Provided by: ganeti-2.16_2.16.0~rc2-1build1_all
Name
ganeti-os-interface - Specifications for guest OS types
DESCRIPTION
The method of supporting guest operating systems in Ganeti is to have, for each guest OS type, a directory containing a number of required files. This directory must be present across all nodes (Ganeti doesn't replicate it) in order for the OS to be usable by Ganeti.
REFERENCE
There are eight required files: create, import, export, rename, verify (executables), ganeti_api_version, variants.list and parameters.list (text files). Common environment All commands will get their input via environment variables. A common set of variables will be exported for all commands, and some of them might have extra ones. Note that all counts are zero-based. Since Ganeti version 2.5, the environment will be cleaned up before being passed to scripts, therefore they will not inherit the environment in with which the ganeti node daemon was started. If you depend on any environment variables (non-Ganeti), then you will need to define or source them appropriately. OS_API_VERSION The OS API version that the rest of the environment conforms to. INSTANCE_NAME The instance name the script should operate on. INSTANCE_OS, OS_NAME Both names point to the name of the instance's OS as Ganeti knows it. This can simplify the OS scripts by providing the same scripts under multiple names, and then the scripts can use this name to alter their behaviour. With OS API 15 changing the script behavior based on this variable is deprecated: OS_VARIANT should be used instead (see below). OS_VARIANT The variant of the OS which should be installed. Each OS must support all variants listed under its variants.list file, and may support more. Any more supported variants should be properly documented in the per-OS documentation. HYPERVISOR The hypervisor of this instance. DISK_COUNT The number of disks the instance has. The actual disk definitions are in a set of additional variables. The instance's disk will be numbered from 0 to this value minus one. DISK ()%N_PATH The path to the storage for disk N of the instance. This might be either a block device or a regular file, in which case the OS scripts should use losetup (if they need to mount it). E.g. the first disk of the instance might be exported as DISK_0_PATH=/dev/drbd0. If the disk is only accessible via a userspace URI, this not be set. DISK ()%N_URI The userspace URI to the storage for disk N of the instance, if configured. DISK ()%N_ACCESS This is how the hypervisor will export the instance disks: either read-write (rw) or read-only (ro). DISK ()%N_UUID The uuid associated with the N-th disk of the instance. DISK ()%N_NAME (Optional) The name, if any, associated with the N-th disk of the instance. DISK ()%N_FRONTEND_TYPE (Optional) If applicable to the current hypervisor type: the type of the device exported by the hypervisor. For example, the Xen HVM hypervisor can export disks as either paravirtual or ioemu. DISK ()%N_BACKEND_TYPE How files are visible on the node side. This can be either block (when using block devices) or file:type, where type is either loop, blktap or blktap2, depending on how the hypervisor will be configured. Note that not all backend types apply to all hypervisors. NIC_COUNT Similar to the DISK_COUNT, this represents the number of NICs of the instance. NIC ()%N_MAC The MAC address associated with this interface. NIC ()%N_UUID The uuid associated with the N-th NIC of the instance. NIC ()%N_NAME (Optional) The name, if any, associated with the N-th NIC of the instance. NIC ()%N_IP The IP address, if any, associated with the N-th NIC of the instance. NIC ()%N_MODE The NIC mode, routed, bridged or openvswitch NIC ()%N_BRIDGE The bridge to which this NIC will be attached. This variable is defined only when the NIC is in bridged mode. NIC ()%N_LINK In bridged or openvswitch mode, this is the interface to which the NIC will be attached (same as NIC_%N_BRIDGE for bridged). In routed mode it is the routing table which will be used by the hypervisor to insert the appropriate routes. NIC ()%N_FRONTEND_TYPE (Optional) If applicable, the type of the exported NIC to the instance, this can be one of: rtl8139, ne2k_pci, ne2k_isa, paravirtual. NIC ()%d_NETWORK_NAME (Optional) If a NIC network is specified, the network's name. NIC ()%d_NETWORK_UUID (Optional) If a NIC network is specified, the network's uuid. NIC ()%d_NETWORK_FAMILY (Optional) If a NIC network is specified, the network's family. NIC ()%d_NETWORK_SUBNET (Optional) If a NIC network is specified, the network's IPv4 subnet. NIC ()%d_NETWORK_GATEWAY (Optional) If a NIC network is specified, the network's IPv4 gateway. NIC ()%d_NETWORK_SUBNET6 (Optional) If a NIC network is specified, the network's IPv6 subnet. NIC ()%d_NETWORK_GATEWAY6 (Optional) If a NIC network is specified, the network's IPv6 gateway. NIC ()%d_NETWORK_MAC_PREFIX (Optional) If a NIC network is specified, the network's mac prefix. NIC ()%d_NETWORK_TAGS (Optional) If a NIC network is specified, the network's tags, space separated. OSP ()name Each OS parameter (see below) will be exported in its own variable, prefixed with OSP_, and upper-cased. For example, a dhcp parameter will be exported as OSP_DHCP. DEBUG_LEVEL If non-zero, this should cause the OS script to generate verbose logs of its execution, for troubleshooting purposes. Currently only 0 and 1 are valid values.
EXECUTABLE SCRIPTS
create The create command is used for creating a new instance from scratch. It has no additional environment variables bside the common ones. The INSTANCE_NAME variable denotes the name of the instance, which is guaranteed to resolve to an IP address. The create script should configure the instance according to this name. It can configure the IP statically or not, depending on the deployment environment. The INSTANCE_REINSTALL variable is set to 1 when this create request is reinstalling an existing instance, rather than creating a new one. This can be used, for example, to preserve some data in the old instance in an OS-specific way. export This command is used in order to make a backup of a given disk of the instance. The command should write to stdout a dump of the given block device. The output of this program will be passed during restore to the import command. The specific disk to backup is denoted by four additional environment variables: EXPORT_INDEX The index in the instance disks structure (and could be used for example to skip the second disk if not needed for backup). EXPORT_DISK_PATH Alias for DISK_N_PATH. It is duplicated here for easier usage by shell scripts (rather than parse the DISK_... variables). EXPORT_DISK_URI Alias for DISK_N_URI, analagous to EXPORT_DISK_PATH. EXPORT_DEVICE Historical alias for EXPORT_DISK_PATH. To provide the user with an estimate on how long the export will take, a predicted size can be written to the file descriptor passed in the variable EXP_SIZE_FD. The value is in bytes and must be terminated by a newline character (\n). Older versions of Ganeti don't support this feature, hence the variable should be checked before use. Example: if test -n "$EXP_SIZE_FD"; then blockdev --getsize64 $blockdev >&$EXP_SIZE_FD fi import The import command is used for restoring an instance from a backup as done by export. The arguments are the similar to those passed to export, whose output will be provided on stdin. The difference in variables is that the current disk is denoted by IMPORT_DISK_PATH, IMPORT_DISK_URI, IMPORT_DEVICE and IMPORT_INDEX (instead of EXPORT_...). rename This command is used in order to perform a rename at the instance OS level, after the instance has been renamed in Ganeti. The command should do whatever steps are required to ensure that the instance is updated to use the new name, if the operating system supports it. Note that it is acceptable for the rename script to do nothing at all, however be warned that in this case, there will be a desynchronization between what gnt-instance list shows you and the actual hostname of the instance. The script will be passed one additional environment variable called OLD_INSTANCE_NAME which holds the old instance name. The INSTANCE_NAME variable holds the new instance name. A very simple rename script should at least change the hostname and IP address of the instance, leaving the administrator to update the other services. verify The verify script is used to verify consistency of the OS parameters (see below). The command should take one or more arguments denoting what checks should be performed, and return a proper exit code depending on whether the validation failed or succeeded. Currently (API version 20), only one parameter is supported: parameters. This should validate the OSP_ variables from the environment, and output diagnostic messages in case the validation fails. For the dhcp parameter given as example above, a verification script could be: #!/bin/sh case $OSP_DHCP in ""|yes|no) ;; *) echo "Invalid value '$OSP_DHCP' for the dhcp parameter" 1>&2 exit 1; ;; esac exit 0
TEXT FILES
ganeti_api_version The ganeti_api_version file is a plain text file containing the version(s) of the guest OS API that this OS definition complies with, one per line. The version documented by this man page is 20, so this file must contain the number 20 followed by a newline if only this version is supported. A script compatible with more than one Ganeti version should contain the most recent version first (i.e. 20), followed by the old version(s) (in this case 15 and/or 10). variants.list variants.list is a plain text file containing all the declared supported variants for this OS, one per line. If this file is missing or empty, then the OS won't be considered to support variants. Empty lines and lines starting with a hash (#) are ignored. parameters.list This file declares the parameters supported by the OS, one parameter per line, with name and description (space and/or tab separated). For example: dhcp Whether to enable (yes) or disable (no) dhcp root_size The size of the root partition, in GiB The parameters can then be used in instance add or modification, as follows: # gnt-instance add -O dhcp=no,root_size=8 ...
NOTES
Backwards compatibility Ganeti 2.3 and up is compatible with API versions 10, 15 and 20. The OS parameters and related scripts (verify) are only supported in version 20. The variants functionality (variants.list, and OS_VARIANT env. var) are supported/present only in version 15 and up. Common behaviour All the scripts should display an usage message when called with a wrong number of arguments or when the first argument is -h or --help. Upgrading from old versions Version 15 to 20 The parameters.list file and verify script have been added. For no parameters, an empty parameters file and an empty verify script which returns success can be used. Version 10 to 15 The variants.list file has been added, so OSes should support at least one variant, declaring it in that file and must be prepared to parse the OS_VARIANT environment variable. OSes are free to support more variants than just the declared ones. Note that this file is optional; without it, the variants functionality is disabled. Version 5 to 10 The method for passing data has changed from command line options to environment variables, so scripts should be modified to use these. For an example of how this can be done in a way compatible with both versions, feel free to look at the debootstrap instance's common.sh auxiliary script. Also, instances can have now a variable number of disks, not only two, and a variable number of NICs (instead of fixed one), so the scripts should deal with this. The biggest change is in the import/export, which are called once per disk, instead of once per instance. Version 4 to 5 The rename script has been added. If you don't want to do any changes on the instances after a rename, you can migrate the OS definition to version 5 by creating the rename script simply as: #!/bin/sh exit 0 Note that the script must be executable.
REPORTING BUGS
Report bugs to project website (http://code.google.com/p/ganeti/) or contact the developers using the Ganeti mailing list (ganeti@googlegroups.com).
SEE ALSO
Ganeti overview and specifications: ganeti(7) (general overview), ganeti-os-interface(7) (guest OS definitions), ganeti-extstorage-interface(7) (external storage providers). Ganeti commands: gnt-cluster(8) (cluster-wide commands), gnt-job(8) (job-related commands), gnt-node(8) (node-related commands), gnt-instance(8) (instance commands), gnt-os(8) (guest OS commands), gnt-storage(8) (storage commands), gnt-group(8) (node group commands), gnt-backup(8) (instance import/export commands), gnt-debug(8) (debug commands). Ganeti daemons: ganeti-watcher(8) (automatic instance restarter), ganeti-cleaner(8) (job queue cleaner), ganeti-noded(8) (node daemon), ganeti-rapi(8) (remote API daemon). Ganeti htools: htools(1) (generic binary), hbal(1) (cluster balancer), hspace(1) (capacity calculation), hail(1) (IAllocator plugin), hscan(1) (data gatherer from remote clusters), hinfo(1) (cluster information printer), mon-collector(7) (data collectors interface).
COPYRIGHT
Copyright (C) 2006-2015 Google Inc. All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.