Provided by: xserver-xorg-input-wacom_0.39.0-0ubuntu1_amd64 bug

NAME

       xsetwacom - commandline utility to query and modify wacom driver settings.

SYNOPSIS

       xsetwacom [options] [command [arguments]]

DESCRIPTION

       This program queries or changes properties on the devices loaded by the wacom driver. The modification of
       properties happens at runtime and is not persistent through X server restarts.

GENERAL OPTIONS

       -d, --display display_name
              Connect to the X server specified in display_name; see X(7).

       -h, --help
              Prints a short help.

       -v, --verbose
              Enable verbose output, useful for debugging.

       -V, --version
              Display version number and exit.

COMMANDS

       Allowed commands are list, get, and set.  The command may  be  specified  with  or  without  one  or  two
       preceding dashes, i.e.  --list is equivalent to -list and list.

   LIST COMMANDS
       list devices
              List known devices. Only input devices managed by the wacom driver are listed.

       list parameters
              List  known parameters. List all parameters suitable for the get or the set command. Note that not
              all parameters are available on all device types.

       list modifiers
              List the aliases for modifiers and other  keys  that  can  be  used  when  setting  button  action
              mappings.

   GET COMMANDS
       get device_name parameter
              Get  the  current settings for the parameter on the given device. Note that not all parameters are
              available on all device types. The special parameter name "all" may be  provided  to  display  all
              current settings on the device.

       By default, options are printed on the commandline in the respective format.
              The output format may be altered with one of the following options:

       -s, --shell
              Display  the  output  in  shell  format, i.e. as shell commands to xsetwacom to reproduce the same
              parameter.

       -x, --xconf
              Display the output in xorg.conf format, i.e. as option lines that may be added to the  InputDevice
              section in the xorg.conf.

   SET COMMANDS
       set device_name parameter [value]
              Set  the  parameter  value on the given device to the value provided. Note that not all parameters
              are writable, some are read-only and result in an error when trying to be modified.

PARAMETERS

       Not all parameters are available on all tools.  Use the get command with the parameter or "all" parameter
       for specific input tool applicable parameters and current settings.

       Area x1 y1 x2 y2
              Set the tablet input area in device coordinates in the form top left x/y and bottom right x/y. Top
              left and bottom right are defined in the device's native orientation,  regardless  of  the  actual
              rotation currently applied. Input outside of these coordinates will be clipped to the edges of the
              area defined.  Default:  0 0 x2 y2; with x2 and y2 tablet specific.

       Button button-number [mapping]
              Set a mapping for the specified button-number. Mappings take the form of either a  single  numeric
              button or an 'action' to be performed. If no mapping is provided, the default mapping is restored.
              If button-number is mapped to 0, the Button event is ignored.

              Numeric button mappings indicate what X11 button number the given button-number should  correspond
              to. For example, a mapping of "3" means a press of the given button-number will produce a press of
              X11 button 3 (i.e. right click).

              Action mappings allow button presses to perform many events. They take the form  of  a  string  of
              keywords and arguments.

              The  "key" keyword is followed by a list of key names. These can optionally be preceded by "+" for
              press and "-" for release. If +/- is not given, press-and-release is assumed, except for  modifier
              keys which are left pressed.  Key names can be X11 KeySyms or some aliases such as 'shift' or 'f1'
              (the full list can be seen with the list modifiers command).

              To assign a key that is not in the modifiers list, use the KeySym in  /usr/include/X11/keysymdef.h
              with  the  XK_  prefix  removed  or  its  actual  value as is. For example, XK_BackSpace should be
              specified as "BackSpace". "0xff80" can also be used to replace "BackSpace" since it's  the  unique
              KeySym value of Backspace key.

              Here  is a combined example: "key +a shift b shift -a 0xff0d" converts the button into a series of
              keystrokes. In this example, "press a, press shift, press and release b, release shift, release a,
              then press and release enter".  "key +a +shift b -shift -a 0xff0d" does the same thing.

              The "button" keyword is similar except that its arguments are X11 button numbers.

              The  "modetoggle"  keyword  is also recognized; it takes no arguments, and toggles the device mode
              between relative and absolute pointer tracking.

              The "pan" keyword causes the driver to send scroll events while the pen is dragged. This makes  it
              easy  to  scroll through lists and documents, pan around 2D canvases, and zoom in/out of 3D scenes
              (exact behavior depends on application interpretation of scrollwheel  events).  Dragging  the  pen
              up/down  will  send  scrollwheel  down/up  events;  dragging  it  left/right will send scrollwheel
              right/left events.

              The events in the action mapping are sent when the physical button  is  pressed.   If  the  action
              mapping  leaves  any  buttons or keys pressed (such as a modifier key), they will be released when
              the physical button is released.

              Multiple keywords may be present in one action if desired: for example "key  +ctrl  button  5  key
              -ctrl". Each keyword takes all arguments until the next keyword.

              A maximum of 256 presses and/or releases can be specified in an action mapping.

              The  driver  can  only  simulate  physical key events but not keysyms and xsetwacom translates the
              mapping sequence into such events. Thus, symbols on the same physical key will generate  the  same
              event.  For  example,  '1'  and  '!'  are  on the same key on a US keyboard and thus have the same
              keycode).  For access to keys on a higher shift level, the sequence should be entered as it  would
              be  typed  on  a  physical keyboard. For example, a exclamation mark is entered by the sequence of
              "key +shift 1 -shift".

       BindToSerial [serial|0]
              Bind the device to the tool with the specified serial number. Once bound, the device  will  ignore
              events  from  other tools. A serial of 0 means the device is unbound and will react to any tool of
              the matching type.  Default: 0

       MapToOutput [output]
              Map the tablet's input area to a given output (e.g. "VGA1"). Output names may either be  the  name
              of  a  head  available  through  the  XRandR  extension,  or  an  X11  geometry string of the form
              WIDTHxHEIGHT+X+Y. To switch to the next available output, the "next" keyword  is  also  supported.
              This  will  cycle  between  the  individual  monitors connected to the system, and then the entire
              desktop. The mapping may be reset to  the  entire  desktop  at  any  time  with  the  output  name
              "desktop".  Users  of  the  NVIDIA binary driver should use the output names "HEAD-0" and "HEAD-1"
              until the driver supports XRandR 1.2 or later.

              The output mapping configuration is a onetime setting and does not track output  reconfigurations;
              the  command  needs  to be re-run whenever the output configuration changes. When used with tablet
              rotation, the tablet must be rotated before it is mapped to the  new  screen.  This  parameter  is
              write-only and cannot be queried.

       Mode Absolute|Relative
              Set the device mode as either Relative or Absolute. Relative means pointer tracking for the device
              will function like a mouse, whereas Absolute means the pointer corresponds to the device's  actual
              position  on  the tablet or tablet PC screen.  Default:  Absolute for stylus, eraser and tablet PC
              touch; Relative for cursor and tablet touch.

       PressureCurve x1 y1 x2 y2
              A Bezier curve of third order, composed of two anchor  points  (0,0  and  100,100)  and  two  user
              modifiable  control  points  that  define  the  curve's  shape.   Raise the curve (x1<y1 x2<y2) to
              "soften" the feel and lower the curve (x1>y1 x2>y2) for a "firmer" feel.   Sigmoid  shaped  curves
              are  permitted (x1>y1 x2<y2 or x1<y1 x2>y2).  Default:  0 0 100 100, a linear curve; range of 0 to
              100 for all four values.

       RawSample level
              Set the sample window size (a sliding average sampling window) for incoming input  tool  raw  data
              points.  Default:  4, range of 1 to 20.

       Rotate none|half|cw|ccw
              Set the tablet to the given rotation:
                none: the tablet is not rotated and uses its natural rotation
                half: the tablet is rotated by 180 degrees (upside-down)
                cw: the tablet is rotated 90 degrees clockwise
                ccw: the tablet is rotated 90 degrees counter-clockwise

              Rotation is a tablet-wide option: rotation of one tool affects all other tools associated with the
              same tablet. When the  tablet  is  physically  rotated,  rotate  any  tool  to  the  corresponding
              orientation.  Default:  none

       Suppress level
              Set  the  delta (difference) cutoff level for further processing of incoming input tool coordinate
              values.  For example a X or Y coordinate event will be sent only if the change between the current
              X  or  Y  coordinate and the previous one is greater than the Suppress value.  The same applies to
              pressure level (Z coordinate) and Tilt rotation values.  With a current absolute wheel  (AbsWheel)
              or  Tilt  value  the  delta between it and the previous value must be equal to or greater than the
              Suppress value in order to be sent on.  Suppress is a tablet wide parameter.   A  specified  delta
              level  for  one input tool is applied to all input tool coordinates.  To disable suppression use a
              level of 0.  Default:  2, range of 0 to 100.

       TabletDebugLevel level
              Set the debug level for this tablet to the given level. This only  affects  code  paths  that  are
              shared  between  several tools on the same physical tablet. A higher level means more fine-grained
              debug messages, a level of 0 turns debugging off for this tool. Requires the driver  to  be  built
              with debugging enabled. See also ToolDebugLevel.  Default:  0, range of 0 to 12.

       TabletPCButton on|off
              If  on,  the  stylus must be in contact with the screen for a stylus side button to work.  If off,
              stylus buttons will work once the stylus is in proximity of the tablet (regardless of  whether  it
              is touching the screen).  Default:  on for Tablet PCs; off for all other models.

       ToolSerialPrevious
              Get  the  serial number of the tool that was last in proximity last. This serial number is updated
              whenever the tool goes out of proximity. If the current tool went  out  of  proximity  once,  this
              serial number is the one of the current tool. This is a read-only parameter.

       Touch on|off
              If  on,  touch  events  are  reported to userland, i.e., system cursor moves when user touches the
              tablet. If off, touch events are ignored. Default: on for devices that support touch; off for  all
              other models.

       HWTouchSwitchState on|off
              If  on,  it  means  touch switch is turned off. That is, touch events are reported to userland. If
              off, touch switch is turned on, i.e., touch events are ignored.  This is  a  read-only  parameter.
              Initial touch switch state is retrieved from the kernel when X driver starts.

       CursorProximity distance
              Set  the  distance  at  which  a  relative tool is treated as being out of proximity.  Beyond this
              distance the cursor will stop responding to tool motion. The default value for pucks is 10 (Intuos
              Pro) or 42 (Intuos/Bamboo). The default value for pens is 30.

       Threshold level
              Set  the  minimum  pressure  necessary  to  generate a Button event for the stylus tip, eraser, or
              touch.  The pressure levels of all tablets are normalized  to  2048  levels  irregardless  of  the
              actual  hardware  supported levels.  This parameter is independent of the PressureCurve parameter.
              Default:  27, range of 0 to 2047.

       ToolDebugLevel level
              Set the debug level for this tool to the given level.  This  only  affects  code  paths  that  are
              specific  to  a  given  tool.  A higher level means more fine-grained debug messages, a level of 0
              turns debugging off for this tool. Requires the driver to be built  with  debugging  enabled.  See
              also TabletDebugLevel.  Default:  0, range of 0 to 12.

       PressureRecalibration on|off
              If the initial pressure of a device is != 0 the driver recalibrates the pressure range. This is to
              account for worn out devices.  The downside is that when the user hits the tablet  very  hard  the
              initial  pressure reading may be unequal to zero even for a perfectly good pen. If the consecutive
              pressure readings are not higher than the initial pressure by a threshold no button event will  be
              generated.  This option allows to disable the recalibration.  Default:  on

       PanScrollThreshold distance
              This specifies the distance the pen must move (in tablet units) before a scroll event is generated
              when using the "pan" action. Smaller values will require less  distance  and  be  more  sensitive.
              Larger  values  will require more distance and be less sensitive.  Default: 1300 or 2600 depending
              on tablet resolution (corresponds to 13 mm of distance).

WAYLAND SUPPORT

       This tool provides access to the device properties implemented in the  xf86-input-wacom  X  server  input
       module. It does not work under a Wayland compositor as the input module is not active.

       See https://github.com/linuxwacom/xf86-input-wacom/wiki/Wayland for details.

AUTHORS

       Peter Hutterer <peter.hutterer@redhat.com>

SEE ALSO

       Xorg(1), wacom(4), xorg.conf(5), X(7)

       More information is available at https://github.com/linuxwacom/xf86-input-wacom