NAME

       pmlogger - create an archive for performance metrics

SYNOPSIS

       pmlogger  [-CLNoPruy?]   [-c  conffile] [-d directory] [-h host] [-H hostname] [-I version] [-K spec] [-l
       logfile] [-m note] [-n pmnsfile] [-p pid] [-s endsize] [-t  interval]  [-T  endtime]  [-U  username]  [-v
       volsize] [-V version] [-x fd] archive

DESCRIPTION

       pmlogger  creates  the  archives  of  performance  metric  values  that  may  be ``played back'' by other
       Performance Co-Pilot (see PCPIntro(1)) tools.  These  logs  form  the  basis  of  the  VCR  paradigm  and
       retrospective performance analysis services common to the PCP toolkit.

       The  mandatory  argument archive is the base name for the physical files that constitute an archive.  The
       archive argument may contain strftime(3) meta-characters, which will be substituted prior to creating the
       archive files.  When pmlogger is run as a service (see pmlogger_daily(1)), the standard archive base name
       template is %Y%m%d.%H.%M.

       The -V option specifies the version for the archive that is generated.  By default  the  archive  version
       $PCP_ARCHIVE_VERSION  (set to 3 in current PCP releases) is used, and the only values currently supported
       for version are 2 or 3.

       Unless directed to another host by the -h option or when directly using PMDAs via the -o option, pmlogger
       will contact the Performance Metrics Collector Daemon (PMCD) on the local host and use that as the source
       of the metric values to be logged.

       To support the required flexibility and control over what is  logged  and  when,  pmlogger  maintains  an
       independent  two  level  logging  state  for  each  instance  of  each  performance metric.  At the first
       (mandatory) level, logging is allowed to be on (with an associated interval between samples), or  off  or
       maybe.   In  the latter case, the second (advisory) level logging is allowed to be on (with an associated
       interval between samples), or off.

       The mandatory level allows universal specification that some metrics must  be  logged,  or  must  not  be
       logged.   The  default state for all instances of all metrics when pmlogger starts is mandatory maybe and
       advisory off.

       Use pmlc(1) to interrogate and change the logging state once pmlogger is running.

       If a metric's state is mandatory (on or off) and a request is made to change it to mandatory  maybe,  the
       new state is mandatory maybe and advisory off.  If a metric's state is already advisory (on or off) and a
       request is made to change it to mandatory maybe, the current state is retained.

       It is not possible for pmlogger to log specific instances of a metric  and  all  instances  of  the  same
       metric  concurrently.  If specific instances are being logged and a request to log all instances is made,
       then all instances of the metric will be logged according to  the  new  request,  superseding  any  prior
       logging  request  for the metric.  A request to log all instances of a metric will supersede any previous
       request to log all instances.  A request to log specific instances of a metric  when  all  instances  are
       already  being  logged  is refused.  To do this one must turn off logging for all instances of the metric
       first.  In each case, the validity of the request is checked first; for example a  request  to  change  a
       metric's  logging  state  to  advisory  on  when  it is currently mandatory off is never permitted (it is
       necessary to change the state to mandatory maybe first).

       Optionally, each system running pmcd(1) may also be configured to run a  ``primary''  pmlogger  instance.
       This   pmlogger   instance   is   launched   by  $PCP_RC_DIR/pmlogger,  and  is  affected  by  the  files
       $PCP_SYSCONF_DIR/pmlogger/control, $PCP_SYSCONF_DIR/pmlogger/control.d/*, (use chkconfig(8), systemctl(1)
       or   similar   platform-specific  commands  to  activate  or  disable  the  primary  pmlogger  instance),
       $PCP_SYSCONFIG_DIR/pmlogger    (environment    variable    settings    for    the    primary    pmlogger)
       $PCP_SYSCONF_DIR/pmlogger/pmlogger.options  (command  line  options  passed  to the primary pmlogger) and
       $PCP_VAR_DIR/config/pmlogger/config.default (the default  initial  configuration  file  for  the  primary
       pmlogger).

       The  primary  pmlogger  instance  is  identified  by the -P option.  There may be at most one ``primary''
       pmlogger instance on each system.  The primary pmlogger instance (if any) must be  running  on  the  same
       host as the pmcd(1) to which it connects (if any), so the -h and -P options are mutually exclusive.

       Logging  of  some  metrics  is possible even in the absence of a local pmcd(1), using the "local context"
       mode of operation.  This is activated using the -o option, and causes pmlogger to make use of  local  DSO
       PMDAs  instead of communicating with pmcd(1).  When operating using a local context, the -K option may be
       used to control the DSO PMDAs that should be made accessible.  The spec argument conforms to  the  syntax
       described in pmSpecLocalPMDA(3).  More than one -K option may be used.

       When  launched as a non-primary instance, pmlogger will exit immediately if the configuration file causes
       no metric logging to be scheduled.  The -L option overrides  this  behavior,  and  causes  a  non-primary
       pmlogger instance to ``linger'', presumably pending some future dynamic re-configuration and state change
       via pmlc(1).  pmlogger will also linger without the -L option being used if all the metrics to be  logged
       are  logged as once only metrics.  When the once only metrics have been logged, a warning message will be
       generated stating that the event queue is empty and no more events will be scheduled.

       By default all diagnostics and errors from pmlogger are written to the file pmlogger.log in the directory
       where pmlogger is launched.  The -l option may be used to override the default behavior.  If the log file
       cannot be created or is not writable, output is written to standard error instead.  If  the  logfile  for
       the  -l  option is "-" (i.e.  -l-) then log messages are written to the standard output stream.  This can
       be particularly useful when running pmlogger manually, rather than as a service daemon.

       The -N option directs pmlogger to notify a service manager, typically systemd(1), when it has started and
       is  about to begin writing PCP archives.  This option would only normally be used when pmlogger is run as
       a   daemon   service   under   the   control   of   a   service   manager.    For   more   details,   see
       __pmServerNotifyServiceManagerReady(3)  and  systemd(1).   On platforms that do not use a service manager
       that supports notifications, the -N option is basically a no-op.

       If specified, the -s option instructs pmlogger to terminate after a certain size  in  records,  bytes  or
       time  units  has  been accumulated.  If endsize is an integer then endsize records will be written to the
       archive.  If endsize is an integer suffixed by b or bytes then endsize bytes of the archive data will  be
       written  out  (note,  however, that archive record boundaries will not be broken and so this limit may be
       slightly surpassed).  Other viable file size units include: K, Kb, KiB, Kbyte, Kilobyte for kilobytes and
       M, Mb, MiB, Mbyte, Megabyte for megabytes and G, Gb, GiB, Gbyte, Gigabyte for gigabytes.  These units may
       be optionally suffixed by an s and may be of mixed case.  Alternatively endsize may be an  integer  or  a
       floating  point  number  suffixed using a time unit as described in PCPIntro(1) for the interval argument
       (to the standard PCP -t command line option).
       Some examples of different formats:
          -s 100
          -s 100bytes
          -s 100K
          -s 100Mb
          -s 10Gbyte
          -s 10mins
          -s 1.5hours
       The default is for pmlogger to run forever.

       The -r option causes the size of the physical record(s) for  each  group  of  metrics  and  the  expected
       contribution of the group to the size of the PCP archive for one full day of collection to be reported in
       the log file.  This information is reported the first time each group  is  successfully  written  to  the
       archive.

       The  -U  option  specifies the user account under which to run pmlogger.  The default is the current user
       account for interactive use.  When run as a daemon, the unprivileged "pcp" account  is  used  in  current
       versions of PCP, but in older versions the superuser account ("root") was used by default.

       The  archive  is  potentially  a  multi-volume data set, and the -v option causes pmlogger to start a new
       volume after a certain size in records, bytes, or time units has been accumulated for the current volume.
       The  format of this size specification is identical to that of the -s option (see above).  The default is
       for pmlogger to create  a  single  volume  archive.   Additional  volume  switches  can  also  be  forced
       asynchronously  by  either  using  pmlc(1)  or  sending pmlogger a SIGHUP signal (see below).  Note, if a
       scheduled volume switch is in operation due to the -v option, then its counters will be  reset  after  an
       asynchronous switch.

       Independent  of  any  -v  option,  each  volume  of  an archive is limited to no more than 2^31 bytes, so
       pmlogger will automatically create a new volume for the archive before this limit is reached.

       Normally pmlogger operates on the distributed Performance Metrics Name Space (PMNS), however  if  the  -n
       option is specified an alternative local PMNS is loaded from the file pmnsfile.

       Under  normal  circumstances, pmlogger will run forever (except for a -s option or a termination signal).
       The -T option may be used to limit the  execution  time  using  the  format  of  time  as  prescribed  by
       PCPIntro(1).   The  time  is interpreted within the time zone of the PMCD server, unless the -y option is
       given, within which case the time zone at this logger host is used.
       Some examples of different formats:
          -T 10mins
          -T '@ 11:30'
       From this it can be seen that -T 10mins and -s 10mins perform identical actions.

       Alternatively, pmlogger runtime may be limited to the lifetime of another process  by  using  the  -p  or
       --PID  option  to  nominate the PID of the process of interest.  In this case the pmlogger will exit when
       the other process no longer exists.

       When pmlogger receives a SIGHUP signal, the current volume of the archive is closed, and a new volume  is
       opened.   This  mechanism  (or the alternative mechanism via pmlc(1)) may be used to manage the growth of
       the archive files - once a log volume is closed, that file may be  archived  without  ill-effect  on  the
       continued operation of pmlogger.  See also the -v option above.

       When pmlogger receives a SIGUSR2 signal, the current archive is closed, and a new archive is opened.  For
       this  to  succeed,  the  original  archive  argument  must  include  strftime(3)  meta  characters  (e.g.
       %Y%m%d.%H.%M),  otherwise  pmlogger  will  exit because the archive files will already exist and pmlogger
       will not over-write existing archive files.  Note that SIGUSR2 triggers pmlogger to  re-exec  itself  and
       re-parse  all  original  arguments.   This means that any relative time limits placed on it's termination
       time or sampling limit are reset and begin again.  This only  affects  relative  termination  times,  not
       absolute times e.g.  -T 5s is affected, but -T 5pm is not.

       Historically  the  buffers  for  the  current  archive  may be flushed to disk using the flush command of
       pmlc(1), or by using the -u option.  The current  version  of  pmlogger  and  the  libpcp  routines  that
       underpin  pmlogger  unconditionally  use unbuffered writes and a single fwrite(3) for each logical record
       written, and so ``flushing'' does not force any additional data to be written to the file system.  The -u
       option and the pmlc(1) flush command are retained for backwards compatibility.

       When  launched  with  the  -x  option,  pmlogger  will  accept  asynchronous control requests on the file
       descriptor fd.  This option is only expected to be used  internally  by  PCP  applications  that  support
       ``live record mode''.

       The  -m option allows the string note to be appended to the map file for this instance of pmlogger in the
       $PCP_TMP_DIR/pmlogger directory.  This is currently used internally to document the file descriptor  (fd)
       when  the  -x option is used, or to indicate that this pmlogger instance was started under the control of
       pmlogger_check(1), (-m pmlogger_check) or was re-exec'd (see execvp(3)) due to  a  SIGUSR2  signal  being
       received as described above (-m reexec).

       The  -H  option allows the hostname written into the archive label to be overridden.  This mirrors the -H
       option of pmcd(1) , but allows it to be specified on the pmlogger  process.   Without  this  option,  the
       value returned from the logged pmcd(1) is used.

       The -C option will cause the configuration file to be parsed and pmlogger will then exit without creating
       an output archive, so when -C is specified, the archive command  line  argument  is  not  required.   Any
       errors in the configuration file are reported.

       The  -d  or  --directory option may be used to specify the directory where the archive should be created.
       directory may include sh(1) metacharacters, like $(...)  or `...` or $var and pmlogger will expand  these
       to  produce a final directory path.  The resultant path must be absolute, not relative.  The -d option is
       intended primarily for use by pmlogger_check(1) and normal users would not  typically  need  to  use  the
       option,  as  the  directory  for archive is either implied by archive if it contains directory components
       else the current directory by default.

CONFIGURATION FILE SYNTAX

       The configuration file may be specified with the -c option.  If it is not,  configuration  specifications
       are read from standard input.

       If  conffile  does  not  exist, then a search is made in the directory $PCP_VAR_DIR/config/pmlogger for a
       file of the same name, and if found that file is used, e.g.  if  config.mumble  does  not  exist  in  the
       current   directory   and   the  file  $PCP_VAR_DIR/config/pmlogger/config.mumble  does  exist,  then  -c
       config.mumble and -c $PCP_VAR_DIR/config/pmlogger/config.mumble are equivalent.

       The syntax for the configuration file is as follows.

       1.   Words are separated by white space (space, tab or newline).

       2.   The symbol ``#'' (hash) introduces a comment, and all text up to the next newline is ignored.

       3.   Keywords (shown in bold below) must appear literally (i.e. in lower case).

       4.   Each specification begins with the optional keyword log, followed by one of the states mandatory on,
            mandatory off, mandatory maybe, advisory on or advisory off.

       5.   For  the  on  states,  a  logging interval must follow using the syntax ``once'', or ``default'', or
            ``every N timeunits'', or simply ``N timeunits'' - N is an unsigned integer, and timeunits is one of
            the  keywords  msec,  millisecond,  sec,  second, min, minute, hour or the plural form of one of the
            above.
            Internal limitations require the interval to be smaller than (approximately) 74 hours.  An  interval
            value  of  zero  is  a  synonym  for  once.  An interval of default means to use the default logging
            interval of 60 seconds; this default value may be changed to  interval  with  the  -t  command  line
            option.

            The  interval  argument follows the syntax described in PCPIntro(1), and in the simplest form may be
            an unsigned integer (the implied units in this case are seconds).

       6.   Following the state and possible interval specifications comes a ``{'', followed by a list of one or
            more  metric  specifications and a closing ``}''.  The list is white space (or comma) separated.  If
            there is only one metric specification in the list, the braces are optional.

       7.   A metric specification consists of a metric name optionally followed by a  set  of  instance  names.
            The  metric name follows the standard PCP naming conventions, see PMNS(5), and if the metric name is
            a non-leaf node in the PMNS (see PMNS(5)), then pmlogger will recursively descend the PMNS and apply
            the  logging  specification to all descendent metric names that are leaf nodes in the PMNS.  The set
            of instance names is a ``['', followed by a list of one or more space (or  comma)  separated  names,
            numbers  or  strings,  and a closing ``]''.  Elements in the list that are numbers are assumed to be
            internal instance identifiers, other elements are assumed to be external instance identifiers -  see
            pmGetInDom(3) for more information.

            If  no  instances  are  given,  then  the  logging  specification is applied to all instances of the
            associated metric.

       8.   There may be an arbitrary number of logging specifications.

       9.   As of PCP version 4.0 and later, any metric name specification that does not resolve to a leaf  node
            in  the  PMNS is added to an internal list of possible dynamic subtree roots.  PMDAs can dynamically
            create new metrics below a dynamic root node in their PMNS, and send a notification to clients  that
            the  PMNS  has  changed, see pmdaExtSetFlags(3) and in particular the METRIC CHANGES section for API
            details.  This mechanism is currently supported by pmdaopenmetrics(1) and pmdammv(1).  When a  fetch
            issued  by  pmlogger  returns  with  the  PMDA_EXT_NAMES_CHANGE flag set, pmlogger will traverse the
            internal list of possible dynamic subtree nodes  and  dynamically  discover  any  new  metrics.   In
            effect,  as  of PCP version 4.0 and later, pmlogger can be configured to dynamically log new metrics
            that appear in the future, after the configuration file is initially parsed.

       10.  Following all of the logging specifications, there  may  be  an  optional  access  control  section,
            introduced  by  the  literal  token  [access].   Thereafter  come access control rules that allow or
            disallow operations from particular hosts or groups of hosts.

            The operations may be used to interrogate or control a running pmlogger using pmlc(1) and fall  into
            the following classes:

            enquire        interrogate the status of pmlogger and the metrics it is logging
            advisory       Change advisory logging.
            mandatory      Change mandatory logging.
            all            All of the above.

            Access control rules are of the form ``allow hostlist : operationslist ;'' and ``disallow hostlist :
            operationslist ;''.

            The hostlist follows the syntax and semantics for the access control mechanisms used by PMCD and are
            fully  documented  in  pmcd(1).   An  operationslist  is  a  comma  separated list of the operations
            advisory, mandatory, enquire and all.

            A missing [access] section allows all access and is equivalent to allow * : all;.

       The configuration (either from standard input or conffile) is initially  scanned  by  pmcpp(1)  with  the
       options -rs and -I $PCP_VAR_DIR/config/pmlogger.  This extends the configuration file syntax with include
       file processing (%include), a common location to search for include files ($PCP_VAR_DIR/config/pmlogger),
       macro  definitions  (%define),  macro  expansion  (%name  and %{name}) and conditional inclusion of lines
       (%ifdef name ... %else ... %endif and %ifndef name ... %else ... %endif).

OPTIONS

       The available command line options are:

       -c conffile, --config=conffile
            Specify the conffile file to use.

       -C, --check
            Parse configuration and exit.

       -h host, --host=host
            Fetch performance metrics from pmcd(1) on host, rather than from the default localhost.

       -H hostname, --labelhost=hostname
            Specify the hostname to use instead of the one returned by pmcd(1).

       -I version, --pmlc-ipc-version=version
            Normally, pmlogger and pmlc(1) will autonegotiate a mutually acceptable version  for  their  private
            IPC  channel.   Use -I to force pmlogger to offer (at most) version as the version to be used.  This
            option may be required if pmlogger needs to be managed by an older version of pmlc(1) that fails  to
            autonegotiate correctly.

       -K spec, --spec-local=spec
            When  fetching  metrics  from a local context (see -o), the -K option may be used to control the DSO
            PMDAs that should be made accessible.  The  spec  argument  conforms  to  the  syntax  described  in
            pmSpecLocalPMDA(3).  More than one -K option may be used.

       -l logfile, --log=logfile
            Write all diagnostics to logfile instead of the default pmlogger.log.

       -L, --linger
            Run even if not the primary logger instance and nothing to log.

       -m note, --note=note
            Append note to the port map file for this instance.

       -n pmnsfile, --namespace=pmnsfile
            Load an alternative Performance Metrics Name Space (PMNS(5)) from the file pmnsfile.

       -N, --notify
            Notify service manager such as systemd(1) as needed.

       -o, --local-PMDA
            Use a local context to collect metrics from DSO PMDAs on the local host without PMCD.  See also -K.

       -p PID, --PID=PID
            Log specified metrics for the lifetime of the pid PID.

       -P, --primary
            Run as primary logger instance.  See above for more detailed description of this.

       -r, --report
            Report record sizes and archive growth rate.

       -s endsize, --size=endsize
            Terminate after archive size exceeds endsize.

       -t interval, --interval=interval
            Specify the logging interval.  The default value is 60 seconds.  Please refer to the ENVIRONMENT and
            FILES sections below regarding the PMLOGGER_INTERVAL environment variable  and  its  impact  on  the
            default logging interval.

       -T endtime, --finish=endtime
            Specify the endtime when to end logging.

       -u   Use unbuffered output.  This is the default (so this option does nothing).

       -U username, --username=username
            When in daemon mode, run as user username.

       -v volsize, --volsize=volsize
            Switch volumes after reaching archive volume size volsize.

       -V version, --version=version
            Specify archive version.  The default and the only accepted value is 2.

       -x fd
            Allow asynchronous control requests on the file descriptor fd.

       -y   Use local timezone instead of the timezone from the pmcd(1) host.

       -?, --help
            Display usage message and exit.

EXAMPLES

       For  each  PCP  utility,  there  is  a sample pmlogger configuration file that could be used to create an
       archive suitable for replaying with that tool (i.e. includes all of the performance metrics used  by  the
       tool).      For     a     tool     named     foo     this    configuration    file    is    located    in
       $PCP_VAR_DIR/config/pmlogger/config.foo.

       The following is a simple default configuration file for a primary pmlogger  instance,  and  demonstrates
       most of the capabilities of the configuration specification language.

            log mandatory on once { hinv.ncpu hinv.ndisk }
            log mandatory on every 10 minutes {
                disk.all.write
                disk.all.read
                network.interface.in.packets [ "et0" ]
                network.interface.out.packets [ "et0" ]
                nfs.server.reqs [ "lookup" "getattr" "read" "write" ]
            }

            log advisory on every 30 minutes {
                environ.temp
                pmcd.pdu_in.total
                pmcd.pdu_out.total
            }

            %include "macros.default"

            %ifdef %disk_detail
            log mandatory on %disk_detail_freq {
                disk.dev
            }
            %endif

            [access]
            disallow * : all except enquire;
            allow localhost : mandatory, advisory;

HOSTNAME CHANGES

       The hostname of the PMCD that is providing metrics to pmlogger is used in several ways.

       PMCD's  hostname (or the argument from the -H option) is included in the archive label and may be used to
       ensure that subsequent operations on  multiple  archives,  e.g.  pmlogextract(1),  are  only  applied  to
       archives from the same host.

       For  pmlogger  instances  using  a  local  PMCD  that  are  launched and managed by pmlogger_check(1) and
       pmlogger_daily(1), (or the systemd(1) or cron(8) services that use these scripts), the local hostname may
       also  be  used  to  construct the name of a directory where all the archives for the one host are stored,
       e.g. $PCP_ARCHIVE_DIR/<hostname>.

       And PMCD's hostname is also stored in the archive via the pmcd.pmlogger.hostname metric that is  used  as
       part  of  the  checks  to  ensure  that there is continuity of performance data after the nightly archive
       rotation by pmlogger_daily(1).

       The hostname of the PMCD host may change during boot time when the system transitions  from  a  temporary
       hostname to a persistent hostname, or by explicit administrative action anytime after the system has been
       booted.  When this happens, pmlogger may need to  take  special  action,  specifically  if  the  pmlogger
       instance was launched from pmlogger_check(1) or pmlogger_daily(1), then pmlogger must exit.  Under normal
       circumstances systemd(1) or cron(8) will launch a new pmlogger shortly thereafter, and this new  pmlogger
       instance will be operating in the context of the new hostname for the host where PMCD is running.

DERIVED METRICS

       As described in pmRegisterDerived(3), derived metrics provide a mechanism for extending the PMNS with new
       metrics defined at the PCP client-side using expressions over the existing performance metrics.   Derived
       metrics may be included in a pmlogger configuration file, but they come with some special handling rules.

       First,  the  values  of a derived metric, not the operand metrics in the derived metric's expression, are
       stored in the archive.  This is because the definition of a derived metric exists independent of pmlogger
       and archive and may be different, or not exist at all, when archive is replayed.

       To  avoid  ambiguity  during archive replay each derived metric's Performance Metric Identifier (PMID) is
       rewritten (or ``remapped'') to indicate that this was, but  now  is  not,  a  derived  metric;  refer  to
       pmRegisterDerived(3) for a detailed description of the PMID remapping.

DIAGNOSTICS

       The  archives  are  sufficiently  precious  that pmlogger will not truncate an existing physical file.  A
       message of the form
        ...: "foo.index" already exists, not over-written
        ...: File exists
       indicates this situation has arisen.  You must explicitly remove the files and launch pmlogger again.

       There may be at most one primary pmlogger instance per monitored  host;  attempting  to  bend  this  rule
       produces the error:
        pmlogger: there is already a primary pmlogger running

       Various other messages relating to the creation and/or deletion of files in $PCP_TMP_DIR/pmlogger suggest
       a permission problem on this directory, or some feral files have appeared therein.

FILES

       archive.meta
            metadata (metric descriptions, instance domains, etc.) for the archive

       archive.0
            initial volume of metrics values (subsequent volumes have suffixes 1, 2, ...)

       archive.index
            temporal index to support rapid random access to the other files in the archive

       $PCP_TMP_DIR/pmlogger
            pmlogger maintains the files in this directory as the map between the process  id  of  the  pmlogger
            instance and the IPC port that may be used to control each pmlogger instance (as used by pmlc(1))

       $PCP_VAR_DIR/config/pmlogger/config.default
            default configuration file for the primary logger instance launched from $PCP_RC_DIR/pmlogger

       $PCP_VAR_DIR/config/pmlogger/config.*
            assorted  configuration  files suitable for creating logs that may be subsequently replayed with the
            PCP visualization and monitoring tools

       $PCP_ARCHIVE_DIR/<hostname>
            Default directory for PCP archive files for  performance  metric  values  collected  from  the  host
            <hostname>.

       $PCP_SYSCONFIG_DIR/pmlogger
            additional environment variables that will be set when the primary pmlogger instance executes.  Only
            settings of the form "PMLOGGER_VARIABLE=value" will be honoured.

       ./pmlogger.log
            (or    $PCP_ARCHIVE_DIR/<hostname>/pmlogger.log    when    started    automatically    by     either
            $PCP_RC_DIR/pmlogger or one of the pmlogger(1) monitoring scripts such as pmlogger_check(1))
            all messages and diagnostics are directed here

ENVIRONMENT

       Normally pmlogger creates a socket to receive control messages from pmlc(1) on the first available TCP/IP
       port numbered 4330 or higher.   The  environment  variable  PMLOGGER_PORT  may  be  used  to  specify  an
       alternative starting port number.

       If set to the value 1, the PMLOGGER_LOCAL environment variable will cause pmlogger to run in a localhost-
       only mode of operation, where it binds only to the loopback interface.

       The PMLOGGER_REQUEST_TIMEOUT variable may be set by applications such as pmlc(1) to specify a timeout  in
       seconds  for  connection  requests  to  the  pmlogger  control  port.   If not set, connections may block
       indefinitely.  This variable would not normally be set by pmlogger itself.

       The PMLOGGER_MAXPENDING variable can be set to indicate the maximum length to which the queue of  pending
       pmlc connections may grow.

       The  default  sampling  interval used by pmlogger can be set using the PMLOGGER_INTERVAL variable (if not
       set, 60 seconds will be used).  Both the command line and  directives  in  the  configuration  file  will
       override this value.  It is an integer in units of seconds.

       On  platforms  using  systemd(1), and when the -N option is given, the NOTIFY_SOCKET environment variable
       would normally be set by the service manager prior to launching pmlogger.

       Two additional environment variables are used as part of the hand-off from one pmlogger instance  to  the
       next  during  a  re-exec operation, namely __PMLOGGER_REEXEC and __PMLOGGER_TZ.  The details of how these
       are used is an internal implementation detail, but end-users should avoid using variables of these  names
       in their shell's environment.

PCP ENVIRONMENT

       Environment  variables with the prefix PCP_ are used to parameterize the file and directory names used by
       PCP.  On each installation, the file /etc/pcp.conf contains the local values for  these  variables.   The
       $PCP_CONF variable may be used to specify an alternative configuration file, as described in pcp.conf(5).

SEE ALSO

       PCPIntro(1),   pmcd(1),   pmlc(1),   pmlogdump(1),  pmlogger_check(1),  pmlogger_daily(1),  systemctl(1),
       systemd(1),   PMAPI(3),    __pmServerNotifyServiceManagerReady(3),    execvp(3),    pmRegisterDerived(3),
       pmSpecLocalPMDA(3), strftime(3), PMNS(5), pcp.conf(5), pcp.env(5), pmlogger(5), chkconfig(8) and cron(8).