Provided by: nfdump-sflow_1.6.12-0.2_amd64 bug

NAME

       sfcapd - sflow capture daemon

SYNOPSIS

       sfcapd [options]

DESCRIPTION

       sfcapd  is  the  sflow  capture  daemon  of the nfdump tools. It reads sflow data from the
       network and stores it into nfcapd compatible files.   The  output  file  is  automatically
       rotated  and  renamed  every  n  minutes  -  typically  5  min  -  according the timestamp
       YYYYMMddhhmm of the interval e.g. nfcapd.200407110845 contains the  data  from  July  11th
       2004 08:45 onward. sfcapd supports sFlow version 4 and 5 datagrams.

       Sflow  is  an  industry standard developed by InMon Corporation.  For more information see
       http://sflow.org.

OPTIONS

       -p portnum
          Specifies the port number to listen. Default port is 6343

       -b bindhost
          Specifies the hostname/IPv4/IPv6 address to bind for listening. Can be an IP address or
          a  hostname,  resolving  to  an  IP  address attached to an interface.  Defaults to any
          available IPv4 interface, if not specified.

       -4 Forces sfcapd to listen on IPv4 addresses only. Can be  used  together  with  -b  if  a
          hostname has an IPv4 and IPv6 address record. Depending on the socket implementation -6
          also accepts IPv4 data.

       -6 Forces sfcapd to listen on IPv6 addresses only. Can be  used  together  with  -b  if  a
          hostname has an IPv4 and IPv6 address record.

       -j MulticastGroup
          Join the specified IPv6 or IPv6 multicast group for listening.

       -R host[/port}
          Enable  packet  repeater.  Send all incoming packets to another host and port.  host is
          either a valid IPv4/IPv6 address, or a valid simbolic hostname,  which  resolves  to  a
          IPv6  or  IPv4  address.  port  may  be ommited and defaults to port 6343. Note: Due to
          IPv4/IPv6 accepted addresses the port separator is '/'.

       -I IdentString ( capital letter i )
          Specifies an ident string, which describes the source e.g. the name of the router. This
          string  is  put into the stat record to identify the source. Default is 'none'. This is
          for compatibility with nfdump 1.5.x and used to specify a single sflow source. See -n

       -l base_directory ( letter ell )
          Specifies the base directory to  store  the  output  files.   If  a  sub  hierarchy  is
          specified  with -S the final directory is concatenated to base_directory/sub_hierarchy.
          This is for compatibility with nfdump 1.5.x and used to specify a single sflow  source.
          See -n

       -n <Ident,IP,base_directory>
          Configures  an  sflow  source  named Ident and identified by source IP address IP.  The
          base directory for the flow files is base_directory. If a sub  hierarchy  is  specified
          with  -S  the final directory is concatenated to base_directory/sub_hierarchy. Multiple
          netflow sources can be specified. All data is sent to the same port  specified  by  -p.
          Note: You must not mix -n option with -I and -l. Use either syntax.

       -f <pcap_file>
          Read  sflow  packets from a give pcap_file instead of the network. This requires sfcapd
          to be compiled with the pcap option and is intended for debugging only.

       -S <num>
          Allows to specify an additional directory sub hierarchy to store the  data  files.  The
          default is 0, no sub hierarchy, which means the files go directly in the base directory
          (-l). The base directory (-l) is concatenated with the specified sub  hierarchy  format
          to form the final data directory.  The following hierarchies are defined:
            0 default     no hierarchy levels
            1 %Y/%m/%d    year/month/day
            2 %Y/%m/%d/%H year/month/day/hour
            3 %Y/%W/%u    year/week_of_year/day_of_week
            4 %Y/%W/%u/%H year/week_of_year/day_of_week/hour
            5 %Y/%W/%u    year/week_of_year/day_of_week
            6 %Y/%W/%u/%H year/week_of_year/day_of_week/hour
            7 %Y/%j       year/day-of-year
            8 %Y/%j/%H    year/day-of-year/hour
            9 %Y-%m-%d    year-month-day
           10 %Y-%m-%d/%H year-month-day/hour

       -T <extension list>
          Specifies  the  list  of  extensions, to be stored in the flow file.  Regardless of the
          extension list, the following sflow data is stored per record: first, last, fwd status,
          tcp  flags,  proto,  (src)tos, src port, dst port, src ipaddr, dst ipaddr, in(packets),
          in(bytes). In addition sfcapd recognises the extensions as described below.

          Extensions:
           sflow extensions:
            1 input/output interface SNMP numbers.
            2 src/dst AS numbers.
            3 src/dst mask, (dst)TOS, direction,
            4 Next hop IP addr
            5 BGP next hop IP addr
            6 src/dst vlan id labels
           10 in_src/out_dst MAC address
           By default extension 1 and 2 are selected, which provides compatibility  with  earlier
           nfdump version.  Extensions can be added/deleted by specifying a ',' separated list of
           extension ids. Each id may be prepended by an optional sign +/- to  add  or  remove  a
           given  id  from  the extension list. The string 'all' means all extensions. Extensions
           7-9 are not available for sfcapd.
           Examples:
           -T all       Enables all possible extensions.
           -T +3,+4     Adds extensions 3 and 4 to the defaults 1 and 2.
           -T all,-5,-6 Set all extensions but 5 and 6
           -T -1,4      Removes default extension 1 and adds extension 4
           Note: Extensions are shared with the  netflow  collector  nfcapd.  Sflow  as  well  as
           netflow data is stored in the same type of extensions.

       -t interval
          Specifies  the  time  interval  in seconds to rotate files. The default value is 300s (
          5min ).

       -w Align file rotation with next n minute ( specified  by  -t  )  interval.   Example:  If
          interval is 5 min, sync at 0,5,10... wall clock minutes Default: no alignment.

       -x cmd
          Run  command  cmd  at the end of every interval, when a new file becomes available. The
          following command expansion is available:
           %f   Replaced by the file name e.g nfcapd.200407110845 inluding any
                sub hierarchy. ( 2004/07/11/nfcapd.200407110845 )
           %d   Replaced by the directory where the file is located.
           %t   Replaced by the time ISO format e.g. 200407110845.
           %u   Replaced by the UNIX time format.
           %i   Replaced ident string given by -I

       -e Auto expire files at every cycle. max lifetime  and  max  filesize  are  defined  using
          nfexpire(1)

       -P pidfile
          Specify name of pidfile. Default is no pidfile.

       -D Daemon  mode: fork to background and detach from terminal.  Nfcapd terminates on signal
          TERM, INT and HUP.

       -u userid
          Change to the user userid as soon as possible. Only root is allowed to use this option.

       -g groupid
          Change to the group groupid as soon as possible. Only root is allowed use this option.

       -B bufflen
          Specifies the socket input buffer length in bytes. For high volume traffic  (  near  GB
          traffic ) it is recommended to set this value as high as possible ( typically > 100k ),
          otherwise you risk to lose packets. The default is OS ( and kernel )  dependent.

       -E Print data records in nfdump raw format to stdout. This option is for debugging purpose
          only, to see how incoming sflow data is processed and stored.

       -z Compress flows. Use fast LZO1X-1 compression in output file.

       -V Print sfcapd version and exit.

       -h Print help text to stdout with all options and exit.

RETURN VALUE

       Returns 0 on success, or 255 if initialization failed.

LOGGING

       sfcapd logs to syslog with SYSLOG_FACILITY LOG_DAEMON For normal operation level 'warning'
       should be fine.  More information is reported at level 'info' and 'debug'.

       A small statistic about the collected flows, as well as errors are reported at the end  of
       every interval to syslog with level 'info'.

EXAMPLES

       Compatible with old sfcapd 1.5.x:
              sfcapd -w -D -l /data/spool/router1 -p 6343 -B 128000 -I router1 -x '/path/some_app
              -r %d/%f'  -P /var/run/sfcapd/sfcapd.router1

       Selectively enabled sender:
              sfcapd -Tall -w -D -n router1,192.168.1.10,/data/spool/router1 -p 6343 -B 128000 -P
              /var/run/sfcapd/sfcapd.router1

NOTES

       sfcapd automatically scales the packets and bytes according the sampling rate.

       Even  with  sflow  version 4 and 5 support, not all available sflow elements are stored in
       the data files. As of this  version,  sfcpad  supports  the  the  same  shared  fields  as
       extensions,  as  it's netflow companion nfcapd for netflow version v9. See nfcapd(1). More
       fields will be supported in future.

       The format of the data files is version independent and compatible nfcapd collected data.

       Socket buffer: Setting the socket buffer size is  system  dependent.   When  starting  up,
       sfcapd  returns  the  number of bytes the buffer was actually set. This is done by reading
       back the buffer size and may differ from what you requested.

SEE ALSO

       nfcapd(1), nfdump(1), nfprofile(1), nfreplay(1)

                                            2009-09-09                                  sfcapd(1)