Provided by: libsane-common_1.0.29-0ubuntu5.2_all bug

NAME

       sane-sharp - SANE backend for SHARP scanners

DESCRIPTION

       The  sane-sharp library implements a SANE (Scanner Access Now Easy) backend that provides access to Sharp
       SCSI scanners.  This backend should be considered beta-quality software!  In  the  current  state  it  is
       known  to work with JX-610 and JX-250 scanners. It is prepared for usage with the JX-330 series scanners,
       but we are not able to test it with these devices.

       For other Sharp scanners, it may or may not work.

       At present, the following scanners are known to work with this backend.

              Vendor  Product id:
              -----   -----------
              Sharp   JX-610
              Sharp   JX-250
              Sharp   JX-320
              Sharp   JX-330
              Sharp   JX-350

       The following scanners are detected by the backend, but not tested:

              Vendor  Product id:
              -----   -----------
              Sharp   JX-325

DEVICE NAMES

       This backend expects device names of the form:

              special

       Where special is either the path-name for the special device that corresponds  to  a  SCSI  scanner.  The
       special  device  name  must  be a generic SCSI device or a symlink to such a device.  Under Linux, such a
       device name could be /dev/sga or /dev/sge, for example.  See sane-scsi(5) for details.

SCAN OPTIONS

       Scan Mode (parameter --mode for scanimage). Possible settings:
              Lineart (1 bit black & white scans),
              Gray (8 bit gray scale scans),
              Lineart Color (bi-level color scans),
              Color (8 bit RGB scans).
       The default value is Color.

       Halftone Pattern (parameter --halftone-pattern for scanimage).  Available  only  for  the  JX-330  series
       scanners.  Possible settings:
              none
              Dither Bayer
              Dither Spiral
              Dither Dispersed
              Error Diffusion
       The default value is none.

       Paper  Source (parameter --source for scanimage). This option is only available, if an automatic document
       feeder or a transparency adapter is installed. Possible settings:
              Flatbed
              Automatic Document Feeder
              Transparency Adapter
       If an ADF or a transparency adapter is installed, using it is the default selection.

       Custom Gamma (parameter --custom-gamma for scanimage). This option determines  whether  a  builtin  or  a
       custom gamma-table is used. Possible settings:
              yes enables custom gamma tables
              no enables a built gamma table

       Gamma  (parameter  --Gamma  for  scanimage). This option is only available, if Custom Gamma is set to no.
       Possible values:
              1.0
              2.2
       The default value is 2.2. (The JX-250 and JX-350 have no built in gamma correction; for these scanner,  a
       gamma table is downloaded to the scanner by the backend.)

       Gamma Table (parameter --gamma-table for scanimage). Allowed values: 0..255; 256 numbers must be defined.
       The default values are 0, 1, 2, .. 255 (i.e., gamma == 1). This table is only used for gray scale scans.

       Red  Gamma Table (parameter --red-gamma-table for scanimage). Allowed values: 0..255; 256 numbers must be
       defined.  The default values are 0, 1, 2, .. 255 (i.e., gamma == 1).

       Green Gamma Table (parameter --green-gamma-table for scanimage). Allowed values: 0..255; 256 numbers must
       be defined.  The default values are 0, 1, 2, .. 255 (i.e., gamma == 1).

       Blue Gamma Table (parameter --blue-gamma-table for scanimage). Allowed values: 0..255; 256  numbers  must
       be defined.  The default values are 0, 1, 2, .. 255 (i.e., gamma == 1).

       Resolution  in  pixel  per  inch  (parameter  --resolution  for scanimage). Selects the resolution of the
       scanned image. Allowed values:
              30..600 (JX-330, JX-350 and JX-610) resp.  30..400 (JX-250)
       The default value is 150.

       Scan Window

       The possible settings depend on the scanner model and, for the JX-250 and the JX-350, also on  the  usage
       of  the  automatic  document feeder resp. the transparency adapter. Please refer to the values allowed by
       xscanimage, or xsane. With scanimage, enter one of the following commands:

              scanimage -d sharp --source "Automatic Document Feeder" --help

              scanimage -d sharp --source Flatbed --help

              scanimage -d sharp --source "Transparency Adapter" --help

       in order to see the allowed parameter values for the scan window.

       The scan window parameters are:

              Top-left x position of scan area (parameter -l for scanimage);
              Top-left y position of scan area (parameter -t for scanimage);
              bottom right x position of scan area (parameter -x for scanimage);
              bottom right y position of scan area (parameter -y for scanimage);

       Edge emphasis (parameter --Edge emphasis for scanimage). This option is not available for the JX-250  and
       the JX-350.  Possible settings:
              None
              Middle
              Strong
              Blur
       The default value is None.

       Threshold (parameter --threshold for scanimage). Sets the threshold for black and white pixels in lineart
       mode. Possible values:
              1..255
       The default value is 128.  This option is only available in scan mode lineart.

       Threshold  Red  (parameter  --threshold-red for scanimage). Sets the threshold for the red component of a
       pixel in in lineart color scan mode. Possible values:
              1..255
       The default value is 128.  This option is only available in scan mode color lineart.

       Threshold Green (parameter --threshold-green for scanimage). Sets the threshold for the  green  component
       of a pixel in in lineart color scan mode. Possible values:
              1..255
       The default value is 128.  This option is only available in scan mode color lineart.

       Threshold Blue (parameter --threshold-blue for scanimage). Sets the threshold for the blue component of a
       pixel in in lineart color scan mode. Possible values:
              1..255
       The default value is 128.  This option is only available in scan mode color lineart.

       Light Color (parameter --LightColor for scanimage). Sets the color of the light source. Possible values:
              white
              red
              green
              blue
       The default value is white.  This option is only available in scan modes lineart color and color.

ADF USAGE

       If a paper jam occurred, the maintenance cover must be opened and closed, even if the jammed paper can be
       removed without opening the maintenance cover. Otherwise, the error condition cannot be cleared.

CONFIGURATION

       The  contents  of  the  sharp.conf  file  is  a list of options and device names that correspond to Sharp
       scanners. Empty lines and lines beginning with a hash mark (#) are ignored. See sane-scsi(5) for  details
       about device names.

       Lines  setting  an  option start with the key word option, followed by the option's name and the option's
       value. At present, three options are defined: buffers, buffersize, and readqueue.

       Options defined at the start of sharp.conf apply to all devices; options  defined  after  a  device  name
       apply to this device.

       The  options buffers and readqueue are only significant if the backend has been compiled so that for each
       scan a second process is forked (switch USE_FORK in sharp.c ). This process reads the scan data from  the
       scanner  and writes this data into a block of shared memory.  The parent process reads the data from this
       memory block and delivers it to the frontend. The options control the  size  and  usage  of  this  shared
       memory block.

       option buffers defines the number of buffers used. The smallest number allowed is 2.

       option  buffersize defines the size of one buffer. Since each buffer is filled with a single read command
       sent to the scanner, its size is limited automatically to the size allowed by the operating system or  by
       the  Sane  SCSI library for SCSI read commands. A buffer size of 128 kB or 256 kB is recommended for scan
       resolutions of 300 dpi and above.

       option readqueue defines how many read commands to be sent to the scanner are  queued.  At  present,  the
       Sane  SCSI  library supports queued read commands only for for Linux. For other operating systems, option
       readqueue should be set to 0. For Linux, option readqueue should be set to 2. Larger values  than  2  for
       option  readqueue  are  not  reasonable  in  most  cases.   option  buffers should be greater than option
       readqueue.

Performance Considerations

       This section focuses on the problem of stops of the scanner's carriage  during  a  scan.  Carriage  stops
       happen  mainly  with  the JX-250. This scanner has obviously only a small internal buffer compared to its
       speed. That means that the backend must read the data as fast as possible from the scanner  in  order  to
       avoid carriage stops.

       Even the JX-250 needs only less than 10 seconds for a 400 dpi A4 gray scale scan, which results in a data
       transfer  rate  of  more than 1.6 MB per second. This means that the data produced by the scanner must be
       processed fairly fast. Due to the small internal buffer of the JX-250, the  backend  must  issue  a  read
       request  for  the  next  data  block  as soon as possible after reading a block of data in order to avoid
       carriage stops.

       Stops of the carriage can be caused by the following reasons:

              - too much "traffic" on the SCSI bus
              - slow responses by the backend to the scanner,
              - a program which processes the data acquired by the backend too slow.

       Too much "traffic" on the SCSI bus: This happens for example, if hard disks are  connected  to  the  same
       SCSI  bus as the scanner, and when data transfer from/to these hard disks requires a considerable part of
       the SCSI bandwidth during a scan. If this is the case, you should consider to connect the  scanner  to  a
       separate SCSI adapter.

       Slow  responses  by the backend to the scanner: Unfortunately, Unix-like operating systems generally have
       no real time capabilities.  Thus there is no guarantee that the backend is under any  circumstances  able
       to  communicate  with  the  scanner  as fast as required. To minimize this problem, the backend should be
       compiled so that a separate reader process is forked: Make sure that USE_FORK is defined when you compile
       sharp.c.  If slow responses of the backend remain to be problem, you could try to reduce the load of  the
       system.  Even  while the backend and the reader process need only a minor amount of processor time, other
       running processes can cause an increase in the time delay between two time slices  given  to  the  reader
       process.  On  slower  systems,  such  an  increased delay can be enough to cause a carriage stop with the
       JX-250.  For Linux, the usage of the SG driver  version  2.1.36  or  above  is  recommended,  because  it
       supports, in combination with the SCSI library of Sane version 1.0.2, command queueing within the kernel.
       This  queueing implementation, combined with a buffer size of at least 128 kB, should avoid most carriage
       stops.

       Slow processing of the scan data: An example for this situation is the access to the  scanner  via  a  10
       MBit Ethernet, which is definitely too slow to transfer the scan data as fast as they are produced by the
       scanner.  If  you  have enough memory available, you can increase option buffers, so that an entire image
       can be stored in these buffers.

       In order to see, if the backend is too slow or if the further processing of the data is too slow, set the
       environment variable SANE_DEBUG_SHARP to 1. When a scan is finished, the backend writes the line  "buffer
       full  conditions:  nn"  to  stderr. If nn is zero, carriage stops are caused by too slow responses of the
       backend or too much "traffic" on the SCSI bus. If nn is greater than zero, the backend  had  to  wait  nn
       times until a buffer has been processed by the frontend. (Please note that option buffers must be greater
       than option readqueue in order to get useful output for "buffer full conditions".)

FILES

       @CONFIGDIR@/sharp.conf
              The backend configuration file.

       @LIBDIR@/libsane-sharp.a
              The static library implementing this backend.

       @LIBDIR@/libsane-sharp.so
              The shared library implementing this backend (present on systems that support dynamic loading).

ENVIRONMENT

       SANE_DEBUG_SHARP
              If  the  library  was  compiled with debug support enabled, this environment variable controls the
              debug level for this backend.  E.g., a value of 128 requests  all  debug  output  to  be  printed.
              Smaller levels reduce verbosity.

KNOWN PROBLEMS

       1. ADF Mode
              After  several ADF scans, the scanner moves the carriage back to the idle position and back to ADF
              scan position, before a scan starts. We do not know, if this is a problem of the  scanner,  or  if
              this  is a bug of the backend. At present, the scanner must power off and on to stop this annoying
              behaviour.

       2. Threshold level does not work (only JX-610)

       3. The maximum resolution is limited to 600 dpi(JX-610 supported to 1200 dpi) resp. 400 dpi (JX-250)

       4. If the JX250 is used with an ADF, the following situation can occur: After several scans, the  scanner
       moves,  after  loading  a  new  sheet  of  paper, the carriage to the idle position, and then back to the
       position used for ADF scans. This happens for every scan, in contrast to the calibration, which  is  done
       after  10  scans. (For the calibration, the carriage is also moved to the idle position.) We do not know,
       if this behavior is caused by the backend, or if it is a bug in the firmware of the scanner.

       5. Usage of a transparency adapter (film scan unit) is supported, but not tested.

SEE ALSO

       sane(7), sane-scsi(5)

AUTHORS

       Kazuya Fukuda, Abel Deuring

CREDITS

       The Sharp backend is based on the Canon backend written by Helmut Koeberle

       Parts of this man page are a plain copy of sane-mustek(5) by David Mosberger-Tang,  Andreas  Czechanowski
       and Andreas Bolsch

@PACKAGEVERSION@                                   11 Jul 2008                                     sane-sharp(5)