bionic (8) ipmi-sensors.8.gz

Provided by: freeipmi-tools_1.4.11-1.1ubuntu4.1_amd64 bug

NAME

       ipmi-sensors - display IPMI sensor information

SYNOPSIS

       ipmi-sensors [OPTION...]

DESCRIPTION

       Ipmi-sensors  displays  current  readings  of  sensors  and sensor data repository (SDR) information. The
       default display outputs each sensor's record id, sensor  name,  sensor  type  name,  sensor  reading  (if
       appropriate),  and  the  current  sensor  event.  More verbose information can be found using the verbose
       options specified below.  Ipmi-sensors does not inform the user if a problem  exists  with  a  particular
       sensor  because  sensor  readings  and  events  are  not  analyzed  by default. Users may wish to use the
       --output-sensor-state option to output the analyzed sensor state.  Some sensors may have a sensor reading
       or  sensor  event  of  "N/A"  if  the information is unavailable. This is typical of a sensor that is not
       enabled or not owned by a BMC. Please see --bridge-sensors option below to deal with sensors not owned by
       a  BMC.  Sensors  may  output  a  sensor event of "Unknown" if the sensor reading cannot be read. This is
       typical of a sensor that is busy or a reading that cannot be calculated. If sensors report  "Unrecognized
       State",  it  is  indicative  of  an  unknown  sensor  type,  typically  an  OEM sensor. If the sensor OEM
       interpretation is available, the --interpret-oem-data may be able to report the appropriate sensor state.
       Sensors  need  not  always  report  a sensor event. When a sensor event is not present, "OK" is typically
       reported.

       Listed below are general IPMI options, tool specific options, trouble  shooting  information,  workaround
       information,  examples,  and known issues. For a general introduction to FreeIPMI please see freeipmi(7).
       To perform  IPMI  sensor  configuration,  please  see  ipmi-config(8).   To  perform  some  advanced  SDR
       management, please see bmc-device(8).

GENERAL OPTIONS

       The  following  options are general options for configuring IPMI communication and executing general tool
       commands.

       -D IPMIDRIVER, --driver-type=IPMIDRIVER
              Specify the driver type to use instead of  doing  an  auto  selection.   The  currently  available
              outofband  drivers  are  LAN  and  LAN_2_0,  which perform IPMI 1.5 and IPMI 2.0 respectively. The
              currently available inband drivers are KCS, SSIF, OPENIPMI, SUNBMC, and INTELDCMI.

       --disable-auto-probe
              Do not probe in-band IPMI devices for default settings.

       --driver-address=DRIVER-ADDRESS
              Specify the in-band driver address to be used instead of the probed value.  DRIVER-ADDRESS  should
              be prefixed with "0x" for a hex value and '0' for an octal value.

       --driver-device=DEVICE
              Specify the in-band driver device path to be used instead of the probed path.

       --register-spacing=REGISTER-SPACING
              Specify  the  in-band  driver  register  spacing instead of the probed value. Argument is in bytes
              (i.e. 32bit register spacing = 4)

       --target-channel-number=CHANNEL-NUMBER
              Specify the in-band driver target channel number to send IPMI requests to.

       --target-slave-address=SLAVE-ADDRESS
              Specify the in-band driver target slave number to send IPMI requests to.

       -h IPMIHOST1,IPMIHOST2,..., --hostname=IPMIHOST1[:PORT],IPMIHOST2[:PORT],...
              Specify the remote host(s) to communicate with. Multiple hostnames may be separated  by  comma  or
              may  be  specified  in  a  range  format;  see  HOSTRANGED  SUPPORT below. An optional port can be
              specified with each host, which may be useful in port forwarding or similar situations.

       -u USERNAME, --username=USERNAME
              Specify the username to use when authenticating with the remote host.  If not  specified,  a  null
              (i.e.  anonymous) username is assumed. The user must have atleast OPERATOR privileges in order for
              this tool to operate fully.

       -p PASSWORD, --password=PASSWORD
              Specify the password to use when authenticationg with the remote host.  If not specified,  a  null
              password is assumed. Maximum password length is 16 for IPMI 1.5 and 20 for IPMI 2.0.

       -P, --password-prompt
              Prompt for password to avoid possibility of listing it in process lists.

       -k K_G, --k-g=K_G
              Specify  the  K_g  BMC  key  to  use when authenticating with the remote host for IPMI 2.0. If not
              specified, a null key is assumed. To input the key in hexadecimal form,  prefix  the  string  with
              '0x'. E.g., the key 'abc' can be entered with the either the string 'abc' or the string '0x616263'

       -K, --k-g-prompt
              Prompt for k-g to avoid possibility of listing it in process lists.

       --session-timeout=MILLISECONDS
              Specify  the  session  timeout in milliseconds. Defaults to 20000 milliseconds (20 seconds) if not
              specified.

       --retransmission-timeout=MILLISECONDS
              Specify the packet retransmission timeout  in  milliseconds.  Defaults  to  1000  milliseconds  (1
              second) if not specified. The retransmission timeout cannot be larger than the session timeout.

       -a AUTHENTICATION-TYPE, --authentication-type=AUTHENTICATION-TYPE
              Specify  the IPMI 1.5 authentication type to use. The currently available authentication types are
              NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5. Defaults to MD5 if not specified.

       -I CIPHER-SUITE-ID, --cipher-suite-id=CIPHER-SUITE-ID
              Specify the IPMI  2.0  cipher  suite  ID  to  use.  The  Cipher  Suite  ID  identifies  a  set  of
              authentication,  integrity,  and confidentiality algorithms to use for IPMI 2.0 communication. The
              authentication algorithm identifies  the  algorithm  to  use  for  session  setup,  the  integrity
              algorithm  identifies  the algorithm to use for session packet signatures, and the confidentiality
              algorithm identifies the algorithm to use for payload encryption. Defaults to cipher suite ID 3 if
              not specified. The following cipher suite ids are currently supported:

              0 - Authentication Algorithm = None; Integrity Algorithm = None; Confidentiality Algorithm = None

              1  - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm = None; Confidentiality Algorithm =
              None

              2 - Authentication Algorithm = HMAC-SHA1;  Integrity  Algorithm  =  HMAC-SHA1-96;  Confidentiality
              Algorithm = None

              3  -  Authentication  Algorithm  =  HMAC-SHA1; Integrity Algorithm = HMAC-SHA1-96; Confidentiality
              Algorithm = AES-CBC-128

              6 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = None; Confidentiality  Algorithm  =
              None

              7  -  Authentication  Algorithm  =  HMAC-MD5;  Integrity Algorithm = HMAC-MD5-128; Confidentiality
              Algorithm = None

              8 - Authentication Algorithm =  HMAC-MD5;  Integrity  Algorithm  =  HMAC-MD5-128;  Confidentiality
              Algorithm = AES-CBC-128

              11 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = MD5-128; Confidentiality Algorithm
              = None

              12 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = MD5-128; Confidentiality Algorithm
              = AES-CBC-128

              15 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm = None; Confidentiality Algorithm
              = None

              16  -  Authentication  Algorithm   =   HMAC-SHA256;   Integrity   Algorithm   =   HMAC_SHA256_128;
              Confidentiality Algorithm = None

              17   -   Authentication   Algorithm   =   HMAC-SHA256;   Integrity  Algorithm  =  HMAC_SHA256_128;
              Confidentiality Algorithm = AES-CBC-128

       -l PRIVILEGE-LEVEL, --privilege-level=PRIVILEGE-LEVEL
              Specify the privilege level to be  used.  The  currently  available  privilege  levels  are  USER,
              OPERATOR, and ADMIN. Defaults to OPERATOR if not specified.

       --config-file=FILE
              Specify an alternate configuration file.

       -W WORKAROUNDS, --workaround-flags=WORKAROUNDS
              Specify  workarounds  to vendor compliance issues. Multiple workarounds can be specified separated
              by commas. A special command line flag of "none", will indicate no workarounds (may be useful  for
              overriding configured defaults). See WORKAROUNDS below for a list of available workarounds.

       --debug
              Turn on debugging.

       -?, --help
              Output a help list and exit.

       --usage
              Output a usage message and exit.

       -V, --version
              Output the program version and exit.

IPMI-SENSORS OPTIONS

       The following options are specific to Ipmi-sensors.

       -v, --verbose
              Output verbose sensor output. This option will output additional information about sensors such as
              thresholds, ranges, numbers, and event/reading type codes.

       -vv    Output very verbose sensor output. This option will output more additional  information  than  the
              verbose option such as information about events, other sensor types, and oem sensors.

       -i, --sdr-info
              Show sensor data repository (SDR) information

       -q, --quiet-readings
              Do  not output sensor reading values by default. This option is particularly useful if you want to
              use hostranged output across a cluster and want to consolidate the output.

       -r RECORD-IDS-LIST, --record-ids=RECORD-IDS-LIST
              Specify sensors to show by record id. Multiple record ids can be separated by commas or spaces. If
              both  --record-ids  and  --sensor-types  are  specified,  --record-ids takes precedence. A special
              command line record id of "all", will indicate all record ids should be shown (may be  useful  for
              overriding configured defaults).

       -R RECORD-IDS-LIST, --exclude-record-ids=RECORD-IDS-LIST
              Specify  sensors  to  not  show  by  record  id. Multiple record ids can be separated by commas or
              spaces. A special command line record id of "none", will indicate no record ids should be excluded
              (may be useful for overriding configured defaults).

       -t SENSOR-TYPE-LIST, --sensor-types=SENSOR-TYPE-LIST
              Specify  sensor types to show outputs for. Multiple types can be separated by commas or spaces. If
              both --record-ids and --sensor-types are specified,  --record-ids  takes  precedence.   A  special
              command  line type of "all", will indicate all types should be shown (may be useful for overriding
              configured defaults). Users may specify sensor types by string (see --list-sensor-types below)  or
              by number (decimal or hex).

       -T SENSOR-TYPE-LIST, --exclude-sensor-types=SENSOR-TYPE-LIST
              Specify  sensor types to not show outputs for. Multiple types can be eparated by commas or spaces.
              A special command line type of "none", will indicate no types should be excluded  (may  be  useful
              for   overriding   configured   defaults).   Users   may  specify  sensor  types  by  string  (see
              --list-sensor-types below) or by number (decimal or hex).

       -L, --list-sensor-types
              List sensor types.

       -b, --bridge-sensors
              By default, sensors readings are not attempted for sensors on  non-BMC  owners.  By  setting  this
              option,  sensor  requests can be bridged to non-BMC owners to obtain sensor readings. Bridging may
              not work on some interfaces/driver types.

       --shared-sensors
              Some sensors share the same sensor data record (SDR). This is typically utilized for system  event
              log  (SEL)  entries  and not for sensor readings. However, there may be some motherboards in which
              this format is utilized for multiple active sensors, or the user simply has interest in seeing the
              permutation of entries shared by a SDR entry. By setting this option, each sensor number shared by
              a record will be iterated over and output.

       --interpret-oem-data
              Attempt to interpret OEM data, such as event data, sensor readings, or general extra info, etc. If
              an  OEM  interpretation is not available, the default output will be generated. Correctness of OEM
              interpretations cannot be guaranteed due to potential changes OEM vendors may  make  in  products,
              firmware, etc. See OEM INTERPRETATION below for confirmed supported motherboard interpretations.

       --ignore-not-available-sensors
              Ignore not-available (i.e. N/A) sensors in output.

       --ignore-unrecognized-events
              Ignore  unrecognized  sensor  events.  This will suppress output of unrecognized events, typically
              shown as 'Unrecognized Event = XXXXh' in output. In addition, unrecognized events will be  ignored
              when calculating sensor state with --output-sensor-state below.

       --output-event-bitmask
              Output event bitmask value instead of the string representation.

       --output-sensor-state
              Output  sensor  state  in output. This will add an additional output reporting if a sensor is in a
              NOMINAL, WARNING, or CRITICAL state.  The sensor state  is  an  interpreted  value  based  on  the
              current  sensor  event.  The sensor state interpretations are determined by the configuration file
              /etc/freeipmi//freeipmi_interpret_sensor.conf.   See  freeipmi_interpret_sensor.conf(5)  for  more
              information.   This  option  gives  identical  output  to  the  sensor  state previously output by
              ipmimonitoring(8).

       --sensor-state-config-file=FILE
              Specify an alternate sensor state configuration file. Option ignored if --output-sensor-state  not
              specified.

       --entity-sensor-names
              Output  sensor  names prefixed with their entity id and instance number when appropriate. This may
              be necessary on some motherboards to help identify what sensors are referencing.  For  example,  a
              motherboard  may  have  multiple  sensors named 'TEMP'. The entity id and instance number may help
              clarify which sensor refers to "Processor 1" vs. "Processor 2".

       --output-sensor-thresholds
              Output sensor thresholds in output. This will add columns to the default  output  for  lower  non-
              recoverable,  lower  critical,  lower  non-critical, upper non-critical, upper critical, and upper
              non-recoverable thresholds.

       --no-sensor-type-output
              Do not show sensor type output for each entry. On many systems, the sensor type  is  redundant  to
              the name of the sensor. This can especially be true if --entity-sensor-names is specified.  If the
              sensor name is sufficient, or if the sensor type is of no interest to the user, this option can be
              specified to condense output.

       --comma-separated-output
              Output fields in comma separated format.

       --no-header-output
              Do not output column headers. May be useful in scripting.

       --non-abbreviated-units
              Output  non-abbreviated  units  (e.g.  'Amps'  instead of 'A'). May aid in disambiguation of units
              (e.g. 'C' for Celsius or Coulombs).

       --legacy-output
              Output in legacy format. Newer options may not be applicable to legacy output.

       --ipmimonitoring-legacy-output
              Output legacy format of legacy ipmimonitoring tool. Newer options may not be applicable to  legacy
              output.

SDR CACHE OPTIONS

       This  tool  requires  access to the sensor data repository (SDR) cache for general operation. By default,
       SDR data will be downloaded and cached on the local machine. The  following  options  apply  to  the  SDR
       cache.

       -f, --flush-cache
              Flush  a cached version of the sensor data repository (SDR) cache. The SDR is typically cached for
              faster subsequent access. However, it may need to be flushed and re-generated if the SDR has  been
              updated on a system.

       -Q, --quiet-cache
              Do not output information about cache creation/deletion. May be useful in scripting.

       --sdr-cache-recreate
              If  the  SDR  cache  is  out of date or invalid, automatically recreate the sensor data repository
              (SDR) cache. This option may be useful for scripting purposes.

       --sdr-cache-file=FILE
              Specify a specific sensor data repository (SDR) cache file to be stored  or  read  from.  If  this
              option  is  used  when  multiple hosts are specified, the same SDR cache file will be used for all
              hosts.

       --sdr-cache-directory=DIRECTORY
              Specify an alternate directory for sensor data repository (SDR) caches to be stored or read  from.
              Defaults to the home directory if not specified.

TIME OPTIONS

       By  IPMI  definition, all IPMI times and timestamps are stored in localtime. However, in many situations,
       the timestamps will not be stored in localtime. Whether or not a system truly stored  the  timestamps  in
       localtime  varies on many factors, such as the vendor, BIOS, and operating system.  The following options
       will allow the user to adjust the interpretation of the stored timestamps and how they should be output.

       --utc-to-localtime
              Assume all times are reported in UTC time and convert the time to localtime before being output.

       --localtime-to-utc
              Convert all localtime timestamps to UTC before being output.

       --utc-offset=SECONDS
              Specify a specific UTC offset in seconds to be added to timestamps.  Value can range  from  -86400
              to 86400 seconds. Defaults to 0.

HOSTRANGED OPTIONS

       The  following  options  manipulate  hostranged  output.  See  HOSTRANGED  SUPPORT  below  for additional
       information on hostranges.

       -B, --buffer-output
              Buffer hostranged output. For each node, buffer standard output until the node has  completed  its
              IPMI  operation.  When  specifying this option, data may appear to output slower to the user since
              the the entire IPMI operation must complete before any data can be output.  See HOSTRANGED SUPPORT
              below for additional information.

       -C, --consolidate-output
              Consolidate  hostranged  output.  The  complete  standard output from every node specified will be
              consolidated so that nodes with identical output are not output twice. A header  will  list  those
              nodes with the consolidated output. When this option is specified, no output can be seen until the
              IPMI operations to all nodes has completed. If the user breaks  out  of  the  program  early,  all
              currently  consolidated  output  will  be  dumped.  See  HOSTRANGED  SUPPORT  below for additional
              information.

       -F NUM, --fanout=NUM
              Specify multiple host fanout. A "sliding window" (or fanout) algorithm is used for  parallel  IPMI
              communication  so that slower nodes or timed out nodes will not impede parallel communication. The
              maximum number of threads available at the same time is limited by the fanout. The default is 64.

       -E, --eliminate
              Eliminate hosts determined as undetected by ipmidetect.  This attempts to remove the common  issue
              of  hostranged  execution  timing  out  due to several nodes being removed from service in a large
              cluster. The ipmidetectd daemon must be running on the node executing the command.

       --always-prefix
              Always prefix output, even if only one host is specified or communicating in-band. This option  is
              primarily useful for scripting purposes. Option will be ignored if specified with the -C option.

HOSTRANGED SUPPORT

       Multiple  hosts can be input either as an explicit comma separated lists of hosts or a range of hostnames
       in the general form: prefix[n-m,l-k,...], where n < m and l < k,  etc.  The  later  form  should  not  be
       confused  with  regular  expression character classes (also denoted by []). For example, foo[19] does not
       represent foo1 or foo9, but rather represents a degenerate range: foo19.

       This range syntax is meant only as a convenience on  clusters  with  a  prefixNN  naming  convention  and
       specification  of  ranges  should not be considered necessary -- the list foo1,foo9 could be specified as
       such, or by the range foo[1,9].

       Some examples of range usage follow:
           foo[01-05] instead of foo01,foo02,foo03,foo04,foo05
           foo[7,9-10] instead of foo7,foo9,foo10
           foo[0-3] instead of foo0,foo1,foo2,foo3

       As a reminder to the reader, some shells  will  interpret  brackets  ([  and  ])  for  pattern  matching.
       Depending on your shell, it may be necessary to enclose ranged lists within quotes.

       When  multiple hosts are specified by the user, a thread will be executed for each host in parallel up to
       the configured fanout (which can be adjusted via the -F option). This will allow communication  to  large
       numbers of nodes far more quickly than if done in serial.

       By  default,  standard output from each node specified will be output with the hostname prepended to each
       line. Although this output is readable in  many  situations,  it  may  be  difficult  to  read  in  other
       situations.  For  example, output from multiple nodes may be mixed together. The -B and -C options can be
       used to change this default.

       In-band IPMI Communication will be used when the host "localhost" is specified. This allows the  user  to
       add the localhost into the hostranged output.

GENERAL TROUBLESHOOTING

       Most often, IPMI problems are due to configuration problems.

       IPMI over LAN problems involve a misconfiguration of the remote machine's BMC.  Double check to make sure
       the following are configured properly in the remote machine's BMC: IP address, MAC address, subnet  mask,
       username,  user  enablement,  user  privilege,  password,  LAN  privilege,  LAN  enablement,  and allowed
       authentication type(s). For IPMI 2.0 connections, double check to make sure the cipher suite privilege(s)
       and  K_g  key  are  configured properly. The ipmi-config(8) tool can be used to check and/or change these
       configuration settings.

       Inband IPMI problems are typically caused by improperly configured drivers or non-standard BMCs.

       In addition to the troubleshooting tips below, please see WORKAROUNDS below to  also  if  there  are  any
       vendor specific bugs that have been discovered and worked around.

       Listed below are many of the common issues for error messages.  For additional support, please e-mail the
       <freeipmi-users@gnu.org> mailing list.

       "username invalid" - The username entered (or a NULL username if none was entered) is  not  available  on
       the remote machine. It may also be possible the remote BMC's username configuration is incorrect.

       "password invalid" - The password entered (or a NULL password if none was entered) is not correct. It may
       also be possible the password for the user is not correctly configured on the remote BMC.

       "password verification timeout" - Password verification  has  timed  out.   A  "password  invalid"  error
       (described  above)  or  a generic "session timeout" (described below) occurred.  During this point in the
       protocol it cannot be differentiated which occurred.

       "k_g invalid" - The K_g key entered (or a NULL K_g key if none was entered) is not correct. It  may  also
       be possible the K_g key is not correctly configured on the remote BMC.

       "privilege  level  insufficient"  -  An  IPMI  command  requires  a  higher  user  privilege than the one
       authenticated with. Please try to authenticate with a higher privilege. This may  require  authenticating
       to a different user which has a higher maximum privilege.

       "privilege  level  cannot  be  obtained  for  this  user"  -  The  privilege  level you are attempting to
       authenticate with is higher than the maximum allowed for  this  user.  Please  try  again  with  a  lower
       privilege.  It  may  also  be  possible  the maximum privilege level allowed for a user is not configured
       properly on the remote BMC.

       "authentication type unavailable for attempted privilege level" - The authentication  type  you  wish  to
       authenticate  with  is  not  available  for  this  privilege  level.  Please  try again with an alternate
       authentication type or alternate privilege level. It may also be possible  the  available  authentication
       types you can authenticate with are not correctly configured on the remote BMC.

       "cipher suite id unavailable" - The cipher suite id you wish to authenticate with is not available on the
       remote BMC. Please try again with an alternate cipher suite id. It may also  be  possible  the  available
       cipher suite ids are not correctly configured on the remote BMC.

       "ipmi  2.0  unavailable"  - IPMI 2.0 was not discovered on the remote machine. Please try to use IPMI 1.5
       instead.

       "connection timeout" - Initial IPMI communication failed. A number  of  potential  errors  are  possible,
       including  an  invalid  hostname specified, an IPMI IP address cannot be resolved, IPMI is not enabled on
       the remote server, the network connection is bad, etc. Please verify configuration and connectivity.

       "session timeout" - The IPMI session has timed out. Please reconnect.  If this error  occurs  often,  you
       may wish to increase the retransmission timeout. Some remote BMCs are considerably slower than others.

       "device  not  found"  - The specified device could not be found. Please check configuration or inputs and
       try again.

       "driver timeout" - Communication with the driver or device has timed out. Please try again.

       "message timeout" - Communication with the driver or device has timed out. Please try again.

       "BMC busy" - The BMC is currently busy. It may be processing information or have  too  many  simultaneous
       sessions to manage. Please wait and try again.

       "could  not  find  inband  device"  - An inband device could not be found.  Please check configuration or
       specify specific device or driver on the command line.

       "driver timeout" - The inband driver has timed out communicating to the local BMC or  service  processor.
       The BMC or service processor may be busy or (worst case) possibly non-functioning.

       "internal  IPMI  error" - An IPMI error has occurred that FreeIPMI does not know how to handle. Please e-
       mail <freeipmi-users@gnu.org> to report the issue.

       "sensor config file parse error" - A parse error was found in  the  sensor  interpretation  configuration
       file. Please see freeipmi_interpret_sensor.conf(5).

WORKAROUNDS

       With  so  many  different  vendors implementing their own IPMI solutions, different vendors may implement
       their IPMI protocols incorrectly. The following describes a number of workarounds currently available  to
       handle  discovered  compliance  issues.  When possible, workarounds have been implemented so they will be
       transparent to the user. However, some will require the user to specify a workaround be used via  the  -W
       option.

       The hardware listed below may only indicate the hardware that a problem was discovered on. Newer versions
       of hardware may fix the problems indicated below. Similar machines from vendors may or  may  not  exhibit
       the same problems. Different vendors may license their firmware from the same IPMI firmware developer, so
       it may be worthwhile to try workarounds listed below even if your motherboard is not listed.

       If you believe your  hardware  has  an  additional  compliance  issue  that  needs  a  workaround  to  be
       implemented,    please    contact    the    FreeIPMI    maintainers    on   <freeipmi-users@gnu.org>   or
       <freeipmi-devel@gnu.org>.

       assumeio - This workaround flag will assume inband interfaces communicate with  system  I/O  rather  than
       being memory-mapped. This will work around systems that report invalid base addresses. Those hitting this
       issue may see "device not supported" or "could not find inband device"  errors.   Issue  observed  on  HP
       ProLiant DL145 G1.

       spinpoll  -  This  workaround  flag will inform some inband drivers (most notably the KCS driver) to spin
       while polling rather than putting the process to sleep. This may significantly  improve  the  wall  clock
       running  time  of  tools  because an operating system scheduler's granularity may be much larger than the
       time it takes to perform a single IPMI message transaction. However, by  spinning,  your  system  may  be
       performing less useful work by not contexting out the tool for a more useful task.

       authcap  -  This  workaround  flag  will  skip  early  checks  for  username capabilities, authentication
       capabilities, and K_g support and allow IPMI authentication to succeed. It works around  multiple  issues
       in  which  the remote system does not properly report username capabilities, authentication capabilities,
       or K_g status. Those hitting this issue may see "username invalid", "authentication type unavailable  for
       attempted  privilege  level",  or "k_g invalid" errors.  Issue observed on Asus P5M2/P5MT-R/RS162-E4/RX4,
       Intel SR1520ML/X38ML, and Sun Fire 2200/4150/4450 with ELOM.

       nochecksumcheck - This workaround flag will tell FreeIPMI to not check the checksums returned  from  IPMI
       command  responses.  It  works around systems that return invalid checksums due to implementation errors,
       but the packet is otherwise valid. Users are  cautioned  on  the  use  of  this  option,  as  it  removes
       validation  of  packet  integrity in a number of circumstances. However, it is unlikely to be an issue in
       most situations. Those hitting this issue may see "connection timeout", "session timeout",  or  "password
       verification  timeout"  errors. On IPMI 1.5 connections, the "noauthcodecheck" workaround may also needed
       too. Issue observed on Supermicro X9SCM-iiF, Supermicro X9DRi-F, and Supermicro X9DRFR.

       idzero - This workaround flag will allow empty session IDs to be accepted by the client. It works  around
       IPMI  sessions  that  report  empty  session IDs to the client. Those hitting this issue may see "session
       timeout" errors. Issue observed on Tyan S2882 with M3289 BMC.

       unexpectedauth - This workaround flag will allow unexpected non-null authcodes to be  checked  as  though
       they  were expected. It works around an issue when packets contain non-null authentication data when they
       should be null due to disabled per-message authentication. Those hitting  this  issue  may  see  "session
       timeout" errors. Issue observed on Dell PowerEdge 2850,SC1425. Confirmed fixed on newer firmware.

       forcepermsg  -  This  workaround  flag will force per-message authentication to be used no matter what is
       advertised by the remote system. It works around an issue when per-message authentication  is  advertised
       as  disabled on the remote system, but it is actually required for the protocol. Those hitting this issue
       may see "session timeout" errors.  Issue observed on IBM eServer 325.

       endianseq - This workaround flag will flip the endian of  the  session  sequence  numbers  to  allow  the
       session  to  continue  properly.  It  works  around  IPMI 1.5 session sequence numbers that are the wrong
       endian.  Those hitting this issue may see "session timeout" errors.  Issue  observed  on  some  Sun  ILOM
       1.0/2.0 (depends on service processor endian).

       noauthcodecheck  - This workaround flag will tell FreeIPMI to not check the authentication codes returned
       from IPMI 1.5 command responses. It works around systems that return invalid authentication codes due  to
       hashing  or  implementation  errors.  Users  are  cautioned  on  the use of this option, as it removes an
       authentication check verifying the validity of a packet. However, in most organizations, this is unlikely
       to  be  a  security  issue.  Those hitting this issue may see "connection timeout", "session timeout", or
       "password verification timeout" errors.  Issue observed on Xyratex  FB-H8-SRAY,  Intel  Windmill,  Quanta
       Winterfell, and Wiwynn Windmill.

       intel20  - This workaround flag will work around several Intel IPMI 2.0 authentication issues. The issues
       covered include padding of usernames, and password truncation if the authentication  algorithm  is  HMAC-
       MD5-128.  Those  hitting  this  issue  may  see  "username invalid", "password invalid", or "k_g invalid"
       errors. Issue observed on Intel SE7520AF2 with Intel Server Management Module (Professional Edition).

       supermicro20 - This workaround flag will work around several Supermicro IPMI 2.0 authentication issues on
       motherboards   w/   Peppercon   IPMI  firmware.  The  issues  covered  include  handling  invalid  length
       authentication codes. Those hitting this issue may see "password  invalid"  errors.   Issue  observed  on
       Supermicro H8QME with SIMSO daughter card. Confirmed fixed on newerver firmware.

       sun20 - This workaround flag will work work around several Sun IPMI 2.0 authentication issues. The issues
       covered include invalid lengthed hash keys, improperly hashed keys, and  invalid  cipher  suite  records.
       Those  hitting  this  issue may see "password invalid" or "bmc error" errors.  Issue observed on Sun Fire
       4100/4200/4500 with ILOM.  This workaround automatically includes the "opensesspriv" workaround.

       opensesspriv - This workaround flag will slightly  alter  FreeIPMI's  IPMI  2.0  connection  protocol  to
       workaround  an  invalid  hashing algorithm used by the remote system. The privilege level sent during the
       Open Session stage of an IPMI 2.0 connection is used for hashing keys instead of the privilege level sent
       during the RAKP1 connection stage. Those hitting this issue may see "password invalid", "k_g invalid", or
       "bad rmcpplus status code" errors.  Issue  observed  on  Sun  Fire  4100/4200/4500  with  ILOM,  Inventec
       5441/Dell  Xanadu  II,  Supermicro  X8DTH,  Supermicro  X8DTG,  Intel  S5500WBV/Penguin Relion 700, Intel
       S2600JF/Appro 512X, and Quanta QSSC-S4R/Appro GB812X-CN. This workaround is automatically triggered  with
       the "sun20" workaround.

       integritycheckvalue  -  This  workaround flag will work around an invalid integrity check value during an
       IPMI 2.0 session establishment when using Cipher Suite ID 0.  The  integrity  check  value  should  be  0
       length,  however the remote motherboard responds with a non-empty field. Those hitting this issue may see
       "k_g invalid" errors. Issue observed on Supermicro X8DTG, Supermicro X8DTU,  and  Intel  S5500WBV/Penguin
       Relion 700, and Intel S2600JF/Appro 512X.

       assumemaxsdrrecordcount  -  This workaround will inform SDR reading to stop reading after a known maximum
       numer of SDR records have been read. This will work around systems that have mis-implemented SDR  reading
       functions  that.  Those  hitting  this issue may see "SDR record count invalid" errors. Issue observed on
       unspecified Inspur motherboard.

       discretereading - This workaround option will allow analog sensor readings (i.e. rpm, degrees,  etc.)  to
       be  read  even  if  the  event/reading type code for the sensor is for a discrete sensor (i.e. assert vs.
       deassert). This option works around poorly defined (and arguably illegal) SDR records that expect  analog
       sensor  readings to be read alongside discrete sensors. This option is confirmed to work around issues on
       HP Proliant DL380 G7 and HP ProLiant ML310 G5 motherboards.

       ignorescanningdisabled - This workaround option will allow sensor readings to be read even if the  sensor
       scanning  bit  indicates  a  sensor  is  disabled. This option works around motherboards that incorrectly
       indicate sensors as disabled. This may problem may exist on your motherboard if  sensors  are  listed  as
       "N/A"  even if they should be available. This option is confirmed to work around issues on Dell Poweredge
       2900,  Dell  Poweredge  2950,  Dell  Poweredge  R410,  Dell  Poweredge  R610,  and  HP  Integrity  rx3600
       motherboards.

       assumebmcowner  - This workaround option will allow sensor readings to be read if the sensor owner is the
       BMC, but the reported sensor owner is not the BMC. Typically, sensors owned by  a  non-BMC  sensor  owner
       must  be bridged (e.g. with the --bridge-sensors option), however if the non-BMC sensor owner is invalid,
       bridging fails. This option works around motherboards that incorrectly report an non-BMC sensor owner  by
       always  assuming  the  sensor owner is the BMC. This problem may exist on your motherboard if sensors are
       listed as "N/A" even if they should be available. This option is  confirmed  to  work  around  issues  on
       Fujitsu RX300 and Fujitsu RX300S2 motherboards.

       ignoreauthcode  -  This  workaround option will allow sensor readings to be read if the remote machine is
       invalidly calculating authentication codes (i.e. authentication hashes) when communicating over LAN. This
       problem  may  exist  on  your system if the error "session timeout" errors or there is an appearance of a
       hang.  Users are cautioned on the use of this option, as it removes an authentication check verifying the
       validity  of  a  packet.  However,  in  most  organizations, this is unlikely to be a security issue. The
       ignoring of authentication packets is only limited to the period in which sensor readings are  done,  and
       not  for  any portion of the session authentication or session teardown. This option is confirmed to work
       on Inventec 5441/Dell Xanadu II and Inventec 5442/Dell Xanadu III.  (Note: On  the  above  systems,  this
       issue has only been observed when the --bridge-sensors is used.)

       No  IPMI  1.5  Support - Some motherboards that support IPMI 2.0 have been found to not support IPMI 1.5.
       Those hitting this issue may see "ipmi 2.0 unavailable" or "connection timeout" errors. This issue can be
       worked  around  by using IPMI 2.0 instead of IPMI 1.5 by specifying --driver-type=LAN_2_0. Issue observed
       on HP Proliant DL 145.

OEM INTERPRETATION

       The following motherboards are confirmed to have atleast some support by the --interpret-oem-data option.
       While  highly  probable  the  OEM  data  interpretations would work across other motherboards by the same
       manufacturer,  there  are  no  guarantees.  Some  of  the  motherboards  below  may   be   rebranded   by
       vendors/distributors.

       Dell  Poweredge  R210, Dell Poweredge R610, Dell Poweredge R710, Dell Poweredge R720, Fujitsu iRMC S1 and
       iRMC S2 systems, HP Proliant DL160 G8, Intel S5500WB/Penguin Computing Relion  700,  Intel  S2600JF/Appro
       512X, Intel S5000PAL, Intel Windmill, Quanta Winterfell, Supermicro X7DBR-3, Supermicro X7DB8, Supermicro
       X8DTN, Supermicro X7SBI-LN4, Supermicro X8DTH, Supermicro X8DTG, Supermicro X8DTU, Supermicro X8DT3-LN4F,
       Supermicro  X8DTU-6+,  Supermicro  X8DTL,  Supermicro  X8DTL-3F,  Supermicro  X8SIL-F,  Supermicro X9SCL,
       Supermicro X9SCM, Supermicro  X8DTN+-F,  Supermicro  X8SIE,  Supermicro  X9SCA-F-O,  Supermicro  H8DGU-F,
       Supermicro  X9DRi-F, Supermicro X9DRI-LN4F+, Supermicro X9SPU-F-O, Supermicro X9SCM-iiF, Wiwynn Windmill,
       Wistron/Dell Poweredge C6220.

EXAMPLES

       # ipmi-sensors

       Show all sensors and readings on the local machine.

       # ipmi-sensors --verbose

       Show verbose sensors and readings on the local machine.

       # ipmi-sensors --record-ids="7,11,102"

       Show sensor record ids 7, 11, and 102 on the local machine.

       # ipmi-sensors --sensor-types=fan

       Show all sensors of type fan on the local machine.

       # ipmi-sensors -h ahost -u myusername -p mypassword

       Show all sensors on a remote machine using IPMI over LAN.

       # ipmi-sensors -h mycluster[0-127] -u myusername -p mypassword

       Show all sensors across a cluster using IPMI over LAN.

DIAGNOSTICS

       Upon successful execution, exit status is 0. On error, exit status is 1.

       If multiple hosts are specified for communication, the exit status is  0  if  and  only  if  all  targets
       successfully execute. Otherwise the exit status is 1.

KNOWN ISSUES

       On older operating systems, if you input your username, password, and other potentially security relevant
       information on the command line, this information may be discovered by other users when using tools  like
       the  ps(1)  command  or  looking  in the /proc file system. It is generally more secure to input password
       information with options like the -P or -K options. Configuring  security  relevant  information  in  the
       FreeIPMI configuration file would also be an appropriate way to hide this information.

       In  order  to  prevent brute force attacks, some BMCs will temporarily "lock up" after a number of remote
       authentication errors. You may need to wait awhile in order to this temporary "lock up"  to  pass  before
       you may authenticate again.

       Some sensors may be output as not available (i.e. N/A) because the owner of the sensor is not the BMC. To
       attempt to bridge sensors and access  sensors  not  on  the  BMC,  users  may  wish  to  try  the  -b  or
       --bridge-sensors options.

REPORTING BUGS

       Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

       Copyright © 2003-2014 FreeIPMI Core Team.

       This  program  is  free  software;  you  can  redistribute it and/or modify it under the terms of the GNU
       General Public License as published by the Free Software Foundation; either version 3 of the License,  or
       (at your option) any later version.

SEE ALSO

       freeipmi(7), bmc-device(8), ipmi-config(8), freeipmi_interpret_sensor.conf(5)

       http://www.gnu.org/software/freeipmi/