bionic (5) sane-coolscan2.5.gz

Provided by: libsane-common_1.0.27-1~experimental3ubuntu2.4_all bug

NAME

       sane-coolscan2 - SANE backend for Nikon Coolscan film scanners

DESCRIPTION

       The  sane-coolscan2  library  implements a SANE (Scanner Access Now Easy) backend that provides access to
       Nikon Coolscan film scanners.  Some functions of this backend should be considered beta-quality software.
       Most  functions  have  been  stable  for  a long time, but of course new development can not and will not
       function properly from the very first day. Please report any strange behaviour to the maintainer  of  the
       backend.

       At present, the following scanners are known to work with this backend:

              Model:                       Connection Type
              ---------------------------  -------------------
              LS-30 (Coolscan III)         SCSI
              LS-2000                      SCSI
              LS-40 ED (Coolscan IV)       USB
              LS-4000 ED                   IEEE 1394
              LS-8000 ED                   IEEE 1394

       Please send mail to the backend author (andras@users.sourceforge.net) to report successes or failures.

OPTIONS

       The  options  the  backend  supports can either be selected through command line options to programs like
       scanimage or through GUI elements in xscanimage or xsane.

       Valid command line options and their syntax can be listed by using
              scanimage --help -d coolscan2:<interface>:<device>
       where <interface> and <device> specify the device in question, as in the  configuration  file  (see  next
       section).  The  -d  parameter  and its argument can be omitted to obtain information on the first scanner
       identified. Use the command
              scanimage -L
       to list all devices recognized by your SANE installation.

       The options should be fully described by the description  or  tooltips  given  by  frontend.  Here  is  a
       description  of  some  of  the  most important options, in the syntax with which they must be supplied to
       scanimage:

       --frame <n>
              This option specifies which frame to operate on, if a motorized film strip feeder or  APS  adapter
              are  used.  The  frame number <n> ranges from 1 to the number of frames available, which is sensed
              each time the backend is initialized (usually each time you start the frontend).

       --subframe <x>
              This option shifts the scan window by the specified amount (default unit is mm).

       --infrared=yes/no
              If set to "yes", the scanner will read the infrared  channel,  thus  allowing  defect  removal  in
              software.  The  infrared  image is read during a second scan, with no options altered. The backend
              must not be restarted between the scans.   If  you  use  scanimage,  perform  a  batch  scan  with
              batch-count=2 to obtain the IR information.

       --depth <n>
              Here  <n>  can either be 8 or the maximum number of bits supported by the scanner (10, 12, or 14).
              It specifies whether or not the scanner reduces the scanned data to 8 bits before  sending  it  to
              the  backend.  If 8 bits are used, some information and thus image quality is lost, but the amount
              of data is smaller compared to higher depths. Also, many imaging programs and image formats cannot
              handle depths greater than 8 bits.

       --autofocus
              Perform  autofocus  operation. Unless otherwise specified by the other options ( --focus-on-centre
              and friends), focusing is performed on the centre of the selected scan area.

       --ae-wb

       --ae   Perform a pre-scan to calculate exposure values automatically.  --ae-wb will  maintain  the  white
              balance, while --ae will adjust each channel separately.

       --exposure
              Multiply  all  exposure  times  with this value. This allows exposure correction without modifying
              white balance.

       --load Load the next slide when using the slide loader.

       --eject
              Eject the film strip or mounted slide when using the slide loader.

       --reset
              Reset scanner. The scanner will perform the same action as when power is turned on: it will  eject
              the  film  strip  and calibrate itself. Use this whenever the scanner refuses to load a film strip
              properly, as a result of which --eject does not work.

CONFIGURATION FILE

       The configuration file @CONFIGDIR@/coolscan2.conf specifies the device(s)  that  the  backend  will  use.
       Owing to the nature of the supported connection types SCSI, USB, and IEEE 1394, the default configuration
       file supplied with the SANE distribution should work without being edited.

       Each line in the configuration file is either of the following, where all entries are case-sensitive:

       blank or starting with a '#' character
              These lines are ignored, thus '#' can be used to include comments.

       containing only the word "auto"
              This instructs the backend to probe for a scanner by scanning the  buses  for  devices  with  know
              identifiers. This is the action taken when no configuration file is present.

       a line of the form <interface>:<device>
              Here  <interface>  can  be one of "scsi" or "usb", and <device> is the device file of the scanner.
              Note that IEEE 1394 devices are handled by the SBP-2 module in the kernel and appear  to  SANE  as
              SCSI devices.

FILES

       @LIBDIR@/libsane-coolscan2.a
              The static library implementing this backend.

       @LIBDIR@/libsane-coolscan2.so
              The shared library implementing this backend (present on systems that support dynamic loading).

       @CONFIGDIR@/coolscan2.conf
              Configuration file for this backend, read each time the backend is initialized.

ENVIRONMENT

       SANE_DEBUG_COOLSCAN2
              If  the  library  was  compiled with debug support enabled, this environment variable controls the
              debug level for this backend.  E.g., a value of 128 requests  all  debug  output  to  be  printed.
              Smaller levels reduce verbosity.

SEE ALSO

       sane-scsi(5), sane-usb(5), scanimage(1), xscanimage(1), xsane(1)

BUGS

       Currently, the SANE protocol does not allow automatically updating options whenever the hardware changes.
       Thus the number of choices for the --frame option will be fixed when the backend is initialized  (usually
       when  the  user  runs the frontend). In particular, if there is no film strip in the automatic film strip
       feeder when the backend is initialized, the frame option will not appear at  all.  Also,  restarting  the
       frontend after swapping film adapters is strongly recommended.

       Linux  kernels  prior  to  2.4.19  had  a patch that truncated INQUIRY data from IEEE 1394 scanners to 36
       bytes, discarding vital information about the scanner. The IEEE 1394  models  therefore  only  work  with
       2.4.19 or later.

       No  real  bugs currently known, please report any to the backend maintainer or the SANE developers' email
       list.

AUTHORS

       The backend is written and maintained by András Major (andras@users.sourceforge.net).

@PACKAGEVERSION@                                   11 Jul 2008                                 sane-coolscan2(5)