oracular (1) webpingvis.1.gz

Provided by: pcp_6.3.0-1_amd64 bug

NAME

       webpingvis - visualize Web server response time

SYNOPSIS

       webpingvis [-CiVz] [-A align] [-a archive] [-h host] [-m max] [-n pmnsfile] [-O time] [-p port] [-S time]
       [-T time] [-t interval] [-x version] [-Z timezone]

DESCRIPTION

       webpingvis displays a summary of Web server response-time statistics collected from the  Performance  Co-
       Pilot (PCP) infrastructure.  The display is modulated by the values of performance metrics retrieved from
       the target host (which is running pmcd(1) and the pmdawebping(1) Performance  Metrics  Domain  Agent)  or
       from the PCP archive log identified by archive.  The display is updated every interval seconds (default 2
       seconds).

       As in all pmview(1) scenes, when the mouse is moved over one of the bars, the current  value  and  metric
       information  for  that  bar will be shown in the text box near the top of the display.  The height of the
       bars is proportional to the performance metric values relative to the maximum, as controlled by  size  of
       the URLs being fetched by pmdawebping(1), and the -m option (see below).

       The bars in the webpingvis scene represent the following information:

       Size
           The  green  bars  indicate the relative sizes of the results returned for each URL in the pmdawebping
           workload.

       Response
           For each URL in the pmdawebping workload, the components of the Web  server  response-time  (connect,
           head and body) and the total response-time is displayed.

           To the right, the component and total times are summed over all URLs in the pmdawebping workload.

       Errors
           The  four  red  error bars indicate the number of socket, HTTP, HTML or other errors that occurred in
           the last iteration of the pmdawebping workload.  Any of these errors will terminate the request for a
           URL.

       webpingvis  uses pmview(1), and so the user interface follows that described for pmview(1), which in turn
       displays the scene within an Inventor examiner viewer.  For generic control of the viewer, see ivview(1).

       webpingvis passes most command line options to pmview(1).  Therefore, the command line  options  -A,  -a,
       -C,  -h, -n, -O, -p, -S, -t, -T, -x, -Z and -z, and the user interface are described in the pmview(1) man
       page.

       Options specific to webpingvis are:

       -i     The URL names are not included as labels in the scene by default.  The -i option forces them to be
              included.

       -m max Change  the  normalization  factor  for  the response-time bars.  The value for max is in units of
              milliseconds, and should be the expected maximum value for the total response-time aggregated over
              all URLs in the pmdawebping workload.  The default value is 1000 milliseconds.

       -V     The derived configuration file for pmview(1) is written on standard output.  This may be saved and
              used directly with pmview(1) if the user wishes to customize the display, or modify  some  of  the
              normalization parameters.

CAVEATS

       As webpingvis sorts the configured URLs by size, running webpingvis shortly after starting pmdawebping(1)
       may result in the URLs being sorted incorrectly as they may not have been fetched.

       The ~ character may not be parsed correctly by pmview(1).  Therefore, if pmdawebping(1) is  fetching  any
       URLs containing ~ then webpingvis will not launch.

FILES

       $PCP_VAR_DIR/pmns/*
                 default PMNS specification files
       $PCP_VAR_DIR/config/pmlogger/config.webpingvis
                 pmlogger(1)  configuration  file  that can be used to create a PCP archive suitable for display
                 with webpingvis
       $PCP_VAR_DIR/config/pmchart/Web.Response
                 A pmchart(1) configuration file for monitoring Web server response time

PCP ENVIRONMENT

       Environment variables with the prefix PCP_ are used to parameterize the file and directory names used  by
       PCP.   On  each  installation, the file /etc/pcp.conf contains the local values for these variables.  The
       $PCP_CONF variable may be used to specify an alternative configuration file, as described in pcp.conf(4).

SEE ALSO

       pmcd(1),  pmchart(1),  pmdawebping(1),  pmdumplog(1),  pminfo(1),   pmlogger(1),   pmval(1),   pmview(1),
       weblogvis(1) and webvis(1).