oracular (5) xl-network-configuration.5.gz

Provided by: xen-utils-common_4.17.3+10-g091466ba55-1.1ubuntu3_amd64 bug

NAME

       xl-network-configuration - XL Network Configuration Syntax

SYNTAX

       This document specifies the xl config file format vif configuration option.  It has the following form:

               vif = [ '<vifspec>', '<vifspec>', ... ]

       where each vifspec is in this form:

               [<key>=<value>|<flag>,]

       For example:

               'mac=00:16:3E:74:3d:76,model=rtl8139,bridge=xenbr0'
               'mac=00:16:3E:74:34:32'
               '' # The empty string

       These might be specified in the domain config file like this:

               vif = [ 'mac=00:16:3E:74:34:32', 'mac=00:16:3e:5f:48:e4,bridge=xenbr1' ]

       More formally, the string is a series of comma-separated keyword/value pairs. All keywords are optional.

       Each device has a "DEVID" which is its index within the vif list, starting from 0.

Keywords

   mac
       If specified then this option specifies the MAC address inside the guest of this VIF device. The value is
       a 48-bit number represented as six groups of two hexadecimal digits, separated by colons (:).

       The default if this keyword is not specified is to be automatically generate a MAC address inside the
       space assigned to Xen's Organizationally Unique Identifier
       <https://en.wikipedia.org/wiki/Organizationally_Unique_Identifier> (00:16:3e).

       If you are choosing a MAC address then it is strongly recommend to follow one of the following
       strategies:

       •   Generate a random sequence of 6 byte, set the locally administered bit (bit 2 of the first byte) and
           clear the multicast bit (bit 1 of the first byte). In other words the first byte should have the bit
           pattern xxxxxx10 (where x is a randomly generated bit) and the remaining 5 bytes are randomly
           generated See [https://en.wikipedia.org/wiki/MAC_address] for more details the structure of a MAC
           address.

       •   Allocate an address from within the space defined by your organization's OUI (if you have one)
           following your organization's procedures for doing so.

       •   Allocate an address from within the space defined by Xen's OUI (00:16:3e). Taking care not to clash
           with other users of the physical network segment where this VIF will reside.

       If you have an OUI for your own use then that is the preferred strategy. Otherwise in general you should
       prefer to generate a random MAC and set the locally administered bit since this allows for more bits of
       randomness than using the Xen OUI.

   bridge
       Specifies the name of the network bridge which this VIF should be added to. The default is "xenbr0". The
       bridge must be configured using your distribution's network configuration tools. See the wiki
       <https://wiki.xenproject.org/wiki/Network_Configuration_Examples_(Xen_4.1%2B)> for guidance and examples.

   gatewaydev
       Specifies the name of the network interface which has an IP and which is in the network the VIF should
       communicate with. This is used in the host by the vif-route hotplug script. See wiki
       <https://wiki.xenproject.org/wiki/Vif-route> for guidance and examples.

       NOTE: netdev is a deprecated alias of this option.

   type
       This keyword is valid for HVM guests only.

       Specifies the type of device to valid values are:

       •   "ioemu" (default) -- this device will be provided as an emulate device to the guest and also as a
           paravirtualised device which the guest may choose to use instead if it has suitable drivers
           available.

       •   "vif" -- this device will be provided as a paravirtualised device only.

   model
       This keyword is valid for HVM guest devices with "type=ioemu" only.

       Specifies the type device to emulated for this guest. Valid values are:

       •   "rtl8139" (default) -- Realtek RTL8139

       •   "e1000" -- Intel E1000

       •   in principle any device supported by your device model

   vifname
       Specifies the backend device name for the virtual device.

       If the domain is an HVM domain then the associated emulated (tap) device will have a "-emu" suffice
       added.

       The default name for the virtual device is "vifDOMID.DEVID" where "DOMID" is the guest domain ID and
       "DEVID" is the device number. Likewise the default tap name is "vifDOMID.DEVID-emu".

   script
       Specifies the hotplug script to run to configure this device (e.g. to add it to the relevant bridge).
       Defaults to "/etc/xen/scripts/vif-bridge" but can be set to any script. Some example scripts are
       installed in "/etc/xen/scripts".

       Note on NetBSD HVM guests will ignore the script option for tap (emulated) interfaces and always use
       "XEN_SCRIPT_DIR/qemu-ifup" to configure the interface in bridged mode.

   ip
       Specifies the IP address for the device, the default is not to specify an IP address.

       What, if any, effect this has depends on the hotplug script which is configured. A typically behaviour
       (exhibited by the example hotplug scripts) if set might be to configure firewall rules to allow only the
       specified IP address to be used by the guest (blocking all others).

   backend
       Specifies the backend domain which this device should attach to. This defaults to domain 0.  Specifying
       another domain requires setting up a driver domain which is outside the scope of this document.

   rate
       Specifies the rate at which the outgoing traffic will be limited to.  The default if this keyword is not
       specified is unlimited.

       The rate may be specified as "/s" or optionally "/s@".

       •   "RATE" is in bytes and can accept suffixes:

           •   GB, MB, KB, B for bytes.

           •   Gb, Mb, Kb, b for bits.

       •   "INTERVAL" is in microseconds and can accept suffixes: ms, us, s.  It determines the frequency at
           which the vif transmission credit is replenished. The default is 50ms.

       Vif rate limiting is credit-based. It means that for "1MB/s@20ms", the available credit will be
       equivalent of the traffic you would have done at "1MB/s" during 20ms. This will results in a credit of
       20,000 bytes replenished every 20,000 us.

       For example:

               'rate=10Mb/s' -- meaning up to 10 megabits every second
               'rate=250KB/s' -- meaning up to 250 kilobytes every second
               'rate=1MB/s@20ms' -- meaning 20,000 bytes in every 20 millisecond period

       NOTE: The actual underlying limits of rate limiting are dependent on the underlying netback
       implementation.

   devid
       Specifies the devid manually instead of letting xl choose the lowest index available.

       NOTE: This should not be set unless you have a reason to.

   mtu
       Specifies the MTU (i.e. the maximum size of an IP payload, exclusing headers). The default value is 1500
       but, if the VIF is attached to a bridge, it will be set to match unless overridden by this parameter.

   trusted / untrusted
       An advisory setting for the frontend driver on whether the backend should be trusted.  The frontend
       should deploy whatever protections it has available to prevent an untrusted backend from accessing guest
       data not related to the I/O processing or causing malfunction to the frontend or the whole domain.

       Note frontends can ignore such recommendation.