plucky (3) DS2438.3.gz

Provided by: owfs-doc_3.2p4+dfsg1-4.5build1_all bug

NAME

       DS2438 - Smart Battery Monitor

SYNOPSIS

   Temperature Voltages and Current.
       26  [.]XXXXXXXXXXXX[XX][/[  CA  |  EE  |  date  |  disconnect/date  | disconnect/udate | endcharge/date |
       endcharge/udate | IAD | offset | pages/page.[0-7|ALL] | temperature | latesttemp | udate | VAD  |  VDD  |
       vis | address | crc8 | id | locator | r_address | r_id | r_locator | type ]]

   Humidity sensor
       26  [.]XXXXXXXXXXXX[XX][/[  HIH4000/humidity  |  HIH5030/humidity  |  HTM1735/humidity  | DATANAB/reset |
       DATANAB/humidity | humidity | temperature ]]

   Barometer
       26 [.]XXXXXXXXXXXX[XX][/[ B1-R1-A/pressure | B1-R1-A/gain | B1-R1-A/offset | ]]

   Light
       26 [.]XXXXXXXXXXXX[XX][/[ S3-R1-A/current | S3-R1-A/illuminance | S3-R1-A/gain ]]

FAMILY CODE

       26

SPECIAL PROPERTIES

   pages/page.0 ... pages/page.7 pages/page.ALL
       read-write, binary
       Memory is split into 8 pages of 8 bytes each. Only the pages 3-7 are really available, and some  of  that
       appears to be reserved. See the datasheet for details.
       ALL is an aggregate of the pages. Each page is accessed sequentially.

   temperature
       read-only, floating point
       Temperature  read by the chip at high resolution (~13 bits). Units are selected from the invoking command
       line. See owfs(1) or owhttpd(1) for choices. Default is Celsius.  Conversion takes ~20 msec.

   latesttemp
       read-only, floating point
       Latest measured temperature. Reading this node will never trigger a temperature conversion. Intended  for
       use in conjunction with /simultaneous/temperature.

   VAD VDD
       read-only, floating point
       Voltage  read (~10 bits) at the one of the chip's two supply voltages. Range VDD= 2.4V to 10V, VAD=1.5 to
       10V.

   vis
       read-only, floating point
       Current sensor reading, as a voltage difference. Value is in volts.
       Actual current depends on Rsens resistor (see datasheet).
       The formula for current is I = vis / Rsens
       with units in Amps and Ohms.
       Current measurement will be temporarily enabled (see Ienable ) if not currently  enabled  (pun  intended)
       for this reading.

CONFIGURATION PROPERTIES

   CA
       read-write, yes-no
       Current  Accumulator  Configuration flag bit. If "on" (1) current is stored in page 7 bytes 4-7. If "off"
       (0) that page can be used for general storage. See the datasheet for more information.

   EE
       read-write, yes-no
       Current Accumulator Shadow flag bit. If "on" (1) current reading is stored to EEPROM. If "off"  (0)  that
       data will be lost when chip loses power. See the datasheet for more information

   IAD
       read-write, yes-no
       Current A/D Control flag bit. If "on" (1) current measured at 36.41 Hz. If "off" (0) current measurements
       won't be made. See the datasheet for more information.

DATE PROPERTIES

   date
       read-write, ascii
       26 character date representation of the counter value. Increments once per second.
       Setting date to a null string will put the current system time.
       Accepted date formats are:
         Sat[urday] March 12 12:23:59 2001
         Apr[il] 4 9:34:56 2002
         3/23/04 23:34:57
         current locale setting (your system's format)

   disconnect/date
       read-write, ascii
       26 character date representation of the disconnect/udate value. Time when the battery pack  waws  removed
       from the charger. Format is the same as the date property.

   disconnect/udate
       read-write, unsigned integer
       Representation of disconnect/date as a number. See udate for details.

   endcharge/date
       read-write, ascii
       26 character date representation of the endcharge/udate value. Format is the same as the date property.

   endcharge/udate
       read-write, unsigned integer
       Representation of endcharge/date as a number. See udate for details.

   udate
       read-write, unsigned integer
       Time represented as a number.  udate increments once per second.
       Usually  set  to unix time standard: number of seconds since Jan 1, 1970. The date field will be the unix
       representation (ascii text) of udate and setting either will change the other.

HUMIDITY PROPERTIES

   HIH4000/humidity
       read-only, floating point
       Relative humidity, as percent (1-100 scale).
       This value is for a design based on Honeywell's HIH-4000 humidity sensor.

   HIH5030/humidity
       read-only, floating point
       Relative humidity, as percent (1-100 scale).
       This value is for a design based on Honeywell's HIH-5030/5031 humidity sensor.

   HTM1735/humidity
       read-only, floating point
       Relative humidity, as percent (1-100 scale).
       This value is for a design based on Humirel's HTM-1735 humidity sensor.

   DATANAB/humidity
       read-only, floating point
       Based on DataNAB's humidity sensor. It uses a HIH-4000  sensor  and  the  current  sensning  rather  than
       voltage  readings  from the DS2438. Calibration values are stored on chip, and a check field is stored in
       chip memory.

   DATANAB/reset
       write-only, yes-no
       Used to read calibration values and set the chip to current reading more. Should be automatically  called
       when a humidity reading is requested.

   humidity
       read-only, floating point
       Relative humidity, as percent (1-100 scale).
       The  DS2438  actually  does not read humidity, but a widely available and publicised circuit based on the
       chip, does. This design is for the  common  Honeywell  HIH-3610  humidity  chip.  The  mostly  compatible
       HIH-4000 chip uses different temperature compensation, so is better read from the HIH4000/humidity value.
       See the datasheets for details.
       If the chip is instead a DATANAB design, the DATANAB/humidity value will be automatically used.

BAROMETER PROPERTIES

   B1-R1-A/pressure
       read-only, floating point
       Pressure reading, as milli-bars, or other unit depending on settings/units/pressure_scale.
       This value is for the B1-R1-A barometer from Hobby-Boards, and assumes the standard calibration.

   B1-R1-A/gain
       read/write, floating point
       Calibration of pressure gain, as signed number, expressed as the same units as B1-R1-A/pressure per volt.
       This value will be multiplied with the measured voltage to get the B1-R1-A/pressure reading. It may  have
       to  be  fine  tuned  for  calibration  purposes, although with the standard sensor, it will often be good
       enough to keep it as is.

   B1-R1-A/offset
       read/write, floating point
       Calibration of pressure offset, as signed number, same units as B1-R1-A/pressure.
       This value will be added to the B1-R1-A/pressure reading. The default value is 904.7 millibars, which may
       be altered to to compensate for elevation.

SOLAR SENSOR PROPERTIES

   S3-R1-A/current
       read-only, floating point
       Photo-diode current, in micro-amperes.
       This  value  is for the S3-R1-A solar radiation sensor from Hobby-Boards.  Due to noise and offsets, this
       value may read as a negative number in low light conditions.  The offset  register  can  be  modified  to
       reduce the offset as much as possible.

   S3-R1-A/illumination
       read-only, floating point
       Illumination, in lux. Always a positive number.
       This value is the lux reading from the solar sensor, taking S3-R1-A/gain into consideration.

   S3-R1-A/gain
       read/write, floating point
       Calibration of photo-diode gain expressed as lux per micro-amperes.  The default value is for the SFH203P
       photo-diode from Osram, used bare.  A different gain may be  used  for  instance  to  compensate  for  an
       integrathing, white sphere placed over the diode.
       This  value  is  for  the S3-R1-A solar radiation sensor from Hobby-Boards, using the SFH203P photo-diode
       from Osram.

MULTISENSOR PROPERTIES

   MultiSensor/type
       read-only, ascii
       For iButtonLink's MultiSensor line of 1-wire devices, give the specific configuration  based  on  a  data
       byte  set  in  memory.  (Byte  0  of  page  3).   This  can  help  interpretation  of  the sensor values,
       distinguishing, current from water from light.

   offset
       read-write, integer
       Correction for current readings. A value between -256 and 255. See the datasheet for details.  Should  be
       set to the negative of a true zero current reading.

STANDARD PROPERTIES

   address
   r_address
       read-only, ascii
       The entire 64-bit unique ID. Given as upper case hexadecimal digits (0-9A-F).
       address starts with the family code
       r address is the address in reverse order, which is often used in other applications and labeling.

   crc8
       read-only, ascii
       The  8-bit error correction portion. Uses cyclic redundancy check. Computed from the preceding 56 bits of
       the unique ID number. Given as upper case hexadecimal digits (0-9A-F).

   family
       read-only, ascii
       The 8-bit family code. Unique to each type of device. Given as upper case hexadecimal digits (0-9A-F).

   id
   r_id
       read-only, ascii
       The 48-bit middle portion of the unique ID number. Does not include the family  code  or  CRC.  Given  as
       upper case hexadecimal digits (0-9A-F).
       r id is the id in reverse order, which is often used in other applications and labeling.

   locator
   r_locator
       read-only, ascii
       Uses  an  extension  of  the  1-wire  design  from  iButtonLink  company  that associated 1-wire physical
       connections with a unique 1-wire code. If the connection is behind a Link Locator the locator will show a
       unique 8-byte number (16 character hexadecimal) starting with family code FE.
       If no Link Locator is between the device and the master, the locator field will be all FF.
       r locator is the locator in reverse order.

   present (DEPRECATED)
       read-only, yes-no
       Is the device currently present on the 1-wire bus?

   type
       read-only, ascii
       Part  name  assigned  by  Dallas  Semi.  E.g.  DS2401 Alternative packaging (iButton vs chip) will not be
       distiguished.

ALARMS

       None.

DESCRIPTION

   1-Wire
       1-wire is a wiring protocol and series of devices designed and manufactured by Dallas Semiconductor, Inc.
       The bus is a low-power low-speed low-connector scheme where the data line can also provide power.

       Each device is uniquely and unalterably numbered during manufacture. There are a wide variety of devices,
       including memory, sensors (humidity, temperature, voltage, contact, current), switches, timers  and  data
       loggers.  More  complex  devices (like thermocouple sensors) can be built with these basic devices. There
       are also 1-wire devices that have encryption included.

       The 1-wire scheme uses a single bus master and multiple slaves on the same wire. The bus master initiates
       all communication. The slaves can be individually discovered and addressed using their unique ID.

       Bus masters come in a variety of configurations including serial, parallel, i2c, network or USB adapters.

   OWFS design
       OWFS  is  a suite of programs that designed to make the 1-wire bus and its devices easily accessible. The
       underlying principle is to create a virtual filesystem, with the unique ID being the directory,  and  the
       individual properties of the device are represented as simple files that can be read and written.

       Details of the individual slave or master design are hidden behind a consistent interface. The goal is to
       provide an easy set of tools for a software designer to create monitoring or control applications.  There
       are  some  performance enhancements in the implementation, including data caching, parallel access to bus
       masters, and aggregation of device communication. Still the  fundamental  goal  has  been  ease  of  use,
       flexibility and correctness rather than speed.

   DS2438
       The  DS2438 (3) is a more complete form of the DS2436 battery chip. Current sensing is available, but not
       implemented. The major advantage compared to the DS2436 is that two voltages can be read, allowing one to
       correct circuit measurements for supply voltage and temperature. A better comparison is the DS276x family
       of chips.

ADDRESSING

       All 1-wire devices are factory assigned a unique 64-bit address. This address is of the form:

       Family Code
              8 bits

       Address
              48 bits

       CRC    8 bits

       Addressing under OWFS is in hexadecimal, of form:

              01.123456789ABC

       where 01 is an example 8-bit family code, and 12345678ABC is an example 48 bit address.

       The dot is optional, and the CRC code can included. If included, it must be correct.

DATASHEET

       http://pdfserv.maxim-ic.com/en/ds/DS2438.pdf
       http://pdfserv.maxim-ic.com/en/an/humsensor.pdf
       http://goo.gl/o9DH0 (Redirects to 009012_2.pdf PDF file on honeywell.com website)
       http://www.phanderson.com/hih-4000.pdf
       http://www.humirel.com/product/fichier/HTM1735%20RevG%20.pdf

SEE ALSO

   Programs
       owfs (1) owhttpd (1) owftpd (1) owserver (1) owdir (1) owread (1) owwrite (1) owpresent (1) owtap (1)

   Configuration and testing
       owfs (5) owtap (1) owmon (1)

   Language bindings
       owtcl (3) owperl (3) owcapi (3)

   Clocks
       DS1427 (3) DS1904 (3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415 (3) DS2417 (3)

   ID
       DS2401 (3) DS2411 (3) DS1990A (3)

   Memory
       DS1982 (3) DS1985 (3) DS1986 (3) DS1991 (3) DS1992 (3) DS1993 (3)  DS1995  (3)  DS1996  (3)  DS2430A  (3)
       DS2431 (3) DS2433 (3) DS2502 (3) DS2506 (3) DS28E04 (3) DS28EC20 (3)

   Switches
       DS2405 (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3) InfernoEmbedded (3)

   Temperature
       DS1822  (3)  DS1825  (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3) DS1921 (3) DS1821 (3) DS28EA00 (3)
       DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3) EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3)  MAX31826
       (3)

   Humidity
       DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)

   Voltage
       DS2450 (3)

   Resistance
       DS2890 (3)

   Multifunction (current, voltage, temperature)
       DS2436 (3) DS2437 (3) DS2438 (3) DS2751 (3) DS2755 (3) DS2756 (3) DS2760 (3) DS2770 (3) DS2780 (3) DS2781
       (3) DS2788 (3) DS2784 (3)

   Counter
       DS2423 (3)

   LCD Screen
       LCD (3) DS2408 (3)

   Crypto
       DS1977 (3)

   Pressure
       DS2406 (3) TAI8570 (3) EDS0066 (3) EDS0068 (3)

   Moisture
       EEEF (3) DS2438 (3)

AVAILABILITY