Provided by: ovn-common_24.03.2-0ubuntu0.24.04.1_amd64 bug

NAME

       ovn-architecture - Open Virtual Network architecture

DESCRIPTION

       OVN,  the  Open  Virtual  Network,  is  a system to support logical network abstraction in
       virtual machine and container environments. OVN complements the existing  capabilities  of
       OVS  to  add  native  support  for logical network abstractions, such as logical L2 and L3
       overlays and security groups. Services such as DHCP are also desirable features. Just like
       OVS,  OVN’s design goal is to have a production-quality implementation that can operate at
       significant scale.

       A physical network comprises physical wires, switches,  and  routers.  A  virtual  network
       extends  a  physical  network  into  a  hypervisor  or container platform, bridging VMs or
       containers into the physical network. An OVN logical network is a network  implemented  in
       software  that  is insulated from physical (and thus virtual) networks by tunnels or other
       encapsulations. This allows IP and other  address  spaces  used  in  logical  networks  to
       overlap  with  those  used on physical networks without causing conflicts. Logical network
       topologies can be arranged without regard for the topologies of the physical  networks  on
       which they run. Thus, VMs that are part of a logical network can migrate from one physical
       machine to another without network disruption.  See  Logical  Networks,  below,  for  more
       information.

       The  encapsulation  layer  prevents VMs and containers connected to a logical network from
       communicating with nodes on physical networks. For clustering VMs and containers, this can
       be acceptable or even desirable, but in many cases VMs and containers do need connectivity
       to physical networks. OVN provides multiple  forms  of  gateways  for  this  purpose.  See
       Gateways, below, for more information.

       An OVN deployment consists of several components:

              •      A  Cloud  Management  System  (CMS), which is OVN’s ultimate client (via its
                     users and  administrators).  OVN  integration  requires  installing  a  CMS-
                     specific  plugin  and  related  software  (see below). OVN initially targets
                     OpenStack as CMS.

                     We generally speak of ``the’’ CMS, but one can imagine  scenarios  in  which
                     multiple CMSes manage different parts of an OVN deployment.

              •      An OVN Database physical or virtual node (or, eventually, cluster) installed
                     in a central location.

              •      One or more (usually many) hypervisors. Hypervisors must  run  Open  vSwitch
                     and         implement        the        interface        described        in
                     Documentation/topics/integration.rst in the Open vSwitch  source  tree.  Any
                     hypervisor platform supported by Open vSwitch is acceptable.

              •      Zero or more gateways. A gateway extends a tunnel-based logical network into
                     a physical network by bidirectionally forwarding packets between tunnels and
                     a   physical   Ethernet   port.  This  allows  non-virtualized  machines  to
                     participate in logical networks. A gateway may be a physical host, a virtual
                     machine, or an ASIC-based hardware switch that supports the vtep(5) schema.

                     Hypervisors and gateways are together called transport node or chassis.

       The  diagram  below  shows  how the major components of OVN and related software interact.
       Starting at the top of the diagram, we have:

              •      The Cloud Management System, as defined above.

              •      The OVN/CMS Plugin is the component of the CMS that interfaces  to  OVN.  In
                     OpenStack,  this  is  a  Neutron  plugin.  The  plugin’s  main purpose is to
                     translate the CMS’s notion of logical network configuration, stored  in  the
                     CMS’s  configuration database in a CMS-specific format, into an intermediate
                     representation understood by OVN.

                     This component is necessarily CMS-specific, so a  new  plugin  needs  to  be
                     developed  for  each  CMS that is integrated with OVN. All of the components
                     below this one in the diagram are CMS-independent.

              •      The OVN Northbound Database  receives  the  intermediate  representation  of
                     logical  network  configuration  passed  down  by  the  OVN/CMS  Plugin. The
                     database schema is meant to be ``impedance matched’’ with the concepts  used
                     in a CMS, so that it directly supports notions of logical switches, routers,
                     ACLs, and so on. See ovn-nb(5) for details.

                     The OVN Northbound Database has only two clients: the OVN/CMS  Plugin  above
                     it and ovn-northd below it.

              •      ovn-northd(8)  connects  to the OVN Northbound Database above it and the OVN
                     Southbound  Database  below  it.   It   translates   the   logical   network
                     configuration  in terms of conventional network concepts, taken from the OVN
                     Northbound Database, into logical  datapath  flows  in  the  OVN  Southbound
                     Database below it.

              •      The  OVN  Southbound  Database  is the center of the system. Its clients are
                     ovn-northd(8) above it and ovn-controller(8) on every transport  node  below
                     it.

                     The  OVN  Southbound Database contains three kinds of data: Physical Network
                     (PN) tables that specify how to reach hypervisor and  other  nodes,  Logical
                     Network  (LN) tables that describe the logical network in terms of ``logical
                     datapath flows,’’ and Binding tables that link logical  network  components’
                     locations  to  the  physical  network.  The  hypervisors populate the PN and
                     Port_Binding tables, whereas ovn-northd(8) populates the LN tables.

                     OVN Southbound Database performance must scale with the number of  transport
                     nodes. This will likely require some work on ovsdb-server(1) as we encounter
                     bottlenecks. Clustering for availability may be needed.

       The remaining components are replicated onto each hypervisor:

              •      ovn-controller(8) is OVN’s agent on each hypervisor  and  software  gateway.
                     Northbound,  it  connects  to the OVN Southbound Database to learn about OVN
                     configuration and status and to populate the PN table and the Chassis column
                     in  Binding  table  with the hypervisor’s status. Southbound, it connects to
                     ovs-vswitchd(8) as an OpenFlow controller, for control over network traffic,
                     and  to  the  local  ovsdb-server(1) to allow it to monitor and control Open
                     vSwitch configuration.

              •      ovs-vswitchd(8) and ovsdb-server(1)  are  conventional  components  of  Open
                     vSwitch.

                                         CMS
                                          |
                                          |
                              +-----------|-----------+
                              |           |           |
                              |     OVN/CMS Plugin    |
                              |           |           |
                              |           |           |
                              |   OVN Northbound DB   |
                              |           |           |
                              |           |           |
                              |       ovn-northd      |
                              |           |           |
                              +-----------|-----------+
                                          |
                                          |
                                +-------------------+
                                | OVN Southbound DB |
                                +-------------------+
                                          |
                                          |
                       +------------------+------------------+
                       |                  |                  |
         HV 1          |                  |    HV n          |
       +---------------|---------------+  .  +---------------|---------------+
       |               |               |  .  |               |               |
       |        ovn-controller         |  .  |        ovn-controller         |
       |         |          |          |  .  |         |          |          |
       |         |          |          |     |         |          |          |
       |  ovs-vswitchd   ovsdb-server  |     |  ovs-vswitchd   ovsdb-server  |
       |                               |     |                               |
       +-------------------------------+     +-------------------------------+

   Information Flow in OVN
       Configuration  data in OVN flows from north to south. The CMS, through its OVN/CMS plugin,
       passes the logical network configuration to ovn-northd via  the  northbound  database.  In
       turn,  ovn-northd  compiles the configuration into a lower-level form and passes it to all
       of the chassis via the southbound database.

       Status information in OVN flows from south to north. OVN currently  provides  only  a  few
       forms  of  status information. First, ovn-northd populates the up column in the northbound
       Logical_Switch_Port  table:  if  a  logical  port’s  chassis  column  in  the   southbound
       Port_Binding  table  is  nonempty, it sets up to true, otherwise to false. This allows the
       CMS to detect when a VM’s networking has come up.

       Second, OVN provides feedback to the CMS on the realization of its configuration, that is,
       whether  the configuration provided by the CMS has taken effect. This feature requires the
       CMS to participate in a sequence number protocol, which works the following way:

              1.  When the CMS updates the configuration in the northbound database, as  part  of
                  the  same  transaction,  it  increments  the  value of the nb_cfg column in the
                  NB_Global table. (This is only necessary if the CMS  wants  to  know  when  the
                  configuration has been realized.)

              2.  When  ovn-northd  updates  the southbound database based on a given snapshot of
                  the northbound database, it copies nb_cfg from northbound  NB_Global  into  the
                  southbound database SB_Global table, as part of the same transaction. (Thus, an
                  observer monitoring both databases can determine when the  southbound  database
                  is caught up with the northbound.)

              3.  After ovn-northd receives confirmation from the southbound database server that
                  its changes have committed, it updates sb_cfg in the northbound NB_Global table
                  to  the nb_cfg version that was pushed down. (Thus, the CMS or another observer
                  can determine when the southbound database is caught up without a connection to
                  the southbound database.)

              4.  The  ovn-controller  process  on  each  chassis receives the updated southbound
                  database, with the updated nb_cfg. This process in turn  updates  the  physical
                  flows  installed  in  the  chassis’s  Open  vSwitch instances. When it receives
                  confirmation from Open vSwitch that the physical flows have  been  updated,  it
                  updates nb_cfg in its own Chassis record in the southbound database.

              5.  ovn-northd  monitors  the  nb_cfg  column  in all of the Chassis records in the
                  southbound database. It keeps track of the minimum value among all the  records
                  and  copies it into the hv_cfg column in the northbound NB_Global table. (Thus,
                  the CMS or another observer can determine when  all  of  the  hypervisors  have
                  caught up to the northbound configuration.)

   Chassis Setup
       Each chassis in an OVN deployment must be configured with an Open vSwitch bridge dedicated
       for OVN’s use, called the integration bridge.  System  startup  scripts  may  create  this
       bridge  prior  to  starting  ovn-controller if desired. If this bridge does not exist when
       ovn-controller starts, it will be created automatically  with  the  default  configuration
       suggested below. The ports on the integration bridge include:

              •      On  any  chassis,  tunnel  ports  that  OVN uses to maintain logical network
                     connectivity. ovn-controller adds, updates, and removes these tunnel ports.

              •      On a hypervisor, any VIFs that are to be attached to logical  networks.  For
                     instances  connected through software emulated ports such as TUN/TAP or VETH
                     pairs, the hypervisor itself will normally create ports and plug  them  into
                     the  integration  bridge. For instances connected through representor ports,
                     typically  used  with  hardware  offload,  the  ovn-controller  may  on  CMS
                     direction  consult  a VIF plug provider for representor port lookup and plug
                     them    into     the     integration     bridge     (please     refer     to
                     Documentation/topics/vif-plug-providers/vif-plug-providers.rst
                      for   more  information).  In  both  cases  the  conventions  described  in
                     Documentation/topics/integration.rst in the  Open  vSwitch  source  tree  is
                     followed  to  ensure mapping between OVN logical port and VIF. (This is pre-
                     existing integration work that has already been  done  on  hypervisors  that
                     support OVS.)

              •      On  a  gateway,  the  physical  port  used for logical network connectivity.
                     System startup scripts add  this  port  to  the  bridge  prior  to  starting
                     ovn-controller.  This  can  be  a patch port to another bridge, instead of a
                     physical port, in more sophisticated setups.

       Other ports should not be attached to the  integration  bridge.  In  particular,  physical
       ports  attached  to  the underlay network (as opposed to gateway ports, which are physical
       ports attached to logical networks) must  not  be  attached  to  the  integration  bridge.
       Underlay physical ports should instead be attached to a separate Open vSwitch bridge (they
       need not be attached to any bridge at all, in fact).

       The integration bridge should be configured as described below.  The  effect  of  each  of
       these settings is documented in ovs-vswitchd.conf.db(5):

              fail-mode=secure
                     Avoids   switching   packets   between   isolated  logical  networks  before
                     ovn-controller starts up. See Controller Failure  Settings  in  ovs-vsctl(8)
                     for more information.

              other-config:disable-in-band=true
                     Suppresses  in-band  control  flows  for the integration bridge. It would be
                     unusual for such  flows  to  show  up  anyway,  because  OVN  uses  a  local
                     controller  (over a Unix domain socket) instead of a remote controller. It’s
                     possible, however, for some other bridge in the same system to have  an  in-
                     band  remote controller, and in that case this suppresses the flows that in-
                     band control would ordinarily set up. Refer to the  documentation  for  more
                     information.

       The customary name for the integration bridge is br-int, but another name may be used.

   Logical Networks
       Logical  network concepts in OVN include logical switches and logical routers, the logical
       version of Ethernet switches and IP routers, respectively. Like  their  physical  cousins,
       logical  switches  and  routers  can  be  connected into sophisticated topologies. Logical
       switches and routers are ordinarily  purely  logical  entities,  that  is,  they  are  not
       associated  or  bound  to any physical location, and they are implemented in a distributed
       manner at each hypervisor that participates in OVN.

       Logical switch ports (LSPs) are points of connectivity into and out of  logical  switches.
       There  are many kinds of logical switch ports. The most ordinary kind represent VIFs, that
       is, attachment points for VMs or containers. A VIF logical port  is  associated  with  the
       physical  location  of  its VM, which might change as the VM migrates. (A VIF logical port
       can be associated with a VM that is powered down or suspended. Such a logical port has  no
       location and no connectivity.)

       Logical  router ports (LRPs) are points of connectivity into and out of logical routers. A
       LRP connects a logical router either to a logical switch or  to  another  logical  router.
       Logical  routers  only  connect  to  VMs,  containers, and other network nodes indirectly,
       through logical switches.

       Logical switches and logical routers have distinct kinds of  logical  ports,  so  properly
       speaking  one  should  usually  talk  about  logical switch ports or logical router ports.
       However, an unqualified ``logical port’’ usually refers to a logical switch port.

       When a VM sends a packet to a VIF logical  switch  port,  the  Open  vSwitch  flow  tables
       simulate  the  packet’s  journey through that logical switch and any other logical routers
       and logical switches that it might encounter. This happens without transmitting the packet
       across  any  physical  medium:  the flow tables implement all of the switching and routing
       decisions and behavior. If the flow tables ultimately decide to output  the  packet  at  a
       logical port attached to another hypervisor (or another kind of transport node), then that
       is the time at which the packet is encapsulated  for  physical  network  transmission  and
       sent.

     Logical Switch Port Types

       OVN  supports  a number of kinds of logical switch ports. VIF ports that connect to VMs or
       containers, described above, are the most ordinary kind of  LSP.  In  the  OVN  northbound
       database,  VIF  ports  have an empty string for their type. This section describes some of
       the additional port types.

       A router logical switch port connects a logical switch to a logical router, designating  a
       particular LRP as its peer.

       A  localnet  logical  switch  port  bridges a logical switch to a physical VLAN. A logical
       switch may have one or more  localnet  ports.  Such  a  logical  switch  is  used  in  two
       scenarios:

              •      With  one  or more router logical switch ports, to attach L3 gateway routers
                     and distributed gateways to a physical network.

              •      With one or more VIF logical switch  ports,  to  attach  VMs  or  containers
                     directly  to  a  physical  network.  In this case, the logical switch is not
                     really logical, since it is bridged to  the  physical  network  rather  than
                     insulated  from it, and therefore cannot have independent but overlapping IP
                     address namespaces, etc. A  deployment  might  nevertheless  choose  such  a
                     configuration  to  take advantage of the OVN control plane and features such
                     as port security and ACLs.

       When a logical switch contains multiple localnet ports, the following is assumed.

              •      Each chassis has a bridge mapping for one of the localnet physical  networks
                     only.

              •      To  facilitate  interconnectivity  between  VIF ports of the switch that are
                     located on different chassis with different physical  network  connectivity,
                     the  fabric  implements  L3  routing between these adjacent physical network
                     segments.

       Note: nothing said above implies that a chassis cannot be  plugged  to  multiple  physical
       networks as long as they belong to different switches.

       A  localport logical switch port is a special kind of VIF logical switch port. These ports
       are present in every chassis, not bound to any particular one. Traffic to such a port will
       never  be  forwarded  through  a  tunnel,  and  traffic from such a port is expected to be
       destined only to the same chassis,  typically  in  response  to  a  request  it  received.
       OpenStack Neutron uses a localport port to serve metadata to VMs. A metadata proxy process
       is attached to this port on every host and all VMs within the same network will  reach  it
       at  the  same  IP/MAC  address  without  any traffic being sent over a tunnel. For further
       details, see the OpenStack documentation for networking-ovn.

       LSP types vtep and l2gateway  are  used  for  gateways.  See  Gateways,  below,  for  more
       information.

     Implementation Details

       These  concepts  are  details of how OVN is implemented internally. They might still be of
       interest to users and administrators.

       Logical datapaths are an implementation detail of logical networks in the  OVN  southbound
       database.  ovn-northd  translates each logical switch or router in the northbound database
       into a logical datapath in the southbound database Datapath_Binding table.

       For the most part, ovn-northd  also  translates  each  logical  switch  port  in  the  OVN
       northbound  database  into  a  record  in  the southbound database Port_Binding table. The
       latter table corresponds roughly to  the  northbound  Logical_Switch_Port  table.  It  has
       multiple  types  of  logical  port  bindings,  of  which many types correspond directly to
       northbound LSP types. LSP types handled this way include  VIF  (empty  string),  localnet,
       localport, vtep, and l2gateway.

       The  Port_Binding  table has some types of port binding that do not correspond directly to
       logical switch port types. The common is patch  port  bindings,  known  as  logical  patch
       ports.  These port bindings always occur in pairs, and a packet that enters on either side
       comes out on the other. ovn-northd connects logical switches and logical routers  together
       using logical patch ports.

       Port  bindings  with  types  vtep,  l2gateway, l3gateway, and chassisredirect are used for
       gateways. These are explained in Gateways, below.

   Gateways
       Gateways provide limited connectivity between logical networks and physical ones. They can
       also  provide  connectivity  between different OVN deployments. This section will focus on
       the former, and the latter will  be  described  in  details  in  section  OVN  Deployments
       Interconnection.

       OVN support multiple kinds of gateways.

     VTEP Gateways

       A  ``VTEP gateway’’ connects an OVN logical network to a physical (or virtual) switch that
       implements the OVSDB VTEP schema that accompanies Open vSwitch. (The ``VTEP gateway’’ term
       is  a misnomer, since a VTEP is just a VXLAN Tunnel Endpoint, but it is a well established
       name.) See Life Cycle of a VTEP gateway, below, for more information.

       The main intended use case for VTEP gateways is to  attach  physical  servers  to  an  OVN
       logical network using a physical top-of-rack switch that supports the OVSDB VTEP schema.

     L2 Gateways

       A L2 gateway simply attaches a designated physical L2 segment available on some chassis to
       a logical network. The physical network effectively becomes part of the logical network.

       To set up a L2 gateway, the CMS adds an l2gateway LSP to an  appropriate  logical  switch,
       setting  LSP  options  to  name the chassis on which it should be bound. ovn-northd copies
       this configuration into a southbound  Port_Binding  record.  On  the  designated  chassis,
       ovn-controller forwards packets appropriately to and from the physical segment.

       L2  gateway  ports  have  features in common with localnet ports. However, with a localnet
       port, the physical network becomes the transport between hypervisors. With an L2  gateway,
       packets  are  still transported between hypervisors over tunnels and the l2gateway port is
       only used for the packets that are  on  the  physical  network.  The  application  for  L2
       gateways  is  similar to that for VTEP gateways, e.g. to add non-virtualized machines to a
       logical network, but L2 gateways do not require special support from top-of-rack  hardware
       switches.

     L3 Gateway Routers

       As  described  above under Logical Networks, ordinary OVN logical routers are distributed:
       they are not implemented in a single place but rather in every hypervisor chassis. This is
       a  problem  for stateful services such as SNAT and DNAT, which need to be implemented in a
       centralized manner.

       To allow for this kind of functionality, OVN supports L3 gateway routers,  which  are  OVN
       logical  routers  that  are  implemented  in  a  designated  chassis.  Gateway routers are
       typically used between distributed logical routers and physical networks. The  distributed
       logical  router  and  the  logical switches behind it, to which VMs and containers attach,
       effectively reside on each hypervisor. The distributed router and the gateway  router  are
       connected  by  another logical switch, sometimes referred to as a ``join’’ logical switch.
       (OVN logical routers may be connected to one  another  directly,  without  an  intervening
       switch,  but  the  OVN  implementation  only  supports  gateway  logical  routers that are
       connected to logical switches. Using a join logical switch also reduces the number  of  IP
       addresses  needed  on  the  distributed  router.)  On  the  other side, the gateway router
       connects to another logical switch that has a localnet port  connecting  to  the  physical
       network.

       The  following  diagram  shows a typical situation. One or more logical switches LS1, ...,
       LSn connect to distributed logical router LR1, which in turn connects  through  LSjoin  to
       gateway  logical router GLR, which also connects to logical switch LSlocal, which includes
       a localnet port to attach to the physical network.

                                       LSlocal
                                          |
                                         GLR
                                          |
                                       LSjoin
                                          |
                                         LR1
                                          |
                                     +----+----+
                                     |    |    |
                                    LS1  ...  LSn

       To configure an L3 gateway router, the CMS sets options:chassis in the router’s northbound
       Logical_Router  to  the  chassis’s  name. In response, ovn-northd uses a special l3gateway
       port binding (instead of a patch binding)  in  the  southbound  database  to  connect  the
       logical  router  to  its  neighbors.  In turn, ovn-controller tunnels packets to this port
       binding to the designated L3 gateway chassis, instead of processing them locally.

       DNAT and SNAT rules may be associated with a gateway  router,  which  provides  a  central
       location  that  can  handle  one-to-many  SNAT  (aka IP masquerading). Distributed gateway
       ports, described below, also support NAT.

     Distributed Gateway Ports

       A distributed gateway port is a logical  router  port  that  is  specially  configured  to
       designate   one  distinguished  chassis,  called  the  gateway  chassis,  for  centralized
       processing. A distributed gateway port should connect to a logical switch that has an  LSP
       that  connects  externally,  that is, either a localnet LSP or a connection to another OVN
       deployment (see OVN Deployments Interconnection). Packets that  traverse  the  distributed
       gateway  port  are  processed  without involving the gateway chassis when they can be, but
       when needed they do take an extra hop through it.

       The following diagram illustrates the use of a  distributed  gateway  port.  A  number  of
       logical  switches  LS1,  ..., LSn connect to distributed logical router LR1, which in turn
       connects through the distributed gateway port to logical switch LSlocal  that  includes  a
       localnet port to attach to the physical network.

                                       LSlocal
                                          |
                                         LR1
                                          |
                                     +----+----+
                                     |    |    |
                                    LS1  ...  LSn

       ovn-northd  creates two southbound Port_Binding records to represent a distributed gateway
       port, instead of the usual one. One of these is a patch port binding named  for  the  LRP,
       which  is  used  for  as much traffic as it can. The other one is a port binding with type
       chassisredirect, named cr-port. The chassisredirect port binding has one specialized  job:
       when  a  packet  is  output  to it, the flow table causes it to be tunneled to the gateway
       chassis, at which point it is automatically output to the patch port  binding.  Thus,  the
       flow  table can output to this port binding in cases where a particular task has to happen
       on the gateway chassis. The chassisredirect  port  binding  is  not  otherwise  used  (for
       example, it never receives packets).

       The  CMS  may  configure  distributed  gateway ports three different ways. See Distributed
       Gateway Ports in the documentation for Logical_Router_Port in ovn-nb(5) for details.

       Distributed gateway ports support  high  availability.  When  more  than  one  chassis  is
       specified,  OVN  only  uses  one at a time as the gateway chassis. OVN uses BFD to monitor
       gateway connectivity, preferring the highest-priority gateway that is online.

       A logical router can have multiple distributed gateway ports,  each  connecting  different
       external  networks. Load balancing is not yet supported for logical routers with more than
       one distributed gateway port configured.

       Physical VLAN MTU Issues

       Consider the preceding diagram again:

                                       LSlocal
                                          |
                                         LR1
                                          |
                                     +----+----+
                                     |    |    |
                                    LS1  ...  LSn

       Suppose that each logical switch LS1, ...,  LSn  is  bridged  to  a  physical  VLAN-tagged
       network attached to a localnet port on LSlocal, over a distributed gateway port on LR1. If
       a packet originating on LSi is destined to the external  network,  OVN  sends  it  to  the
       gateway  chassis over a tunnel. There, the packet traverses LR1’s logical router pipeline,
       possibly undergoes NAT, and eventually ends up at LSlocal’s localnet port. If all  of  the
       physical links in the network have the same MTU, then the packet’s transit across a tunnel
       causes an MTU problem: tunnel overhead prevents a packet that uses the full  physical  MTU
       from crossing the tunnel to the gateway chassis (without fragmentation).

       OVN offers two solutions to this problem, the reside-on-redirect-chassis and redirect-type
       options. Both solutions require each logical switch LS1, ..., LSn to  include  a  localnet
       logical  switch  port  LN1,  ...,  LNn respectively, that is present on each chassis. Both
       cause packets to be sent over the localnet ports instead of tunnels. They differ in  which
       packets-some  or  all-are sent this way. The most prominent tradeoff between these options
       is that reside-on-redirect-chassis is easier to configure and that redirect-type  performs
       better for east-west traffic.

       The  first  solution  is  the  reside-on-redirect-chassis option for logical router ports.
       Setting this option on a LRP from (e.g.) LS1 to LR1 disables forwarding from  LS1  to  LR1
       except  on  the  gateway  chassis.  On chassis other than the gateway chassis, this single
       change means that packets that would otherwise have been  forwarded  to  LR1  are  instead
       forwarded  to LN1. The instance of LN1 on the gateway chassis then receives the packet and
       forwards it to LR1. The  packet  traverses  the  LR1  logical  router  pipeline,  possibly
       undergoes  NAT,  and  eventually  ends  up  at  LSlocal’s  localnet port. The packet never
       traverses a tunnel, avoiding the MTU issue.

       This option has the further consequence of  centralizing  ``distributed’’  logical  router
       LR1,  since no packets are forwarded from LS1 to LR1 on any chassis other than the gateway
       chassis. Therefore, east-west traffic passes through the gateway chassis, not just  north-
       south.  (The  naive ``fix’’ of allowing east-west traffic to flow directly between chassis
       over LN1 does not work because routing sets the Ethernet source address  to  LR1’s  source
       address. Seeing this single Ethernet source address originate from all of the chassis will
       confuse the physical switch.)

       Do not set the reside-on-redirect-chassis option on a distributed  gateway  port.  In  the
       diagram above, it would be set on the LRPs connecting LS1, ..., LSn to LR1.

       The  second  solution  is  the redirect-type option for distributed gateway ports. Setting
       this option to bridged causes packets that are redirected to the  gateway  chassis  to  go
       over  the  localnet  ports  instead of being tunneled. This option does not change how OVN
       treats packets not redirected to the gateway chassis.

       The redirect-type  option  requires  the  administrator  or  the  CMS  to  configure  each
       participating  chassis  with  a  unique Ethernet address for the logical router by setting
       ovn-chassis-mac-mappings in the Open vSwitch database, for  use  by  ovn-controller.  This
       makes it more difficult to configure than reside-on-redirect-chassis.

       Set the redirect-type option on a distributed gateway port.

       Using Distributed Gateway Ports For Scalability

       Although  the  primary  goal  of  distributed  gateway ports is to provide connectivity to
       external networks, there is a special use case for scalability.

       In some deployments, such as the ones using ovn-kubernetes, logical switches are bound  to
       individual  chassises,  and  are  connected  by  a  distributed  logical  router.  In such
       deployments, the chassis level logical switches are centralized on the chassis instead  of
       distributed,  which means the ovn-controller on each chassis doesn’t need to process flows
       and ports of logical switches on other chassises.  However,  without  any  specific  hint,
       ovn-controller  would  still  process  all  the  logical  switches  as  if  they are fully
       distributed. In this case, distributed gateway port can be very useful. The chassis  level
       logical  switches  can  be  connected  to the distributed router using distributed gateway
       ports, by setting the gateway chassis (or HA chassis groups with only a single chassis  in
       it)  to  the  chassis that each logical switch is bound to. ovn-controller would then skip
       processing the logical  switches  on  all  the  other  chassises,  largely  improving  the
       scalability, especially when there are a big number of chassises.

   Life Cycle of a VIF
       Tables  and  their  schemas  presented in isolation are difficult to understand. Here’s an
       example.

       A VIF on a hypervisor is a virtual  network  interface  attached  either  to  a  VM  or  a
       container  running  directly on that hypervisor (This is different from the interface of a
       container running inside a VM).

       The steps in this example refer often to details of the OVN and  OVN  Northbound  database
       schemas.  Please  see  ovn-sb(5)  and ovn-nb(5), respectively, for the full story on these
       databases.

              1.  A VIF’s life cycle begins when a CMS administrator creates a new VIF using  the
                  CMS  user interface or API and adds it to a switch (one implemented by OVN as a
                  logical  switch).  The  CMS  updates  its  own  configuration.  This   includes
                  associating  unique, persistent identifier vif-id and Ethernet address mac with
                  the VIF.

              2.  The CMS plugin updates the OVN Northbound database to include the new  VIF,  by
                  adding  a row to the Logical_Switch_Port table. In the new row, name is vif-id,
                  mac is mac, switch points to the OVN logical  switch’s  Logical_Switch  record,
                  and other columns are initialized appropriately.

              3.  ovn-northd  receives  the OVN Northbound database update. In turn, it makes the
                  corresponding updates to the OVN Southbound database, by adding rows to the OVN
                  Southbound database Logical_Flow table to reflect the new port, e.g. add a flow
                  to recognize that packets destined to the new  port’s  MAC  address  should  be
                  delivered  to  it,  and  update  the flow that delivers broadcast and multicast
                  packets to include the new port. It also creates a record in the Binding  table
                  and populates all its columns except the column that identifies the chassis.

              4.  On  every  hypervisor,  ovn-controller  receives the Logical_Flow table updates
                  that ovn-northd made in the previous step. As long as the VM that owns the  VIF
                  is  powered off, ovn-controller cannot do much; it cannot, for example, arrange
                  to send packets to or receive packets from the VIF, because the  VIF  does  not
                  actually exist anywhere.

              5.  Eventually,  a user powers on the VM that owns the VIF. On the hypervisor where
                  the VM is powered on, the integration between the hypervisor and  Open  vSwitch
                  (described  in  Documentation/topics/integration.rst in the Open vSwitch source
                  tree) adds the  VIF  to  the  OVN  integration  bridge  and  stores  vif-id  in
                  external_ids:iface-id to indicate that the interface is an instantiation of the
                  new VIF. (None of this code is new in OVN;  this  is  pre-existing  integration
                  work that has already been done on hypervisors that support OVS.)

              6.  On   the  hypervisor  where  the  VM  is  powered  on,  ovn-controller  notices
                  external_ids:iface-id in the new Interface. In response, in the OVN  Southbound
                  DB,  it  updates  the Binding table’s chassis column for the row that links the
                  logical  port  from  external_ids:  iface-id  to  the  hypervisor.   Afterward,
                  ovn-controller  updates  the local hypervisor’s OpenFlow tables so that packets
                  to and from the VIF are properly handled.

              7.  Some CMS  systems,  including  OpenStack,  fully  start  a  VM  only  when  its
                  networking  is  ready.  To  support this, ovn-northd notices the chassis column
                  updated for the row in Binding table and pushes this upward by updating the  up
                  column  in  the OVN Northbound database’s Logical_Switch_Port table to indicate
                  that the VIF is now up. The CMS, if it uses this feature,  can  then  react  by
                  allowing the VM’s execution to proceed.

              8.  On  every  hypervisor but the one where the VIF resides, ovn-controller notices
                  the completely populated row in the Binding table. This provides ovn-controller
                  the  physical  location  of  the  logical  port,  so  each instance updates the
                  OpenFlow tables of its switch (based on logical datapath flows in  the  OVN  DB
                  Logical_Flow table) so that packets to and from the VIF can be properly handled
                  via tunnels.

              9.  Eventually, a user powers off the VM that owns the VIF. On the hypervisor where
                  the VM was powered off, the VIF is deleted from the OVN integration bridge.

              10. On the hypervisor where the VM was powered off, ovn-controller notices that the
                  VIF was deleted. In response, it removes the  Chassis  column  content  in  the
                  Binding table for the logical port.

              11. On  every  hypervisor,  ovn-controller  notices the empty Chassis column in the
                  Binding table’s row for the logical port. This  means  that  ovn-controller  no
                  longer  knows  the  physical  location  of  the  logical port, so each instance
                  updates its OpenFlow table to reflect that.

              12. Eventually, when the VIF (or its entire VM) is no longer needed by  anyone,  an
                  administrator  deletes  the  VIF  using  the CMS user interface or API. The CMS
                  updates its own configuration.

              13. The CMS plugin removes the VIF from the OVN Northbound  database,  by  deleting
                  its row in the Logical_Switch_Port table.

              14. ovn-northd  receives  the  OVN  Northbound  update  and in turn updates the OVN
                  Southbound database accordingly, by removing or updating the rows from the  OVN
                  Southbound  database  Logical_Flow table and Binding table that were related to
                  the now-destroyed VIF.

              15. On every hypervisor, ovn-controller receives  the  Logical_Flow  table  updates
                  that  ovn-northd  made  in  the  previous step. ovn-controller updates OpenFlow
                  tables to reflect the update, although there may not be much to do,  since  the
                  VIF  had  already become unreachable when it was removed from the Binding table
                  in a previous step.

   Life Cycle of a Container Interface Inside a VM
       OVN provides virtual network abstractions by  converting  information  written  in  OVN_NB
       database to OpenFlow flows in each hypervisor. Secure virtual networking for multi-tenants
       can only be provided if OVN controller is the only entity that can modify  flows  in  Open
       vSwitch.  When the Open vSwitch integration bridge resides in the hypervisor, it is a fair
       assumption to make that tenant workloads running inside VMs cannot  make  any  changes  to
       Open vSwitch flows.

       If  the infrastructure provider trusts the applications inside the containers not to break
       out and modify the Open vSwitch flows, then containers can be run in hypervisors. This  is
       also  the  case when containers are run inside the VMs and Open vSwitch integration bridge
       with flows added by OVN controller resides in the same VM. For both the above  cases,  the
       workflow  is the same as explained with an example in the previous section ("Life Cycle of
       a VIF").

       This section talks about the life cycle of a container interface (CIF) when containers are
       created  in the VMs and the Open vSwitch integration bridge resides inside the hypervisor.
       In this case, even if a container application breaks out, other tenants are  not  affected
       because  the containers running inside the VMs cannot modify the flows in the Open vSwitch
       integration bridge.

       When multiple containers are created inside a VM, there are multiple CIFs associated  with
       them.  The  network  traffic  associated  with  these  CIFs need to reach the Open vSwitch
       integration  bridge  running  in  the  hypervisor  for  OVN  to  support  virtual  network
       abstractions. OVN should also be able to distinguish network traffic coming from different
       CIFs. There are two ways to distinguish network traffic of CIFs.

       One way is to provide one VIF for every CIF (1:1 model). This means that there could be  a
       lot  of  network  devices  in  the hypervisor. This would slow down OVS because of all the
       additional CPU cycles needed for the management of all the VIFs. It would also  mean  that
       the entity creating the containers in a VM should also be able to create the corresponding
       VIFs in the hypervisor.

       The second way is to provide a single VIF for all the CIFs (1:many model). OVN could  then
       distinguish  network traffic coming from different CIFs via a tag written in every packet.
       OVN uses this mechanism and uses VLAN as the tagging mechanism.

              1.  A CIF’s life cycle begins when a container is spawned inside a VM by the either
                  the  same  CMS  that  created  the  VM  or a tenant that owns that VM or even a
                  container Orchestration System that is different than the  CMS  that  initially
                  created  the VM. Whoever the entity is, it will need to know the vif-id that is
                  associated with the network interface of the VM  through  which  the  container
                  interface’s  network traffic is expected to go through. The entity that creates
                  the container interface will also need to choose an unused VLAN inside that VM.

              2.  The container spawning entity (either directly or through the CMS that  manages
                  the  underlying  infrastructure) updates the OVN Northbound database to include
                  the new CIF, by adding a row to the Logical_Switch_Port table. In the new  row,
                  name  is  any  unique  identifier,  parent_name is the vif-id of the VM through
                  which the CIF’s network traffic is expected to go through and the  tag  is  the
                  VLAN tag that identifies the network traffic of that CIF.

              3.  ovn-northd  receives  the OVN Northbound database update. In turn, it makes the
                  corresponding updates to the OVN Southbound database, by adding rows to the OVN
                  Southbound  database’s  Logical_Flow  table to reflect the new port and also by
                  creating a new row in the Binding table and populating all its  columns  except
                  the column that identifies the chassis.

              4.  On  every  hypervisor,  ovn-controller subscribes to the changes in the Binding
                  table. When a new row is  created  by  ovn-northd  that  includes  a  value  in
                  parent_port column of Binding table, the ovn-controller in the hypervisor whose
                  OVN integration bridge has that same value in vif-id  in  external_ids:iface-id
                  updates  the local hypervisor’s OpenFlow tables so that packets to and from the
                  VIF with the particular VLAN tag are properly handled. Afterward it updates the
                  chassis column of the Binding to reflect the physical location.

              5.  One  can  only  start the application inside the container after the underlying
                  network is ready. To support  this,  ovn-northd  notices  the  updated  chassis
                  column  in  Binding  table  and  updates  the  up  column in the OVN Northbound
                  database’s Logical_Switch_Port table to indicate that the CIF is  now  up.  The
                  entity  responsible  to  start the container application queries this value and
                  starts the application.

              6.  Eventually the entity that created and started the  container,  stops  it.  The
                  entity,   through   the   CMS   (or   directly)   deletes   its   row   in  the
                  Logical_Switch_Port table.

              7.  ovn-northd receives the OVN Northbound update  and  in  turn  updates  the  OVN
                  Southbound  database accordingly, by removing or updating the rows from the OVN
                  Southbound database Logical_Flow table that were related to  the  now-destroyed
                  CIF. It also deletes the row in the Binding table for that CIF.

              8.  On  every  hypervisor,  ovn-controller  receives the Logical_Flow table updates
                  that ovn-northd made in the  previous  step.  ovn-controller  updates  OpenFlow
                  tables to reflect the update.

   Architectural Physical Life Cycle of a Packet
       This  section  describes  how  a  packet  travels from one virtual machine or container to
       another through OVN. This description focuses on the physical treatment of a packet; for a
       description  of the logical life cycle of a packet, please refer to the Logical_Flow table
       in ovn-sb(5).

       This section mentions several data and metadata fields, for clarity summarized here:

              tunnel key
                     When OVN encapsulates a packet in Geneve  or  another  tunnel,  it  attaches
                     extra  data  to  it  to  allow  the  receiving  OVN  instance  to process it
                     correctly.  This  takes  different  forms  depending   on   the   particular
                     encapsulation,  but  in each case we refer to it here as the ``tunnel key.’’
                     See Tunnel Encapsulations, below, for details.

              logical datapath field
                     A field that denotes the logical datapath through which a  packet  is  being
                     processed.  OVN  uses  the field that OpenFlow 1.1+ simply (and confusingly)
                     calls ``metadata’’ to store the logical  datapath.  (This  field  is  passed
                     across tunnels as part of the tunnel key.)

              logical input port field
                     A  field  that  denotes  the  logical port from which the packet entered the
                     logical datapath. OVN stores this in Open vSwitch extension register  number
                     14.

                     Geneve  and  STT  tunnels  pass  this  field as part of the tunnel key. Ramp
                     switch VXLAN tunnels do not explicitly carry a logical input port, but since
                     they  are  used  to  communicate  with  gateways that from OVN’s perspective
                     consist of only a single logical port, so that OVN can set the logical input
                     port  field  to  this  one  on  ingress  to the OVN logical pipeline. As for
                     regular VXLAN tunnels, they don’t carry input port field at all.  This  puts
                     additional  limitations on cluster capabilities that are described in Tunnel
                     Encapsulations section.

              logical output port field
                     A field that denotes the logical port from which the packet will  leave  the
                     logical  datapath.  This is initialized to 0 at the beginning of the logical
                     ingress pipeline. OVN stores this in Open vSwitch extension register  number
                     15.

                     Geneve,  STT and regular VXLAN tunnels pass this field as part of the tunnel
                     key. Ramp switch VXLAN tunnels do  not  transmit  the  logical  output  port
                     field, and since they do not carry a logical output port field in the tunnel
                     key, when a packet is received from ramp  switch  VXLAN  tunnel  by  an  OVN
                     hypervisor,  the  packet  is  resubmitted to table 8 to determine the output
                     port(s); when the packet reaches table 39, these packets are resubmitted  to
                     table  40  for local delivery by checking a MLF_RCV_FROM_RAMP flag, which is
                     set when the packet arrives from a ramp tunnel.

              conntrack zone field for logical ports
                     A field that denotes the connection tracking zone  for  logical  ports.  The
                     value  only  has  local  significance and is not meaningful between chassis.
                     This is initialized to 0 at the beginning of the logical  ingress  pipeline.
                     OVN  stores this in the lower 16 bits of the Open vSwitch extension register
                     number 13.

              conntrack zone fields for routers
                     Fields that denote the connection tracking zones for routers.  These  values
                     only  have  local  significance  and are not meaningful between chassis. OVN
                     stores the zone information for north to south traffic (for DNATting or ECMP
                     symmetric  replies)  in  Open  vSwitch extension register number 11 and zone
                     information for south  to  north  traffic  (for  SNATing)  in  Open  vSwitch
                     extension register number 12.

              Encap ID for logical ports
                     A  field  that records an ID that indicates which encapsulation IP should be
                     used when sending packets to a remote chassis,  according  to  the  original
                     input logical port. This is useful when there are multiple IPs available for
                     encapsulation. The value only has local significance and is  not  meaningful
                     between  chassis.  This  is initialized to 0 at the beginning of the logical
                     ingress pipeline. OVN stores this in the higher 16 bits of the Open  vSwitch
                     extension register number 13.

              logical flow flags
                     The  logical  flags are intended to handle keeping context between tables in
                     order to decide which rules in subsequent tables are matched.  These  values
                     only  have  local  significance  and are not meaningful between chassis. OVN
                     stores the logical flags in Open vSwitch extension register number 10.

              VLAN ID
                     The VLAN ID is used as an interface between OVN and containers nested inside
                     a  VM  (see Life Cycle of a container interface inside a VM, above, for more
                     information).

       Initially, a VM or container on the ingress hypervisor sends a packet on a  port  attached
       to the OVN integration bridge. Then:

              1.  OpenFlow  table  0  performs  physical-to-logical  translation.  It matches the
                  packet’s ingress port. Its actions annotate the packet with  logical  metadata,
                  by setting the logical datapath field to identify the logical datapath that the
                  packet is traversing and the logical input port field to identify  the  ingress
                  port. Then it resubmits to table 8 to enter the logical ingress pipeline.

                  Packets  that  originate  from  a container nested within a VM are treated in a
                  slightly different way. The originating container can be distinguished based on
                  the   VIF-specific  VLAN  ID,  so  the  physical-to-logical  translation  flows
                  additionally match on VLAN ID and the actions strip the VLAN header.  Following
                  this step, OVN treats packets from containers just like any other packets.

                  Table 0 also processes packets that arrive from other chassis. It distinguishes
                  them from other packets by ingress port, which is a  tunnel.  As  with  packets
                  just entering the OVN pipeline, the actions annotate these packets with logical
                  datapath metadata. For tunnel types that support it, they  are  also  annotated
                  with  logical  ingress  port metadata. In addition, the actions set the logical
                  output port field, which is available because in OVN tunneling occurs after the
                  logical output port is known. These pieces of information are obtained from the
                  tunnel encapsulation metadata (see Tunnel Encapsulations for encoding details).
                  Then the actions resubmit to table 38 to enter the logical egress pipeline.

              2.  OpenFlow  tables  8  through  31  execute the logical ingress pipeline from the
                  Logical_Flow table in the OVN Southbound database. These tables  are  expressed
                  entirely in terms of logical concepts like logical ports and logical datapaths.
                  A big part of  ovn-controller’s  job  is  to  translate  them  into  equivalent
                  OpenFlow  (in particular it translates the table numbers: Logical_Flow tables 0
                  through 23 become OpenFlow tables 8 through 31).

                  Each logical flow maps  to  one  or  more  OpenFlow  flows.  An  actual  packet
                  ordinarily  matches only one of these, although in some cases it can match more
                  than one of these flows (which is not a problem because all of  them  have  the
                  same actions). ovn-controller uses the first 32 bits of the logical flow’s UUID
                  as the cookie for its OpenFlow flow or flows. (This is not necessarily  unique,
                  since the first 32 bits of a logical flow’s UUID is not necessarily unique.)

                  Some  logical flows can map to the Open vSwitch ``conjunctive match’’ extension
                  (see ovs-fields(7)). Flows with a conjunction action use an OpenFlow cookie  of
                  0, because they can correspond to multiple logical flows. The OpenFlow flow for
                  a conjunctive match includes a match on conj_id.

                  Some logical flows may not be represented in the OpenFlow  tables  on  a  given
                  hypervisor,  if  they  could not be used on that hypervisor. For example, if no
                  VIF in a logical switch resides on a given hypervisor, and the  logical  switch
                  is  not  otherwise  reachable  on  that  hypervisor (e.g. over a series of hops
                  through logical switches and routers starting from a VIF  on  the  hypervisor),
                  then the logical flow may not be represented there.

                  Most  OVN  actions  have  fairly  obvious implementations in OpenFlow (with OVS
                  extensions), e.g. next; is  implemented  as  resubmit,  field  =  constant;  as
                  set_field. A few are worth describing in more detail:

                  output:
                         Implemented  by  resubmitting  the  packet  to table 37. If the pipeline
                         executes more than one  output  action,  then  each  one  is  separately
                         resubmitted to table 37. This can be used to send multiple copies of the
                         packet to multiple ports. (If the packet was not  modified  between  the
                         output  actions,  and  some  of  the  copies  are  destined  to the same
                         hypervisor, then using  a  logical  multicast  output  port  would  save
                         bandwidth between hypervisors.)

                  get_arp(P, A);
                  get_nd(P, A);
                       Implemented  by  storing arguments into OpenFlow fields, then resubmitting
                       to table 66, which ovn-controller populates with flows generated from  the
                       MAC_Binding  table  in the OVN Southbound database. If there is a match in
                       table 66, then its actions store the bound MAC in the Ethernet destination
                       address field.

                       (The  OpenFlow  actions  save and restore the OpenFlow fields used for the
                       arguments, so that the OVN actions  do  not  have  to  be  aware  of  this
                       temporary use.)

                  put_arp(P, A, E);
                  put_nd(P, A, E);
                       Implemented by storing the arguments into OpenFlow fields, then outputting
                       a packet to ovn-controller, which updates the MAC_Binding table.

                       (The OpenFlow actions save and restore the OpenFlow fields  used  for  the
                       arguments,  so  that  the  OVN  actions  do  not  have to be aware of this
                       temporary use.)

                  R = lookup_arp(P, A, M);
                  R = lookup_nd(P, A, M);
                       Implemented by storing arguments into OpenFlow fields,  then  resubmitting
                       to  table 67, which ovn-controller populates with flows generated from the
                       MAC_Binding table in the OVN Southbound database. If there is a  match  in
                       table 67, then its actions set the logical flow flag MLF_LOOKUP_MAC.

                       (The  OpenFlow  actions  save and restore the OpenFlow fields used for the
                       arguments, so that the OVN actions  do  not  have  to  be  aware  of  this
                       temporary use.)

              3.  OpenFlow  tables  37  through  41  implement  the  output action in the logical
                  ingress pipeline. Specifically, table 37 serves as an  entry  point  to  egress
                  pipeline.  Table  37  detects  IP  packets that are too big for a corresponding
                  interface. Table 38 produces ICMPv4 Fragmentation Needed (or  ICMPv6  Too  Big)
                  errors and deliver them back to the offending port. table 39 handles packets to
                  remote hypervisors, table 40 handles packets to the local hypervisor, and table
                  41  checks  whether  packets whose logical ingress and egress port are the same
                  should be discarded.

                  Logical patch ports are a special case. Logical  patch  ports  do  not  have  a
                  physical  location and effectively reside on every hypervisor. Thus, flow table
                  40, for output to ports on the local hypervisor, naturally implements output to
                  unicast  logical patch ports too. However, applying the same logic to a logical
                  patch port that is part of a logical multicast group yields packet duplication,
                  because  each  hypervisor  that  contains a logical port in the multicast group
                  will also output the packet to the logical patch port. Thus,  multicast  groups
                  implement output to logical patch ports in table 39.

                  Each flow in table 39 matches on a logical output port for unicast or multicast
                  logical ports that include a logical port on a remote hypervisor.  Each  flow’s
                  actions  implement sending a packet to the port it matches. For unicast logical
                  output ports on remote hypervisors, the actions  set  the  tunnel  key  to  the
                  correct  value,  then  send  the  packet  on  the  tunnel  port  to the correct
                  hypervisor. (When the remote hypervisor receives the packet, table 0 there will
                  recognize it as a tunneled packet and pass it along to table 40.) For multicast
                  logical output ports, the actions send one copy of the packet  to  each  remote
                  hypervisor,  in  the same way as for unicast destinations. If a multicast group
                  includes a logical port or ports on the local hypervisor, then its actions also
                  resubmit to table 40. Table 39 also includes:

                  •      A  higher-priority  rule  to  match  packets  received  from ramp switch
                         tunnels, based on flag MLF_RCV_FROM_RAMP, and resubmit these packets  to
                         table  40  for local delivery. Packets received from ramp switch tunnels
                         reach here because of a lack of logical output port field in the  tunnel
                         key  and  thus  these  packets  needed  to  be  submitted  to table 8 to
                         determine the output port.

                  •      A higher-priority rule to match packets  received  from  ports  of  type
                         localport,  based  on the logical input port, and resubmit these packets
                         to table 40 for local delivery. Ports of type localport exist  on  every
                         hypervisor and by definition their traffic should never go out through a
                         tunnel.

                  •      A higher-priority rule to match packets  that  have  the  MLF_LOCAL_ONLY
                         logical  flow  flag  set,  and whose destination is a multicast address.
                         This flag indicates that the packet should not be  delivered  to  remote
                         hypervisors,  even if the multicast destination includes ports on remote
                         hypervisors. This flag is used when ovn-controller is the originator  of
                         the  multicast packet. Since each ovn-controller instance is originating
                         these packets, the packets only need to be delivered to local ports.

                  •      A fallback flow that resubmits to table 40 if there is no other match.

                  Flows in table 40 resemble those in table 39 but for logical ports that  reside
                  locally  rather  than  remotely.  For unicast logical output ports on the local
                  hypervisor, the actions just resubmit to table 41. For multicast  output  ports
                  that  include  one or more logical ports on the local hypervisor, for each such
                  logical port P, the actions change the logical output port to P, then  resubmit
                  to table 41.

                  A special case is that when a localnet port exists on the datapath, remote port
                  is connected by switching to the localnet port. In this case, instead of adding
                  a  flow  in  table  39 to reach the remote port, a flow is added in table 40 to
                  switch the logical outport to the localnet port, and resubmit to table 40 as if
                  it were unicasted to a logical port on the local hypervisor.

                  Table 41 matches and drops packets for which the logical input and output ports
                  are the same and  the  MLF_ALLOW_LOOPBACK  flag  is  not  set.  It  also  drops
                  MLF_LOCAL_ONLY  packets directed to a localnet port. It resubmits other packets
                  to table 42.

              4.  OpenFlow tables 42 through 62 execute the  logical  egress  pipeline  from  the
                  Logical_Flow  table  in  the  OVN  Southbound database. The egress pipeline can
                  perform a final stage of validation before packet delivery. Eventually, it  may
                  execute  an  output  action, which ovn-controller implements by resubmitting to
                  table 64. A packet for which the pipeline never executes output is  effectively
                  dropped  (although  it  may  have  been  transmitted  through a tunnel across a
                  physical network).

                  The egress pipeline cannot change the logical  output  port  or  cause  further
                  tunneling.

              5.  Table  64  bypasses  OpenFlow  loopback when MLF_ALLOW_LOOPBACK is set. Logical
                  loopback was handled in  table  41,  but  OpenFlow  by  default  also  prevents
                  loopback  to  the  OpenFlow ingress port. Thus, when MLF_ALLOW_LOOPBACK is set,
                  OpenFlow table 64 saves the OpenFlow ingress port, sets it to  zero,  resubmits
                  to  table  65  for  logical-to-physical  transformation,  and then restores the
                  OpenFlow ingress port, effectively disabling OpenFlow loopback  prevents.  When
                  MLF_ALLOW_LOOPBACK is unset, table 64 flow simply resubmits to table 65.

              6.  OpenFlow  table  65  performs  logical-to-physical translation, the opposite of
                  table 0. It matches the packet’s logical egress port. Its  actions  output  the
                  packet  to the port attached to the OVN integration bridge that represents that
                  logical port. If the logical egress port is a container nested with a VM,  then
                  before sending the packet the actions push on a VLAN header with an appropriate
                  VLAN ID.

   Logical Routers and Logical Patch Ports
       Typically logical routers and logical patch ports do not  have  a  physical  location  and
       effectively  reside  on every hypervisor. This is the case for logical patch ports between
       logical routers and logical switches behind those logical routers, to which VMs (and VIFs)
       attach.

       Consider  a  packet  sent from one virtual machine or container to another VM or container
       that resides on a different subnet. The packet will traverse tables 0 to 65  as  described
       in  the  previous section Architectural Physical Life Cycle of a Packet, using the logical
       datapath representing the logical switch that the sender is attached to. At table 39,  the
       packet  will  use  the  fallback  flow  that  resubmits  locally  to  table 40 on the same
       hypervisor. In this case, all of the processing from table 0 to table  65  occurs  on  the
       hypervisor where the sender resides.

       When  the  packet  reaches  table  65,  the  logical  egress port is a logical patch port.
       ovn-controller  implements  output  to  the  logical  patch  is  packet  by  cloning   and
       resubmitting  directly  to  the first OpenFlow flow table in the ingress pipeline, setting
       the logical ingress port to the peer logical patch port, and using the peer logical  patch
       port’s logical datapath (that represents the logical router).

       The  packet re-enters the ingress pipeline in order to traverse tables 8 to 65 again, this
       time using the logical datapath representing the logical router. The processing  continues
       as  described  in the previous section Architectural Physical Life Cycle of a Packet. When
       the packet reaches table 65, the logical egress port will once again be  a  logical  patch
       port. In the same manner as described above, this logical patch port will cause the packet
       to be resubmitted to OpenFlow tables 8  to  65,  this  time  using  the  logical  datapath
       representing the logical switch that the destination VM or container is attached to.

       The  packet  traverses  tables  8  to  65 a third and final time. If the destination VM or
       container resides on a remote hypervisor, then table 39 will send the packet on  a  tunnel
       port  from  the sender’s hypervisor to the remote hypervisor. Finally table 65 will output
       the packet directly to the destination VM or container.

       The following sections describe two exceptions, where logical routers and/or logical patch
       ports are associated with a physical location.

     Gateway Routers

       A  gateway  router is a logical router that is bound to a physical location. This includes
       all of the logical patch ports of the logical router, as well as all of the  peer  logical
       patch  ports on logical switches. In the OVN Southbound database, the Port_Binding entries
       for these logical patch ports use the type  l3gateway  rather  than  patch,  in  order  to
       distinguish that these logical patch ports are bound to a chassis.

       When  a hypervisor processes a packet on a logical datapath representing a logical switch,
       and the logical egress port is a l3gateway port representing  connectivity  to  a  gateway
       router, the packet will match a flow in table 39 that sends the packet on a tunnel port to
       the chassis where the gateway router resides. This processing in table 39 is done  in  the
       same manner as for VIFs.

     Distributed Gateway Ports

       This section provides additional details on distributed gateway ports, outlined earlier.

       The  primary  design  goal  of  distributed  gateway  ports is to allow as much traffic as
       possible to be handled locally on the hypervisor where a VM or container resides. Whenever
       possible,  packets  from  the  VM  or  container  to the outside world should be processed
       completely on that VM’s or container’s hypervisor, eventually traversing a  localnet  port
       instance  or  a  tunnel  to  the  physical network or a different OVN deployment. Whenever
       possible, packets from the outside world to a VM or container should be  directed  through
       the physical network directly to the VM’s or container’s hypervisor.

       In  order  to  allow  for the distributed processing of packets described in the paragraph
       above, distributed gateway ports need to be logical patch ports that effectively reside on
       every  hypervisor,  rather  than  l3gateway  ports that are bound to a particular chassis.
       However, the flows associated with distributed gateway ports often need to  be  associated
       with physical locations, for the following reasons:

              •      The physical network that the localnet port is attached to typically uses L2
                     learning. Any Ethernet address used over the distributed gateway  port  must
                     be  restricted to a single physical location so that upstream L2 learning is
                     not confused. Traffic sent out the  distributed  gateway  port  towards  the
                     localnet port with a specific Ethernet address must be sent out one specific
                     instance of the distributed gateway port on one  specific  chassis.  Traffic
                     received from the localnet port (or from a VIF on the same logical switch as
                     the localnet port) with a specific Ethernet address must be directed to  the
                     logical switch’s patch port instance on that specific chassis.

                     Due  to the implications of L2 learning, the Ethernet address and IP address
                     of the distributed gateway port need to be restricted to a  single  physical
                     location. For this reason, the user must specify one chassis associated with
                     the distributed gateway port. Note that traffic traversing  the  distributed
                     gateway  port  using other Ethernet addresses and IP addresses (e.g. one-to-
                     one NAT) is not restricted to this chassis.

                     Replies to ARP and ND requests must  be  restricted  to  a  single  physical
                     location, where the Ethernet address in the reply resides. This includes ARP
                     and ND replies for the IP address of the distributed gateway port, which are
                     restricted  to  the  chassis  that  the user associated with the distributed
                     gateway port.

              •      In order to support one-to-many SNAT (aka IP masquerading),  where  multiple
                     logical  IP  addresses spread across multiple chassis are mapped to a single
                     external IP address, it will be necessary to  handle  some  of  the  logical
                     router  processing  on a specific chassis in a centralized manner. Since the
                     SNAT external IP address  is  typically  the  distributed  gateway  port  IP
                     address,   and   for  simplicity,  the  same  chassis  associated  with  the
                     distributed gateway port is used.

       The details of flow restrictions to specific  chassis  are  described  in  the  ovn-northd
       documentation.

       While  most of the physical location dependent aspects of distributed gateway ports can be
       handled by restricting some  flows  to  specific  chassis,  one  additional  mechanism  is
       required.  When  a  packet  leaves the ingress pipeline and the logical egress port is the
       distributed gateway port, one of two different sets of actions is required at table 39:

              •      If the packet can be handled locally on the sender’s hypervisor  (e.g.  one-
                     to-one  NAT  traffic), then the packet should just be resubmitted locally to
                     table 40, in the normal manner for distributed logical patch ports.

              •      However, if the packet needs to be handled on the  chassis  associated  with
                     the  distributed  gateway  port  (e.g.  one-to-many  SNAT traffic or non-NAT
                     traffic), then table 39 must send the  packet  on  a  tunnel  port  to  that
                     chassis.

       In  order  to  trigger  the  second set of actions, the chassisredirect type of southbound
       Port_Binding has been added. Setting the logical egress port to the  type  chassisredirect
       logical  port  is  simply  a  way to indicate that although the packet is destined for the
       distributed gateway port, it needs to be redirected to a different chassis. At  table  39,
       packets with this logical egress port are sent to a specific chassis, in the same way that
       table 39 directs packets whose logical egress port is a VIF or a type  l3gateway  port  to
       different  chassis.  Once  the packet arrives at that chassis, table 40 resets the logical
       egress port to the value representing the distributed gateway port. For  each  distributed
       gateway  port,  there  is  one  type  chassisredirect port, in addition to the distributed
       logical patch port representing the distributed gateway port.

     High Availability for Distributed Gateway Ports

       OVN allows you to specify a prioritized list of chassis for a  distributed  gateway  port.
       This  is  done  by associating multiple Gateway_Chassis rows with a Logical_Router_Port in
       the OVN_Northbound database.

       When multiple chassis have been specified for a gateway, all chassis that may send packets
       to  that gateway will enable BFD on tunnels to all configured gateway chassis. The current
       master chassis for the gateway is the highest priority gateway chassis that  is  currently
       viewed as active based on BFD status.

       For    more   information   on   L3   gateway   high   availability,   please   refer   to
       http://docs.ovn.org/en/latest/topics/high-availability.html.

     Restrictions of Distributed Gateway Ports

       Distributed gateway ports are used to connect to an  external  network,  which  can  be  a
       physical  network  modeled  by  a  logical  switch with a localnet port, and can also be a
       logical  switch  that  interconnects  different  OVN  deployments  (see  OVN   Deployments
       Interconnection). Usually there can be many logical routers connected to the same external
       logical switch, as shown in below diagram.

                                     +--LS-EXT-+
                                     |    |    |
                                     |    |    |
                                    LR1  ...  LRn

       In this diagram, there are n logical routers connected to a logical  switch  LS-EXT,  each
       with  a  distributed gateway port, so that traffic sent to external world is redirected to
       the gateway chassis that is assigned to the distributed gateway port of respective logical
       router.

       In  the  logical  topology, nothing can prevent an user to add a route between the logical
       routers via the connected distributed gateway ports on LS-EXT. However,  the  route  works
       only  if  the  LS-EXT  is  a physical network (modeled by a logical switch with a localnet
       port). In that case the packet will be delivered between the gateway chassises through the
       localnet  port  via physical network. If the LS-EXT is a regular logical switch (backed by
       tunneling only, as in the use case of  OVN  interconnection),  then  the  packet  will  be
       dropped  on  the  source  gateway chassis. The limitation is due the fact that distributed
       gateway ports are tied to physical location, and without physical network  connection,  we
       will  end  up  with  either  dropping the packet or transferring it over the tunnels which
       could cause bigger problems  such  as  broadcast  packets  being  redirect  repeatedly  by
       different gateway chassises.

       With the limitation in mind, if a user do want the direct connectivity between the logical
       routers, it is better to create an  internal  logical  switch  connected  to  the  logical
       routers  with  regular  logical  router  ports,  which  are completely distributed and the
       packets don’t have to leave a chassis unless necessary, which is more optimal than routing
       via the distributed gateway ports.

     ARP request and ND NS packet processing

       Due  to  the  fact  that ARP requests and ND NA packets are usually broadcast packets, for
       performance reasons, OVN deals with requests that target OVN owned IP addresses (i.e.,  IP
       addresses  configured  on  the  router  ports,  VIPs,  NAT IPs) in a specific way and only
       forwards them to the logical router that owns the target  IP  address.  This  behavior  is
       different than that of traditional switches and implies that other routers/hosts connected
       to the logical switch will not learn the MAC/IP binding from the request packet.

       All other ARP and ND packets are flooded in the L2 broadcast domain and  to  all  attached
       logical patch ports.

     VIFs on the logical switch connected by a distributed gateway port

       Typically  the  logical  switch  connected  by  a distributed gateway port is for external
       connectivity, usually to a physical network through a localnet port on the logical switch,
       or  to a remote OVN deployment through OVN Interconnection. In these cases there is no VIF
       ports required on the logical switch.

       While not very common, it is still possible to create VIF  ports  on  the  logical  switch
       connected  by a distributed gateway port, but there is a limitation that the logical ports
       need to reside on the gateway chassis where the distributed gateway port  resides  to  get
       connectivity  to  other logical switches through the distributed gateway port. There is no
       limitation for the VIFs to connect within the logical switch, or beyond the logical switch
       through other regular distributed logical router ports.

       A  special  case  is  when  using  distributed  gateway  ports for scalability purpose, as
       mentioned earlier in this document. The logical switches connected by distributed  gateway
       ports  are  not  for connectivity but just for regular VIFs. However, the above limitation
       usually does not matter because in this use case all the VIFs on the  logical  switch  are
       located  on  the  same chassis with the distributed gateway port that connects the logical
       switch.

   Multiple localnet logical switches connected to a Logical Router
       It is possible to have multiple logical switches each with a localnet  port  (representing
       physical networks) connected to a logical router, in which one localnet logical switch may
       provide the external connectivity via a distributed gateway port and rest of the  localnet
       logical  switches  use  VLAN  tagging  in  the  physical  network.  It  is  expected  that
       ovn-bridge-mappings is configured appropriately on the  chassis  for  all  these  localnet
       networks.

     East West routing

       East-West routing between these localnet VLAN tagged logical switches work almost the same
       way as normal logical switches. When the VM sends such a packet, then:

              1.  It first enters the ingress pipeline, and then egress pipeline  of  the  source
                  localnet  logical  switch  datapath. It then enters the ingress pipeline of the
                  logical router datapath via the logical router port in the source chassis.

              2.  Routing decision is taken.

              3.  From the router datapath, packet enters the ingress pipeline  and  then  egress
                  pipeline  of  the  destination localnet logical switch datapath and goes out of
                  the integration bridge to the provider bridge ( belonging  to  the  destination
                  logical  switch)  via  the  localnet port. While sending the packet to provider
                  bridge, we also replace router port MAC as source MAC  with  a  chassis  unique
                  MAC.

                  This chassis unique MAC is configured as global ovs config on each chassis (eg.
                  via         "ovs-vsctl         set         open         .         external-ids:
                  ovn-chassis-mac-mappings="phys:aa:bb:cc:dd:ee:$i$i"").  For  more  details, see
                  ovn-controller(8).

                  If the above is not configured, then source MAC would be the router  port  MAC.
                  This  could  create  problem if we have more than one chassis. This is because,
                  since the router port is distributed, the same (MAC,VLAN) tuple  will  seen  by
                  physical network from other chassis as well, which could cause these issues:

                  •      Continuous MAC moves in top-of-rack switch (ToR).

                  •      ToR dropping the traffic, which is causing continuous MAC moves.

                  •      ToR blocking the ports from which MAC moves are happening.

              4.  The  destination chassis receives the packet via the localnet port and sends it
                  to the integration bridge. Before entering the integration  bridge  the  source
                  mac  of  the  packet  will  be  replaced with router port mac again. The packet
                  enters the ingress  pipeline  and  then  egress  pipeline  of  the  destination
                  localnet logical switch and finally gets delivered to the destination VM port.

     External traffic

       The following happens when a VM sends an external traffic (which requires NATting) and the
       chassis hosting the VM doesn’t have a distributed gateway port.

              1.  The packet first enters the ingress pipeline, and then egress pipeline  of  the
                  source localnet logical switch datapath. It then enters the ingress pipeline of
                  the logical router datapath via the logical router port in the source chassis.

              2.  Routing decision is taken. Since the gateway router or the distributed  gateway
                  port  doesn’t  reside  in  the source chassis, the traffic is redirected to the
                  gateway chassis via the tunnel port.

              3.  The gateway chassis receives the packet via the  tunnel  port  and  the  packet
                  enters  the  egress  pipeline  of  the  logical  router datapath. NAT rules are
                  applied here. The packet then enters  the  ingress  pipeline  and  then  egress
                  pipeline  of  the  localnet  logical  switch  datapath  which provides external
                  connectivity and finally goes out via the localnet port of the  logical  switch
                  which provides external connectivity.

       Although this works, the VM traffic is tunnelled when sent from the compute chassis to the
       gateway chassis. In order for it to  work  properly,  the  MTU  of  the  localnet  logical
       switches must be lowered to account for the tunnel encapsulation.

   Centralized routing for localnet VLAN tagged logical switches connected to a Logical Router
       To  overcome  the  tunnel  encapsulation  problem  described  in the previous section, OVN
       supports the option of enabling centralized  routing  for  localnet  VLAN  tagged  logical
       switches. CMS can configure the option options:reside-on-redirect-chassis to true for each
       Logical_Router_Port which connects to the localnet  VLAN  tagged  logical  switches.  This
       causes  the  gateway  chassis  (hosting  the  distributed  gateway port) to handle all the
       routing for these networks, making it centralized. It will reply to the ARP  requests  for
       the logical router port IPs.

       If  the  logical router doesn’t have a distributed gateway port connecting to the localnet
       logical switch  which  provides  external  connectivity,  or  if  it  has  more  than  one
       distributed gateway ports, then this option is ignored by OVN.

       The following happens when a VM sends an east-west traffic which needs to be routed:

              1.  The  packet  first enters the ingress pipeline, and then egress pipeline of the
                  source localnet logical switch datapath and is sent out via a localnet port  of
                  the source localnet logical switch (instead of sending it to router pipeline).

              2.  The  gateway  chassis  receives  the  packet  via a localnet port of the source
                  localnet logical switch and sends it to the integration bridge. The packet then
                  enters  the  ingress  pipeline, and then egress pipeline of the source localnet
                  logical switch datapath and enters the ingress pipeline of the  logical  router
                  datapath.

              3.  Routing decision is taken.

              4.  From  the  router  datapath, packet enters the ingress pipeline and then egress
                  pipeline of the destination localnet logical switch datapath. It then goes  out
                  of the integration bridge to the provider bridge ( belonging to the destination
                  logical switch) via a localnet port.

              5.  The destination chassis receives the packet via a localnet port and sends it to
                  the  integration bridge. The packet enters the ingress pipeline and then egress
                  pipeline of the destination localnet logical switch and  finally  delivered  to
                  the destination VM port.

       The following happens when a VM sends an external traffic which requires NATting:

              1.  The  packet  first enters the ingress pipeline, and then egress pipeline of the
                  source localnet logical switch datapath and is sent out via a localnet port  of
                  the source localnet logical switch (instead of sending it to router pipeline).

              2.  The  gateway  chassis  receives  the  packet  via a localnet port of the source
                  localnet logical switch and sends it to the integration bridge. The packet then
                  enters  the  ingress  pipeline, and then egress pipeline of the source localnet
                  logical switch datapath and enters the ingress pipeline of the  logical  router
                  datapath.

              3.  Routing decision is taken and NAT rules are applied.

              4.  From  the  router  datapath, packet enters the ingress pipeline and then egress
                  pipeline of the  localnet  logical  switch  datapath  which  provides  external
                  connectivity. It then goes out of the integration bridge to the provider bridge
                  (belonging to the logical switch which provides external  connectivity)  via  a
                  localnet port.

       The following happens for the reverse external traffic.

              1.  The  gateway  chassis  receives  the packet from a localnet port of the logical
                  switch which provides external connectivity. The packet then enters the ingress
                  pipeline  and  then  egress  pipeline  of  the  localnet  logical switch (which
                  provides external connectivity). The packet then enters the ingress pipeline of
                  the logical router datapath.

              2.  The  ingress  pipeline  of  the  logical  router datapath applies the unNATting
                  rules. The packet then enters the ingress pipeline and then egress pipeline  of
                  the  source  localnet logical switch. Since the source VM doesn’t reside in the
                  gateway chassis, the packet is sent out via  a  localnet  port  of  the  source
                  logical switch.

              3.  The  source chassis receives the packet via a localnet port and sends it to the
                  integration bridge. The packet enters the  ingress  pipeline  and  then  egress
                  pipeline  of  the  source localnet logical switch and finally gets delivered to
                  the source VM port.

       As an alternative to  reside-on-redirect-chassis,  OVN  supports  VLAN-based  redirection.
       Whereas   reside-on-redirect-chassis  centralizes  all  router  functionality,  VLAN-based
       redirection only changes how OVN redirects packets to  the  gateway  chassis.  By  setting
       options:redirect-type  to  bridged on a distributed gateway port, OVN redirects packets to
       the gateway chassis using the localnet port of the router’s peer logical  switch,  instead
       of a tunnel.

       If  the  logical router doesn’t have a distributed gateway port connecting to the localnet
       logical switch  which  provides  external  connectivity,  or  if  it  has  more  than  one
       distributed gateway ports, then this option is ignored by OVN.

       Following happens for bridged redirection:

              1.  On compute chassis, packet passes though logical router’s ingress pipeline.

              2.  If  logical  outport  is  gateway  chassis  attached router port then packet is
                  "redirected" to gateway chassis using peer logical switch’s localnet port.

              3.  This redirected packet has destination mac as router port mac (the one to which
                  gateway  chassis  is  attached).  Its  VLAN  id  is that of localnet port (peer
                  logical switch of the logical router port).

              4.  On the gateway chassis packet will enter the logical router pipeline again  and
                  this time it will passthrough egress pipeline as well.

              5.  Reverse traffic packet flows stays the same.

       Some guidelines and expections with bridged redirection:

              1.  Since  router  port  mac  is  destination  mac, hence it has to be ensured that
                  physical network learns it on ONLY from the gateway chassis. Which  means  that
                  ovn-chassis-mac-mappings  should be configure on all the compute nodes, so that
                  physical network never learn router port mac from compute nodes.

              2.  Since packet enters logical router ingress  pipeline  twice  (once  on  compute
                  chassis and again on gateway chassis), hence ttl will be decremented twice.

              3.  Default redirection type continues to be overlay. User can switch the redirect-
                  type between bridged and overlay by changing the value of options:redirect-type

   Life Cycle of a VTEP gateway
       A gateway is a chassis that forwards traffic between the OVN-managed  part  of  a  logical
       network  and  a  physical  VLAN,  extending a tunnel-based logical network into a physical
       network.

       The steps below refer often to details of the OVN and VTEP database  schemas.  Please  see
       ovn-sb(5), ovn-nb(5) and vtep(5), respectively, for the full story on these databases.

              1.  A  VTEP gateway’s life cycle begins with the administrator registering the VTEP
                  gateway  as  a  Physical_Switch  table  entry  in  the   VTEP   database.   The
                  ovn-controller-vtep  connected  to  this  VTEP database, will recognize the new
                  VTEP gateway and create a new Chassis table entry for it in the  OVN_Southbound
                  database.

              2.  The  administrator can then create a new Logical_Switch table entry, and bind a
                  particular vlan on a VTEP gateway’s port to any VTEP  logical  switch.  Once  a
                  VTEP  logical  switch  is bound to a VTEP gateway, the ovn-controller-vtep will
                  detect it and add its name to the vtep_logical_switches column of  the  Chassis
                  table  in  the  OVN_Southbound  database.  Note,  the tunnel_key column of VTEP
                  logical switch is not filled at creation. The ovn-controller-vtep will set  the
                  column  when  the  corresponding vtep logical switch is bound to an OVN logical
                  network.

              3.  Now, the administrator can use the CMS to add a VTEP logical switch to the  OVN
                  logical   network.   To   do   that,   the   CMS   must   first  create  a  new
                  Logical_Switch_Port table entry in the OVN_Northbound database. Then, the  type
                  column  of  this entry must be set to "vtep". Next, the vtep-logical-switch and
                  vtep-physical-switch keys in the options column must also be  specified,  since
                  multiple  VTEP  gateways  can attach to the same VTEP logical switch. Next, the
                  addresses column of this logical port must be set to "unknown", it will  add  a
                  priority  0  entry in "ls_in_l2_lkup" stage of logical switch ingress pipeline.
                  So, traffic with unrecorded mac by OVN would go through the Logical_Switch_Port
                  to physical network.

              4.  The  newly  created  logical  port  in  the  OVN_Northbound  database  and  its
                  configuration will be passed down to  the  OVN_Southbound  database  as  a  new
                  Port_Binding table entry. The ovn-controller-vtep will recognize the change and
                  bind the logical port to the corresponding VTEP gateway chassis.  Configuration
                  of  binding the same VTEP logical switch to a different OVN logical networks is
                  not allowed and a warning will be generated in the log.

              5.  Beside binding to the VTEP gateway chassis, the ovn-controller-vtep will update
                  the  tunnel_key  column  of  the  VTEP  logical  switch  to  the  corresponding
                  Datapath_Binding table entry’s tunnel_key for the bound OVN logical network.

              6.  Next, the ovn-controller-vtep will keep reacting to the configuration change in
                  the   Port_Binding   in   the   OVN_Northbound   database,   and  updating  the
                  Ucast_Macs_Remote table in the VTEP database. This allows the VTEP  gateway  to
                  understand  where  to  forward  the  unicast  traffic  coming from the extended
                  external network.

              7.  Eventually,  the  VTEP  gateway’s  life  cycle  ends  when  the   administrator
                  unregisters  the  VTEP  gateway from the VTEP database. The ovn-controller-vtep
                  will recognize the event and remove all related configurations  (Chassis  table
                  entry and port bindings) in the OVN_Southbound database.

              8.  When  the  ovn-controller-vtep is terminated, all related configurations in the
                  OVN_Southbound database and  the  VTEP  database  will  be  cleaned,  including
                  Chassis table entries for all registered VTEP gateways and their port bindings,
                  and all Ucast_Macs_Remote table entries and the Logical_Switch tunnel keys.

   OVN Deployments Interconnection
       It is not uncommon for an operator to deploy multiple OVN clusters, for two main  reasons.
       Firstly, an operator may prefer to deploy one OVN cluster for each availability zone, e.g.
       in different physical regions, to avoid single point of failure. Secondly, there is always
       an upper limit for a single OVN control plane to scale.

       Although  the control planes of the different availability zone (AZ)s are independent from
       each other, the workloads from different AZs may need to communicate across the zones. The
       OVN  interconnection  feature  provides  a  native way to interconnect different AZs by L3
       routing through transit overlay networks between logical routers of different AZs.

       A global OVN Interconnection Northbound database is introduced for the operator  (probably
       through  CMS  systems)  to configure transit logical switches that connect logical routers
       from different AZs. A transit switch is similar to a regular logical  switch,  but  it  is
       used  for  interconnection  purpose  only.  Typically,  each transit switch can be used to
       connect all logical routers that belong to same tenant across all AZs.

       A dedicated daemon process ovn-ic, OVN interconnection controller, in each AZ will consume
       this  data  and  populate corresponding logical switches to their own northbound databases
       for each AZ, so that logical routers can be connected to the transit  switch  by  creating
       patch  port pairs in their northbound databases. Any router ports connected to the transit
       switches are considered interconnection ports, which will be exchanged between AZs.

       Physically, when workloads from different AZs communicate,  packets  need  to  go  through
       multiple  hops:  source  chassis,  source  gateway,  destination  gateway  and destination
       chassis. All these hops are connected through tunnels so  that  the  packets  never  leave
       overlay  networks. A distributed gateway port is required to connect the logical router to
       a transit switch, with a gateway chassis specified, so that the traffic can  be  forwarded
       through the gateway chassis.

       A  global  OVN  Interconnection  Southbound  database is introduced for exchanging control
       plane information between the AZs. The data in this database is populated and consumed  by
       the ovn-ic, of each AZ. The main information in this database includes:

              •      Datapath  bindings  for  transit  switches, which mainly contains the tunnel
                     keys generated for each transit switch. Separate key ranges are reserved for
                     transit  switches  so  that  they  will  never conflict with any tunnel keys
                     locally assigned for datapaths within each AZ.

              •      Availability zones, which are registered by ovn-ic from each AZ.

              •      Gateways.  Each  AZ  specifies  chassises  that  are  supposed  to  work  as
                     interconnection  gateways,  and the ovn-ic will populate this information to
                     the interconnection southbound DB. The ovn-ic from all the  other  AZs  will
                     learn the gateways and populate to their own southbound DB as a chassis.

              •      Port  bindings  for logical switch ports created on the transit switch. Each
                     AZ  maintains  their  logical   router   to   transit   switch   connections
                     independently,  but  ovn-ic  automatically  populates local port bindings on
                     transit switches to the global interconnection  southbound  DB,  and  learns
                     remote  port  bindings  from  other  AZs  back  to  its  own  northbound and
                     southbound DBs, so that logical flows can be produced and then translated to
                     OVS flows locally, which finally enables data plane communication.

              •      Routes  that  are  advertised  between different AZs. If enabled, routes are
                     automatically exchanged by ovn-ic. Both static routes and directly connected
                     subnets  are advertised. Options in options column of the NB_Global table of
                     OVN_NB database  control  the  behavior  of  route  advertisement,  such  as
                     enable/disable  the  advertising/learning routes, whether default routes are
                     advertised/learned, and blacklisted CIDRs. See ovn-nb(5) for more details.

       The tunnel keys for transit switch datapaths and related  port  bindings  must  be  agreed
       across  all  AZs.  This  is  ensured  by  generating  and  storing  the keys in the global
       interconnection southbound database. Any ovn-ic from any AZ can allocate the key, but race
       conditions are solved by enforcing unique index for the column in the database.

       Once  each AZ’s NB and SB databases are populated with interconnection switches and ports,
       and agreed upon the tunnel keys, data plane communication between the AZs are established.

       When VXLAN tunneling is enabled in an OVN cluster, due to the limited range available  for
       VNIs, Interconnection feature is not supported.

     A day in the life of a packet crossing AZs

              1.  An  IP  packet  is  sent  out  from  a  VIF  on a hypervisor (HV1) of AZ1, with
                  destination IP belonging to a VIF in AZ2.

              2.  In HV1’s OVS flow tables, the packet goes through logical  switch  and  logical
                  router pipelines, and in a logical router pipeline, the routing stage finds out
                  the next hop for the destination IP, which belongs to a remote  logical  router
                  port  in  AZ2, and the output port, which is a chassis-redirect port located on
                  an interconnection gateway (GW1 in AZ1), so HV1 sends the packet to GW1 through
                  tunnel.

              3.  On  GW1,  it  continues  with  the logical router pipe line and switches to the
                  transit switch’s pipeline through the peer port of the chassis  redirect  port.
                  In the transit switch’s pipeline it outputs to the remote logical port which is
                  located on a gateway (GW2) in AZ2, so the  GW1  sends  the  packet  to  GW2  in
                  tunnel.

              4.  On  GW2,  it  continues  with  the  transit switch pipeline and switches to the
                  logical router pipeline through the peer port, which is a chassis redirect port
                  that is located on GW2. The logical router pipeline then forwards the packet to
                  relevant logical pipelines according to the destination IP address, and figures
                  out  the MAC and location of the destination VIF port - a hypervisor (HV2). The
                  GW2 then sends the packet to HV2 in tunnel.

              5.  On HV2, the packet is delivered to  the  final  destination  VIF  port  by  the
                  logical   switch   egress   pipeline,   just  the  same  way  as  for  intra-AZ
                  communications.

   Native OVN services for external logical ports
       To support OVN native services (like DHCP/IPv6 RA/DNS lookup) to the cloud resources which
       are external, OVN supports external logical ports.

       Below are some of the use cases where external ports can be used.

              •      VMs  connected  to SR-IOV nics - Traffic from these VMs by passes the kernel
                     stack and local ovn-controller do not bind these ports and cannot serve  the
                     native services.

              •      When CMS supports provisioning baremetal servers.

       OVN  will  provide  the native services if CMS has done the below configuration in the OVN
       Northbound Database.

              •      A row is created in Logical_Switch_Port, configuring  the  addresses  column
                     and setting the type to external.

              •      ha_chassis_group column is configured.

              •      The   HA   chassis   which   belongs   to  the  HA  chassis  group  has  the
                     ovn-bridge-mappings configured and has proper L2 connectivity so that it can
                     receive  the  DHCP  and  other  related  request packets from these external
                     resources.

              •      The Logical_Switch of this port has a localnet port.

              •      Native OVN services are enabled by configuring the DHCP  and  other  options
                     like the way it is done for the normal logical ports.

       It is recommended to use the same HA chassis group for all the external ports of a logical
       switch. Otherwise, the physical switch might see MAC flap  issue  when  different  chassis
       provide  the  native  services.  For example when supporting native DHCPv4 service, DHCPv4
       server mac (configured in options:server_mac column  in  table  DHCP_Options)  originating
       from  different  ports  can  cause MAC flap issue. The MAC of the logical router IP(s) can
       also flap if the same HA chassis group is not set for all the external ports of a  logical
       switch.

SECURITY

   Role-Based Access Controls for the Southbound DB
       In order to provide additional security against the possibility of an OVN chassis becoming
       compromised in such a way as to allow rogue software to make  arbitrary  modifications  to
       the southbound database state and thus disrupt the OVN network, role-based access controls
       (see ovsdb-server(1) for additional details) are provided for the southbound database.

       The implementation of role-based access controls  (RBAC)  requires  the  addition  of  two
       tables to an OVSDB schema: the RBAC_Role table, which is indexed by role name and maps the
       the names of the various tables that may be modifiable for a given role to individual rows
       in  a  permissions table containing detailed permission information for that role, and the
       permission table itself which consists of rows containing the following information:

              Table Name
                     The name of the associated table. This column exists primarily as an aid for
                     humans reading the contents of this table.

              Auth Criteria
                     A  set  of  strings containing the names of columns (or column:key pairs for
                     columns containing string:string maps). The contents of at least one of  the
                     columns  or  column:key values in a row to be modified, inserted, or deleted
                     must be equal to the ID of the client attempting to act on the row in  order
                     for the authorization check to pass. If the authorization criteria is empty,
                     authorization checking is disabled and all clients  for  the  role  will  be
                     treated as authorized.

              Insert/Delete
                     Row   insertion/deletion   permission;   boolean  value  indicating  whether
                     insertion and deletion of rows is allowed for the associated table. If true,
                     insertion and deletion of rows is allowed for authorized clients.

              Updatable Columns
                     A  set  of  strings containing the names of columns or column:key pairs that
                     may be updated or mutated by authorized clients.  Modifications  to  columns
                     within  a row are only permitted when the authorization check for the client
                     passes and all columns to be modified are included in this set of modifiable
                     columns.

       RBAC  configuration for the OVN southbound database is maintained by ovn-northd. With RBAC
       enabled, modifications are only  permitted  for  the  Chassis,  Encap,  Port_Binding,  and
       MAC_Binding tables, and are restricted as follows:

              Chassis
                     Authorization: client ID must match the chassis name.

                     Insert/Delete: authorized row insertion and deletion are permitted.

                     Update:  The columns nb_cfg, external_ids, encaps, and vtep_logical_switches
                     may be modified when authorized.

              Encap  Authorization: client ID must match the chassis name.

                     Insert/Delete: row insertion and row deletion are permitted.

                     Update: The columns type, options, and ip can be modified.

              Port_Binding
                     Authorization: disabled (all clients are  considered  authorized.  A  future
                     enhancement  may  add  columns (or keys to external_ids) in order to control
                     which chassis are allowed to bind each port.

                     Insert/Delete:  row  insertion/deletion  are   not   permitted   (ovn-northd
                     maintains rows in this table.

                     Update: Only modifications to the chassis column are permitted.

              MAC_Binding
                     Authorization: disabled (all clients are considered to be authorized).

                     Insert/Delete: row insertion/deletion are permitted.

                     Update:  The  columns logical_port, ip, mac, and datapath may be modified by
                     ovn-controller.

              IGMP_Group
                     Authorization: disabled (all clients are considered to be authorized).

                     Insert/Delete: row insertion/deletion are permitted.

                     Update: The columns address, chassis, datapath, and ports may be modified by
                     ovn-controller.

       Enabling  RBAC  for  ovn-controller  connections  to  the southbound database requires the
       following steps:

              1.  Creating SSL certificates for each chassis with the certificate CN field set to
                  the chassis name (e.g. for a chassis with external-ids:system-id=chassis-1, via
                  the command "ovs-pki -u req+sign chassis-1 switch").

              2.  Configuring each ovn-controller to use SSL when connecting  to  the  southbound
                  database        (e.g.        via        "ovs-vsctl       set       open       .
                  external-ids:ovn-remote=ssl:x.x.x.x:6642").

              3.  Configuring a southbound database SSL remote with "ovn-controller"  role  (e.g.
                  via "ovn-sbctl set-connection role=ovn-controller pssl:6642").

   Encrypt Tunnel Traffic with IPsec
       OVN  tunnel  traffic  goes  through  physical routers and switches. These physical devices
       could be  untrusted  (devices  in  public  network)  or  might  be  compromised.  Enabling
       encryption  to  the  tunnel  traffic can prevent the traffic data from being monitored and
       manipulated.

       The tunnel traffic is encrypted  with  IPsec.  The  CMS  sets  the  ipsec  column  in  the
       northbound NB_Global table to enable or disable IPsec encrytion. If ipsec is true, all OVN
       tunnels will be encrypted. If ipsec is false, no OVN tunnels will be encrypted.

       When CMS updates the ipsec column in the northbound NB_Global table, ovn-northd copies the
       value  to  the  ipsec  column  in  the  southbound SB_Global table. ovn-controller in each
       chassis monitors the southbound database and sets the options of the OVS tunnel  interface
       accordingly.  OVS  tunnel  interface options are monitored by the ovs-monitor-ipsec daemon
       which configures IKE daemon to set up IPsec connections.

       Chassis authenticates each other by using certificate. The authentication succeeds if  the
       other end in tunnel presents a certificate signed by a trusted CA and the common name (CN)
       matches the expected chassis name. The SSL certificates used in role-based access controls
       (RBAC)  can  be  used  in  IPsec.  Or  use  ovs-pki  to create different certificates. The
       certificate is required to be x.509 version 3, and with CN field and subjectAltName  field
       being set to the chassis name.

       The  CA  certificate,  chassis certificate and private key are required to be installed in
       each chassis before enabling IPsec. Please see ovs-vswitchd.conf.db(5) for setting  up  CA
       based IPsec authentication.

DESIGN DECISIONS

   Tunnel Encapsulations
       In  general,  OVN  annotates  logical network packets that it sends from one hypervisor to
       another  with  the  following  three  pieces  of  metadata,  which  are  encoded   in   an
       encapsulation-specific fashion:

              •      24-bit  logical  datapath  identifier, from the tunnel_key column in the OVN
                     Southbound Datapath_Binding table.

              •      15-bit logical ingress port identifier. ID 0 is reserved  for  internal  use
                     within OVN. IDs 1 through 32767, inclusive, may be assigned to logical ports
                     (see the tunnel_key column in the OVN Southbound Port_Binding table).

              •      16-bit logical egress port identifier. IDs 0 through  32767  have  the  same
                     meaning  as  for  logical ingress ports. IDs 32768 through 65535, inclusive,
                     may be assigned to logical multicast groups (see the  tunnel_key  column  in
                     the OVN Southbound Multicast_Group table).

       When  VXLAN is enabled on any hypervisor in a cluster, datapath and egress port identifier
       ranges are reduced to 12-bits. This is done because only STT and Geneve provide the  large
       space  for metadata (over 32 bits per packet). To accommodate for VXLAN, 24 bits available
       are split as follows:

              •      12-bit logical datapath identifier, derived from the  tunnel_key  column  in
                     the OVN Southbound Datapath_Binding table.

              •      12-bit  logical  egress  port  identifier.  IDs  0 through 2047 are used for
                     unicast output ports. IDs 2048 through 4095, inclusive, may be  assigned  to
                     logical  multicast  groups  (see the tunnel_key column in the OVN Southbound
                     Multicast_Group table). For multicast group tunnel keys, a  special  mapping
                     scheme  is  used  to  internally  transform from internal OVN 16-bit keys to
                     12-bit values before sending packets through a VXLAN tunnel, and  back  from
                     12-bit  tunnel  keys  to  16-bit  values when receiving packets from a VXLAN
                     tunnel.

              •      No logical ingress port identifier.

       The limited space available for metadata when VXLAN tunnels are enabled in a  cluster  put
       the following functional limitations onto features available to users:

              •      The maximum number of networks is reduced to 4096.

              •      The maximum number of ports per network is reduced to 2048.

              •      ACLs matching against logical ingress port identifiers are not supported.

              •      OVN interconnection feature is not supported.

       In  addition to functional limitations described above, the following should be considered
       before enabling it in your cluster:

              •      STT and Geneve use randomized UDP or TCP source ports that allows  efficient
                     distribution  among  multiple  paths  in environments that use ECMP in their
                     underlay.

              •      NICs  are  available  to  offload   STT   and   Geneve   encapsulation   and
                     decapsulation.

       Due  to  its  flexibility,  the preferred encapsulation between hypervisors is Geneve. For
       Geneve encapsulation, OVN transmits the logical datapath identifier in the Geneve VNI. OVN
       transmits  the  logical  ingress and logical egress ports in a TLV with class 0x0102, type
       0x80, and a 32-bit value encoded as follows, from MSB to LSB:

         1       15          16
       +---+------------+-----------+
       |rsv|ingress port|egress port|
       +---+------------+-----------+
         0

       Environments whose NICs lack Geneve offload may prefer STT encapsulation  for  performance
       reasons.  For  STT  encapsulation, OVN encodes all three pieces of logical metadata in the
       STT 64-bit tunnel ID as follows, from MSB to LSB:

           9          15          16         24
       +--------+------------+-----------+--------+
       |reserved|ingress port|egress port|datapath|
       +--------+------------+-----------+--------+
           0

       For connecting to gateways, in addition to Geneve and STT,  OVN  supports  VXLAN,  because
       only  VXLAN  support  is  common on top-of-rack (ToR) switches. Currently, gateways have a
       feature set that matches the capabilities as defined by the VTEP schema, so fewer bits  of
       metadata  are  necessary.  In the future, gateways that do not support encapsulations with
       large amounts of metadata may continue to have a reduced feature set.