Provided by: libpcp3-dev_6.3.8-1_amd64 bug

NAME

       pmRegisterDerived, pmRegisterDerivedMetric  - register a global derived metric name and definition

C SYNOPSIS

       #include <pcp/pmapi.h>

       char *pmRegisterDerived(char *name, char *expr);
       int pmRegisterDerivedMetric(char *name, char *expr, char **errmsg);

       cc ... -lpcp

DESCRIPTION

       Derived  metrics  provide  a  way of extending the Performance Metrics Name Space (PMNS) with new metrics
       defined at the PCP client-side using expressions over the existing performance metrics.

       Typical uses would be to aggregate a number of similar metrics to provide a higher-level  summary  metric
       or to support the ``delta value-a over delta value-b'' class of metrics that are not possible in the base
       data semantics of PCP.  An example of the latter class would be the average I/O size, defined as
                                  delta(disk.dev.total_bytes) / delta(disk.dev.total)
       where  both of the disk.dev metrics are counters, and what is required is to sample both metrics, compute
       the difference between the current and previous values and then calculate the ratio of these differences.

       The arguments to pmRegisterDerived are the name of the new derived  metric  and  expr  is  an  expression
       defining how the values of name should be computed.

       pmRegisterDerivedMetric is the exact functional equivalent to pmRegisterDerived except that it provides a
       simplified model of error handling, where a formatted message is returned via the errmsg parameter.

       Syntactic  checking  is  performed  at  the  time  pmRegisterDerived  is called, but semantic checking is
       deferred  until  each  new  PMAPI  context  is  created  with  pmNewContext(3)  or  re-established   with
       pmReconnectContext(3),  at  which  time the PMNS and metadata is available to allow semantic checking and
       the metadata of the derived metrics to be determined.

       If pmRegisterDerived is called after one  or  more  PMAPI  contexts  has  been  opened,  then  the  newly
       registered  metrics will be available in those contexts, however the more normal use would be to make all
       calls to  pmRegisterDerived  (possibly  via  pmLoadDerivedConfig(3))  or  pmRegisterDerivedMetric  before
       calling pmNewContext(3).

       All of the defined global derived metrics are available in all PMAPI contexts.

       It  is  also  possible  to  define per-context derived metrics once a PMAPI context has been established.
       These derived metrics are private to the context in which they are  defined  using  the  allied  routines
       pmAddDerived(3) and pmAddDerivedMetric(3).

       name  should  follow  the  syntactic  rules  for  the  names  of  performance metrics, namely one or more
       components separated with a dot (``.''), and each component must begin with  an  alphabetic  followed  by
       zero  or  more characters drawn from the alphabetics, numerics and underscore (``_'').  For more details,
       refer to PCPIntro(1) and PMNS(5).

       name must be unique across all derived metrics and should not match the name of any regular metric in the
       PMNS.  It is acceptable for name to share some part of its prefix with an existing subtree of  the  PMNS,
       e.g.  the  average  I/O  size metric above could be named disk.dev.avgsz which would place it amongst the
       other disk.dev metrics in the PMNS.  Alternatively, derived metrics could populate their own  subtree  of
       the PMNS, e.g. the average I/O size metric above could be named my.summary.disk.avgsz.

       The expression expr follows these syntactic rules:

       • Terminal elements are either names of existing metrics or numeric constants.  Recursive definitions are
         not  allowed,  so  only  the  names of regular metrics (not other derived metrics) may be used. Numeric
         constants are either integers constrained to the  precision  of  32-bit  unsigned  integers  or  double
         precision floating point numbers.

       • The  usual  binary  arithmetic  operators  are supported, namely addition (``+''), subtraction (``-''),
         multiplication (``*'') and division (``/'') with the normal precedence rules where  multiplication  and
         division have higher precedence than addition and subtraction, so a+b*c is evaluated as a+(b*c).

       • Unary negation may be used, e.g.  -3*some.metric.

       • C-style  relational  operators  are  supported, namely ``<'', ``<='', ``=='', ``>='', ``>'' and ``!=''.
         Relational expressions return a value as a 32-bit unsigned number being 0 for false  and  1  for  true.
         The  expected  operator  precedence  rules  apply,  so arithmetic operators have higher precedence than
         relational operators, and a-b>c+d is evaluated as (a-b)>(c+d).  All the relational operators have equal
         precedence, so the (slightly odd) expression  involving  consecutive  relational  operators  a>b!=c  is
         evaluated as (a>b)!=c.

       • C-style  boolean  operators  are  supported,  namely and (``&&'') and or (``||'').  Boolean expressions
         return a value as a 32-bit unsigned number being 0 for false and 1 for  true.   The  expected  operator
         precedence  rules  apply,  so  relational  operators have higher precedence than boolean operators, and
         a>b*c&&d<=e+f is evaluated as (a>(b*c))&&(d<=(e+f)).  Both the boolean operators have equal precedence,
         so the  expression  involving  consecutive  boolean  operators  a>=b||b>c&&d!=e||f>g  is  evaluated  as
         (((a>=b)||(b>c))&&(d!=e))||(f>g).

       • Additionally,  the ``!'' operator may be used to negate a boolean or relational expression, returning a
         value as a 32-bit unsigned number being 0 for false and 1 for true.  The expected  operator  precedence
         rules  apply,  so  boolean (and relational) operators have higher precedence than boolean negation, and
         !a>b||c<d is evaluated as !((a>b)||(c<d)), while !a<b+c is evaluated as !(a<(b+c)).

       • C-style ternary conditional expressions are supported. In general terms the expression check  ?  foo  :
         bar  is  evaluated  as foo (the ``true'' operand) if check (the ``guard'') is true, else the expression
         evaluates to bar (the  ``false''  operand).   Some  special  semantic  rules  apply  to  the  ``guard''
         expression and the other two operand expressions:
         (a) Each  expression  may involve a singular value or a set of values (when the expression involves one
             or more metrics with an instance domain).
         (b) All expressions with a set of values must be defined over the same instance domain.
         (c) Both operand expressions must have the same metadata, so the same metric type, semantics and  units
             (dimension and scale).
         (d) The  ``guard'' expression must have an arithmetic or relational or boolean value, so that it can be
             evaluated as 0 for false, else true.
         (e) If the ``guard'' expression has a singular value and one or more of the other  operand  expressions
             involves an instance domain, the ``guard'' applies to all instances.
         (f) If  the  ``guard''  expression has a set of values and one or more of the other operand expressions
             involves an instance domain, the ``guard'' is evaluated once for each instance (there must  be  one
             instance domain as per rule (b) above).
         (g) If  one  of the operand expressions has a singular value and the other has a set of values, and the
             singular value is selected based on the evaluation of the ``guard'', then the result is  a  set  of
             values  (all the same) with instance enumeration being taken from the other operand expression. For
             example in the expression: check ? foo : bar, if foo is an expression with a singular value and bar
             is a set-valued expression, then if check is true, then the result is a set of values  (all  having
             the same value, foo) over the instance domain of bar.
         (h) As  a  special  case,  either  (but  not  both)  of  the  expressions foo or bar may be the special
             constructor novalue().  If novalue() needs to be evaluated, it will return  no  values.   The  most
             common use of novalue() is in conjunction with defined() as in the following example:
                 mumble = defined(abc.def) ? count(abc.def) : novalue()
             The  metadata for novalue() is taken from the peer operand of the : operator, making conditions (b)
             and (c) above trivially true; if the peer operand cannot be evaluated, then  the  default  metadata
             for novalue() is a singular discrete integer with no units, and conditions (b) and (c) are waived.
             An extension of novalue() is novalue(<metadata>) where the <metadata> can be specified using one or
             more  parameters  of  the  form tag=value or tag="value" as described for the mkconst() constructor
             below, for example:
                 novalue(type=float, semantics=instant, units="Kbytes/sec")
         (i) As an additional further case, if check is of  the  form  defined(somemetric)  then  references  to
             undefined  metrics  are  allowed  in  whichever of foo or bar is not required once the existence if
             somemetric has been established.  This allows uses of the form:
                 fumble = defined(new.metric) ? new.metric : old.metric
             which is valid when new.metric is defined and when new.metric is not defined,  although  this  does
             mean  rules  (b)  and  (c) are relaxed in this case, which further means novalue() may have no peer
             operand to provide metadata.
             A generalization of this construct is supported for any check that can be evaluated statically,  so
             a boolean expression involving defined() predicates, for example:
                 bar = !defined(a) || !defined(b) ? novalue() : a + b

       • Selection  of  a  single  instance  can  be specified by the construct ``[instance_name]'' which may be
         appended to a metric name or a parenthesized expression.  For example:
             fw.bytes = network.interface.in.bytes[eth1] + \
                        network.interface.out.bytes[eth1]
         or (equivalently):
             fw.bytes = (network.interface.in.bytes + \
                         network.interface.out.bytes)[eth1]

         All characters between the ``['' and ``]'' are considered to be part of the (external)  instance  name,
         so  be  careful  to avoid any spurious white space.  A backslash may be used as an escape prefix in the
         (unlikely) event that the external instance name contains a ``]''.

       • Numeric constants can also be specified using  the  mkconst()  constructor  which  takes  a  number  of
         arguments:  the first is a numeric constant (either integer or floating point), then follow one or more
         parameters of the form tag=value or tag="value" where the allowed  values  of  tag  and  value  are  as
         follows:
         ┌───────────┬─────────────────────────────────────────────────────────────────────────────────────────┐
         │    tagvalue                                          │
         ├───────────┼─────────────────────────────────────────────────────────────────────────────────────────┤
         │ type      │ one of the numeric metric types from <pcp/pmapi.h>, stripped of the PM_TYPE_ prefix, so │
         │           │ 32, U32, 64, U64, FLOAT or DOUBLE.                                                      │
         ├───────────┼─────────────────────────────────────────────────────────────────────────────────────────┤
         │ semantics │ one  of  the  semantic  types  from  <pcp/pmapi.h>,  stripped of the PM_SEM_ prefix, so │
         │           │ COUNTER, INSTANT or DISCRETE.                                                           │
         ├───────────┼─────────────────────────────────────────────────────────────────────────────────────────┤
         │ units     │ a specification of dimension and scale (together forming  the  units),  in  the  syntax │
         │           │ accepted by pmParseUnitsStr(3).                                                         │
         ├───────────┼─────────────────────────────────────────────────────────────────────────────────────────┤
         │ meta      │ a  metric name and that metric provides the base metadata that may be modified by other │
         │           │ parameters                                                                              │
         └───────────┴─────────────────────────────────────────────────────────────────────────────────────────┘

         The value may optionally be enclosed in double quotes, and may appear in any mix of upper and/or  lower
         case.  The tag must be in lower case as shown in the table above.

         This  is  most useful when the expression semantics require matching type and/or semantics and/or units
         for operands, e.g.
             idle = mem.util.free > mkconst(10485760, units=Kbyte)
             avg_io_size = delta(disk.dev.total) == 0 ? \
                 mkconst(1.0, semantics=instant, units="kbyte / count") : \
                 delta(disk.dev.total_bytes) / delta(disk.dev.total)

       • Expressions may be rescaled using the rescale function that takes  two  arguments.   The  first  is  an
         arithmetic  expression  to  be  rescaled, and the second is the desired units after rescaling that is a
         string value in the syntax accepted by pmParseUnitsStr(3).  For example:
             rescale(network.interface.total.bytes, "Mbytes/hour")

         The expression and the desired units must both have  the  same  dimension,  e.g  Space=1,  Time=-1  and
         Count=0 in the example above.

       • The  following  unary  functions  operate on a single performance metric and return one or more values.
         For all functions (except count() and defined()), the type of the operand  metric  must  be  arithmetic
         (integer of various sizes and signedness, float or double).
         ┌────────────┬────────────────────────────────────────────────────────────────────────────────────────┐
         │  Function  │                                         Value                                          │
         ├────────────┼────────────────────────────────────────────────────────────────────────────────────────┤
         │ avg(x)     │ A singular instance being the average value across all instances for the metric x.     │
         ├────────────┼────────────────────────────────────────────────────────────────────────────────────────┤
         │ count(x)   │ A singular instance being the count of the number of instances for the metric x.  As a │
         │            │ special case, if fetching the metric x returns an error, then count(x) will be 0.      │
         ├────────────┼────────────────────────────────────────────────────────────────────────────────────────┤
         │ defined(x) │ A  boolean  value  that  is  true (``1'') if the metric x is defined in the PMNS, else │
         │            │ false (``0'').  The function is evaluated when a new PMAPI  context  is  created  with │
         │            │ pmNewContext(3)  or  re-established  with  pmReconnectContext(3).   So  any subsequent │
         │            │ changes to the PMNS after the PMAPI context has been established will not  change  the │
         │            │ value of this function in the expression evaluation.                                   │
         ├────────────┼────────────────────────────────────────────────────────────────────────────────────────┤
         │ max(x)     │ A singular instance being the maximum value across all instances for the metric x.     │
         ├────────────┼────────────────────────────────────────────────────────────────────────────────────────┤
         │ min(x)     │ A singular instance being the minimum value across all instances for the metric x.     │
         ├────────────┼────────────────────────────────────────────────────────────────────────────────────────┤
         │ sum(x)     │ A singular instance being the sum of the values across all instances for the metric x. │
         └────────────┴────────────────────────────────────────────────────────────────────────────────────────┘

       • The  following  unary function returns the instantaneous value of an expression, not the rate-converted
         value that is the default for expressions with the semantics of PM_SEM_COUNTER.
         ┌───────────────┬─────────────────────────────────────────────────────────────────────────────────────┐
         │   Function    │                                        Value                                        │
         ├───────────────┼─────────────────────────────────────────────────────────────────────────────────────┤
         │ instant(expr) │ Returns the current value of the  expression,  even  it  has  the  semantics  of  a │
         │               │ counter, i.e. PM_SEM_COUNTER.  The semantics of the derived metric are based on the │
         │               │ semantics  of  the  expression  expr;  if  expr  has  semantics PM_SEM_COUNTER, the │
         │               │ semantics of instant(expr)  is  PM_SEM_INSTANT,  otherwise  the  semantics  of  the │
         │               │ derived metric is the same as the semantics of expr.                                │
         └───────────────┴─────────────────────────────────────────────────────────────────────────────────────┘

       • The  following  unary  functions  return values computed from the value of an expression on consecutive
         samples, or pmFetch(3) calls.  The expression (expr below) may involve one or  more  metrics  but  must
         have an arithmetic value (integer of various sizes and signedness, float or double) for all instances.

         If expr is a set-valued expression then only those instances that appear in both samples will appear in
         the result.
         ┌─────────────┬───────────────────────────────────────────────────────────────────────────────────────┐
         │  Function   │                                         Value                                         │
         ├─────────────┼───────────────────────────────────────────────────────────────────────────────────────┤
         │ delta(expr) │ Returns  the  difference  in values for the expression between one call to pmFetch(3) │
         │             │ and the next. There is one value in the result for each instance that appears in both │
         │             │ the current and the previous sample.  If the expression is unsigned, then the type of │
         │             │ the result is converted to ensure as much precision as possible can be  retained,  so │
         │             │ if the expression has type PM_TYPE_U32 then the result is of type PM_TYPE_64, else if │
         │             │ the  expression  has  type  PM_TYPE_U64  then  the  result is of type PM_TYPE_DOUBLE. │
         │             │ Otherwise the type of the result is the same as the type of the expression.           │
         ├─────────────┼───────────────────────────────────────────────────────────────────────────────────────┤
         │ rate(expr)  │ Returns the difference in values for the expression between one  call  to  pmFetch(3) │
         │             │ and  the  next  divided  by  the  elapsed  time between the calls to pmFetch(3).  The │
         │             │ semantics of the derived metric are based on the semantics of the expression with the │
         │             │ dimension in the time domain decreased by one and scaling if  required  in  the  time │
         │             │ utilization  case  where  the  operand is in units of time, and the derived metric is │
         │             │ unitless.  There is one value in the result for each instance that  appears  in  both │
         │             │ the  current and the previous sample, except in the case where the expression has the │
         │             │ semantics of a counter, i.e. PM_SEM_COUNTER, and current  value  of  an  instance  is │
         │             │ smaller  than  the  previous value of the same instance then no value is returned for │
         │             │ this instance (this corresponds to a ``counter wrap'' or a ``counter reset'').  These │
         │             │ rules mimic the rate conversion applied to counter metrics by tools such as pmval(1), │
         │             │ pmie(1) and pmchart(1).                                                               │
         └─────────────┴───────────────────────────────────────────────────────────────────────────────────────┘

       • The matchinst function may be used to select a subset of the instances from an instance  domain  for  a
         metric or expression.  The function takes two arguments:
         (a) A  instance  filter  that  consists  of  an  optional negation operator ``!'' followed by a regular
             expression delimited by ``/'' characters.   The  regular  expression  follows  the  POSIX  Extended
             Regular  Expression  syntax as described in regex(3).  A single backslash may be used to escape the
             regular expression delimiter ``/'', but double backslashes  are  required  to  escape  any  regular
             expression  special characters, e.g. for the (extremely unlikely) case of wanting to match instance
             names like ``some*text/other[text]'' a regular expression of the form  /some\\*text\/other\\[text]/
             would  be  required.  If present, the negation operator reverses the sense of the filtering, so all
             instances not matching the regular expression will be selected.
         (b) A metric or expression that must be defined over an instance domain.

         For example, the following expression will have values for the  metric  network.interface.in.bytes  for
         all network interfaces except the loopback and virtual bridge devices:
             matchinst(!/^(lo)|(vbir)/, network.interface.in.bytes)

       • The  scalar  function may be used convert a metric or expression defined over an instance domain into a
         scalar value that can be used in other expressions.  For example:
             net.in.bytes = scalar(network.interface.in.bytes[eth0]) + \
                        scalar(network.interface.in.bytes[eth1])

         The instance domain is removed from the metadata for the result and the instance identifier is  removed
         from the value during fetching.

         If  the  metric  or expression involves more than one instance then the result is formed by picking the
         first instance - this is arbitrary and implies the scalar function should only be used for  metrics  or
         expressions that are expected to contain zero or one instances, e.g.  the construct ``[instance_name]''
         or the matchinst function with a pattern that matches at most one instance.

       • Parenthesis may be used for explicit grouping.

       • A  line  ending  with  ``\'' is treated as ``to be continued'' and the following line is appended after
         stripping the ``\'' and the embedded newline.

       • Lines beginning with ``#'' are treated as comments and ignored.

       • White space is ignored.

SEMANTIC CHECKS AND RULES

       There are a number of conversions required to determine the metadata for a derived metric and  to  ensure
       the semantics of the expressions are sound.

       In  an  arithmetic  expression  or  a  relational  expression, if the semantics of both operands is not a
       counter (i.e. PM_SEM_INSTANT or PM_SEM_DISCRETE) then  the  result  will  have  semantics  PM_SEM_INSTANT
       unless both operands are PM_SEM_DISCRETE in which case the result is also PM_SEM_DISCRETE.

       For  an  arithmetic  expression,  the  dimension  of  each  operand  must  be the same.  For a relational
       expression, the dimension of each operand must be the  same,  except  that  numeric  constants  (with  no
       dimension) are allowed, e.g. in the expression network.interface.in.drops > 0 .

       To  prevent  arbitrary  and non-sensical combinations some restrictions apply to expressions that combine
       metrics with counter semantics to produce a result with counter semantics.  For an arithmetic expression,
       if both operands have the semantics of a counter, then only addition or subtraction is allowed, or if the
       left operand is a counter and the right operand is not, then only multiplication or division are allowed,
       or if the left operand is not a counter and the right operand is a counter, then only  multiplication  is
       allowed.

       Because  relational  expressions  use  the current value only and produce a result that is not a counter,
       either or both operands of a relational expression may be counters.

       The mapping of the pmUnits of the metadata uses the following rules:

       • If both operands have a dimension of Count and the scales are not the same, use the  larger  scale  and
         convert the values of the operand with the smaller scale.

       • If  both  operands  have  a dimension of Time and the scales are not the same, use the larger scale and
         convert the values of the operand with the smaller scale.

       • If both operands have a dimension of Space and the scales are not the same, use the  larger  scale  and
         convert the values of the operand with the smaller scale.

       • For addition and subtraction all dimensions for each of the operands and result are identical.

       • For multiplication, the dimensions of the result are the sum of the dimensions of the operands.

       • For division, the dimensions of the result are the difference of the dimensions of the operands.

       Scale  conversion  involves division if the dimension is positive else multiplication if the dimension is
       negative. If scale conversion is applied to either of the  operands,  the  result  is  promoted  to  type
       PM_TYPE_DOUBLE.

       Putting all of this together in an example, consider the derived metric defined as follows:
             x = network.interface.speed - delta(network.interface.in.bytes) / delta(sample.milliseconds)
       The type, dimension and scale settings would propagate up the expression tree as follows.
                    ┌─────────────────────────┬────────┬───────────────────┬────────────────────┐
                    │       Expression        │  Type  │ Dimension & Scale │  Scale Factor(s)   │
                    ├─────────────────────────┼────────┼───────────────────┼────────────────────┤
                    │ sample.milliseconds     │ DOUBLE │ millisec          │                    │
                    │ delta(...)              │ DOUBLE │ millisec          │                    │
                    │ network...bytes         │ U64    │ byte              │                    │
                    │ delta(...)              │ U64    │ byte              │                    │
                    │ delta(...) / delta(...) │ DOUBLE │ byte/millisec     │ /1048576 and *1000 │
                    │ network...speed         │ FLOAT  │ Mbyte/sec         │                    │
                    │ x                       │ DOUBLE │ Mbyte/sec         │                    │
                    └─────────────────────────┴────────┴───────────────────┴────────────────────┘

       Expressions involving single instance selection or the matchinst function must be associated with
       underlying metrics that have an instance domain.  These constructors make no sense for singular metrics.

       Because semantic checking cannot be done at the time pmRegisterDerived is called, errors found during
       semantic checking (when any subsequent calls to pmNewContext(3) or pmReconnectContext(3) succeed) are
       reported using pmprintf(3).  These include:

       Error: derived metric <name1>: operand: <name2>: <reason>
              There  was  a  problem  calling pmLookupName(3) to identify the operand metric <name2> used in the
              definition of the derived metric <name1>.

       Error: derived metric <name1>: operand (<name2> [<pmid2>]): <reason>
              There was a problem calling pmLookupDesc(3) to identify  the  operand  metric  <name2>  with  PMID
              <pmid2> used in the definition of the derived metric <name1>.

       Semantic error: derived metric <name>: <operand> : <operand> Different <metadata> for ternary operands
              For  a  ternary  expression,  the ``true'' operand and the ``false'' operand must have exactly the
              same metadata, so type, semantics, instance domain, and units (dimension and scale).

       Semantic error: derived metric <name>: <operand> <op> <operand>: Dimensions are not the same
              Operands must have the same units (dimension and scale) for each  of  addition,  subtraction,  the
              relational operators and the boolean ``and'' or ``or'' operators.

       Semantic error: derived metric <name>: <operand> <op> <operand>: Illegal operator for counter and non-
       counter
              Only multiplication or division are allowed if the left operand has the semantics of a counter and
              the right operand is not a counter.

       Semantic error: derived metric <name>: <operand> <op> <operand>: Illegal operator for counters
              If  both  operands  have  the  semantics  of  counter, only addition or subtraction make sense, so
              multiplication and division are not allowed.

       Semantic error: derived metric <name>: <operand> <op> <operand>: Illegal operator for non-counter and
       counter
              Only multiplication is allowed if the right operand has the semantics of a counter  and  the  left
              operand is not a counter.

       Semantic error: derived metric <metric> <expr> RESCALE <units>: Incompatible dimensions
              The  parameters  <expr> and <units> to the rescale function must have the same dimension along the
              axes of Time, Space and Count.

       Semantic error: derived metric <name>: Incorrect time dimension for operand
              Rate conversion using the rate() function is  only  possible  for  operand  metrics  with  a  Time
              dimension  of 0 or 1 (see pmLookupDesc(3)).  If the operand metric's Time dimension is 0, then the
              derived metrics has a value "per second" (Time dimension of -1).  If  the  operand  metric's  Time
              dimension is 1, then the derived metrics has a value of time utilization (Time dimension of 0).

       Semantic error: derived metric <name>: <function>(<operand>): Non-arithmetic operand for function
              The  unary  functions  are  only  defined if the operand has arithmetic type.  Similarly the first
              argument to the rescale function must be of arithmetic type.

       Semantic error: derived metric <name>: <expr> ? ...: Non-arithmetic operand for ternary guard
              The first expression for a ternary operator must have an arithmetic type.

       Semantic error: derived metric <name>: ... - ...: Non-arithmetic operand for unary negation
              Unary negation only makes sense if the following expression has an arithmetic type.

       Semantic error: derived metric <name>: <operand> <op> <operand>: Non-arithmetic type for <left-or-right>
       operand
              The binary arithmetic operators are only allowed with operands with an arithmetic type (integer of
              various sizes and signedness, float or double).

       Semantic error: derived metric <name>: <operand> <op> <operand>: Non-counter and not dimensionless for
       <left-or-right> operand
              For multiplication or division or any of the relational operators, if one of the operands has  the
              semantics  of  a  counter  and  the  other  has  the  semantics of a non-counter (instantaneous or
              discrete) then the non-counter operand must have no units (dimension and scale).

       Semantic error: derived metric <name>: <expr> ? <expr> : <expr>: Non-scalar ternary guard with scalar
       expressions
              If the ``true'' and ``false'' operands of a ternary expression  have  a  scalar  value,  then  the
              ``guard'' expression must also have a scalar value.

       Semantic error: derived metric <name>: <expr> <op> <expr>: Operands should have the same instance domain
              For  all  of  the  binary  operators (arithmetic and relational), if both operands have non-scalar
              values, then they must be defined over the same instance domain.

       Semantic error: derived metric <name>: operand <dname>: Illegal nested derived metric
              A derived metric (<dname>) cannot be nested (i.e. used)  in  the  definition  of  another  derived
              metric (<name>).

       Semantic error: derived metric <name>: <expr> <op> <expr>: Illegal operator for non-counters
              Metrics  with  counter semantics may be added or subtracted, but <op> (division or multiplication)
              is not allowed.

       Semantic error: derived metric <name>: operand <bname>: Unknown metric for ternary expression
              When a new context was established, the metric <bname> was not in the PMNS of the new context  and
              <bname> is a required operand in the definition of the derived metric <name>.

EXPRESSION EVALUATION

       For the binary arithmetic operators, if either operand must be scaled (e.g. convert bytes to Kbytes) then
       the result is promoted to PM_TYPE_DOUBLE.  Otherwise the type of the result is determined by the types of
       the operands, as per the following table which is evaluated from top to bottom until a match is found.
                             ┌──────────────────────────────┬──────────┬────────────────┐
                             │        Operand Types         │ Operator │  Result Type   │
                             ├──────────────────────────────┼──────────┼────────────────┤
                             │ either is PM_TYPE_DOUBLE     │ any      │ PM_TYPE_DOUBLE │
                             ├──────────────────────────────┼──────────┼────────────────┤
                             │ any                          │ division │ PM_TYPE_DOUBLE │
                             ├──────────────────────────────┼──────────┼────────────────┤
                             │ either is PM_TYPE_FLOAT      │ any      │ PM_TYPE_FLOAT  │
                             ├──────────────────────────────┼──────────┼────────────────┤
                             │ either is PM_TYPE_U64        │ any      │ PM_TYPE_U64    │
                             ├──────────────────────────────┼──────────┼────────────────┤
                             │ either is PM_TYPE_64         │ any      │ PM_TYPE_64     │
                             ├──────────────────────────────┼──────────┼────────────────┤
                             │ either is PM_TYPE_U32        │ any      │ PM_TYPE_U32    │
                             ├──────────────────────────────┼──────────┼────────────────┤
                             │ otherwise      (both     are │ any      │ PM_TYPE_32     │
                             │ PM_TYPE_32)                  │          │                │
                             └──────────────────────────────┴──────────┴────────────────┘

PMIDs AND MASKING

       Within PCP each metric is assigned a unique Performance Metric Identifier (PMID) and internally a PMID is
       constructed from 3 fields: the domain number (of the associated  Performance  Metrics  Domain  Agent,  or
       PMDA),  the  cluster  number and the item number.  Derived metrics use the reserved domain number 511 and
       special PMIDs as described in the following table, where the PMID is shown as domain.cluster.item:
       ┌────────────────┬───────────────┬──────────────────────────────────────────────────────────────────────┐
       │ Derived Metric │ Starting PMID │                             Description                              │
       ├────────────────┼───────────────┼──────────────────────────────────────────────────────────────────────┤
       │ global         │ 511.0.1       │ Metrics are assigned ascending PMIDs as they are registered via      │
       │                │               │ pmRegisterDerived, pmRegisterDerivedMetric or                        │
       │                │               │ pmLoadDerivedConfig(3).                                              │
       ├────────────────┼───────────────┼──────────────────────────────────────────────────────────────────────┤
       │ per-context    │ 511.2047.1023 │ Metrics are assigned descending PMIDs as they are registered via     │
       │                │               │ pmAddDerived(3) or pmAddDerivedMetric(3).                            │
       ├────────────────┼───────────────┼──────────────────────────────────────────────────────────────────────┤
       │ remapped       │ 511.c.i       │ When a derived metric is recorded in a PCP archive by pmlogger(1) or │
       │                │               │ one of the related archive creation tools, the PMID of the derived   │
       │                │               │ metric is remapped in the archive so that c is the cluster of        │
       │                │               │ derived metric plus 2048, and i is the item of the derived metric.   │
       │                │               │ For example, a derived metric with PMID 511.0.13 will have the       │
       │                │               │ remapped PMID 511.2048.13 in an archive.  See pmlogger(1) for a      │
       │                │               │ discussion about adding derived metrics to a PCP archive.            │
       └────────────────┴───────────────┴──────────────────────────────────────────────────────────────────────┘

       For base metrics from a host or archive context, there is a requirement that each metric name is  unique.
       But derived metrics require this restriction to be relaxed, so that the same metric name could associated
       with  a base metric, and/or a per-context derived metric, and/or a global metric.  This means that one or
       more of the metrics with the same name may be masked by other metrics of the same  name.   The  following
       table  describes  which  metric will be used when one of these multiply-defined names is presented to the
       PMAPI.
       ┌─────────────┬─────────────────────────────────┬───────────────────────────────────────────────────────┐
       │             │         derived metric          │                                                       │
       │ base metric ├──────────┬─────────────┬────────┤                     chosen metric                     │
       │             │ remapped │ per-context │ global │                                                       │
       ├─────────────┼──────────┼─────────────┼────────┼───────────────────────────────────────────────────────┤
       │ no          │ no       │ no          │ no     │ none; the metric is undefined                         │
       ├─────────────┼──────────┼─────────────┼────────┼───────────────────────────────────────────────────────┤
       │ no          │ no       │ no          │ yes    │ global derived                                        │
       ├─────────────┼──────────┼─────────────┼────────┼───────────────────────────────────────────────────────┤
       │ no          │ no       │ yes         │ no     │ per-context derived                                   │
       ├─────────────┼──────────┼─────────────┼────────┼───────────────────────────────────────────────────────┤
       │ no          │ no       │ yes         │ yes    │ per-context derived                                   │
       ├─────────────┼──────────┼─────────────┼────────┼───────────────────────────────────────────────────────┤
       │ no          │ yes      │ no          │ no     │ remapped                                              │
       ├─────────────┼──────────┼─────────────┼────────┼───────────────────────────────────────────────────────┤
       │ no          │ yes      │ no          │ yes    │ remapped                                              │
       ├─────────────┼──────────┼─────────────┼────────┼───────────────────────────────────────────────────────┤
       │ no          │ yes      │ yes         │ no     │ remapped                                              │
       ├─────────────┼──────────┼─────────────┼────────┼───────────────────────────────────────────────────────┤
       │ no          │ yes      │ yes         │ yes    │ remapped                                              │
       ├─────────────┼──────────┼─────────────┼────────┼───────────────────────────────────────────────────────┤
       │ yes         │ no       │ no          │ no     │ base metric                                           │
       ├─────────────┼──────────┼─────────────┼────────┼───────────────────────────────────────────────────────┤
       │ yes         │ no       │ no          │ yes    │ base metric                                           │
       ├─────────────┼──────────┼─────────────┼────────┼───────────────────────────────────────────────────────┤
       │ yes         │ no       │ yes         │ no     │ base metric                                           │
       ├─────────────┼──────────┼─────────────┼────────┼───────────────────────────────────────────────────────┤
       │ yes         │ no       │ yes         │ yes    │ base metric                                           │
       ├─────────────┼──────────┼─────────────┼────────┼───────────────────────────────────────────────────────┤
       │ yes         │ yes      │ -           │ -      │ cannot happen; for any name there can be at most one  │
       │             │          │             │        │ of a base metric or a remapped metric                 │
       └─────────────┴──────────┴─────────────┴────────┴───────────────────────────────────────────────────────┘

       When masking happens, it is done silently.  Most PCP applications support -Dderive on  the  command  line
       and this pmdbg(1) debug option will report derived metric operations (including masking) on stderr.

CAVEATS

       Derived metrics are not available when using pmFetchArchive(3) as this routine does not use a target list
       of PMIDs that could be remapped (as is done for pmFetch(3)).

       There  is no pmUnregisterDerived method, so once registered a derived metric persists for the life of the
       application.

DIAGNOSTICS

       On success, pmRegisterDerived returns NULL.

       If a syntactic error is found at the time of registration, the value returned by pmRegisterDerived  is  a
       pointer  into expr indicating where the error was found.  To identify what the error was, the application
       should call pmDerivedErrStr(3) to retrieve the corresponding parser error message.

       pmRegisterDerivedMetric returns 0 and errmsg is undefined if the parsing is successful.

       If the given expr does not conform to the  required  syntax  pmRegisterDerivedMetric  returns  -1  and  a
       dynamically allocated error message string in errmsg.  The error message is terminated with a newline and
       includes  both  the  input  name and expr, along with an indicator of the position at which the error was
       detected.  e.g.
                 Error: pmRegisterDerivedMetric("my.disk.rates", ...) syntax error
                 4rat(disk.dev.read)
                     ^

       The position indicator line may be followed by an additional diagnostic line describing the nature of the
       error, when available.

       In the case of an error, the pmRegisterDerivedMetric caller is responsible for calling free(3) to release
       the space allocated for errmsg.

SEE ALSO

       PCPIntro(1), pmlogger(1), PMAPI(3), free(3), pmAddDerived(3), pmAddDerivedMetric(3),  pmDerivedErrStr(3),
       pmFetch(3), pmLoadDerivedConfig(3), pmNewContext(3), pmReconnectContext(3), pmprintf(3) and PMNS(5).

Performance Co-Pilot                                                                        PMREGISTERDERIVED(3)