Provided by: smokeping_2.8.2+ds-1_all 

NAME
Smokeping::probes::OpenSSHJunOSPing - Juniper SSH JunOS Probe for SmokePing
SYNOPSIS
*** Probes ***
+OpenSSHJunOSPing
forks = 5
offset = 50%
packetsize = 100
step = 300
timeout = 15
tos =
# The following variables can be overridden in each target section
/^influx_.+/ = influx_location = In the basement
junospass = password # mandatory
junosuser = user # mandatory
pings = 5
psource = 192.168.2.129
source = 192.168.2.1 # mandatory
# [...]
*** Targets ***
probe = OpenSSHJunOSPing # if this should be the default probe
# [...]
+ mytarget
# probe = OpenSSHJunOSPing # if the default probe is something else
host = my.host
/^influx_.+/ = influx_location = In the basement
junospass = password # mandatory
junosuser = user # mandatory
pings = 5
psource = 192.168.2.129
source = 192.168.2.1 # mandatory
DESCRIPTION
Connect to Juniper JunOS via OpenSSH to run ping commands. This probe uses the "extended ping" of the
Juniper JunOS. You have the option to specify which interface the ping is sourced from as well.
VARIABLES
Supported probe-specific variables:
forks
Run this many concurrent processes at maximum
Example value: 5
Default value: 5
offset
If you run many probes concurrently you may want to prevent them from hitting your network all at the
same time. Using the probe-specific offset parameter you can change the point in time when each probe
will be run. Offset is specified in % of total interval, or alternatively as 'random', and the offset
from the 'General' section is used if nothing is specified here. Note that this does NOT influence
the rrds itself, it is just a matter of when data acquisition is initiated. (This variable is only
applicable if the variable 'concurrentprobes' is set in the 'General' section.)
Example value: 50%
packetsize
The (optional) packetsize option lets you configure the packetsize for the pings sent.
Default value: 100
step
Duration of the base interval that this probe should use, if different from the one specified in the
'Database' section. Note that the step in the RRD files is fixed when they are originally generated,
and if you change the step parameter afterwards, you'll have to delete the old RRD files or somehow
convert them. (This variable is only applicable if the variable 'concurrentprobes' is set in the
'General' section.)
Example value: 300
timeout
How long a single 'ping' takes at maximum
Example value: 15
Default value: 5
tos The (optional) type of service for the pings sent.
Supported target-specific variables:
/^influx_.+/
This is a tag that will be sent to influxdb and has no impact on the probe measurement. The tag name
will be sent without the "influx_" prefix, which will be replaced with "tag_" instead. Tags can be
used for filtering.
Example value: influx_location = In the basement
junospass
The junospass option allows you to specify the password for the username specified with the option
junosuser.
Example value: password
This setting is mandatory.
junosuser
The junosuser option allows you to specify a username that has ping capability on the JunOS Device.
Example value: user
This setting is mandatory.
pings
How many pings should be sent to each target, if different from the global value specified in the
Database section. Note that the number of pings in the RRD files is fixed when they are originally
generated, and if you change this parameter afterwards, you'll have to delete the old RRD files or
somehow convert them.
Example value: 5
psource
The (optional) psource option specifies an alternate IP address or Interface from which you wish to
source your pings from. Routers can have many many IP addresses, and interfaces. When you ping from
a router you have the ability to choose which interface and/or which IP address the ping is sourced
from. Specifying an IP/interface does not necessarily specify the interface from which the ping will
leave, but will specify which address the packet(s) appear to come from. If this option is left out
the JunOS Device will source the packet automatically based on routing and/or metrics. If this
doesn't make sense to you then just leave it out.
Example value: 192.168.2.129
source
The source option specifies the JunOS device that is going to run the ping commands. This address
will be used for the ssh connection.
Example value: 192.168.2.1
This setting is mandatory.
AUTHORS
Tobias Oetiker <tobi@oetiker.ch>
based on Smokeping::probes::TelnetJunOSPing by S H A N <shanali@yahoo.com>.
NOTES
JunOS configuration
The JunOS device should have a username/password configured, as well as the ability to connect to the
VTY(s).
Make sure to connect to the remote host once from the command line as the user who is running smokeping.
On the first connect ssh will ask to add the new host to its known_hosts file. This will not happen
automatically so the script will fail to login until the ssh key of your juniper box is in the
known_hosts file.
Some JunOS devices have a maximum of 5 VTYs available, so be careful not to hit a limit with the 'forks'
variable.
Requirements
This module requires the Net::OpenSSH and IO::Pty.
2.8.2 2024-02-04 Smokeping_probes_OpenSSHJunOSPing(3)