Provided by: owfs-doc_3.2p4+dfsg1-4.3build2_all 

NAME
IBLSS - iButtonLink SmartSlave
SYNOPSIS
Wall-TH Humidity and Temperature Sensor.
FE [.]XXXXXXXX2X00[XX][/[ TH/humidity | TH/latesthumidity | TH/temperature | TH/latesttemp | TH/led |
firmware | subtype | address | crc8 | id | locator | r_address | r_id | r_locator | type ]]
FAMILY CODE
FE
SPECIAL PROPERTIES
TH/humidity
read-only, floating point
Humidity read by the chip at high resolution (~13 bits). Unit is % relative humidity. Negative values
indicate a condensing condition. Conversion takes about one second.
TH/latesthumidity
read-only, floating point
Latest measured humidity. Reading this node will never trigger a combined humidity/temperature
conversion. Intended for use after a previous read of the TH/temperature node or in conjunction with
/simultaneous/iblss.
TH/temperature
read-only, floating point
Temperature read by the chip at high resolution (~13 bits). Units are selected from the invoking command
line. See owfs(1) or owhttpd(1) for choices. Default is Celsius. Conversion takes about one second.
TH/latesttemp
read-only, floating point
Latest measured temperature. Reading this node will never trigger a combined humidity/temperature
conversion. Intended for use after a previous read of the TH/humidity node or in conjunction with
/simultaneous/iblss.
TH/led
write-only, yes-no
Switches the indicator LED on/off.
firmware
read-only, ascii
Firmware version of the Smart Slave displayed as major.major number. Firmware versions of the SS-WALL-TH
before 1.4 had known issues with humidity reporting.
subtype
read-only, ascii
Subtype of the Smart Slave. Currently only possible value is "TH" signifying an SS-WALL-TH drywall
temperature/humidity sensor.
STANDARD PROPERTIES
address
r_address
read-only, ascii
The entire 64-bit unique ID. Given as upper case hexadecimal digits (0-9A-F).
address starts with the family code
r address is the address in reverse order, which is often used in other applications and labeling.
crc8
read-only, ascii
The 8-bit error correction portion. Uses cyclic redundancy check. Computed from the preceding 56 bits of
the unique ID number. Given as upper case hexadecimal digits (0-9A-F).
family
read-only, ascii
The 8-bit family code. Unique to each type of device. Given as upper case hexadecimal digits (0-9A-F).
id
r_id
read-only, ascii
The 48-bit middle portion of the unique ID number. Does not include the family code or CRC. Given as
upper case hexadecimal digits (0-9A-F).
r id is the id in reverse order, which is often used in other applications and labeling.
locator
r_locator
read-only, ascii
Uses an extension of the 1-wire design from iButtonLink company that associated 1-wire physical
connections with a unique 1-wire code. If the connection is behind a Link Locator the locator will show a
unique 8-byte number (16 character hexadecimal) starting with family code FE.
If no Link Locator is between the device and the master, the locator field will be all FF.
r locator is the locator in reverse order.
present (DEPRECATED)
read-only, yes-no
Is the device currently present on the 1-wire bus?
type
read-only, ascii
Part name assigned by Dallas Semi. E.g. DS2401 Alternative packaging (iButton vs chip) will not be
distiguished.
ALARMS
None.
DESCRIPTION
1-Wire
1-wire is a wiring protocol and series of devices designed and manufactured by Dallas Semiconductor, Inc.
The bus is a low-power low-speed low-connector scheme where the data line can also provide power.
Each device is uniquely and unalterably numbered during manufacture. There are a wide variety of devices,
including memory, sensors (humidity, temperature, voltage, contact, current), switches, timers and data
loggers. More complex devices (like thermocouple sensors) can be built with these basic devices. There
are also 1-wire devices that have encryption included.
The 1-wire scheme uses a single bus master and multiple slaves on the same wire. The bus master initiates
all communication. The slaves can be individually discovered and addressed using their unique ID.
Bus masters come in a variety of configurations including serial, parallel, i2c, network or USB adapters.
OWFS design
OWFS is a suite of programs that designed to make the 1-wire bus and its devices easily accessible. The
underlying principle is to create a virtual filesystem, with the unique ID being the directory, and the
individual properties of the device are represented as simple files that can be read and written.
Details of the individual slave or master design are hidden behind a consistent interface. The goal is to
provide an easy set of tools for a software designer to create monitoring or control applications. There
are some performance enhancements in the implementation, including data caching, parallel access to bus
masters, and aggregation of device communication. Still the fundamental goal has been ease of use,
flexibility and correctness rather than speed.
ADDRESSING
All 1-wire devices are factory assigned a unique 64-bit address. This address is of the form:
Family Code
8 bits
Address
48 bits
CRC 8 bits
Addressing under OWFS is in hexadecimal, of form:
01.123456789ABC
where 01 is an example 8-bit family code, and 12345678ABC is an example 48 bit address.
The dot is optional, and the CRC code can included. If included, it must be correct.
DATASHEET
https://www.ibuttonlink.com/products/ss-wall-th
SEE ALSO
Programs
owfs (1) owhttpd (1) owftpd (1) owserver (1) owdir (1) owread (1) owwrite (1) owpresent (1) owtap (1)
Configuration and testing
owfs (5) owtap (1) owmon (1)
Language bindings
owtcl (3) owperl (3) owcapi (3)
Clocks
DS1427 (3) DS1904 (3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415 (3) DS2417 (3)
ID
DS2401 (3) DS2411 (3) DS1990A (3)
Memory
DS1982 (3) DS1985 (3) DS1986 (3) DS1991 (3) DS1992 (3) DS1993 (3) DS1995 (3) DS1996 (3) DS2430A (3)
DS2431 (3) DS2433 (3) DS2502 (3) DS2506 (3) DS28E04 (3) DS28EC20 (3)
Switches
DS2405 (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3) InfernoEmbedded (3)
Temperature
DS1822 (3) DS1825 (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3) DS1921 (3) DS1821 (3) DS28EA00 (3)
DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3) EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) MAX31826
(3)
Humidity
DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)
Voltage
DS2450 (3)
Resistance
DS2890 (3)
Multifunction (current, voltage, temperature)
DS2436 (3) DS2437 (3) DS2438 (3) DS2751 (3) DS2755 (3) DS2756 (3) DS2760 (3) DS2770 (3) DS2780 (3) DS2781
(3) DS2788 (3) DS2784 (3)
Counter
DS2423 (3)
LCD Screen
LCD (3) DS2408 (3)
Crypto
DS1977 (3)
Pressure
DS2406 (3) TAI8570 (3) EDS0066 (3) EDS0068 (3)
Moisture
EEEF (3) DS2438 (3)
AVAILABILITY
http://www.owfs.org
AUTHOR
Paul Alfille <paul.alfille@gmail.com> Jan Kandziora <jjj@gmx.de>
OWFS Manpage 2003 IBLSS(3)