NAME

       ipmiseld.conf - ipmiseld configuration file

DESCRIPTION

       The ipmiseld configuration file configures the ipmiseld daemon.

       The default configuration file loaded is /etc/freeipmi//ipmiseld.conf.

       The  configuration  options  that  can  be  specified  in  the  configuration file are listed below. Each
       configuration option must be listed on a separate line. Arguments for an  option  are  separated  by  any
       amount  of  whitespace.  Multiple  arguments are also separated by whitespace.  Comments can be marked by
       using the pound sign ("#") character, and lines can be continued on the next using backslash ("\").

       Note that it is possible to list the username, password and other potentially  sensitive  information  in
       the  configuration  file.  If  this  data is stored in a configuration file, system administrators should
       limit access to this file.

IPMISELD CONFIGURATION OPTIONS

       driver-type IPMIDRIVER
              Specify the driver type to use.

       disable-auto-probe ENABLE|DISABLE
              Specify if IPMI devices should be probed for settings.

       driver-address DRIVER-ADDRESS
              Specify the in-band driver address to use.

       driver-device DEVICE
              Specify the in-band driver device path to use.

       register-spacing REGISTER-SPACING
              Specify the in-band driver register spacing to use.

       target-channel-number CHANNEL-NUMBER
              Specify the in-band driver target channel number.

       target-slave-address SLAVE-ADDRESS
              Specify the in-band driver target slave address.

       hostname IPMIHOST1,IPMIHOST2,...
              Specify the remote host(s) to communicate with. Multiple hostnames may be separated  by  comma  or
              may be specified in a range format.

       username USERNAME
              Specify the username to use.

       password PASSWORD
              Specify the password to use.

       k_g str
              Specify the BMC key (K_g) to use. Prefix with '0x' to enter the key in hex.

       session-timeout MILLISECONDS
              Specify the session timeout length to use in milliseconds.

       retransmission-timeout MILLISECONDS
              Specify the retransmission timeout length to use in milliseconds.

       authentication-type AUTHENTICATION-TYPE
              Specify  the  authentication  type to use. The following authentication types are supported: NONE,
              STRAIGHT_PASSWORD_KEY, MD2, and MD5.

       cipher-suite-id CIPHER-SUITE-ID
              Specify the cipher suite id to use. The following cipher suite ids are supported: 0, 1, 2,  3,  6,
              7, 8, 11, 12.

       privilege-level PRIVILEGE-LEVEL
              Specify  the  privilege type to use. The following privilege levels are supported: USER, OPERATOR,
              ADMIN.

       workaround-flags WORKAROUNDS
              Specify workaround flags to use. Multiple workarounds can be specified  separated  by  whitespace.
              Please  see  tool  manpages  for  details about available workarounds for each tool. The following
              workarounds are supported: assumeio, spinpoll,  idzero,  forcepermsg,  unexpectedauth,  endianseq,
              authcap, intel20, supermicro20, sun20, opensesspriv, integritycheckvalue, assumesystemevent.

       verbose-count COUNT
              Specify default verbose count to use for ipmi-sel(8).

       sensors-types TYPE-LIST
              Specify  sensor  types  of  SEL  events  to  log.  Multiple  types  can  be specified separated by
              whitespace. Users may specify sensor types by string or by number (decimal  or  hex).  Please  see
              ipmi-sel(8) --list-types option to see possible string input types.

       exclude-sensor-types ENSOR-TYPES-LIST
              Specify  sensor  types  of  SEL events to not log. default sensor types to not show sensor outputs
              for. Multiple sensor types can be specified separated by  whitespace.  Users  may  specify  sensor
              types  by  string  or by number. Please see ipmi-sel(8) --list-types option to see possible string
              input types.

       system-event-only ENABLE|DISABLE
              Specify if output should only include system event records.

       oem-event-only ENABLE|DISABLE
              Specify if output should only include OEM event records.

       event-state-config-file FILE
              Specify the event state configuration file.

       interpret-oem-data ENABLE|DISABLE
              Specify if ipmiseld should attempt to interpret OEM data or not.

       entity-sensor-names ENABLE|DISABLE
              Specify if output of sensor names should include entity ids and instances or not.

       non-abbreviated-units ENABLE|DISABLE
              Specify if output should have units abbreviated by default or not.

       event-state-filter FILTERSTRING
              Specify event states to be filtered out and not logged.

       --warning-threshold PERCENTINT
              Specify SEL fullness warning threshold as an integer percentage.

       --clear-threshold PERCENTINT
              Specify SEL fullness clear threshold as an integer percentage.

       system-event-format FORMATSTRING
              Specify the format of the log output when a SEL system event is encountered.

       oem-timestamped-event-format FORMATSTRING
              Specify the format of the log output when a SEL OEM timestamped event is encountered.

       oem-non-timestamped-event-format FORMATSTRING
              Specify the format of the log output when a SEL OEM non-timestamped event is encountered.

       poll-interval SECONDS
              Specify the poll interval to check the SEL for new events.

       log-facility STRING
              Specify the log facility to use.

       log-priority STRING
              Specify the log priority to use.

       cache-directory DIRECTORY
              Specify the cache directory to use.

       ignore-sdr DISABLE
              Specify if the SDR should be ignored.

       re-download-sdr DISABLE
              Specify if the SDR should be re-downloaded on start.

       clear-sel DISABLE
              Specify if the SEL should be cleared on start.

       threadpool-count NUM
              Specify the threadpool count for parallel SEL polling.