Provided by: pcp_4.0.1-1_amd64 bug

NAME

       pmlogger - create archive log for performance metrics

SYNOPSIS

       pmlogger [-c configfile] [-h host] [-H hostname] [-K spec] [-l logfile] [-L] [-m note] [-n pmnsfile] [-o]
       [-p  pid]  [-P] [-r] [-s endsize] [-t interval] [-T endtime] [-u] [-U username] [-v volsize] [-V version]
       [-x fd] [-y] archive

DESCRIPTION

       pmlogger creates the archive logs of performance metric values that  may  be  ``played  back''  by  other
       Performance  Co-Pilot  (see  PCPIntro(1))  tools.   These  logs  form  the  basis of the VCR paradigm and
       retrospective performance analysis services common to the PCP toolkit.

       The mandatory argument archive is the base name for the physical files that constitute an archive log.

       The -V option specifies the version for the archive that is generated.  By default a version 2 archive is
       generated, and the only value currently supported for version is 2.

       Unless directed to another host by the -h option or when directly using PMDAs via the -o option, pmlogger
       will contact the Performance Metrics Collector Daemon (PMCD) on the local host and use that as the source
       of the metric values to be logged.

       To support the required flexibility and control over what is  logged  and  when,  pmlogger  maintains  an
       independent  two  level  logging  state  for  each  instance  of  each  performance metric.  At the first
       (mandatory) level, logging is allowed to be on (with an associated interval between samples), or  off  or
       maybe.   In  the latter case, the second (advisory) level logging is allowed to be on (with an associated
       interval between samples), or off.

       The mandatory level allows universal specification that some metrics must  be  logged,  or  must  not  be
       logged.   The  default state for all instances of all metrics when pmlogger starts is mandatory maybe and
       advisory off.

       Use pmlc(1) to interrogate and change the logging state once pmlogger is running.

       If a metric's state is mandatory (on or off) and a request is made to change it to mandatory  maybe,  the
       new state is mandatory maybe and advisory off.  If a metric's state is already advisory (on or off) and a
       request is made to change it to mandatory maybe, the current state is retained.

       It  is  not  possible  for  pmlogger  to log specific instances of a metric and all instances of the same
       metric concurrently.  If specific instances are being logged and a request to log all instances is  made,
       then  all  instances  of  the  metric  will be logged according to the new request, superseding any prior
       logging request for the metric.  A request to log all instances of a metric will supersede  any  previous
       request  to  log  all  instances.  A request to log specific instances of a metric when all instances are
       already being logged is refused.  To do this one must turn off logging for all instances  of  the  metric
       first.   In  each  case,  the validity of the request is checked first; for example a request to change a
       metric's logging state to advisory on when it is currently  mandatory  off  is  never  permitted  (it  is
       necessary to change the state to mandatory maybe first).

       Optionally,  each  system  running pmcd(1) may also be configured to run a ``primary'' pmlogger instance.
       This  pmlogger  instance  is  launched  by  $PCP_RC_DIR/pmlogger,  and   is   affected   by   the   files
       $PCP_SYSCONF_DIR/pmlogger/control, $PCP_SYSCONF_DIR/pmlogger/control.d (use chkconfig(8), systemctl(1) or
       similar   platform-specific   commands   to   activate   or   disable  the  primary  pmlogger  instance),
       $PCP_SYSCONFIG_DIR/pmlogger    (environment    variable    settings    for    the    primary    pmlogger)
       $PCP_SYSCONF_DIR/pmlogger/pmlogger.options  (command  line  options  passed  to the primary pmlogger) and
       $PCP_VAR_DIR/config/pmlogger/config.default (the default  initial  configuration  file  for  the  primary
       pmlogger).

       The  primary  pmlogger  instance  is  identified  by the -P option.  There may be at most one ``primary''
       pmlogger instance on each system.  The primary pmlogger instance (if any) must be  running  on  the  same
       host as the pmcd(1) to which it connects (if any), so the -h and -P options are mutually exclusive.

       Logging  of  some  metrics  is possible even in the absence of a local pmcd(1), using the "local context"
       mode of operation.  This is activated using the -o option, and causes pmlogger to make use of  local  DSO
       PMDAs  instead of communicating with pmcd(1).  When operating using a local context, the -K option may be
       used to control the DSO PMDAs that should be made accessible.  The spec argument conforms to  the  syntax
       described in pmSpecLocalPMDA(3).  More than one -K option may be used.

       When  launched as a non-primary instance, pmlogger will exit immediately if the configuration file causes
       no metric logging to be scheduled.  The -L option overrides  this  behavior,  and  causes  a  non-primary
       pmlogger instance to ``linger'', presumably pending some future dynamic re-configuration and state change
       via  pmlc(1).  pmlogger will also linger without the -L option being used if all the metrics to be logged
       are logged as once only metrics. When the once only metrics have been logged, a warning message  will  be
       generated stating that the event queue is empty and no more events will be scheduled.

       By default all diagnostics and errors from pmlogger are written to the file pmlogger.log in the directory
       where pmlogger is launched.  The -l option may be used to override the default behavior.  If the log file
       cannot be created or is not writable, output is written to standard error instead.

       If  specified,  the  -s  option instructs pmlogger to terminate after a certain size in records, bytes or
       time units has been accumulated.  If endsize is an integer then endsize records will be  written  to  the
       log.   If  endsize  is  an  integer suffixed by b or bytes then endsize bytes of the archive data will be
       written out (note, however, that archive log record boundaries will not be broken and so this  limit  may
       be  slightly surpassed).  Other viable file size units include: K, Kb, KiB, Kbyte, Kilobyte for kilobytes
       and M, Mb, MiB, Mbyte, Megabyte for megabytes and G, Gb, GiB, Gbyte, Gigabyte for gigabytes.  These units
       may be optionally suffixed by an s and may be of mixed case.  Alternatively endsize may be an integer  or
       a  floating point number suffixed using a time unit as described in PCPIntro(1) for the interval argument
       (to the standard PCP -t command line option).
       Some examples of different formats:
          -s 100
          -s 100bytes
          -s 100K
          -s 100Mb
          -s 10Gbyte
          -s 10mins
          -s 1.5hours
       The default is for pmlogger to run forever.

       The -r option causes the size of the physical record(s) for  each  group  of  metrics  and  the  expected
       contribution of the group to the size of the PCP archive for one full day of collection to be reported in
       the  log  file.   This  information  is reported the first time each group is successfully written to the
       archive.

       The -U option specifies the user account under which to run pmlogger.  The default is  the  current  user
       account  for  interactive  use.   When run as a daemon, the unprivileged "pcp" account is used in current
       versions of PCP, but in older versions the superuser account ("root") was used by default.

       The log file is potentially a multi-volume data set, and the -v option causes pmlogger  to  start  a  new
       volume after a certain size in records, bytes, or time units has been accumulated for the current volume.
       The  format of this size specification is identical to that of the -s option (see above).  The default is
       for pmlogger to create a single volume log.  Additional volume switches can also be forced asynchronously
       by either using pmlc(1) or sending pmlogger a SIGHUP signal (see below).  Note,  if  a  scheduled  volume
       switch  is  in  operation  due  to  the  -v option, then its counters will be reset after an asynchronous
       switch.

       Independent of any -v option, each volume of an archive is  limited  to  no  more  than  2^31  bytes,  so
       pmlogger will automatically create a new volume for the archive before this limit is reached.

       Normally  pmlogger  operates  on the distributed Performance Metrics Name Space (PMNS), however if the -n
       option is specified an alternative local PMNS is loaded from the file pmnsfile.

       Under normal circumstances, pmlogger will run forever (except for a -s option or a  termination  signal).
       The  -T  option  may  be  used  to  limit  the  execution  time using the format of time as prescribed by
       PCPIntro(1).  The time is interpreted within the time zone of the PMCD server, unless the  -y  option  is
       given, within which case the time zone at this logger host is used.
       Some examples of different formats:
          -T 10mins
          -T '@ 11:30'
       From this it can be seen that -T 10mins and -s 10mins perform identical actions.

       Alternatively,  pmlogger  runtime  may  be  limited to the lifetime of another process by using the -p or
       --PID option to nominate the PID of the process of interest.  In this case the pmlogger  will  exit  when
       the other process no longer exists.

       When  pmlogger  receives  a  SIGHUP  signal, the current volume of the log is closed, and a new volume is
       opened.  This mechanism (or the alternative mechanism via pmlc(1)) may be used to manage  the  growth  of
       the  log  files  -  once  a  log  volume  is  closed, that file may be archived without ill-effect on the
       continued operation of pmlogger.  See also the -v option above.

       Historically the buffers for the current log may be flushed to disk using the flush command  of  pmlc(1),
       or  by  sending pmlogger a SIGUSR1 signal or by using the -u option.  The current version of pmlogger and
       the libpcp routines that underpin pmlogger unconditionally use unbuffered writes and a  single  fwrite(3)
       for  each logical record written, and so ``flushing'' does not force any additional data to be written to
       the file system.  The -u option, the SIGUSR1 handling and the pmlc(1)  flush  command  are  retained  for
       backwards compatibility.

       When  launched  with  the  -x  option,  pmlogger  will  accept  asynchronous control requests on the file
       descriptor fd.  This option is only expected to be used  internally  by  PCP  applications  that  support
       ``live record mode''.

       The  -m option allows the string note to be appended to the map file for this instance of pmlogger in the
       $PCP_TMP_DIR/pmlogger directory.  This is currently used internally to document the file descriptor  (fd)
       when  the  -x option is used, or to indicate that this pmlogger instance was started under the control of
       pmlogger_check(1).

       The -H option allows the hostname written into the archive label to be overridden.  This mirrors  the  -H
       option of pmcd(1) , but allows it to be specified on the pmlogger process. Without this option, the value
       returned from the logged pmcd(1) is used.

CONFIGURATION FILE SYNTAX

       The  configuration  file may be specified with the -c option.  If it is not, configuration specifications
       are read from standard input.

       If configfile does not exist, then a search is made in the directory $PCP_VAR_DIR/config/pmlogger  for  a
       file  of  the  same  name,  and  if  found that file is used, e.g. if config.mumble does not exist in the
       current  directory  and  the  file  $PCP_VAR_DIR/config/pmlogger/config.mumble  does   exist,   then   -c
       config.mumble and -c $PCP_VAR_DIR/config/pmlogger/config.mumble are equivalent.

       The syntax for the configuration file is as follows.

       1.   Words are separated by white space (space, tab or newline).

       2.   The symbol ``#'' (hash) introduces a comment, and all text up to the next newline is ignored.

       3.   Keywords (shown in bold below) must appear literally (i.e. in lower case).

       4.   Each specification begins with the optional keyword log, followed by one of the states mandatory on,
            mandatory off, mandatory maybe, advisory on or advisory off.

       5.   For  the  on  states,  a  logging interval must follow using the syntax ``once'', or ``default'', or
            ``every N timeunits'', or simply ``N timeunits'' - N is an unsigned integer, and timeunits is one of
            the keywords msec, millisecond, sec, second, min, minute, hour or the plural  form  of  one  of  the
            above.
            Internal  limitations require the interval to be smaller than (approximately) 74 hours.  An interval
            value of zero is a synonym for once.  An interval of  default  means  to  use  the  default  logging
            interval  of  60  seconds;  this  default  value may be changed to interval with the -t command line
            option.

            The interval argument follows the syntax described in PCPIntro(1), and in the simplest form  may  be
            an unsigned integer (the implied units in this case are seconds).

       6.   Following the state and possible interval specifications comes a ``{'', followed by a list of one or
            more  metric  specifications and a closing ``}''.  The list is white space (or comma) separated.  If
            there is only one metric specification in the list, the braces are optional.

       7.   A metric specification consists of a metric name optionally followed by a  set  of  instance  names.
            The  metric name follows the standard PCP naming conventions, see pmns(5), and if the metric name is
            a non-leaf node in the PMNS (see pmns(5)), then pmlogger will recursively descend the PMNS and apply
            the logging specification to all descendent metric names that are leaf nodes in the PMNS.   The  set
            of  instance  names  is a ``['', followed by a list of one or more space (or comma) separated names,
            numbers or strings, and a closing ``]''.  Elements in the list that are numbers are  assumed  to  be
            internal  instance identifiers, other elements are assumed to be external instance identifiers - see
            pmGetInDom(3) for more information.

            If no instances are given, then the logging  specification  is  applied  to  all  instances  of  the
            associated metric.

       8.   There may be an arbitrary number of logging specifications.

       9.   As  of PCP version 4.0 and later, any metric name specification that does not resolve to a leaf node
            in the PMNS is added to an internal list of possible dynamic subtree roots.  PMDAs  can  dynamically
            create  new metrics below a dynamic root node in their PMNS, and send a notification to clients that
            the PMNS has changed, see pmdaExtSetFlags(3) and in particular the METRIC CHANGES  section  for  API
            details.   This  mechanism is currently supported by pmdaprometheus(1) and pmdammv(1).  When a fetch
            issued by pmlogger returns with the PMDA_EXT_NAMES_CHANGE  flag  set,  pmlogger  will  traverse  the
            internal  list  of  possible  dynamic  subtree  nodes  and dynamically discover any new metrics.  In
            effect, as of PCP version 4.0 and later, pmlogger can be configured to dynamically log  new  metrics
            that appear in the future, after the configuration file is initially parsed.

       10.  Following  all  of  the  logging  specifications,  there  may be an optional access control section,
            introduced by the literal token [access].  Thereafter  come  access  control  rules  that  allow  or
            disallow operations from particular hosts or groups of hosts.

            The  operations may be used to interrogate or control a running pmlogger using pmlc(1) and fall into
            the following classes:

            enquire        interrogate the status of pmlogger and the metrics it is logging
            advisory       Change advisory logging.
            mandatory      Change mandatory logging.
            all            All of the above.

            Access control rules are of the form ``allow hostlist : operationlist ;'' and ``disallow hostlist  :
            operationlist ;''.

            The hostlist follows the syntax and semantics for the access control mechanisms used by PMCD and are
            fully  documented  in  pmcd(1).   An  operationslist  is  a  comma  separated list of the operations
            advisory, mandatory, enquire and all.

            A missing [access] section allows all access and is equivalent to allow * : all;.

       The configuration (either from standard input or configfile) is initially scanned by  pmcpp(1)  with  the
       options -rs and -I $PCP_VAR_DIR/config/pmlogger.  This extends the configuration file syntax with include
       file processing (%include), a common location to search for include files ($PCP_VAR_DIR/config/pmlogger),
       macro  definitions  (%define),  macro  expansion  (%name  and %{name}) and conditional inclusion of lines
       (%ifdef name ... %else ... %endif and %ifndef name ... %else ... %endif).

EXAMPLES

       For each PCP utility, there is a sample pmlogger configuration file that  could  be  used  to  create  an
       archive  log  suitable for replaying with that tool (i.e. includes all of the performance metrics used by
       the   tool).     For    a    tool    named    foo    this    configuration    file    is    located    in
       $PCP_VAR_DIR/config/pmlogger/config.foo.

       The  following  is  a simple default configuration file for a primary pmlogger instance, and demonstrates
       most of the capabilities of the configuration specification language.

            log mandatory on once { hinv.ncpu hinv.ndisk }
            log mandatory on every 10 minutes {
                disk.all.write
                disk.all.read
                network.interface.in.packets [ "et0" ]
                network.interface.out.packets [ "et0" ]
                nfs.server.reqs [ "lookup" "getattr" "read" "write" ]
            }

            log advisory on every 30 minutes {
                environ.temp
                pmcd.pdu_in.total
                pmcd.pdu_out.total
            }

            %include "macros.default"

            %ifdef %disk_detail
            log mandatory on %disk_detail_freq {
                disk.dev
            }
            %endif

            [access]
            disallow * : all except enquire;
            allow localhost : mandatory, advisory;

FILES

       archive.meta
                 metadata (metric descriptions, instance domains, etc.) for the archive log
       archive.0 initial volume of metrics values (subsequent volumes have suffixes 1, 2, ...)
       archive.index
                 temporal index to support rapid random access to the other files in the archive log
       $PCP_TMP_DIR/pmlogger
                 pmlogger maintains the files in this directory as  the  map  between  the  process  id  of  the
                 pmlogger  instance and the IPC port that may be used to control each pmlogger instance (as used
                 by pmlc(1))
       $PCP_VAR_DIR/config/pmlogger/config.default
                 default configuration file for the primary logger instance launched from $PCP_RC_DIR/pmlogger
       $PCP_VAR_DIR/config/pmlogger/config.*
                 assorted configuration files suitable for creating logs that may be subsequently replayed  with
                 the PCP visualization and monitoring tools
       $PCP_LOG_DIR/pmlogger/hostname
                 Default  directory  for PCP archive files for performance metric values collected from the host
                 hostname.
       $PCP_SYSCONFIG_DIR/pmlogger
                 additional environment variables that will be set when the primary pmlogger instance  executes.
                 Only settings of the form "PMLOGGER_VARIABLE=value" will be honoured.
       ./pmlogger.log
                 (or   $PCP_LOG_DIR/pmlogger/hostname/pmlogger.log   when   started   automatically   by  either
                 $PCP_RC_DIR/pmlogger or one of the pmlogger(1) monitoring scripts such as pmlogger_check(1))
                 all messages and diagnostics are directed here

ENVIRONMENT

       Normally pmlogger creates a socket to receive control messages from pmlc(1) on the first available TCP/IP
       port numbered 4330 or higher.   The  environment  variable  PMLOGGER_PORT  may  be  used  to  specify  an
       alternative starting port number.

       If set to the value 1, the PMLOGGER_LOCAL environment variable will cause pmlogger to run in a localhost-
       only mode of operation, where it binds only to the loopback interface.

       The  PMLOGGER_MAXPENDING variable can be set to indicate the maximum length to which the queue of pending
       pmlc connections may grow.

       The default sampling interval used by pmlogger can be set using the PMLOGGER_INTERVAL  variable  (if  not
       set,  60  seconds  will  be  used).   Both the command line and directives in the configuration file will
       override this value.  It is an integer in units of seconds.

PCP ENVIRONMENT

       Environment variables with the prefix PCP_ are used to parameterize the file and directory names used  by
       PCP.   On  each  installation, the file /etc/pcp.conf contains the local values for these variables.  The
       $PCP_CONF variable may be used to specify an alternative configuration file, as described in pcp.conf(5).

SEE ALSO

       PCPIntro(1),  pmcd(1),  pmdumplog(1),  pmlc(1),  pmlogger_check(1),   systemctl(1),   pmSpecLocalPMDA(3),
       pcp.conf(5), pcp.env(5), pmlogger(5), pmns(5) and chkconfig(8).

DIAGNOSTICS

       The  archive logs are sufficiently precious that pmlogger will not truncate an existing physical file.  A
       message of the form
        ...: "foo.index" already exists, not over-written
        ...: File exists
       indicates this situation has arisen.  You must explicitly remove the files and launch pmlogger again.

       There may be at most one primary pmlogger instance per monitored  host;  attempting  to  bend  this  rule
       produces the error:
        pmlogger: there is already a primary pmlogger running

       Various other messages relating to the creation and/or deletion of files in $PCP_TMP_DIR/pmlogger suggest
       a permission problem on this directory, or some feral files have appeared therein.

Performance Co-Pilot                                   PCP                                           PMLOGGER(1)