NAME

       sane-coolscan3 - SANE backend for Nikon Coolscan film scanners

DESCRIPTION

       The  sane-coolscan3  library  implements  a  SANE  (Scanner  Access Now Easy) backend that
       provides access to Nikon Coolscan film scanners.  Some functions of this backend should be
       considered  beta-quality software. Most functions have been stable for a long time, but of
       course new development can not and will not function properly from the very first day.

       At present, the following scanners are known to work with this backend:

              Model:                       Connection Type
              ---------------------------  -------------------
              LS-30 (Coolscan III)         SCSI
              LS-40 ED (Coolscan IV)       USB
              LS-50 ED (Coolscan V)        USB
              LS-2000                      SCSI
              LS-4000 ED                   IEEE 1394
              LS-8000 ED                   IEEE 1394

       Please send mail to sane-devel@alioth-lists.debian.net to report successes or failures.

OPTIONS

       The options the backend supports can either be selected through command  line  options  to
       programs like scanimage(1) or through GUI elements in xscanimage(1) or xsane(1).

       Valid command line options and their syntax can be listed by using:

              scanimage --help -d coolscan3:<interface>:<device>

       where  <interface>  and  <device>  specify the device in question, as in the configuration
       file (see next section). The -d parameter and  its  argument  can  be  omitted  to  obtain
       information on the first scanner identified. Use the command:

              scanimage -L

       to list all devices recognized by your SANE installation.

       The  options  should  be fully described by the description or tooltips given by frontend.
       Here is a description of some of the most important options, in the syntax with which they
       must be supplied to scanimage(1):

       --frame <n>
              This  option  specifies which frame to operate on, if a motorized film strip feeder
              or APS adapter are used. The frame number <n> ranges from 1 to the number of frames
              available,  which is sensed each time the backend is initialized (usually each time
              you start the frontend).

       --subframe <x>
              This option shifts the scan window by the specified amount (default unit is mm).

       --infrared=yes/no
              If set to "yes", the scanner will read the infrared channel, thus  allowing  defect
              removal  in  software.  The  infrared  image  is read during a second scan, with no
              options altered. The backend must not be restarted between the scans.  If  you  use
              scanimage(1),   perform  a  batch  scan  with  --batch-count=2  to  obtain  the  IR
              information.

       --depth <n>
              Here <n> can either be 8 or the maximum number of bits  supported  by  the  scanner
              (10,  12,  or 14). It specifies whether or not the scanner reduces the scanned data
              to 8 bits before sending it to the backend. If 8 bits are  used,  some  information
              and  thus  image  quality  is  lost,  but the amount of data is smaller compared to
              higher depths. Also, many imaging programs and image formats cannot  handle  depths
              greater than 8 bits.

       --autofocus
              Perform  autofocus  operation.  Unless  otherwise  specified by the other options (
              --focus-on-centre and friends), focusing is performed on the centre of the selected
              scan area.

       --ae-wb

       --ae   Perform  a  pre-scan  to  calculate  exposure  values  automatically.  --ae-wb will
              maintain the white balance, while --ae will adjust each channel separately.

       --exposure
              Multiply all exposure times  with  this  value.  This  allows  exposure  correction
              without modifying white balance.

       --load Load the next slide when using the slide loader (SF-200 bulk loader only).

       --eject
              Eject the film strip or mounted slide when using the slide loader.

       --reset
              Reset scanner. The scanner will perform the same action as when power is turned on:
              it will eject the slide (with the SF-200 bulk loader)  and  calibrate  itself.  Use
              this  whenever  the  scanner refuses to load a slide properly, as a result of which
              --eject does not work.

CONFIGURATION FILE

       The configuration file /etc/sane.d/coolscan3.conf specifies the device(s) that the backend
       will  use. Owing to the nature of the supported connection types SCSI, USB, and IEEE 1394,
       the default configuration file supplied with the SANE  distribution  should  work  without
       being edited.

       Each  line  in  the  configuration  file is either of the following, where all entries are
       case-sensitive:

       blank or starting with a '#' character
              These lines are ignored, thus '#' can be used to include comments.

       containing only the word "auto"
              This instructs the backend to probe for a scanner by scanning the buses for devices
              with  known  identifiers.  This is the default action when no configuration file is
              present.

       a line of the form <interface>:<device>
              Here <interface> can be one of "scsi" or "usb", and <device> is the device file  of
              the  scanner.  Note  that  IEEE 1394 devices are handled by the SBP-2 module in the
              kernel and appear to SANE as SCSI devices.

FILES

       /usr/lib/x86_64-linux-gnu/sane/libsane-coolscan3.a
              The static library implementing this backend.

       /usr/lib/x86_64-linux-gnu/sane/libsane-coolscan3.so
              The shared library implementing this  backend  (present  on  systems  that  support
              dynamic loading).

       /etc/sane.d/coolscan3.conf
              Configuration file for this backend, read each time the backend is initialized.

ENVIRONMENT

       SANE_DEBUG_COOLSCAN3
              If  the  library was compiled with debug support enabled, this environment variable
              controls the debug level for this backend.  E.g., a value of 128 requests all debug
              output to be printed.  Smaller levels reduce verbosity.

SEE ALSO

       sane-scsi(5), sane-usb(5), scanimage(1), xscanimage(1), xsane(1)

BUGS

       Currently,  the  SANE  protocol does not allow automatically updating options whenever the
       hardware changes. Thus the number of choices for the --frame option will be fixed when the
       backend  is initialized (usually when the user runs the frontend). In particular, if there
       is no film strip in the automatic film strip feeder when the backend is  initialized,  the
       --frame  option will not appear at all.  Also, restarting the frontend after swapping film
       adapters is strongly recommended.

       Linux kernels prior to 2.4.19 had a patch that  truncated  INQUIRY  data  from  IEEE  1394
       scanners to 36 bytes, discarding vital information about the scanner. The IEEE 1394 models
       therefore only work with 2.4.19 or later.

       No real bugs currently known, please report any to the SANE developers' list.