Provided by: owfs-doc_3.2p4+dfsg1-4.3build2_all 

NAME
InfernoEmbedded
- InfernoEmbedded Softdevices: RGBW Controllers, Switch Masters, Firmware Updater
SYNOPSIS
Software-implemented devices based on https://github.com/InfernoEmbedded/onewire-softdevice
ED [.]XXXXXXXXXXXX[XX][/[ device | version | status | enter_firmware_update | address | crc8 | id |
locator | r_address | r_id | r_locator | type ]]
FAMILY CODE
ED
GENERIC PROPERTIES
These properties are applicable to all Inferno Embedded softdevices.
device
read-only, ascii text
The type of InfernoEmbedded Softdevice detected.
version
read-only, integer
The version number reported by the device.
status
read-only, integer
The 64 bit status register of the device.
enter_firmware_update
write-only, yes-no
Write anything to reboot the device into the bootloader for firmware update. This may also be forced if
you have physical access to the device by shorting SWCLK to ground on the device's programming header
when powering up the device.
FIRMWARE UPDATER PROPERTIES
These properties are available when the device has entered firmware update mode.
firmware_bootloader_size
read-only, integer
The reserved size for the bootloader.
firmware_range
read-only, ascii text
The range of addresses available for the application (0xNNNN-0xNNNN).
erase_firmware
write-only, yes-no
Write anything to erase the current application and prepare the device to accept a new firmware.
update_firmware
write-only, binary data
Write the binary data for a firmware update here to reprogram the device after erasing.
exit_firmware_update
write-only, yes-no
Write anything to exit firmware update and start the application.
RGBW CONTROLLER PROPERTIES
These controllers control a number of channels of RGBW lights.
rgbw_all_off
write-only, yes-no
Write anything to turn off all channels
rgbw_channels
read-only, integer
The number of RGBW channels supported by this device.
rgbw_channelNN
read-write, ascii text
Set the current value of channel NN, as: RRR,GGG,BBB,WWW,nnn where:
RRR,GGG,BBB,WWW is the red, green, blue values respectively (0-255)
nnn is the time to fade from the current colour to the new one, in milliseconds (0-16M). On read, this
is time remaining for the current fade to complete.
SWITCH MASTERS
These devices have a number of indicator LEDs, switch inputs and relay outputs. Each are grouped into
ports of a certain number of channels.
switch_ports
read-only, integer
The number of switch ports available.
switch_channels
read-only, integer
The number of channels available per switch port.
switch_refresh_activations
write-only, yes-no
Write anything here to update the values of all switch ports from the device.
switch_portN
read-only, ascii text
The last fetched state for the port (use switch_refresh_activations to fetch the state). Formatted as
"channel0,channel1...channelN", where each channel is '0' or '1' depending on whether it is activated.
set_switch_type
write-only, ascii text
Sets the type of switch connected to the device. Format "port,channel,type" where port and channel are
integer IDs, and type is:
0 Toggle switch to VCC with pull-downs enabled on the device
1 Toggle switch to Gnd with pull-ups enabled on the device
2 Momentary switch to VCC with pull-downs enabled on the device
3 Momentary switch to Gnd with pull-ups enabled on the device
led_ports
read-only, integer
The number of LED ports available.
led_channels
read-only, integer
The number of channels available per LED port.
led_portN
read-write, ascii text
The state for the port. Formatted as "channel0,channel1...channelN", where each channel is '0' or '1'
depending on whether the LED is lit.
relay_ports
read-only, integer
The number of relay ports available.
relay_channels
read-only, integer
The number of channels available per relay port.
relay_portN
read-write, ascii text
The state for the port. Formatted as "channel0,channel1...channelN", where each channel is '0' or '1'
depending on whether the relay is activated.
relay_modeN
read-write, ascii text
The mode for each relay on the port. Formatted as "channel0,channel1...channelN", where each channel is
one of the following modes:
0 Channel operates independently
1 Channel operates as a member of an even/odd pair
If the channels are operated as pairs, the even numbered relay is activated when the even numbered
channel is turned on, and the odd numbered relay is activated when the even numbered channel is turned
off. The odd numbered channel has no effect. This is useful when controlling devices such as roller
shutters, projector screens and air conditioning dampers, which require one relay to be activated to
open, and another to close.
relay_timeoutN
read-write, ascii text
The timeout for each relay on the port. Formatted as "channel0,channel1...channelN", where each channel
is an integer (0-255) representing the number of seconds the relay will remain activated when operating
as an even/odd pair.
ADDRESSING
All 1-wire devices are factory assigned a unique 64-bit address. This address is of the form:
Family Code
8 bits
Address
48 bits
CRC 8 bits
Addressing under OWFS is in hexadecimal, of form:
01.123456789ABC
where 01 is an example 8-bit family code, and 12345678ABC is an example 48 bit address.
The dot is optional, and the CRC code can included. If included, it must be correct.
SEE ALSO
Programs
owfs (1) owhttpd (1) owftpd (1) owserver (1) owdir (1) owread (1) owwrite (1) owpresent (1) owtap (1)
Configuration and testing
owfs (5) owtap (1) owmon (1)
Language bindings
owtcl (3) owperl (3) owcapi (3)
Clocks
DS1427 (3) DS1904 (3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415 (3) DS2417 (3)
ID
DS2401 (3) DS2411 (3) DS1990A (3)
Memory
DS1982 (3) DS1985 (3) DS1986 (3) DS1991 (3) DS1992 (3) DS1993 (3) DS1995 (3) DS1996 (3) DS2430A (3)
DS2431 (3) DS2433 (3) DS2502 (3) DS2506 (3) DS28E04 (3) DS28EC20 (3)
Switches
DS2405 (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3) InfernoEmbedded (3)
Temperature
DS1822 (3) DS1825 (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3) DS1921 (3) DS1821 (3) DS28EA00 (3)
DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3) EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) MAX31826
(3)
Humidity
DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)
Voltage
DS2450 (3)
Resistance
DS2890 (3)
Multifunction (current, voltage, temperature)
DS2436 (3) DS2437 (3) DS2438 (3) DS2751 (3) DS2755 (3) DS2756 (3) DS2760 (3) DS2770 (3) DS2780 (3) DS2781
(3) DS2788 (3) DS2784 (3)
Counter
DS2423 (3)
LCD Screen
LCD (3) DS2408 (3)
Crypto
DS1977 (3)
Pressure
DS2406 (3) TAI8570 (3) EDS0066 (3) EDS0068 (3)
Moisture
EEEF (3) DS2438 (3)
AVAILABILITY
https://github.com/InfernoEmbedded/onewire-softdevice
AUTHOR
Alastair D'Silva (alastair@d-silva.org)
OWFS Manpage 2018 InfernoEmbedded(3)