Provided by: libsystemd-dev_237-3ubuntu10.57_amd64 bug

NAME

       sd_journal_get_data, sd_journal_enumerate_data, sd_journal_restart_data,
       SD_JOURNAL_FOREACH_DATA, sd_journal_set_data_threshold, sd_journal_get_data_threshold -
       Read data fields from the current journal entry

SYNOPSIS

       #include <systemd/sd-journal.h>

       int sd_journal_get_data(sd_journal *j, const char *field, const void **data,
                               size_t *length);

       int sd_journal_enumerate_data(sd_journal *j, const void **data, size_t *length);

       void sd_journal_restart_data(sd_journal *j);

       SD_JOURNAL_FOREACH_DATA(sd_journal *j, const void *data, size_t length);

       int sd_journal_set_data_threshold(sd_journal *j, size_t sz);

       int sd_journal_get_data_threshold(sd_journal *j, size_t *sz);

DESCRIPTION

       sd_journal_get_data() gets the data object associated with a specific field from the
       current journal entry. It takes four arguments: the journal context object, a string with
       the field name to request, plus a pair of pointers to pointer/size variables where the
       data object and its size shall be stored in. The field name should be an entry field name.
       Well-known field names are listed in systemd.journal-fields(7). The returned data is in a
       read-only memory map and is only valid until the next invocation of sd_journal_get_data()
       or sd_journal_enumerate_data(), or the read pointer is altered. Note that the data
       returned will be prefixed with the field name and '='. Also note that, by default, data
       fields larger than 64K might get truncated to 64K. This threshold may be changed and
       turned off with sd_journal_set_data_threshold() (see below).

       sd_journal_enumerate_data() may be used to iterate through all fields of the current
       entry. On each invocation the data for the next field is returned. The order of these
       fields is not defined. The data returned is in the same format as with
       sd_journal_get_data() and also follows the same life-time semantics.

       sd_journal_restart_data() resets the data enumeration index to the beginning of the entry.
       The next invocation of sd_journal_enumerate_data() will return the first field of the
       entry again.

       Note that the SD_JOURNAL_FOREACH_DATA() macro may be used as a handy wrapper around
       sd_journal_restart_data() and sd_journal_enumerate_data().

       Note that these functions will not work before sd_journal_next(3) (or related call) has
       been called at least once, in order to position the read pointer at a valid entry.

       sd_journal_set_data_threshold() may be used to change the data field size threshold for
       data returned by sd_journal_get_data(), sd_journal_enumerate_data() and
       sd_journal_enumerate_unique(). This threshold is a hint only: it indicates that the client
       program is interested only in the initial parts of the data fields, up to the threshold in
       size — but the library might still return larger data objects. That means applications
       should not rely exclusively on this setting to limit the size of the data fields returned,
       but need to apply an explicit size limit on the returned data as well. This threshold
       defaults to 64K by default. To retrieve the complete data fields this threshold should be
       turned off by setting it to 0, so that the library always returns the complete data
       objects. It is recommended to set this threshold as low as possible since this relieves
       the library from having to decompress large compressed data objects in full.

       sd_journal_get_data_threshold() returns the currently configured data field size
       threshold.

RETURN VALUE

       sd_journal_get_data() returns 0 on success or a negative errno-style error code. If the
       current entry does not include the specified field, -ENOENT is returned. If
       sd_journal_next(3) has not been called at least once, -EADDRNOTAVAIL is returned.
       sd_journal_enumerate_data() returns a positive integer if the next field has been read, 0
       when no more fields are known, or a negative errno-style error code.
       sd_journal_restart_data() returns nothing.  sd_journal_set_data_threshold() and
       sd_journal_get_threshold() return 0 on success or a negative errno-style error code.

NOTES

       The sd_journal_get_data(), sd_journal_enumerate_data(), sd_journal_restart_data(),
       sd_journal_set_data_threshold() and sd_journal_get_data_threshold() interfaces are
       available as a shared library, which can be compiled and linked to with the
       libsystemd pkg-config(1) file.

EXAMPLES

       See sd_journal_next(3) for a complete example how to use sd_journal_get_data().

       Use the SD_JOURNAL_FOREACH_DATA macro to iterate through all fields of the current journal
       entry:

           ...
           int print_fields(sd_journal *j) {
             const void *data;
             size_t length;
             SD_JOURNAL_FOREACH_DATA(j, data, length)
               printf("%.*s\n", (int) length, data);
           }
           ...

SEE ALSO

       systemd(1), systemd.journal-fields(7), sd-journal(3), sd_journal_open(3),
       sd_journal_next(3), sd_journal_get_realtime_usec(3), sd_journal_query_unique(3)