xenial (1) fdrawcmd.1.gz

Provided by: fdutils_5.5-20060227-7_amd64 bug

Name

       fdrawcmd - send raw commands to the floppy disk controller

Note

       This  manpage  has  been  automatically  generated  from  fdutils's texinfo documentation.  However, this
       process is only approximative, and some items, such as cross-references, footnotes and indices  are  lost
       in  this  translation  process.   Indeed,  these  items have no appropriate representation in the manpage
       format.  Moreover, only the items specific  to  each  command  have  been  translated,  and  the  general
       information about fdutils has been dropped in the manpage version.  Thus I strongly advise you to use the
       original texinfo doc.

       *      To generate a printable copy from the texinfo doc, run the following commands:

                     ./configure; make dvi; dvips fdutils.dvi

       *      To generate a HTML copy,  run:

                     ./configure; make html

              A pre-made HTML can be found at: `http://www.tux.org/pub/knaff/fdutils'

       *      To generate an info copy (browsable using emacs' info mode), run:

                     ./configure; make info

       The texinfo doc looks most pretty when printed or as HTML.  Indeed, in the info version certain  examples
       are difficult to read due to the quoting conventions used in info.

Description

          fdrawcmd [drive=drive] [rate=rate]
          [length=length] [repeat=repeat]
          [cylinder=physical-cyl] command [parameters ...] [mode]

       fdrawcmd is used to send raw commands to the floppy disk controller, after having selected a given drive.
       You must have write permission to the selected drive.

       When writing to a disk, data is read from stdin; when reading, data is  printed  to  stdout.   Diagnostic
       messages,  return values from the controller, and the value of the disk change line after the command are
       printed to stderr.

Options

       All numbers may be given in octal (0211), decimal (137), or hexadecimal (0x89).

       drive=drive
              Selects the drive.  The default is drive 0 (`/dev/fd0').

       rate=rate
              Selects the data transfer rate. Use 0 for high density disks, 1 for double density 5 1/4 disks (or
              2 Mbps tapes, if the appropriate rate table is selected), and 2 for double density 3 1/2 disks.

       length=length
              Describes  the  length  of the transferred data for commands reading from and writing to the disk.
              The default is to continue until end of file.

       repeat=count
              Repeat the command count times.  This only works correctly for commands which don't  do  any  data
              transfer.

       cylinder=count
              Seek to the given cylinder before executing the command

       command
              The  name  of  the  command to send.  command may be a spelled out name (like read or write), or a
              number representing the commands floppy disk controller opcode.  A named  command  has  already  a
              mode  associated  with  it,  whereas for a number the mode parameter should be described using the
              mode option.

       parameters
              The parameters for the command (optional, not all commands need parameters).

       mode   Various flags or'ed together describing the properties of the command.

Commands

       The description of the various floppy commands given in this manpage is very sketchy.  For  more  details
       get the 82078 spec sheet which can be found at:

          http://www-techdoc.intel.com/docs/periph/fd_contr/datasheets/

       Look  for  the  chapter  COMMAND  SET/DESCRIPTIONS.   Older  FDCs  only  support a subset of the commands
       described therein, but the syntax for the commands that do exist is the same.

   Commands available on all FDCs
       read drvsel cyl head sect szcod spt rw-gap szcod2
              Reads length bytes of data from the disk.  drvsel is the drive selector. Bit 0 and 1 describe  the
              drive,  and  bit  2  describes  the  head.  The remaining parameters give the cylinder, head (yes,
              again), sector, size of the sector (128 * 2 ^ szcod), sectors per track  (spt,  this  is  used  to
              switch  to  the  second  head  when the first side has been read), and size of the read-write gap.
              szcod2 should be 0xff.  read returns ST0 ST1 ST2 and cyl head sect szcod of the next sector to  be
              read; see `/usr/include/linux/fdreg.h' .

              N.B.  Certain  newer  floppy disk controllers are buggy, and do not correctly recognize the end of
              transfer when operating in virtual DMA mode.  For these, you need to set spt to the id of the last
              sector  to  be read (for example, if you intend to read sectors 2, 3, 4, set spt to 4, even if the
              disk has more sectors), and set the no-mt flag.

       write drvsel cyl head sect szcod spt rw-gap szcod2
              Analogous to read.

       sense drvsel
              Returns the third status byte (ST3)

       recalibrate drvsel
              Recalibrates the drive and returns ST0 ST1.

       seek drvsel cyl
              Moves the head to cyl and returns ST0 ST1.

       specify drvsel spec1 spec2
              Specify various parameters to the drive.

       format drvsel szcod sect-per-track fmt-gap fmt-fill
              Formats the cylinder. The new sectors are filled with fmt-fill.  The header information comes from
              the  input,  which  is  made  up  of  cyl head sect szcod quadruples. The szcod parameter from the
              command line is used to describe the actual size of the sectors, and the szcod from the  input  is
              used  to  write  into  the  header.  However, the first write to these sectors will use the header
              information, and might overwrite the following sectors if the szcod  parameter  from  the  command
              line was too small.

       readid drvsel
              reads  the  first  sector header that comes and returns ST0 ST1 ST2 and cyl head sect szcod of the
              encountered header.

   Commands available on 82072 and later
       dumpregs
              Prints the contents of the FDCs registers, if supported.

   Commands available on 82072A and later
       configure conf1 conf2 conf3
              Configures FIFO operation.

   Commands available on 82077 and later
       version
              Echoes 0x90 if the FDC is more recent than 82072A, and 0x80 otherwise

       perpendicular rate
              Sets the perpendicular mode.  Use 0 for normal, 2 for 500kb/s perpendicular,  and  3  for  1  Mb/s
              perpendicular.

       seek_out drvsel n
              does a relative seek of n cylinders towards cylinder 0.

       seek_in  drvsel n
              does a relative seek of n cylinders away from cylinder 0.

   Commands available on 82077AA and later
       lock   Locks the FIFO configuration, so that it survives a FDC software reset.

       unlock
              Unlock the FIFO configuration

   Commands available on 82078
       partid
              echoes a byte describing the type of the FDC in the 3 high bits, and the stepping in the three low
              bits.

       powerdown powerconf
              configures automatic power down of the FDC. The old configuration is echoed

       option iso
              enables/disables ISO formats. Odd values of iso enable these formats, whereas even values  disable
              them. ISO formats don't have index headers, and thus allow to fit slightly more data on a disk.

       save   prints out 16 internal registers of the FDC.

       restore r1 r2 r3 ... r16
              restores the 16 internal registers of the FDC.

       format_n_write drvsel szcod sect-per-track fmt-gap fmt-fill
              formats  the  cylinder  and  writes initial data to it. The input data is made up of a sequence of
              headers (4 bytes) and data: header1 data1 header2 data2 ... headern datan

       drivespec dspec1 dspec2 ... specn terminator
              chooses rate tables for various drives. Each dspec byte describes one drive.  Bits  0  and  1  say
              which  drive  is  described.  Bits  2  and  3  describe  the  rate  table. Only tables 0 and 2 are
              interesting. Both tables only differ in the meaning of rate 1. For table 0 (the default) rate 0 is
              300  kb/s  (used  for 5 1/4 DD disks), whereas for table 1 it is 2 Mbps (used for fast floppy tape
              drives). Bit 4 is the precompensation table select bit. It should be set to 0. Bit 5-7  should  be
              zero  as well. The terminator byte ends the drivespec command. It is either 0xc0 or 0x80. If it is
              0xc0, no result phase follows; if it is 0x80, the current data rate table  configuration  for  the
              four drives is echoed.

Modes

       The  mode  option  is only needed when you describe the command as a numerical value. Some mode names are
       also valid command names. They are considered as command name if the command name has not yet been given,
       and as mode name otherwise.

        If  you give a command name followed by explicit modes, both the implicit flags of the command name, and
       the explicit modes are or'ed together.

        If on the other hand you give a command name preceded by explicit modes, only  the  explicit  modes  are
       or'ed together.

       read   Read data from disk using DMA.

       write  Write data to the disk.

       intr   Wait for an interrupt.

       spin   wait for the disk to spin up

       disk   Aborts  the  operation  if  no  disk is in the drive. This only works if you also chose a physical
              cylinder to seek to.

       no-motor
              Don't switch on the drive motor while issuing the command

       no-motor-after
              Switch off the motor immediately after the command returns.

       fm     Uses the FM version of the read, readid, write and format commands.

       no-mt  Do not use MT (multitrack) mode for the read, readid and write commands. This is needed on certain
              broken  FDC's  which  don't  recognize end of transfer when running in nodma mode. In order to use
              these safely, set no-mt, and chose the id of the last sector to be read as sect-per-track.

       fdrawcmd opens the device node with the NDELAY flag. This  means  that  the  driver  should  not  try  to
       autodetect  the  disk  type (it might not be formatted), and that it should not reset the FDC. If a reset
       was needed, the command simply fails. If that happens, execute  floppycontrol  --resetnow  0  ,  and  try
       again.

See Also