Provided by: systemd_256.5-2ubuntu3_amd64 bug

NAME

       systemd.timer - Timer unit configuration

SYNOPSIS

       timer.timer

DESCRIPTION

       A unit configuration file whose name ends in ".timer" encodes information about a timer
       controlled and supervised by systemd, for timer-based activation.

       This man page lists the configuration options specific to this unit type. See
       systemd.unit(5) for the common options of all unit configuration files. The common
       configuration items are configured in the generic [Unit] and [Install] sections. The timer
       specific configuration options are configured in the [Timer] section.

       For each timer file, a matching unit file must exist, describing the unit to activate when
       the timer elapses. By default, a service by the same name as the timer (except for the
       suffix) is activated. Example: a timer file foo.timer activates a matching service
       foo.service. The unit to activate may be controlled by Unit= (see below).

       Note that in case the unit to activate is already active at the time the timer elapses it
       is not restarted, but simply left running. There is no concept of spawning new service
       instances in this case. Due to this, services with RemainAfterExit=yes set (which stay
       around continuously even after the service's main process exited) are usually not suitable
       for activation via repetitive timers, as they will only be activated once, and then stay
       around forever. Target units, which by default do not deactivate on their own, can be
       activated repeatedly by timers by setting StopWhenUnneeded=yes on them. This will cause a
       target unit to be stopped immediately after its activation, if it is not a dependency of
       another running unit.

AUTOMATIC DEPENDENCIES

   Implicit Dependencies
       The following dependencies are implicitly added:

       •   Timer units automatically gain a Before= dependency on the service they are supposed
           to activate.

   Default Dependencies
       The following dependencies are added unless DefaultDependencies=no is set:

       •   Timer units will automatically have dependencies of type Requires= and After= on
           sysinit.target, a dependency of type Before= on timers.target, as well as Conflicts=
           and Before= on shutdown.target to ensure that they are stopped cleanly prior to system
           shutdown. Only timer units involved with early boot or late system shutdown should
           disable the DefaultDependencies= option.

       •   Timer units with at least one OnCalendar= directive acquire a pair of additional
           After= dependencies on time-set.target and time-sync.target, in order to avoid being
           started before the system clock has been correctly set. See systemd.special(7) for
           details on these two targets.

OPTIONS

       Timer unit files may include [Unit] and [Install] sections, which are described in
       systemd.unit(5).

       Timer unit files must include a [Timer] section, which carries information about the timer
       it defines. The options specific to the [Timer] section of timer units are the following:

       OnActiveSec=, OnBootSec=, OnStartupSec=, OnUnitActiveSec=, OnUnitInactiveSec=
           Defines monotonic timers relative to different starting points:

           Table 1. Settings and their starting points
           ┌───────────────────┬──────────────────────────────────┐
           │SettingMeaning                          │
           ├───────────────────┼──────────────────────────────────┤
           │OnActiveSec=       │ Defines a timer relative to the  │
           │                   │ moment the timer unit itself is  │
           │                   │ activated.                       │
           ├───────────────────┼──────────────────────────────────┤
           │OnBootSec=         │ Defines a timer relative to when │
           │                   │ the machine was booted up. In    │
           │                   │ containers, for the system       │
           │                   │ manager instance, this is mapped │
           │                   │ to OnStartupSec=, making both    │
           │                   │ equivalent.                      │
           ├───────────────────┼──────────────────────────────────┤
           │OnStartupSec=      │ Defines a timer relative to when │
           │                   │ the service manager was first    │
           │                   │ started. For system timer units  │
           │                   │ this is very similar to          │
           │                   │ OnBootSec= as the system service │
           │                   │ manager is generally started     │
           │                   │ very early at boot. It's         │
           │                   │ primarily useful when configured │
           │                   │ in units running in the per-user │
           │                   │ service manager, as the user     │
           │                   │ service manager is generally     │
           │                   │ started on first login only, not │
           │                   │ already during boot.             │
           ├───────────────────┼──────────────────────────────────┤
           │OnUnitActiveSec=   │ Defines a timer relative to when │
           │                   │ the unit the timer unit is       │
           │                   │ activating was last activated.   │
           ├───────────────────┼──────────────────────────────────┤
           │OnUnitInactiveSec= │ Defines a timer relative to when │
           │                   │ the unit the timer unit is       │
           │                   │ activating was last deactivated. │
           └───────────────────┴──────────────────────────────────┘
           Multiple directives may be combined of the same and of different types, in which case
           the timer unit will trigger whenever any of the specified timer expressions elapse.
           For example, by combining OnBootSec= and OnUnitActiveSec=, it is possible to define a
           timer that elapses in regular intervals and activates a specific service each time.
           Moreover, both monotonic time expressions and OnCalendar= calendar expressions may be
           combined in the same timer unit.

           The arguments to the directives are time spans configured in seconds. Example:
           "OnBootSec=50" means 50s after boot-up. The argument may also include time units.
           Example: "OnBootSec=5h 30min" means 5 hours and 30 minutes after boot-up. For details
           about the syntax of time spans, see systemd.time(7).

           If a timer configured with OnBootSec= or OnStartupSec= is already in the past when the
           timer unit is activated, it will immediately elapse and the configured unit is
           started. This is not the case for timers defined in the other directives.

           These are monotonic timers, independent of wall-clock time and timezones. If the
           computer is temporarily suspended, the monotonic clock generally pauses, too. Note
           that if WakeSystem= is used, a different monotonic clock is selected that continues to
           advance while the system is suspended and thus can be used as the trigger to resume
           the system.

           If the empty string is assigned to any of these options, the list of timers is reset
           (both monotonic timers and OnCalendar= timers, see below), and all prior assignments
           will have no effect.

           Note that timers do not necessarily expire at the precise time configured with these
           settings, as they are subject to the AccuracySec= setting below.

       OnCalendar=
           Defines realtime (i.e. wallclock) timers with calendar event expressions. See
           systemd.time(7) for more information on the syntax of calendar event expressions.
           Otherwise, the semantics are similar to OnActiveSec= and related settings.

           Note that timers do not necessarily expire at the precise time configured with this
           setting, as it is subject to the AccuracySec= setting below.

           May be specified more than once, in which case the timer unit will trigger whenever
           any of the specified expressions elapse. Moreover calendar timers and monotonic timers
           (see above) may be combined within the same timer unit.

           If the empty string is assigned to any of these options, the list of timers is reset
           (both OnCalendar= timers and monotonic timers, see above), and all prior assignments
           will have no effect.

           Note that calendar timers might be triggered at unexpected times if the system's
           realtime clock is not set correctly. Specifically, on systems that lack a
           battery-buffered Realtime Clock (RTC) it might be wise to enable
           systemd-time-wait-sync.service to ensure the clock is adjusted to a network time
           source before the timer event is set up. Timer units with at least one OnCalendar=
           expression are automatically ordered after time-sync.target, which
           systemd-time-wait-sync.service is ordered before.

           When a system is temporarily put to sleep (i.e. system suspend or hibernation) the
           realtime clock does not pause. When a calendar timer elapses while the system is
           sleeping it will not be acted on immediately, but once the system is later resumed it
           will catch up and process all timers that triggered while the system was sleeping.
           Note that if a calendar timer elapsed more than once while the system was continuously
           sleeping the timer will only result in a single service activation. If WakeSystem=
           (see below) is enabled a calendar time event elapsing while the system is suspended
           will cause the system to wake up (under the condition the system's hardware supports
           time-triggered wake-up functionality).

           Added in version 197.

       AccuracySec=
           Specify the accuracy the timer shall elapse with. Defaults to 1min. The timer is
           scheduled to elapse within a time window starting with the time specified in
           OnCalendar=, OnActiveSec=, OnBootSec=, OnStartupSec=, OnUnitActiveSec= or
           OnUnitInactiveSec= and ending the time configured with AccuracySec= later. Within this
           time window, the expiry time will be placed at a host-specific, randomized, but stable
           position that is synchronized between all local timer units. This is done in order to
           optimize power consumption to suppress unnecessary CPU wake-ups. To get best accuracy,
           set this option to 1us. Note that the timer is still subject to the timer slack
           configured via systemd-system.conf(5)'s TimerSlackNSec= setting. See prctl(2) for
           details. To optimize power consumption, make sure to set this value as high as
           possible and as low as necessary.

           Note that this setting is primarily a power saving option that allows coalescing CPU
           wake-ups. It should not be confused with RandomizedDelaySec= (see below) which adds a
           random value to the time the timer shall elapse next and whose purpose is the
           opposite: to stretch elapsing of timer events over a longer period to reduce workload
           spikes. For further details and explanations and how both settings play together, see
           below.

           Added in version 209.

       RandomizedDelaySec=
           Delay the timer by a randomly selected, evenly distributed amount of time between 0
           and the specified time value. Defaults to 0, indicating that no randomized delay shall
           be applied. Each timer unit will determine this delay randomly before each iteration,
           and the delay will simply be added on top of the next determined elapsing time, unless
           modified with FixedRandomDelay=, see below.

           This setting is useful to stretch dispatching of similarly configured timer events
           over a certain time interval, to prevent them from firing all at the same time,
           possibly resulting in resource congestion.

           Note the relation to AccuracySec= above: the latter allows the service manager to
           coalesce timer events within a specified time range in order to minimize wakeups,
           while this setting does the opposite: it stretches timer events over an interval, to
           make it unlikely that they fire simultaneously. If RandomizedDelaySec= and
           AccuracySec= are used in conjunction, first the randomized delay is added, and then
           the result is possibly further shifted to coalesce it with other timer events
           happening on the system. As mentioned above AccuracySec= defaults to 1 minute and
           RandomizedDelaySec= to 0, thus encouraging coalescing of timer events. In order to
           optimally stretch timer events over a certain range of time, set AccuracySec=1us and
           RandomizedDelaySec= to some higher value.

           Added in version 229.

       FixedRandomDelay=
           Takes a boolean argument. When enabled, the randomized offset specified by
           RandomizedDelaySec= is reused for all firings of the same timer. For a given timer
           unit, the offset depends on the machine ID, user identifier and timer name, which
           means that it is stable between restarts of the manager. This effectively creates a
           fixed offset for an individual timer, reducing the jitter in firings of this timer,
           while still avoiding firing at the same time as other similarly configured timers.

           This setting has no effect if RandomizedDelaySec= is set to 0. Defaults to false.

           Added in version 247.

       OnClockChange=, OnTimezoneChange=
           These options take boolean arguments. When true, the service unit will be triggered
           when the system clock (CLOCK_REALTIME) jumps relative to the monotonic clock
           (CLOCK_MONOTONIC), or when the local system timezone is modified. These options can be
           used alone or in combination with other timer expressions (see above) within the same
           timer unit. These options default to false.

           Added in version 242.

       Unit=
           The unit to activate when this timer elapses. The argument is a unit name, whose
           suffix is not ".timer". If not specified, this value defaults to a service that has
           the same name as the timer unit, except for the suffix. (See above.) It is recommended
           that the unit name that is activated and the unit name of the timer unit are named
           identically, except for the suffix.

       Persistent=
           Takes a boolean argument. If true, the time when the service unit was last triggered
           is stored on disk. When the timer is activated, the service unit is triggered
           immediately if it would have been triggered at least once during the time when the
           timer was inactive. Such triggering is nonetheless subject to the delay imposed by
           RandomizedDelaySec=. This is useful to catch up on missed runs of the service when the
           system was powered down. Note that this setting only has an effect on timers
           configured with OnCalendar=. Defaults to false.

           Use systemctl clean --what=state ...  on the timer unit to remove the timestamp file
           maintained by this option from disk. In particular, use this command before
           uninstalling a timer unit. See systemctl(1) for details.

           Added in version 212.

       WakeSystem=
           Takes a boolean argument. If true, an elapsing timer will cause the system to resume
           from suspend, should it be suspended and if the system supports this. Note that this
           option will only make sure the system resumes on the appropriate times, it will not
           take care of suspending it again after any work that is to be done is finished.
           Defaults to false.

           Note that this functionality requires privileges and is thus generally only available
           in the system service manager.

           Note that behaviour of monotonic clock timers (as configured with OnActiveSec=,
           OnBootSec=, OnStartupSec=, OnUnitActiveSec=, OnUnitInactiveSec=, see above) is altered
           depending on this option. If false, a monotonic clock is used that is paused during
           system suspend (CLOCK_MONOTONIC), if true a different monotonic clock is used that
           continues advancing during system suspend (CLOCK_BOOTTIME), see clock_getres(2) for
           details.

           Added in version 212.

       RemainAfterElapse=
           Takes a boolean argument. If true, a timer will stay loaded, and its state remains
           queryable even after it elapsed and the associated unit (as configured with Unit=, see
           above) deactivated again. If false, an elapsed timer unit that cannot elapse anymore
           is unloaded once its associated unit deactivated again. Turning this off is
           particularly useful for transient timer units. Note that this setting has an effect
           when repeatedly starting a timer unit: if RemainAfterElapse= is on, starting the timer
           a second time has no effect. However, if RemainAfterElapse= is off and the timer unit
           was already unloaded, it can be started again, and thus the service can be triggered
           multiple times. Defaults to true.

           Added in version 229.

       Check systemd.unit(5), systemd.exec(5), and systemd.kill(5) for more settings.

SEE ALSO

       Environment variables with details on the trigger will be set for triggered units. See the
       "Environment Variables Set or Propagated by the Service Manager" section in
       systemd.exec(5) for more details.

       systemd(1), systemctl(1), systemd.unit(5), systemd.service(5), systemd.time(7),
       systemd.directives(7), systemd-system.conf(5), prctl(2)