Provided by: waybar_0.9.9-1_amd64
NAME
waybar - temperature module
DESCRIPTION
The temperature module displays the current temperature from a thermal zone.
CONFIGURATION
Addressed by temperature thermal-zone: typeof: integer The thermal zone, as in /sys/class/thermal/. hwmon-path: typeof: string The temperature path to use, e.g. /sys/class/hwmon/hwmon2/temp1_input instead of one in /sys/class/thermal/. hwmon-path-abs: typeof: string The path of the hwmon-directory of the device, e.g. /sys/devices/pci0000:00/0000:00:18.3/hwmon. (Note that the subdirectory hwmon/hwmon#, where # is a number is not part of the path!) Has to be used together with input-filename. input-filename: typeof: string The temperature filename of your hwmon-path-abs, e.g. temp1_input critical-threshold: typeof: integer The threshold before it is considered critical (Celsius). interval: typeof: integer default: 10 The interval in which the information gets polled. format-critical: typeof: string The format to use when temperature is considered critical format: typeof: string default: {temperatureC}°C The format (Celsius/Fahrenheit/Kelvin) in which the temperature should be displayed. format-icons: typeof: array Based on the current temperature (Celsius) and critical-threshold if available, the corresponding icon gets selected. The order is low to high. tooltip-format: typeof: string default: {temperatureC}°C The format for the tooltip rotate: typeof: integer Positive value to rotate the text label. max-length: typeof: integer The maximum length in characters the module should display. min-length: typeof: integer The minimum length in characters the module should take up. align: typeof: float The alignment of the text, where 0 is left-aligned and 1 is right-aligned. If the module is rotated, it will follow the flow of the text. on-click: typeof: string Command to execute when you clicked on the module. on-click-middle: typeof: string Command to execute when middle-clicked on the module using mousewheel. on-click-right: typeof: string Command to execute when you right clicked on the module. on-update: typeof: string Command to execute when the module is updated. on-scroll-up: typeof: string Command to execute when scrolling up on the module. on-scroll-down: typeof: string Command to execute when scrolling down on the module. smooth-scrolling-threshold: typeof: double Threshold to be used when scrolling. tooltip: typeof: bool default: true Option to disable tooltip on hover.
FORMAT REPLACEMENTS
{temperatureC}: Temperature in Celsius. {temperatureF}: Temperature in Fahrenheit. {temperatureK}: Temperature in Kelvin.
EXAMPLES
"temperature": { // "thermal-zone": 2, // "hwmon-path": "/sys/class/hwmon/hwmon2/temp1_input", // "critical-threshold": 80, // "format-critical": "{temperatureC}°C ", "format": "{temperatureC}°C " }
STYLE
• #temperature • #temperature.critical 2022-01-10 waybar-temperature(5)