NAME

       scanimage - scan an image

SYNOPSIS

       scanimage   [-d|--device-name  dev]  [--format  format]  [-i|--icc-profile  profile]  [-L|--list-devices]
       [-f|--formatted-device-list format] [-b|--batch [=format]] [--batch-start  start]  [--batch-count  count]
       [--batch-increment   increment]  [--batch-double]  [--accept-md5-only]  [-p|--progress]  [-n|--dont-scan]
       [-T|--test]  [-A|--all-options]  [-h|--help]  [-v|--verbose]  [-B|--buffer-size  [=size]]  [-V|--version]
       [device-specific-options]

DESCRIPTION

       scanimage  is  a  command-line interface to control image acquisition devices such as flatbed scanners or
       cameras.  The device is controlled via command-line options.  After  command-line  processing,  scanimage
       normally  proceeds  to  acquire an image.  The image data is written to standard output in one of the PNM
       (portable aNyMaP) formats (PBM for black-and-white images, PGM for grayscale images, and  PPM  for  color
       images),  TIFF  format  (black-and-white,  grayscale  or  color),  PNG format, or JPEG format.  scanimage
       accesses image acquisition devices through the SANE (Scanner Access Now  Easy)  interface  and  can  thus
       support  any  device  for which there exists a SANE backend (try apropos sane- to get a list of available
       backends).

EXAMPLES

       To get a list of devices:

         scanimage -L

       To scan with default settings to the file image.pnm:

         scanimage >image.pnm

       To scan 100x100 mm to the file image.tiff (-x and -y may not be available with all devices):

         scanimage -x 100 -y 100 --format=tiff >image.tiff

       To print all available options:

         scanimage -h

OPTIONS

       Remark: Parameter are defined by the backends. So are --mode Gray and --mode Grayscale  in  use.   Please
       read the backend documentation first.

       Parameters  are  separated  by  a  blank from single-character options (e.g.  -d epson) and by a "=" from
       multi-character options (e.g. --device-name=epson).

       The -d or --device-name options  must  be  followed  by  a  SANE  device-name  like  `epson:/dev/sg0'  or
       `hp:/dev/usbscanner0'.   A  (partial)  list  of available devices can be obtained with the --list-devices
       option (see below).  If no device-name is specified explicitly, scanimage reads a  device-name  from  the
       environment  variable  SANE_DEFAULT_DEVICE.   If this variable is not set, scanimage will attempt to open
       the first available device.

       The --format format option selects how image data is written to standard  output.   format  can  be  pnm,
       tiff, png, or jpeg.  If --format is not used, PNM is written.

       The -i or --icc-profile option is used to include an ICC profile into a TIFF file.

       The -L or --list-devices option requests a (partial) list of devices that are available.  The list is not
       complete since some devices may be available, but are not listed in any of the configuration files (which
       are  typically  stored  in directory @CONFIGDIR@).  This is particularly the case when accessing scanners
       through the network.  If a device is not listed in a configuration file, the only way to access it is  by
       its  full  device  name.  You may need to consult your system administrator to find out the names of such
       devices.

       The -f or --formatted-device-list option works similar to --list-devices, but requires a  format  string.
       scanimage  replaces  the  placeholders  %d  %v %m %t %i %n with the device name, vendor name, model name,
       scanner type, an index number and newline respectively. The command

              scanimage -f  scanner number %i device %d is a %t, model %m, produced by %v 

       will produce something like:

              scanner number 0  device sharp:/dev/sg1 is  a  flatbed scanner,  model  JX250  SCSI,  produced  by
              SHARP

       The  --batch*  options  provide  the  features  for  scanning  documents using document feeders.  --batch
       [format] is used to specify the format of the filename that each page will be written to.  Each  page  is
       written  out  to  a  single file.  If format is not specified, the default of out%d.pnm (or out%d.tif for
       --format tiff, out%d.png for --format png or out%d.jpg for -- format jpeg) will be used.  format is given
       as  a  printf  style  string  with one integer parameter.  --batch-start start selects the page number to
       start naming files with. If this option is not given, the counter will start at 1.   --batch-count  count
       specifies  the  number of pages to attempt to scan.  If not given, scanimage will continue scanning until
       the scanner returns a state other than OK.  Not all scanners with document feeders signal when the ADF is
       empty,  use this command to work around them.  With --batch-increment increment you can change the amount
       that the number in the filename is incremented by.  Generally this is used when you are scanning  double-
       sided  documents  on  a  single-sided  document  feeder.   A  specific  command  is provided to aid this:
       --batch-double will automatically set the increment to 2.  --batch-prompt will ask  for  pressing  RETURN
       before  scanning  a  page.  This  can  be  used for scanning multiple pages without an automatic document
       feeder.

       The --accept-md5-only option only accepts user authorization requests that support MD5 security. The SANE
       network daemon (saned) is capable of doing such requests. See saned(8).

       The  -p  or  --progress option requests that scanimage prints a progress counter. It shows how much image
       data of the current image has already been received by scanimage (in percent).

       The -n or --dont-scan option requests that scanimage only sets the  options  provided  by  the  user  but
       doesn't  actually  perform  a  scan.  This  option  can  be  used to e.g. turn off the scanner's lamp (if
       supported by the backend).

       The -T or --test option requests that scanimage performs a few simple  sanity  tests  to  make  sure  the
       backend  works  as  defined  by  the  SANE API (in particular the sane_read function is exercised by this
       test).

       The -A or --all-options option requests that scanimage lists all available options exposed  the  backend,
       including button options.  The information is printed on standard output and no scan will be done.

       The  -h or --help options request help information.  The information is printed on standard output and in
       this case, no attempt will be made to acquire an image.

       The -v or --verbose options increase the verbosity of the operation of  scanimage.   The  option  may  be
       specified repeatedly, each time increasing the verbosity level.

       The  -B  option  without  argument changes the input buffer size from the default 32KB to 1MB.  For finer
       grained control, use --buffer-size= followed by the number of KB.

       The -V or --version option requests that scanimage prints the  program  and  package  name,  the  version
       number  of  the SANE distribution that it came with and the version of the backend that it loads. Usually
       that's the dll backend. If more information about the version numbers of the backends are necessary,  the
       DEBUG variable for the dll backend can be used. Example: SANE_DEBUG_DLL=3 scanimage -L.

       As  you  might  imagine,  much of the power of scanimage comes from the fact that it can control any SANE
       backend.  Thus, the exact set of command-line options depends on the capabilities of the selected device.
       To see the options for a device named dev, invoke scanimage via a command-line of the form:

              scanimage --help --device-name dev

       The  documentation  for  the  device-specific  options  printed  by  --help  is best explained with a few
       examples:

        -l 0..218mm [0]
           Top-left x position of scan area.

              The description above shows that option -l expects an option value in the range from 0 to 218  mm.
              The  value  in  square  brackets  indicates  that  the current option value is 0 mm. Most backends
              provide similar geometry options for top-left y position (-t), width (-x) and height of  scan-area
              (-y).

        --brightness -100..100% [0]
           Controls the brightness of the acquired image.

              The  description  above  shows  that option --brightness expects an option value in the range from
              -100 to 100 percent.  The value in square brackets indicates that the current option  value  is  0
              percent.

        --default-enhancements
           Set default values for enhancement controls.

              The  description above shows that option --default-enhancements has no option value.  It should be
              thought of as having an immediate effect at the point of the command-line  at  which  it  appears.
              For  example,  since  this  option resets the --brightness option, the option-pair --brightness 50
              --default-enhancements would effectively be a no-op.

        --mode Lineart|Gray|Color [Gray]
           Selects the scan mode (e.g., lineart or color).

              The description above shows that option --mode accepts an argument that must be one of the strings
              Lineart,  Gray,  or Color.  The value in the square bracket indicates that the option is currently
              set to Gray.  For convenience, it is legal to abbreviate the string values as long as they  remain
              unique.  Also, the case of the spelling doesn't matter.  For example, option setting --mode col is
              identical to --mode Color.

        --custom-gamma[=(yes|no)] [inactive]
           Determines whether a builtin or a custom gamma-table
           should be used.

              The description above shows that option --custom-gamma expects either no  option  value,  a  "yes"
              string,  or a "no" string.  Specifying the option with no value is equivalent to specifying "yes".
              The value in square-brackets indicates  that  the  option  is  not  currently  active.   That  is,
              attempting  to  set  the  option  would  result in an error message.  The set of available options
              typically depends on the settings of other options.  For example, the --custom-gamma  table  might
              be active only when a grayscale or color scan-mode has been requested.

              Note  that  the --help option is processed only after all other options have been processed.  This
              makes it possible to see the option settings for a particular mode by specifying  the  appropriate
              mode-options along with the --help option.  For example, the command-line:

              scanimage --help --mode color

              would print the option settings that are in effect when the color-mode is selected.

        --gamma-table 0..255,...
           Gamma-correction table.  In color mode this option
           equally affects the red, green, and blue channels
           simultaneously (i.e., it is an intensity gamma table).

              The  description  above shows that option --gamma-table expects zero or more values in the range 0
              to 255.  For example, a legal value for this option would be "3,4,5,6,7,8,9,10,11,12".  Since it's
              cumbersome to specify long vectors in this form, the same can be expressed by the abbreviated form
              "[0]3-[9]12".  What this means is that the first vector element is set to 3, the 9-th  element  is
              set  to  12  and  the  values  in between are interpolated linearly.  Of course, it is possible to
              specify multiple such linear segments.  For example, "[0]3-[2]3-[6]7,[7]10-[9]6" is equivalent  to
              "3,3,3,4,5,6,7,10,8,6".   The  program  gamma4scanimage  can be used to generate such gamma tables
              (see gamma4scanimage(1) for details).

        --filename <string> [/tmp/input.ppm]
           The filename of the image to be loaded.

              The description above is an example of an option that  takes  an  arbitrary  string  value  (which
              happens  to  be  a filename).  Again, the value in brackets show that the option is current set to
              the filename /tmp/input.ppm.

ENVIRONMENT

       SANE_DEFAULT_DEVICE
              The default device-name.

FILES

       @CONFIGDIR@
              This directory holds various configuration files.  For details, please refer to the  manual  pages
              listed below.

       ~/.sane/pass
              This file contains lines of the form

              user:password:resource

              scanimage uses this information to answer user authorization requests automatically. The file must
              have  0600  permissions  or  stricter.  You  should  use  this  file  in  conjunction   with   the
              --accept-md5-only  option to avoid server-side attacks. The resource may contain any character but
              is limited to 127 characters.

SEE ALSO

       sane(7), gamma4scanimage(1), xscanimage(1),  xcam(1),  xsane(1),  scanadf(1),  sane-dll(5),  sane-net(5),
       sane-"backendname"(5)

AUTHOR

       David  Mosberger,  Andreas  Beck,  Gordon Matzigkeit, Caskey Dickson, and many others.  For questions and
       comments contact the sane-devel mailinglist (see http://www.sane-project.org/mailing-lists.html).

BUGS

       For vector options, the help output currently has no indication as to how many  elements  a  vector-value
       should have.

@PACKAGEVERSION@                                   10 Jul 2008                                      scanimage(1)