NAME

       sane-fujitsu - SANE backend for Fujitsu flatbed and ADF scanners

DESCRIPTION

       The  sane-fujitsu  library  implements  a  SANE  (Scanner  Access  Now Easy) backend which
       provides access to most Fujitsu flatbed and ADF scanners.

       This document describes backend version 139, which initially shipped with SANE 1.1.2.

SUPPORTED HARDWARE

       This version supports every known model which speaks the Fujitsu  SCSI  and  SCSI-over-USB
       protocols.  Specifically, the SCSI M309x and M409x series, the SCSI fi-series, and most of
       the USB fi-, ScanSnap, & iX series  scanners  are  supported.   Please  see  the  list  at
       http://www.sane-project.org/sane-supported-devices.html for details.

       This  backend  may  support  other  Fujitsu  scanners.  The best way to determine level of
       support is to test the scanner directly, or to collect a trace of the  windows  driver  in
       action.  Please contact the author for help or with test results.

UNSUPPORTED HARDWARE

       The following scanners are known NOT to work with this backend, either because they have a
       non-Fujitsu chipset, or an unsupported interface type.  Some  of  these  scanners  may  be
       supported by another backend.

              --------------------------------------
              SCSI:        SERIAL:      USB:
              ------------ ------------ ------------
              ScanStation  M3093E/DE/EX fi-4110EOX/2
              ScanPartner  M3096EX      fi-4010CU
              SP-Jr        M3097E+/DE   S300/S300M
              SP-10/10C    M3099A/EH/EX S1300/S1100
              SP-15C/300C               fi-60F/65F
              SP-600C/620C              fi-5015C
                                        SP-2x/3x

OPTIONS

       Effort has been made to expose all hardware options, including:

       source s
              Selects  the  source for the scan. Options may include "Flatbed", "ADF Front", "ADF
              Back", "ADF Duplex", "Card Front", "Card Back", "Card Duplex".

       mode m
              Selects the mode for the scan. Options may include "Lineart",  "Halftone",  "Gray",
              and "Color".

       resolution, y-resolution
              Controls  scan  resolution.  Setting  --resolution also sets --y-resolution, though
              this behavior is overridden by some frontends.

       tl-x, tl-y, br-x, br-y
              Sets scan area upper left and lower right coordinates. These are renamed t, l, x, y
              by some frontends.

       page-width, page-height
              Sets  paper  size.  Used by scanner to determine centering of scan coordinates when
              using the ADF (Automatic Document Feeder) and to detect double feed errors.

       Other options will be available based on the capabilities of the  scanner:  machines  with
       IPC  or DTC will have additional enhancement options, those with CMP will have compression
       options, those with a printer will have a group of endorser options.

       Additionally,  several  'software'  options  are  exposed  by  the  backend.   These   are
       reimplementations  of  features  provided  natively by larger scanners, but running on the
       host computer. This enables smaller machines to have  similar  capabilities.  Please  note
       that  these  features  are  somewhat simplistic, and may not perform as well as the native
       implementations. Note also that these features all  require  that  the  driver  cache  the
       entire  image  in  memory.  This  will  almost certainly result in a reduction of scanning
       speed.

       swcrop
              Requests the driver to detect the extremities of the paper within the larger image,
              and crop the empty edges.

       swdeskew
              Requests  the  driver  to detect the rotation of the paper within the larger image,
              and counter the rotation.

       swdespeck X
              Requests the driver to find and remove dots of  X  diameter  or  smaller  from  the
              image, and fill the space with the average surrounding color.

       Use  'scanimage --help' to get a list, but be aware that some options may be settable only
       when another option has been set, and that advanced options may be hidden by some frontend
       programs.

CONFIGURATION FILE

       The  configuration file fujitsu.conf is used to tell the backend how to look for scanners,
       and provide options controlling the operation of the backend.  This file is read each time
       the  frontend  asks  the  backend for a list of scanners, generally only when the frontend
       starts. If the configuration file is missing, the backend will be  unable  to  locate  any
       scanners.

       Scanners can be specified in the configuration file in 4 ways:

       "scsi FUJITSU"
              Requests  backend to search all scsi buses in the system for a device which reports
              itself to be a scanner made by 'FUJITSU'.

       "scsi /dev/sg0" (or other scsi device file)
              Requests backend to open the named scsi device. Only useful if  you  have  multiple
              compatible  scanners  connected  to  your system, and need to specify one. Probably
              should not be used with the other "scsi" line above.

       "usb 0x04c5 0x1042" (or other vendor/product ids)
              Requests backend to search all usb buses in the system for a device which uses that
              vendor  and  product  id.  The  device will then be queried to determine if it is a
              Fujitsu scanner.

       "usb /dev/usb/scanner0" (or other device file)
              Some systems use a kernel driver to access usb scanners. This method is untested.

       The only configuration option supported is "buffer-size=xxx",  allowing  you  to  set  the
       number  of bytes in the data buffer to something other than the compiled-in default, 65536
       (64K). Some users report that their scanner will "hang" mid-page, or fail to transmit  the
       image if the buffer is not large enough.

       Note:  This option may appear multiple times in the configuration file. It only applies to
       scanners discovered by 'scsi/usb' lines that follow this option.

       Note: The backend does not place an upper bound on this value, as some users  required  it
       to  be quite large. Values above the default are not recommended, and may crash your OS or
       lockup your scsi card driver. You have been warned.

ENVIRONMENT

       The  backend  uses  a  single  environment  variable,  SANE_DEBUG_FUJITSU,  which  enables
       debugging output to stderr. Valid values are:

              5  Errors
              10 Function trace
              15 Function detail
              20 Option commands
              25 SCSI/USB trace
              30 SCSI/USB writes
              31 SCSI/USB reads
              35 Useless noise

KNOWN ISSUES

       Flatbed units may fail to scan at maximum area, particularly at high resolution.

       Any  model that does not support VPD during inquiry will not function until an override is
       added to the backend.

       CCITT Fax compression used by older scanners is not supported.

       JPEG output is supported by the backend, but not by the SANE protocol, so is  disabled  in
       this release. It can be enabled if you rebuild from source.

       Network interfaces are not supported on any scanner model.

CREDITS

       m3091 backend: Frederik Ramm <frederik a t remote d o t org>
       m3096g backend: Randolph Bentson <bentson a t holmsjoen d o t com>
         (with credit to the unnamed author of the coolscan driver)
       fujitsu backend, m3093, fi-4340C, ipc, cmp, long-time maintainer:
         Oliver Schirrmeister <oschirr a t abm d o t de>
       m3092: Mario Goppold <mgoppold a t tbzpariv d o t tcc-chemnitz dot de>
       fi-4220C and basic USB support: Ron Cemer <ron a t roncemer d o t com>
       fi-4120, fi-series color, backend re-write, jpeg, current maintainer:
         m. allan noah: <kitno455 a t gmail d o t com>

       JPEG output and low memory usage support funded by:
         Archivista GmbH www.archivista.ch

       Endorser support funded by:
         O A S Oilfield Accounting Service Ltd
         1500, 840 - 7th Avenue S.W.
         Calgary, Alberta
         T2P 3G2 Canada
         1-403-263-2600 www.oas.ca

       Automatic length detection support funded by:
         Martin G. Miller mgmiller at optonline.net

       Hardware donated, software image enhancement and fi-6/7xxx support funded by:
         PFU America, Inc.  fujitsuscanners.com

       iX500 support funded by:
         Prefix Computer Services www.prefixservice.com

SEE ALSO

       sane(7), sane-scsi(5), sane-usb(5), sane-sp15c(5), sane-avision(5), sane-epjitsu(5)