
                          .Li 1024 ...     1024 ...

            The ‘.Li’ macro is parsed and is callable.

     .Sy    The symbolic emphasis macro is generally a boldface macro in either the symbolic sense or the
            traditional English usage.

                  Usage: .Sy symbol ... [.,:;()[]?!]
                          .Sy Important Notice   Important Notice

                                                 The ‘.Sy’ macro is parsed and is callable.  Arguments to ‘.Sy’
                                                 may be quoted.

     .Bf    Begin font mode.  The ‘.Bf’ font mode must be ended with the ‘.Ef’ macro.  Font modes may be nested
            within other font modes.  ‘.Bf’ has the following syntax:

                  .Bf font-mode

            The font-mode must be one of the following three types: ‘.Bf’.

            Em | -emphasis    Same as if the ‘.Em’ macro was used for the entire block of text.
            Li | -literal     Same as if the ‘.Li’ macro was used for the entire block of text.
            Sy | -symbolic    Same as if the ‘.Sy’ macro was used for the entire block of text.

     .Ef    End font mode.

   Tagged Lists and Columns
     There are several types of lists which may be initiated with the ‘.Bl’ begin-list macro.  Items within the
     list are specified with the ‘.It’ item macro and each list must end with the ‘.El’ macro.  Lists may be
     nested within themselves and within displays.  Columns may be used inside of lists, but lists are unproven
     inside of columns.

     In addition, several list attributes may be specified such as the width of a tag, the list offset, and
     compactness (blank lines between items allowed or disallowed).  Most of this document has been formatted
     with a tag style list (-tag).  For a change of pace, the list-type used to present the list-types is an
     over-hanging list (-ohang).  This type of list is quite popular with TeX users, but might look a bit funny
     after having read many pages of tagged lists.  The following list types are accepted by ‘.Bl’:

     -bullet
     -item
     -enum
     These three are the simplest types of lists.  Once the ‘.Bl’ macro has been given, items in the list are
     merely indicated by a line consisting solely of the ‘.It’ macro.  For example, the source text for a simple
     enumerated list would look like:

                 .Bl -enum -compact
                 .It
                 Item one goes here.
                 .It
                 And item two here.
                 .It
                 Lastly item three goes here.
                 .El

     The results:

               1.   Item one goes here.
               2.   And item two here.
               3.   Lastly item three goes here.

     A simple bullet list construction:

                 .Bl -bullet -compact
                 .It
                 Bullet one goes here.
                 .It
                 Bullet two here.
                 .El

     Produces:
                  Bullet one goes here.
                  Bullet two here.

     -tag
     -diag
     -hang
     -ohang
     -inset
     These list-types collect arguments specified with the ‘.It’ macro and create a label which may be inset
     into the forthcoming text, hanged from the forthcoming text, overhanged from above and not indented or
     tagged.  This list was constructed with the ‘Fl ohang’ list-type.  The ‘.It’ macro is parsed only for the
     inset, hang and tag list-types and is not callable.  Here is an example of inset labels:

           Tag The tagged list (also called a tagged paragraph) is the most common type of list used in the
           Berkeley manuals.

           Diag Diag lists create section four diagnostic lists and are similar to inset lists except callable
           macros are ignored.

           Hang Hanged labels are a matter of taste.

           Ohang Overhanging labels are nice when space is constrained.

           Inset Inset labels are useful for controlling blocks of paragraphs and are valuable for converting
           -mdoc manuals to other formats.

     Here is the source text which produced the above example:

           .Bl -inset -offset indent
           .It Em Tag
           The tagged list (also called a tagged paragraph) is the
           most common type of list used in the Berkeley manuals.
           .It Em Diag
           Diag lists create section four diagnostic lists
           and are similar to inset lists except callable
           macros are ignored.
           .It Em Hang
           Hanged labels are a matter of taste.
           .It Em Ohang
           Overhanging labels are nice when space is constrained.
           .It Em Inset
           Inset labels are useful for controlling blocks of
           paragraphs and are valuable for converting
           .Nm -mdoc
           manuals to other formats.
           .El

     Here is a hanged list with two items:

           Hanged  labels appear similar to tagged lists when the label is smaller than the label width.

           Longer hanged list labels blend in to the paragraph unlike tagged paragraph labels.

     And the unformatted text which created it:

           .Bl -hang -offset indent
           .It Em Hanged
           labels appear similar to tagged lists when the
           label is smaller than the label width.
           .It Em Longer hanged list labels
           blend in to the paragraph unlike
           tagged paragraph labels.
           .El

     The tagged list which follows uses an optional width specifier to control the width of the tag.

           SL      sleep time of the process (seconds blocked)
           PAGEIN  number of disk I/O's resulting from references by the process to pages not loaded in core.
           UID     numerical user-id of process owner
           PPID    numerical ID of parent of process process priority (nonpositive when in noninterruptible
                   wait)

     The raw text:

           .Bl -tag -width "PAGEIN" -compact -offset indent
           .It SL
           sleep time of the process (seconds blocked)
           .It PAGEIN
           number of disk
           .Tn I/O Ns 's
           resulting from references
           by the process to pages not loaded in core.
           .It UID
           numerical user ID of process owner
           .It PPID
           numerical ID of parent of process process priority
           (nonpositive when in noninterruptible wait)
           .El

     Acceptable width specifiers:

           -width Fl     sets the width to the default width for a flag.  All callable macros have a default
                         width value.  The ‘.Fl’, value is presently set to ten constant width characters or
                         about five sixth of an inch.

           -width 24n    sets the width to 24 constant width characters or about two inches.  The ‘n’ is
                         absolutely necessary for the scaling to work correctly.

           -width ENAMETOOLONG
                         sets width to the constant width length of the string given.

           -width "int mkfifo"
                         again, the width is set to the constant width of the string given.

     If a width is not specified for the tag list type, the first time ‘.It’ is invoked, an attempt is made to
     determine an appropriate width.  If the first argument to ‘.It’ is a callable macro, the default width for
     that macro will be used as if the macro name had been supplied as the width.  However, if another item in
     the list is given with a different callable macro name, a new and nested list is assumed.

PREDEFINED STRINGS

     The following strings are predefined as may be used by preceding with the troff string interpreting
     sequence ‘\*(xx’ where xx is the name of the defined string or as ‘\*x’ where x is the name of the string.
     The interpreting sequence may be used any where in the text.

           String     Nroff     Troff
           <=         <=        ≤
           >=         >=        ≥
           Rq         ''        ”
           Lq         ``        “
           ua         ^         ↑
           aa         '         ´
           ga         `         `
           q          "         "
           Pi         pi        π
           Ne         !=        ≠
           Le         <=        ≤
           Ge         >=        ≥
           Lt         <         >
           Gt         >         <
           Pm         +-        ±
           If         infinity  ∞
           Na         NaN       NaN
           Ba         |         |

     Note: The string named ‘q’ should be written as ‘\*q’ since it is only one char.

DIAGNOSTICS

     The debugging facilities for -mdoc are limited, but can help detect subtle errors such as the collision of
     an argument name with an internal register or macro name.  (A what?)  A register is an arithmetic storage
     class for troff with a one or two character name.  All registers internal to -mdoc for troff and ditroff
     are two characters and of the form <upper_case><lower_case> such as ‘Ar’, <lower_case><upper_case> as ‘aR’
     or <upper or lower letter><digit> as ‘C1’.  And adding to the muddle, troff has its own internal registers
     all of which are either two lowercase characters or a dot plus a letter or metacharacter character.  In one
     of the introduction examples, it was shown how to prevent the interpretation of a macro name with the
     escape sequence ‘\&’.  This is sufficient for the internal register names also.

     If a nonescaped register name is given in the argument list of a request, unpredictable behavior will
     occur.  In general, any time huge portions of text do not appear where expected in the output, or small
     strings such as list tags disappear, chances are there is a misunderstanding about an argument type in the
     argument list.  Your mother never intended for you to remember this evil stuff - so here is a way to find
     out whether or not your arguments are valid: The ‘.Db’ (debug) macro displays the interpretation of the
     argument list for most macros.  Macros such as the ‘.Pp’ (paragraph) macro do not contain debugging
     information.  All of the callable macros do, and it is strongly advised whenever in doubt, turn on the
     ‘.Db’ macro.

           Usage: .Db [on | off]

     An example of a portion of text with the debug macro placed above and below an artificially created problem
     (a flag argument ‘aC’ which should be ‘\&aC’ in order to work):

           .Db on
           .Op Fl aC Ar file )
           .Db off

     The resulting output:

           DEBUGGING ON
           DEBUG(argv) MACRO: `.Op'  Line #: 2
                   Argc: 1  Argv: `Fl'  Length: 2
                   Space: `'  Class: Executable
                   Argc: 2  Argv: `aC'  Length: 2
                   Space: `'  Class: Executable
                   Argc: 3  Argv: `Ar'  Length: 2
                   Space: `'  Class: Executable
                   Argc: 4  Argv: `file'  Length: 4
                   Space: ` '  Class: String
                   Argc: 5  Argv: `)'  Length: 1
                   Space: ` '  Class: Closing Punctuation or suffix
                   MACRO REQUEST: .Op Fl aC Ar file )
           DEBUGGING OFF

     The first line of information tells the name of the calling macro, here ‘.Op’, and the line number it
     appears on.  If one or more files are involved (especially if text from another file is included), the line
     number may be bogus.  If there is only one file, it should be accurate.  The second line gives the argument
     count, the argument (‘Fl’) and its length.  If the length of an argument is two characters, the argument is
     tested to see if it is executable (unfortunately, any register which contains a nonzero value appears
     executable).  The third line gives the space allotted for a class, and the class type.  The problem here is
     the argument aC should not be executable.  The four types of classes are string, executable, closing
     punctuation and opening punctuation.  The last line shows the entire argument list as it was read.  In this
     next example, the offending ‘aC’ is escaped:

           .Db on
           .Em An escaped \&aC
           .Db off

           DEBUGGING ON
           DEBUG(fargv) MACRO: `.Em'  Line #: 2
                   Argc: 1  Argv: `An'  Length: 2
                   Space: ` '  Class: String
                   Argc: 2  Argv: `escaped'  Length: 7
                   Space: ` '  Class: String
                   Argc: 3  Argv: `aC'  Length: 2
                   Space: ` '  Class: String
                   MACRO REQUEST: .Em An escaped &aC
           DEBUGGING OFF

     The argument ‘\&aC’ shows up with the same length of 2 as the ‘\&’ sequence produces a zero width, but a
     register named ‘\&aC’ was not found and the type classified as string.

     Other diagnostics consist of usage statements and are self explanatory.

GROFF, TROFF AND NROFF

     The -mdoc package does not need compatibility mode with groff.

     The package inhibits page breaks, and the headers and footers which normally occur at those breaks with
     nroff, to make the manual more efficient for viewing on-line.  At the moment, groff with -Tascii does eject
     the imaginary remainder of the page at end of file.  The inhibiting of the page breaks makes nroff'd files
     unsuitable for hardcopy.  There is a register named ‘cR’ which can be set to zero in the site dependent
     style file /usr/src/share/tmac/doc-nroff to restore the old style behavior.

FILES

     /usr/share/tmac/doc.tmac      manual macro package
     /usr/share/misc/mdoc.template
                                   template for writing a man page
     /usr/share/examples/mdoc/*    several example man pages

BUGS

     Undesirable hyphenation on the dash of a flag argument is not yet resolved, and causes occasional mishaps
     in the DESCRIPTION section.  (line break on the hyphen).

     Predefined strings are not declared in documentation.

     Section 3f has not been added to the header routines.

     ‘.Nm’ font should be changed in NAME section.

     ‘.Fn’ needs to have a check to prevent splitting up if the line length is too short.  Occasionally it
     separates the last parenthesis, and sometimes looks ridiculous if a line is in fill mode.

     The method used to prevent header and footer page breaks (other than the initial header and footer) when
     using nroff occasionally places an unsightly partially filled line (blank) at the would be bottom of the
     page.

     The list and display macros to not do any keeps and certainly should be able to.

SEE ALSO

     man(1), troff(1), groff_mdoc(7), mdoc(7)

COLOPHON

     This page is part of release 4.04 of the Linux man-pages project.  A description of the project,
     information about reporting bugs, and the latest version of this page, can be found at
     http://www.kernel.org/doc/man-pages/.