Provided by: libsane-common_1.0.27-1~experimental3ubuntu2.4_all
NAME
sane-coolscan - SANE backend for Nikon film-scanners
ABOUT THIS FILE
This file is a short description of the coolscan-backend for sane!
DESCRIPTION
The sane-coolscan library implements a SANE backend that provides the interface to the following Nikon Coolscan Film scanners: Nikon LS20, LS30, LS1000, LS2000. Even though the backend has worked for a number of people, there are still some problems, especially in combination with some SCSI card/drivers (AHA-1505/aha152x.o) and the autofocus command. You should consider this backend 'alpha' and be careful when using it the first time.
CONFIGURATION
The configuration file for this backend resides in @CONFIGDIR@/coolscan.conf. Its contents is a list of device names that correspond to Nikon Coolscan scanners. Empty lines and lines starting with a hash mark (#) are ignored. A sample configuration file is shown below: #scsi Vendor Model Type scsi Nikon * Scanner /dev/scanner The special device name must be a generic SCSI device or a symlink to such a device. To find out to which device your scanner is assigned and how you have to set the permissions of that device, have a look at sane-scsi.
SCSI ADAPTER TIPS
Some SCSI-adapters and low-level SCSI drivers do not work correctly with this backend and the Coolscan scanners. These systems hang when the autofocus command is send to the Scanner. To see a list of which card/driver combinations work or don't work have a look at: http://andreas.rick.free.fr/sane/autofocus.html.
FILES
The backend configuration file: @CONFIGDIR@/coolscan.conf The static library implementing this backend: @LIBDIR@/libsane-coolscan.a The shared library implementing this backend: @LIBDIR@/libsane-coolscan.so (present on systems that support dynamic loading)
ENVIRONMENT
SANE_DEBUG_COOLSCAN If the library was compiled with debug support enabled, this environment variable controls the debug level for this backend. E.g., a value of 128 requests all debug output to be printed. Smaller levels reduce verbosity: SANE_DEBUG_COOLSCAN values Examples: on bash: export SANE_DEBUG_COOLSCAN=8 on csh: setenv SANE_DEBUG_COOLSCAN 8
BUGS
The autofocus command does not work with some SCSI card/driver combinations The gamma table is not implemented for the LS1000 yet. The dust-removal is not working yet
SEE ALSO
http://andreas.rick.free.fr/sane/ The homepage of this backend http://www.sema.be/coolscan/ The original version of the coolscan backend by Didier sane(7), sane-scsi(5)
THANKS TO
Didier Carlier - For writing the original Coolscan backend (without it I would not have started this) Oliver Rauch - For adapting xsane so quickly to the infrared stuff. All the other people working on SANE.
AUTHOR
Andreas Rick
EMAIL-CONTACT
andreas.rick@free.fr @PACKAGEVERSION@ 13 Jul 2008 sane-coolscan(5)