The following configuration parameters are defined for the Kernel
application. See app(3erl) for more information about configuration
parameters.
- browser_cmd
= string() | {M,F,A}:
- When pressing the Help button in a tool such as Debugger or TV, the help
text (an HTML file File) is by default displayed in a Netscape
browser which is required to be up and running. This parameter can be used
to change the command for how to display the help text if another browser
than Netscape is preferred, or another platform than Unix or Windows is
used.
If set to a string Command, the command "Command
File" will be evaluated using os:cmd/1.
If set to a module-function-args tuple {M,F,A}, the call
apply(M,F,[File|A]) will be evaluated.
- distributed
= [Distrib]:
- Specifies which applications are distributed and on which nodes they may
execute. In this parameter:
- *
- Distrib = {App,Nodes} | {App,Time,Nodes}
- *
- App = atom()
- *
- Time = integer()>0
- *
- Nodes = [node() | {node(),...,node()}]
- dist_auto_connect
= Value:
- Specifies when nodes will be automatically connected. If this parameter is
not specified, a node is always automatically connected, e.g when a
message is to be sent to that node. Value is one of:
- never:
- Connections are never automatically established, they must be explicitly
connected. See net_kernel(3erl).
- once:
- Connections will be established automatically, but only once per node. If
a node goes down, it must thereafter be explicitly connected. See
net_kernel(3erl).
- permissions
= [Perm]:
- Specifies the default permission for applications when they are started.
In this parameter:
- *
- Perm = {ApplName,Bool}
- *
- ApplName = atom()
- *
- Bool = boolean()
- error_logger
= Value:
- Value is one of:
- tty:
- Installs the standard event handler which prints error reports to
stdio. This is the default option.
- {file, FileName}:
- Installs the standard event handler which prints error reports to the file
FileName, where FileName is a string.
- false:
- No standard event handler is installed, but the initial, primitive event
handler is kept, printing raw event messages to tty.
- silent:
- Error logging is turned off.
- global_groups
= [GroupTuple]:
- Defines global groups, see global_group(3erl).
- *
- GroupTuple = {GroupName, [Node]} | {GroupName, PublishType,
[Node]}
- *
- GroupName = atom()
- *
- PublishType = normal | hidden
- *
- Node = node()
- inet_default_connect_options
= [{Opt, Val}]:
- Specifies default options for connect sockets, see
inet(3erl).
- inet_default_listen_options
= [{Opt, Val}]:
- Specifies default options for listen (and accept) sockets,
see inet(3erl).
- {inet_dist_use_interface, ip_address()}:
- If the host of an Erlang node has several network interfaces, this
parameter specifies which one to listen on. See inet(3erl) for the
type definition of ip_address().
- {inet_dist_listen_min, First}:
- See below.
- {inet_dist_listen_max, Last}:
- Define the First..Last port range for the listener socket of a
distributed Erlang node.
- inet_parse_error_log
= silent:
- If this configuration parameter is set, no error_logger messages
are generated when erroneous lines are found and skipped in the various
Inet configuration files.
- inetrc =
Filename:
- The name (string) of an Inet user configuration file. See ERTS User's
Guide, Inet configuration.
- net_setuptime
= SetupTime:
-
SetupTime must be a positive integer or floating point
number, and will be interpreted as the maximally allowed time for each
network operation during connection setup to another Erlang node. The
maximum allowed value is 120; if higher values are given, 120 will be used.
The default value if the variable is not given, or if the value is incorrect
(e.g. not a number), is 7 seconds.
Note that this value does not limit the total connection setup
time, but rather each individual network operation during the connection
setup and handshake.
- net_ticktime
= TickTime:
-
Specifies the net_kernel tick time. TickTime is
given in seconds. Once every TickTime/4 second, all connected nodes
are ticked (if anything else has been written to a node) and if nothing has
been received from another node within the last four (4) tick times that
node is considered to be down. This ensures that nodes which are not
responding, for reasons such as hardware errors, are considered to be
down.
The time T, in which a node that is not responding is
detected, is calculated as: MinT < T < MaxT where:
MinT = TickTime - TickTime / 4
MaxT = TickTime + TickTime / 4
TickTime is by default 60 (seconds). Thus, 45 < T
< 75 seconds.
Note: All communicating nodes should have the same
TickTime value specified.
Note: Normally, a terminating node is detected
immediately.
- shutdown_timeout
= integer() | infinity:
- Specifies the time application_controller will wait for an
application to terminate during node shutdown. If the timer expires,
application_controller will brutally kill application_master
of the hanging application. If this parameter is undefined, it defaults to
infinity.
- sync_nodes_mandatory
= [NodeName]:
- Specifies which other nodes must be alive in order for this node to
start properly. If some node in the list does not start within the
specified time, this node will not start either. If this parameter is
undefined, it defaults to [].
- sync_nodes_optional
= [NodeName]:
- Specifies which other nodes can be alive in order for this node to
start properly. If some node in this list does not start within the
specified time, this node starts anyway. If this parameter is undefined,
it defaults to the empty list.
- sync_nodes_timeout
= integer() | infinity:
- Specifies the amount of time (in milliseconds) this node will wait for the
mandatory and optional nodes to start. If this parameter is undefined, no
node synchronization is performed. This option also makes sure that
global is synchronized.
- start_dist_ac
= true | false:
- Starts the dist_ac server if the parameter is true. This
parameter should be set to true for systems that use distributed
applications.
The default value is false. If this parameter is undefined,
the server is started if the parameter distributed is set.
- start_boot_server
= true | false:
- Starts the boot_server if the parameter is true (see
erl_boot_server(3erl)). This parameter should be set to true
in an embedded system which uses this service.
The default value is false.
- boot_server_slaves
= [SlaveIP]:
- If the start_boot_server configuration parameter is true,
this parameter can be used to initialize boot_server with a list of
slave IP addresses. SlaveIP = string() | atom |
{integer(),integer(),integer(),integer()}
where 0 <= integer() <=255.
Examples of SlaveIP in atom, string and tuple form are:
'150.236.16.70', "150,236,16,70", {150,236,16,70}.
- start_disk_log
= true | false:
- Starts the disk_log_server if the parameter is true (see
disk_log(3erl)). This parameter should be set to true in an
embedded system which uses this service.
The default value is false.
- start_pg2 =
true | false:
- Starts the pg2 server (see pg2(3erl)) if the parameter is
true. This parameter should be set to true in an embedded
system which uses this service.
The default value is false.
- start_timer
= true | false:
- Starts the timer_server if the parameter is true (see
timer(3erl)). This parameter should be set to true in an
embedded system which uses this service.
The default value is false.
- shutdown_func
= {Mod, Func}:
- Where:
- *
- Mod = atom()
- *
- Func = atom()
Sets a function that application_controller calls when it
starts to terminate. The function is called as: Mod:Func(Reason),
where Reason is the terminate reason for
application_controller, and it must return as soon as possible for
application_controller to terminate properly.