Provided by: yambar_1.8.0-2_amd64 bug

NAME

       battery - This module reads battery status

DESCRIPTION

       This module reads battery status from /sys/class/power_supply and uses udev to monitor for
       changes.

       Note that it is common (and "normal") for batteries to be in the state unknown under
       certain conditions.

       For example, some have been seen to enter the unknown state when charging and the capacity
       reaches ~90%. The battery then stays in unknown, rather than charging, until it has been
       fully charged and enters the state full.

       This does not happen with all batteries, and other batteries may enter the state unknown
       under other conditions.

TAGS

       ┌─────────────┬────────┬──────────────────────────┐
       │NameTypeDescription              │
       ├─────────────┼────────┼──────────────────────────┤
       │name         │ string │ Battery device name      │
       ├─────────────┼────────┼──────────────────────────┤
       │manufacturer │ string │ Name of the battery      │
       │             │        │ manufacturer             │
       ├─────────────┼────────┼──────────────────────────┤
       │model        │ string │ Battery model name       │
       ├─────────────┼────────┼──────────────────────────┤
       │state        │ string │ One of full, not         │
       │             │        │ charging, charging,      │
       │             │        │ discharging or unknown   │
       ├─────────────┼────────┼──────────────────────────┤
       │capacity     │ range  │ capacity left, in        │
       │             │        │ percent                  │
       ├─────────────┼────────┼──────────────────────────┤
       │estimate     │ string │ Estimated time left (to  │
       │             │        │ empty while discharging, │
       │             │        │ or to full while         │
       │             │        │ charging), formatted as  │
       │             │        │ HH:MM.                   │
       └─────────────┴────────┴──────────────────────────┘

CONFIGURATION

       ┌──────────────┬────────┬─────┬──────────────────────────┐
       │NameTypeReqDescription              │
       ├──────────────┼────────┼─────┼──────────────────────────┤
       │name          │ string │ yes │ Battery device name      │
       │              │        │     │ (one of the names        │
       │              │        │     │ in                       │
       │              │        │     │ /sys/class/power_supply) │
       ├──────────────┼────────┼─────┼──────────────────────────┤
       │poll-interval │ int    │ no  │ How often, in seconds,   │
       │              │        │     │ to poll for capacity     │
       │              │        │     │ changes (default=60).    │
       │              │        │     │ Set to `0` to disable    │
       │              │        │     │ polling (warning: many   │
       │              │        │     │ batteries do not support │
       │              │        │     │ asynchronous reporting). │
       └──────────────┴────────┴─────┴──────────────────────────┘

EXAMPLES

           bar:
             left:
               - battery:
                   name: BAT0
                   poll-interval: 30
                   content:
                     string: {text: "BAT: {capacity}% {estimate}"}

SEE ALSO

       yambar-modules(5), yambar-particles(5), yambar-tags(5), yambar-decorations(5)