bionic (1) ocamlopt.1.gz

Provided by: ocaml-nox_4.05.0-10ubuntu1_amd64 bug

NAME

       ocamlopt - The OCaml native-code compiler

SYNOPSIS

       ocamlopt [ options ] filename ...

       ocamlopt.opt (same options)

DESCRIPTION

       The  OCaml  high-performance  native-code compiler ocamlopt(1) compiles OCaml source files to native code
       object files and link these object files to produce standalone executables.

       The ocamlopt(1) command has a command-line interface very close to that of  ocamlc(1).   It  accepts  the
       same types of arguments and processes them sequentially, after all options have been processed:

       Arguments ending in .mli are taken to be source files for compilation unit interfaces. Interfaces specify
       the names exported by compilation units: they declare value names with their types,  define  public  data
       types,  declare  abstract data types, and so on. From the file x.mli, the ocamlopt(1) compiler produces a
       compiled interface in the file x.cmi.  The interface produced  is  identical  to  that  produced  by  the
       bytecode compiler ocamlc(1).

       Arguments   ending   in  .ml  are  taken  to  be  source  files  for  compilation  unit  implementations.
       Implementations provide definitions for the names exported by the unit, and also contain  expressions  to
       be  evaluated  for  their side-effects.  From the file x.ml, the ocamlopt(1) compiler produces two files:
       x.o, containing native object code, and x.cmx, containing extra information for linking and  optimization
       of the clients of the unit. The compiled implementation should always be referred to under the name x.cmx
       (when given a .o file, ocamlopt(1) assumes that it contains code compiled from C, not from OCaml).

       The implementation is checked against the interface file x.mli (if it exists) as described in the  manual
       for ocamlc(1).

       Arguments  ending  in  .cmx are taken to be compiled object code.  These files are linked together, along
       with the object files obtained by compiling .ml arguments (if any), and the OCaml  standard  library,  to
       produce  a native-code executable program. The order in which .cmx and .ml arguments are presented on the
       command line is relevant: compilation units are initialized in that order at run-time, and it is a  link-
       time error to use a component of a unit before having initialized it. Hence, a given x.cmx file must come
       before all .cmx files that refer to the unit x.

       Arguments ending in .cmxa are taken to be libraries of object code.  Such a library packs  in  two  files
       lib.cmxa  and  lib.a a set of object files (.cmx/.o files). Libraries are build with ocamlopt -a (see the
       description of the -a option below). The object files contained in the library are linked as regular .cmx
       files  (see  above), in the order specified when the library was built. The only difference is that if an
       object file contained in a library is not referenced anywhere in the program, then it is not linked in.

       Arguments ending in .c are passed to the C compiler, which generates a .o object file. This  object  file
       is linked with the program.

       Arguments  ending  in  .o  or .a are assumed to be C object files and libraries. They are linked with the
       program.

       The output of the linking phase is a regular Unix executable file. It does not need ocamlrun(1) to run.

       ocamlopt.opt is the same compiler as ocamlopt, but compiled with itself  instead  of  with  the  bytecode
       compiler  ocamlc(1).   Thus,  it behaves exactly like ocamlopt, but compiles faster.  ocamlopt.opt is not
       available in all installations of OCaml.

OPTIONS

       The following command-line options are recognized by ocamlopt(1).

       -a     Build a library (.cmxa/.a file) with the object files (.cmx/.o files) given on the  command  line,
              instead  of  linking them into an executable file. The name of the library must be set with the -o
              option.

              If -cclib or -ccopt options are passed on the command  line,  these  options  are  stored  in  the
              resulting   .cmxa   library.   Then,  linking  with  this  library  automatically  adds  back  the
              -cclib and -ccopt options as if they had been provided on the command line, unless the -noautolink
              option  is  given. Additionally, a substring $CAMLORIGIN inside a  -ccopt options will be replaced
              by the full path to the .cma library, excluding the filename.

       -absname
              Show absolute filenames in error messages.

       -annot Dump  detailed  information  about  the  compilation  (types,  bindings,  tail-calls,  etc).   The
              information  for  file  src.ml  is put into file src.annot.  In case of a type error, dump all the
              information inferred by the type-checker before the error. The src.annot file can be used with the
              emacs commands given in emacs/caml-types.el to display types and other annotations interactively.

       -bin-annot
              Dump  detailed  information  about  the  compilation  (types, bindings, tail-calls, etc) in binary
              format. The information for file src.ml is put into file src.cmt.  In case of a type  error,  dump
              all  the information inferred by the type-checker before the error.  The annotation files produced
              by -bin-annot contain more information and are much  more  compact  than  the  files  produced  by
              -annot.

       -c     Compile  only.  Suppress  the  linking phase of the compilation. Source code files are turned into
              compiled files, but no executable file is produced. This  option  is  useful  to  compile  modules
              separately.

       -cc ccomp
              Use ccomp as the C linker called to build the final executable and as the C compiler for compiling
              .c source files.

       -cclib -llibname
              Pass the -llibname option to the linker. This causes the given C library to  be  linked  with  the
              program.

       -ccopt option
              Pass the given option to the C compiler and linker. For instance, -ccopt -Ldir causes the C linker
              to search for C libraries in directory dir.

       -color mode
              Enable or disable colors in compiler messages (especially warnings  and  errors).   The  following
              modes are supported:

              auto  use  heuristics  to  enable  colors only if the output supports them (an ANSI-compatible tty
              terminal);

              always enable colors unconditionally;

              never disable color output.

              The default setting is auto, and the current heuristic checks that the "TERM" environment variable
              exists and is not empty or "dumb", and that isatty(stderr) holds.

              The  environment  variable  "OCAML_COLOR"  is considered if -color is not provided. Its values are
              auto/always/never as above.

       -compact
              Optimize the produced code for space rather than for time. This results in  smaller  but  slightly
              slower programs. The default is to optimize for speed.

       -config
              Print the version number of ocamlopt(1) and a detailed summary of its configuration, then exit.

       -for-pack module-path
              Generate  an  object file (.cmx and .o files) that can later be included as a sub-module (with the
              given  access  path)  of   a   compilation   unit   constructed   with   -pack.    For   instance,
              ocamlopt -for-pack P -c A.ml  will  generate  a.cmx  and  a.o  files  that  can later be used with
              ocamlopt -pack -o P.cmx a.cmx.

       -g     Add debugging information while compiling and linking. This option is required in order to produce
              stack backtraces when the program terminates on an uncaught exception (see ocamlrun(1)).

       -i     Cause  the  compiler  to  print all defined names (with their inferred types or their definitions)
              when compiling an implementation (.ml file). No compiled files (.cmo and .cmi files) are produced.
              This can be useful to check the types inferred by the compiler. Also, since the output follows the
              syntax of interfaces, it can help in writing an explicit interface (.mli file) for  a  file:  just
              redirect  the  standard  output  of  the compiler to a .mli file, and edit that file to remove all
              declarations of unexported names.

       -I directory
              Add the given directory to the list of directories searched for compiled interface  files  (.cmi),
              compiled  object  code  files  (.cmx), and libraries (.cmxa). By default, the current directory is
              searched first, then the standard library directory. Directories added with -I are searched  after
              the  current  directory, in the order in which they were given on the command line, but before the
              standard library directory. See also option -nostdlib.

              If the given directory starts with +, it is taken relative to the standard library directory.  For
              instance,  -I +compiler-libs  adds  the  subdirectory compiler-libs of the standard library to the
              search path.

       -impl filename
              Compile the file filename as an implementation file, even if its extension is not .ml.

       -inline n
              Set aggressiveness of inlining to n, where n is a positive integer. Specifying -inline 0  prevents
              all  functions  from  being  inlined, except those whose body is smaller than the call site. Thus,
              inlining causes no expansion in code size. The default aggressiveness, -inline 1, allows  slightly
              larger  functions  to  be inlined, resulting in a slight expansion in code size. Higher values for
              the -inline option cause larger and larger functions to become candidate  for  inlining,  but  can
              result in a serious increase in code size.

       -intf filename
              Compile the file filename as an interface file, even if its extension is not .mli.

       -intf-suffix string
              Recognize file names ending with string as interface files (instead of the default .mli).

       -keep-locs
              Keep documentation strings in generated .cmi files.

       -keep-locs
              Keep locations in generated .cmi files.

       -labels
              Labels  are  not ignored in types, labels may be used in applications, and labelled parameters can
              be given in any order.  This is the default.

       -linkall
              Force all modules contained in libraries to be linked in. If this flag is not given,  unreferenced
              modules are not linked in. When building a library (-a flag), setting the -linkall flag forces all
              subsequent links of programs involving that library to link  all  the  modules  contained  in  the
              library.   When  compiling  a  module  (option  -c), setting the -linkall option ensures that this
              module will always be linked if it is put in a library and this library is linked.

       -no-alias-deps
              Do not record dependencies for module aliases.

       -no-app-funct
              Deactivates the applicative behaviour of functors. With  this  option,  each  functor  application
              generates  new types in its result and applying the same functor twice to the same argument yields
              two incompatible structures.

       -noassert
              Do not compile assertion checks.  Note that the  special  form  assert false  is  always  compiled
              because it is typed specially.  This flag has no effect when linking already-compiled files.

       -noautolink
              When  linking  .cmxa  libraries,  ignore  -cclib and -ccopt  options  potentially contained in the
              libraries (if these options were given when building the libraries).  This  can  be  useful  if  a
              library  contains  incorrect  specifications  of  C  libraries  or C options; in this case, during
              linking, set -noautolink and pass the correct C libraries and options on the command line.

       -nodynlink
              Allow the compiler to use some optimizations that are valid only for code that is never dynlinked.

       -nostdlib
              Do not automatically add the standard library directory  the  list  of  directories  searched  for
              compiled  interface  files  (.cmi),  compiled object code files (.cmx), and libraries (.cmxa). See
              also option -I.

       -nolabels
              Ignore non-optional labels in types. Labels cannot be used in applications,  and  parameter  order
              becomes strict.

       -o exec-file
              Specify  the  name of the output file produced by the linker. The default output name is a.out, in
              keeping with the Unix tradition. If the -a option is  given,  specify  the  name  of  the  library
              produced.  If  the -pack option is given, specify the name of the packed object file produced.  If
              the -output-obj option is given, specify the name of the output  file  produced.  If  the  -shared
              option  is  given, specify the name of plugin file produced.  This can also be used when compiling
              an interface or implementation file, without linking, in which case it sets the name of the cmi or
              cmo file, and also sets the module name to the file name up to the first dot.

       -opaque
              When  compiling  a  .mli  interface  file,  this  has the same effect as the -opaque option of the
              bytecode compiler. When compiling a .ml implementation file, this produces  a  .cmx  file  without
              cross-module optimization information, which reduces recompilation on module change.

       -open module
              Opens  the  given module before processing the interface or implementation files. If several -open
              options are given, they are processed in order, just as if  the  statements  open!  module1;;  ...
              open! moduleN;; were added at the top of each file.

       -output-obj
              Cause  the linker to produce a C object file instead of an executable file. This is useful to wrap
              OCaml code as a C library, callable from any C program. The name of the output object file must be
              set with the -o option.  This option can also be used to produce a compiled shared/dynamic library
              (.so extension).

       -p     Generate extra code to write profile information  when  the  program  is  executed.   The  profile
              information  can then be examined with the analysis program gprof(1).  The -p option must be given
              both at compile-time and at link-time.  Linking object files not compiled with -p is possible, but
              results in less precise profiling.

              See the gprof(1) man page for more information about the profiles.

              Full  support for gprof(1) is only available for certain platforms (currently: Intel x86/Linux and
              Alpha/Digital Unix).  On other platforms, the -p option will result in a less precise profile  (no
              call graph information, only a time profile).

       -pack  Build  an  object  file  (.cmx  and  .o  files)  and its associated compiled interface (.cmi) that
              combines the .cmx object files given on the command line, making them appear as sub-modules of the
              output  .cmx  file.   The  name  of  the  output  .cmx file must be given with the -o option.  For
              instance, ocamlopt -pack -o P.cmx A.cmx B.cmx C.cmx generates compiled files P.cmx, P.o and  P.cmi
              describing  a  compilation unit having three sub-modules A, B and C, corresponding to the contents
              of the object files A.cmx, B.cmx and C.cmx.  These contents can be referenced as P.A, P.B and  P.C
              in the remainder of the program.

              The  .cmx  object  files  being  combined  must  have been compiled with the appropriate -for-pack
              option.   In  the  example  above,  A.cmx,  B.cmx  and  C.cmx  must  have   been   compiled   with
              ocamlopt -for-pack P.

              Multiple  levels  of  packing  can  be  achieved by combining -pack with -for-pack.  See The OCaml
              user's manual, chapter "Native-code compilation" for more details.

       -plugin plugin
              Dynamically load the code of the given plugin (a .cmo, .cma or .cmxs file) in  the  compiler.  The
              plugin  must  exist  in  the  same  kind of code as the compiler (ocamlopt.byte must load bytecode
              plugins, while ocamlopt.opt must load native code  plugins),  and  extension  adaptation  is  done
              automatically for .cma files (to .cmxs files if the compiler is compiled in native code).

       -pp command
              Cause the compiler to call the given command as a preprocessor for each source file. The output of
              command is redirected to an intermediate file, which is compiled.  If  there  are  no  compilation
              errors, the intermediate file is deleted afterwards.

       -ppx command
              After  parsing,  pipe  the  abstract  syntax  tree  through  the preprocessor command.  The module
              Ast_mapper(3) implements the external interface of a preprocessor.

       -principal
              Check information path during type-checking, to  make  sure  that  all  types  are  derived  in  a
              principal  way.  All  programs  accepted in -principal mode are also accepted in default mode with
              equivalent types, but different binary signatures.

       -rectypes
              Allow arbitrary recursive types during type-checking.  By default, only recursive types where  the
              recursion  goes through an object type are supported. Note that once you have created an interface
              using this flag, you must use it again for all dependencies.

       -runtime-variant suffix
              Add suffix to the name of the runtime library that will be used by  the  program.   If  OCaml  was
              configured  with  option  -with-debug-runtime,  then  the  d suffix is supported and gives a debug
              version of the runtime.

       -S     Keep the assembly code produced during the compilation. The assembly code for the source file x.ml
              is saved in the file x.s.

       -safe-string
              Enforce the separation between types string and bytes, thereby making strings read-only. This will
              become the default in a future version of OCaml.

       -shared
              Build a plugin (usually .cmxs) that can be dynamically loaded with the Dynlink module. The name of
              the  plugin  must  be  set  with the -o option. A plugin can include a number of OCaml modules and
              libraries, and extra native objects (.o, .a files).  Building native plugins is only supported for
              some  operating  system.  Under  some  systems  (currently, only Linux AMD 64), all the OCaml code
              linked in a plugin must have been compiled without the -nodynlink  flag.  Some  constraints  might
              also  apply  to the way the extra native objects have been compiled (under Linux AMD 64, they must
              contain only position-independent code).

       -short-paths
              When a type is visible under several module-paths, use the shortest one when printing  the  type's
              name in inferred interfaces and error and warning messages.

       -strict-sequence
              The left-hand part of a sequence must have type unit.

       -thread
              Compile  or  link multithreaded programs, in combination with the system threads library described
              in The OCaml user's manual.

       -unboxed-types
              When a type is unboxable (i.e. a record with a single argument  or  a  concrete  datatype  with  a
              single constructor of one argument) it will be unboxed unless annotated with [@@ocaml.boxed].

       -no-unboxed-types
              When  a  type is unboxable  it will be boxed unless annotated with [@@ocaml.unboxed].  This is the
              default.

       -unsafe
              Turn bound checking off for array and string accesses  (the  v.(i)ands.[i]  constructs).  Programs
              compiled  with  -unsafe  are  therefore  faster,  but  unsafe:  anything can happen if the program
              accesses an array or string outside of its bounds. Additionally,  turn  off  the  check  for  zero
              divisor  in  integer  division  and  modulus  operations.   With  -unsafe, an integer division (or
              modulus) by zero can halt the program or continue with an unspecified result instead of raising  a
              Division_by_zero exception.

       -unsafe-string
              Identify  the  types  string and bytes,  thereby  making strings writable. For reasons of backward
              compatibility, this is the default setting for the moment,  but  this  will  change  in  a  future
              version of OCaml.

       -v     Print  the version number of the compiler and the location of the standard library directory, then
              exit.

       -verbose
              Print all external commands before they are executed, in particular invocations of the  assembler,
              C compiler, and linker.

       -version or -vnum
              Print the version number of the compiler in short form (e.g. "3.11.0"), then exit.

       -w warning-list
              Enable,  disable,  or  mark  as  fatal  the  warnings specified by the argument warning-list.  See
              ocamlc(1) for the syntax of warning-list.

       -warn-error warning-list
              Mark as fatal the warnings specified in the argument warning-list.  The compiler will stop with an
              error  when one of these warnings is emitted.  The warning-list has the same meaning as for the -w
              option: a + sign (or an uppercase letter) marks the corresponding warnings as fatal, a - sign  (or
              a  lowercase  letter) turns them back into non-fatal warnings, and a @ sign both enables and marks
              as fatal the corresponding warnings.

              Note: it is not recommended to use the -warn-error option in  production  code,  because  it  will
              almost  certainly  prevent  compiling  your program with later versions of OCaml when they add new
              warnings or modify existing warnings.

              The default setting is -warn-error -a+31 (only warning 31 is fatal).

       -warn-help
              Show the description of all available warning numbers.

       -where Print the location of the standard library, then exit.

       - file Process file as a file name, even if it starts with a dash (-) character.

       -help or --help
              Display a short usage summary and exit.

OPTIONS FOR THE IA32 ARCHITECTURE

       The IA32 code generator (Intel Pentium, AMD Athlon) supports the following additional option:

       -ffast-math
              Use the IA32 instructions to compute trigonometric and exponential functions, instead  of  calling
              the  corresponding  library  routines.   The functions affected are: atan, atan2, cos, log, log10,
              sin, sqrt and tan.  The resulting code runs faster, but the range of supported arguments  and  the
              precision  of  the  result  can be reduced.  In particular, trigonometric operations cos, sin, tan
              have their range reduced to [-2^64, 2^64].

OPTIONS FOR THE AMD64 ARCHITECTURE

       The AMD64 code generator (64-bit versions of  Intel  Pentium  and  AMD  Athlon)  supports  the  following
       additional options:

       -fPIC  Generate position-independent machine code.  This is the default.

       -fno-PIC
              Generate position-dependent machine code.

OPTIONS FOR THE SPARC ARCHITECTURE

       The Sparc code generator supports the following additional options:

       -march=v8
              Generate SPARC version 8 code.

       -march=v9
              Generate SPARC version 9 code.

       The default is to generate code for SPARC version 7, which runs on all SPARC processors.

OPTIONS FOR THE ARM ARCHITECTURE

       The ARM code generator supports the following additional options:

       -farch=armv4|armv5|armv5te|armv6|armv6t2|armv7
              Select the ARM target architecture

       -ffpu=soft|vfpv2|vfpv3-d16|vfpv3
              Select the floating-point hardware

       -fPIC  Generate position-independent machine code.

       -fno-PIC
              Generate position-dependent machine code.  This is the default.

       -fthumb
              Enable Thumb/Thumb-2 code generation

       -fno-thumb
              Disable Thumb/Thumb-2 code generation

       The  default  values  for  target  architecture, floating-point hardware and thumb usage were selected at
       configure-time when building ocamlopt itself. This configuration can be inspected using ocamlopt -config.
       Target  architecture  depends on the "model" setting, while floating-point hardware and thumb support are
       determined from the ABI setting in "system" ( linux_eabiorlinux_eabihf).

SEE ALSO

       ocamlc(1).
       The OCaml user's manual, chapter "Native-code compilation".

                                                                                                     OCAMLOPT(1)